  • Posted a comment on discussion Engineering on CODESYS Forge

    SOLVED We had an EtherCAT master in our project, when we started our runtime RTE he uses that port for his communication. When we deleted the EtherCAT master it all works fine. This means that we need an extra ethernet port to program the device so the other one can be used for EtherCAT communication.

  • Posted a comment on discussion Engineering on CODESYS Forge

    Hello, Thanks for this info, we can now load the program but when we start the runtime PLC, the connection is gone. We also can't ping the PC where the PLC is running on anymore. We installed Codesys Development program on that PC and so we can load the program, and get online. Unfortunately this is not what we want to do. Our softPLC (PC where the PLC is running on) should be programmed from the programmers laptop. Is it possible that we should change some settings in the "Remote PLC" from the RTE...

  • Posted a comment on discussion Engineering on CODESYS Forge

    Hello, i'm a coworker of Gerwinvdw, We tried some things but at the moment we can't access the PLC, we updated our program device to SP16 to match the runtime version. Also we checked the BIOS settings etc etc. We can ping the other SoftPLC but when we scan network we can't find the runtime control RTE running on that PC. We installed the Codesys EtherExpress driver (CmpEt1000MPD). We also selected this in the component manager of the runtime control see attachments. Still we can't scan the device,...

  • Modified a comment on discussion Runtime on CODESYS Forge
  • Modified a comment on discussion Runtime on CODESYS Forge
  • Posted a comment on discussion Runtime on CODESYS Forge

    UPDATE We found the problem and we can now load the program to the SoftPLC. We needed to install the right driver and select that one in the PLC configuration under the tab component manager. The next problem occurs when we try to start the PLC. When we start the connections falls down. We also can't ping the softPC anymore. We installed the Codesys EthernetExpress driver that's needed for RTE. When we look into the PLC from our softPLC we see our problem loaded.

  • Posted a comment on discussion Runtime on CODESYS Forge

    UPDATE We found the problem and we can now load the program to the SoftPLC. We needed to install the right driver and select that one in the PLC configuration under the tab component manager. The next problem occurs when we try to start the PLC. When we start the connections falls down. We also can't ping the softPC anymore. We installed the Codesys EthernetExpress driver that's needed for RTE. When we look into the PLC from our softPLC we see our problem loaded.

  • Posted a comment on discussion Runtime on CODESYS Forge

    Hello, We are trying to run a PLC program on a RTE controller in Windows 10 as SoftPLC. In Windows Control SL this works perfectly but for out project we needed the faster RTE. When we try to download we get this error. We have a Intel I218-LM Gigabit Ethernet Adapter, this should we fine right? Can someone help us with this problem? Regards, Stan