  • Posted a comment on discussion Runtime πŸ‡¬πŸ‡§ on CODESYS Forge

    I have wago controller (750-8102) with IO-Link Master (750-657). I configured as 24 byte data in the IO-Link Master. However, when I scan the device in codesys it has 10 byte only. I have attached screen shot for reference! What I'm doing wrong here? is there any limitation with wago-codesys? or if I use old data module how to update the latest one? I appreciate your time to help me on this!

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    I have wago plc 750-8102, with IO-Link 750-657. In addition I have few IO-Link devices from Balluff (Stack light, DI-Hub, AI-Hub). After configured the Balluff device parameter data using wago IO-Check in to IO-Link master(750-657, In-1 byte, Out-8byte for port1, Data frame 24byte). When I try to use in Codesys, unfortunately, the IO mapping variable showing 10 byte only? Its not showing 24byte? Any idea, what I'm missing here or doing wrong?

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    I got the answer. Thank you!

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    Hi here is the update, do you have any idea how to get this root password?

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    Hi Timvh, you are amazing. Thank you for the clarification. I could be able to download the PFC100 SL and installed in Codesys V3. Unfortunately, I can't read the wago device (PFC100-750-8102) in Codesys. I have attached the screenshot for reference. Do you have any suggestions to discover the device? Please correct me here if I did anything wrong here? I appreciate your time and clarifications!!!

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    Hi All, I am trying to use WAGO PLC using IO link with Balluff IO devices, since there is user fee for !eCockpit. How to add WAGO PLC(750-8102) into Codesys V3 and link devices. I am not sure, it could be done through? I am working in distributor company, so trying to setup Balluff demo devices(Stack Light, Diffuse sensor, Condition monitoring and more). Any suggestions highly appreciate?

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    Hi There, yes, that is correct. Now everything working fine. I really appreciate your input!

  • Posted a comment on discussion Engineering πŸ‡¬πŸ‡§ on CODESYS Forge

    Hi All, I am trying to use PWM signal to control valve driver. Using analog input as a Pot 10kohms and analog output to driver input as command signal. This project using uControl MC4 (Enovation) through Codesys software. However, this simple program looks good in simulation and in hardware its not any progress. I don't know what I'm doing wrong. Any suggestions highly appreciate? Here is my sample program?