User Activity

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    I got a the answer from Balluff support team. Basically the ports are not active to communicate. Now all good. Anyone have the same issue, feel free to reach out I will help you guys. sudhakarp@peerlesse.com.

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    I got a the answer from Balluff support team. Basically the ports are not active to communicate. Now all good. Anyone have the same issue, feel free to reach out I will help you guys. sudhakarp@peerlesse.com.

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    Hi, I'm trying to make a connection via ethernet/ip, but there is something wrong. Ethernet/IP scanner is running in demo mode (yellow icon and status about running in demo mode), but adapter is not working at all (red triangle). In I/O mapping of the adapter I have a warning "The bus is not running. The shown values might not be up-to-date). Does anybody know how to fix it?

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    Hi again, I'm trying to make a connection via ethernet/ip, but there is something wrong. Ethernet/IP scanner is running in demo mode (yellow icon and status about running in demo mode), but adapter is not working at all (red triangle). In I/O mapping of the adapter I have a warning "The bus is not running. The shown values might not be up-to-date). Does anybody know how to fix it?

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    HI There, I'm looking your help to configure my device. I dont where is issue from? I have balluff IO-Link master, when I run the program still showing error. Ethernet IP address as 192.168.1.100 (this looks good) The device IP address as 192.168.1.103 (this showing error)

  • Posted a comment on discussion Runtime πŸ‡¬πŸ‡§ on CODESYS Forge

    I have wago controller (750-8102) with IO-Link Master (750-657). I configured as 24 byte data in the IO-Link Master. However, when I scan the device in codesys it has 10 byte only. I have attached screen shot for reference! What I'm doing wrong here? is there any limitation with wago-codesys? or if I use old data module how to update the latest one? I appreciate your time to help me on this!

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    I have wago plc 750-8102, with IO-Link 750-657. In addition I have few IO-Link devices from Balluff (Stack light, DI-Hub, AI-Hub). After configured the Balluff device parameter data using wago IO-Check in to IO-Link master(750-657, In-1 byte, Out-8byte for port1, Data frame 24byte). When I try to use in Codesys, unfortunately, the IO mapping variable showing 10 byte only? Its not showing 24byte? Any idea, what I'm missing here or doing wrong?

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    I got the answer. Thank you!