Post by imdatatas on TO_STRING operator not working for IMPLICIT ENUM
CODESYS Forge
talk
(Post)
Hi Everyone, It is a very useful feature to be able to obtain the enum value as a string with the TO_STRING operator by defining {attribute 'to_string'}. However, unfortunately the same function does not work for IMPLICIT ENUMs. I hope that {attribute 'to_string'} behavior can also work for Implicit Enumeration data types in one of the upcoming Codesys versions. https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_pragma_attribute_to_string.html https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_datatype_implicit_enumeration.html Best regards, Imdat
Last updated: 2025-03-27
Post by alez on CANOpen SDO to write VISIBLE STRING
CODESYS Forge
talk
(Post)
Hello, I am experiencing difficulties in configuring a CANopen device by sending SDOs. In particular I am attempting to write an Object Dictionary that has VISIBLE STRING as the Data Type. When I try to configure the sending of an SDO from Codesys to configure this parameter I am not allowed to enter a string value. In my particular case I am trying to change the Manufacturer Device Name ( Index 0x1008 ). Could it be that Codesys doesn't manage these types of variables?
Last updated: 2024-04-29
Post by otbeka on CAA File Handling: "Read only" error
CODESYS Forge
talk
(Post)
Hi, On CODESYS V3.5.19.50 I am using the latest 3S File Access library (CAA File & CAA Types) to save and retrieve configuration data from the User Data section of an SD card, via file called config.txt. The application reads the file to memory once upon initialisation, and then the only other operation is overwriting the file with the updated configuration whenever the user changes the settings. An issue is ocurring, seemingly randomly, where the config.txt file, and all surrounding directories, cannot be written to by the unit, returning a READ_ONLY_CAA error upon file open. This sometimes does not clear even after power-cycling the PLC several times, yet checking the file permissions with ls -l shows normal read, write, and execute access. I am wondering if this is caused by the PLC itself or by an issue in my application. I have included my CAA File handler function block (SD_Card_Bin(FB).txt) and any associated types/calls below: TYPE ConfigData : STRUCT Config : ARRAY[0..256] OF STRING(64); NumberOfStrings : UDINT; END_STRUCT END_TYPE TYPE Buffer : STRUCT Data : ARRAY[0..SIZEOF(ConfigData)] OF BYTE; DataLength : UDINT; END_STRUCT END_TYPE A case within my MAIN PRG: mode.WriteConfigDataToFile: VisuElems.CURRENTVISU := 'Screen_Write'; IF xModeHasChanged THEN iErrorCount := 0; iRoute := 0; END_IF CASE iRoute OF 0: inBuffer := ConfigData_To_Buffer(GVL.UnitData); xConfigError := FALSE; xDataConfigured := FALSE; iRoute := 1; 1 : //Read Data from Card SD_Card_Bin.strFileName :=FileName; SD_Card_Bin.iFileOperation := 2; SD_Card_Bin(xExecute :=TRUE, WriteBuffer := inBuffer, xDone =>xDataConfigured, xError=>xConfigError, strErrorCodes=>strError); IF xDataConfigured THEN SD_Card_Bin(xExecute :=FALSE); IF xConfigError THEN iRoute := 32767; ELSE iRoute :=100; END_IF END_IF 100: // The end bCurMode := mode.DisplayProcessVariables; 32767: // Config error iErrorCount := iErrorCount + 1; IF iErrorCount > 2 THEN // Repeats 3 times, if no progress abandons and returns error bCurMode := mode.WriteError; ELSE iRoute := 0; // Try again END_IF END_CASE I'd like to rule out my application as the cause of this bug - help via comments or criticism would be greatly appreciated.
Last updated: 2025-03-19
Post by sumit on Not able to see input data coming from eip adapter on codesys
CODESYS Forge
talk
(Post)
Hello there, I have an eip adapter running (remotely) that is sending data back to eip scanner (running on codesys). I can send data from scanner (codesys) to the adapter but not getting the data back from the adapter. I have verified the incoming data on wireshark but I don't see this data in the codesys. I have tried local variable mapping and global variable mapping not variable values just stays at 0. Please guide.
Last updated: 2024-02-29
Hi, I try to send and receive data using a UDP connection via SysSocket 3.5.17.0. While sending data works fine, I have problems with the receiving part. I am able to capture the received data of client side in wireshark But unable to capture it on the codesys
CODESYS Forge
talk
(Thread)
Hi, I try to send and receive data using a UDP connection via SysSocket 3.5.17.0. While sending data works fine, I have problems with the receiving part. I am able to capture the received data of client side in wireshark But unable to capture it on the codesys
Last updated: 2024-06-03
Post by k4zz on Continuous Build Server
CODESYS Forge
talk
(Post)
Hallo Martin, Thank you so much for the Code example. It works really fine for .porject Types. However, I encountered a challenge when attempting to apply it to .library Types. I also tried the option to "Perform static analysis automatically after compilation" # get Project values myProject = projects.primary # Creates an active application app = myProject.active_application # build Application and run static code analysis app.generate_code() Could you please offer any insights into why this might be occurring?
Last updated: 2024-03-15
Post by k4zz on Scripting static code analysis
CODESYS Forge
talk
(Post)
Currently, I am working on integrating static code analysis into our CI/CD pipeline. Specifically, I have successfully performed static code analysis for .project types, and it works flawlessly. However, I have encountered difficulties in executing the same for .library types. In this regard, I have tried two methods: system.commands["staticanalysis", "run"].execute() # get Project values myProject = projects.primary # Creates an active application app = myProject.active_application # build Application and run static code analysis app.generate_code() your help is greatly appreciated.
Last updated: 2024-03-18
CODESYS V35SP12 does not save data setting with rapsberry after reboot
CODESYS Forge
talk
(Thread)
CODESYS V35SP12 does not save data setting with rapsberry after reboot
Last updated: 2018-04-17
2D array , data move from a column to another column
CODESYS Forge
talk
(Thread)
2D array , data move from a column to another column
Last updated: 2011-03-23
Which kinds of data is transferred with 'Scan for devices' command?
CODESYS Forge
talk
(Thread)
Which kinds of data is transferred with 'Scan for devices' command?
Last updated: 2020-12-14
Data Sources Manager causing exception due to float or double type in OPC server
CODESYS Forge
talk
(Thread)
Data Sources Manager causing exception due to float or double type in OPC server
Last updated: 2024-07-01
Content update through Data URI on Web Brower on Visualization Toolbox
CODESYS Forge
talk
(Thread)
Content update through Data URI on Web Brower on Visualization Toolbox
Last updated: 2024-07-30
Check Connection Status of the OPC-UA Server for Data Source Manager with OPC-UA Client
CODESYS Forge
talk
(Thread)
Check Connection Status of the OPC-UA Server for Data Source Manager with OPC-UA Client
Last updated: 2024-09-07
RPI Serial port connects with no errors but not data being transmitted or received
CODESYS Forge
talk
(Thread)
RPI Serial port connects with no errors but not data being transmitted or received
Last updated: 2024-09-30
FbHTTPs_Get how to get data from a website and use it in codesys
CODESYS Forge
talk
(Thread)
FbHTTPs_Get how to get data from a website and use it in codesys
Last updated: 2025-06-16
Eine Nummer (Data Type=Double) Schicken mit TCP Client Server Codesys
CODESYS Forge
talk
(Thread)
Eine Nummer (Data Type=Double) Schicken mit TCP Client Server Codesys
Last updated: 2021-09-08
"Out of global data memory". Is there a way to increase the memory?
CODESYS Forge
talk
(Thread)
"Out of global data memory". Is there a way to increase the memory?
Last updated: 2022-03-28
store trend data in the PLC - How to use it (Codeys 2.3.9.7)
CODESYS Forge
talk
(Thread)
store trend data in the PLC - How to use it (Codeys 2.3.9.7)
Last updated: 2022-04-07
[SOLVED][ModBus TCP/IP] How to read data from thermostat.
CODESYS Forge
talk
(Thread)
[SOLVED][ModBus TCP/IP] How to read data from thermostat.
Last updated: 2017-06-08
How do I configure a visualisation text object to enter data?
CODESYS Forge
talk
(Thread)
How do I configure a visualisation text object to enter data?
Last updated: 2016-05-20
3.5.17: Setting up OPCUA Client data source to another PLC OPCUA server
CODESYS Forge
talk
(Thread)
3.5.17: Setting up OPCUA Client data source to another PLC OPCUA server
Last updated: 2021-11-02
i need to do a data logging with 750-842
CODESYS Forge
talk
(Thread)
i need to do a data logging with 750-842
Last updated: 2013-08-26
How to read SD card data and store in array
CODESYS Forge
talk
(Thread)
How to read SD card data and store in array
Last updated: 2012-11-26
exporting or copying the COE online data from an ethercat slave device
CODESYS Forge
talk
(Thread)
exporting or copying the COE online data from an ethercat slave device
Last updated: 2019-10-30
PM564 ETH for reading data from modbus serial slave using COM1 port
CODESYS Forge
talk
(Thread)
PM564 ETH for reading data from modbus serial slave using COM1 port
Last updated: 2017-11-28
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.