Redundancy Codesys Runtime, Synchronization
CODESYS Forge
talk
(Thread)
Redundancy Codesys Runtime, Synchronization
Last updated: 2026-01-30
CODESYS and Github Copilot
CODESYS Forge
talk
(Thread)
CODESYS and Github Copilot
Last updated: 2026-02-13
Codesys KNX implementation
CODESYS Forge
talk
(Thread)
Codesys KNX implementation
Last updated: 2026-03-04
Codesys V2.3 🇬🇧
CODESYS Forge
talk
(Discussion)
Forum about V2.3
Last updated: 2026-03-19
Post by rossanoparis on Upgrading CODESYS runtime from v4.7 to v4.9 using a bash script leads to lose the licences stored in the soft container
CODESYS Forge
talk
(Post)
System information - Controller: KUNBUS RevPi CONNECT-S - OS: Linux buster 32bit 5.10.103-rt62-v7l #1 SMP PREEMPT_RT armv7l GNU/Linux - CODESYS v3.5 SP19 Patch 2 I'm facing a problem related to codesys licences using a procedure based on a bash script. Such bash script detect the presence of new .deb files and install them on system. My automation solution don't allow to be maintained by dedicated personal, thus even the CODESYS runtime SW must be installed using an "automatic" procedure instead of using the CODESYS tool. remark I've been using the following procedure since the runtime v4.5 without any issue. Before installing the new runtime packages, I need to copy the file CODESYSControl_User.cfg (here attached) because of new section which is necessary to add in order to allow some folders to be written by CODESYS runtime v4.9 Up to now, this has been unnecessary, this is the main difference between my previos bash file and the new one. remark If I skip this action, everythings goes fine, but my CODESYS application can't work as it needs to access some folders on controller's file system. Process - Before the procedure: the licenses are OK (see attached file lic-01.png) - After the procedure: the new CODESYS runtime version is correctly installed, but the software container with v1.19 and all licences disappear (see attached file lic-02.png) This is the synthetic content of bash script I'm using. # Stop runtime sudo service codesyscontrol stop sudo service codesysedge stop # Move the new CODESYSControl_User.cfg file # New configuraton with folders declared sudo mv -f CODESYSControl_User.cfg /etc # Install runtime package echo N | sudo apt-get install -y --allow-downgrades codesyscontrol_raspberry_4.9.0.0_armhf.deb # Install edge gateway package echo N | sudo apt-get install -y --allow-downgrades codesysedge_edgearmhf_4.9.0.0_armhf.deb # Reboot controller sudo reboot Thanks in advance
Last updated: 2023-09-19
Post by alex00 on DCS / Central Engineering for Codesys
CODESYS Forge
talk
(Post)
Hello together I'm currently investing in possibilities to have a central engineering software / system for Codesys based controllers. Something like a DCS / SCADA depending on where you see the functionality. We plan to use more or less vanilla codesys. The tool should support the following: - Connect to multiple PLC's in a project to see its variables and debug it. - Central Engineering capabilities (for example shared libraries in a project). - Download the new code / binaries to the plc. - Maybe have functionality to combine visualization elements and logic together. - See the live status variables on all the systems (crosscommunication). I see that codesys theoretically supports engineering of multiple PLC's, but I couldnt find to much functionality for a DCS type of operation, but that could be lack of knowledge. Any tips from you? Is Codesys good enough for this and maybe there are some manufacturers which build around it? Or are there good tools on the market with Codesys support (and the engineering is separate, but download to codesys possible). The use case is distributed energy installations like Heating pumps, Photovoltaics, etc. All these installations should have a PLC with codesys installed and run in one larger network, the PLC's are connected via VPN. Thanks for your inputs Greetings
Last updated: 2024-02-19
Post by timvh on Problem Reading Registers via Modbus from non Codesys device
CODESYS Forge
talk
(Post)
According to the documentation: https://wiki.teltonika-networks.com/view/RUT956_Modbus You need to create a Channel to read 2 registers from address 143 to get the lattitude. It doesn't specify if you need to read it as a Holding Register or as an Input Register. You could try both. So in the Teltonika router, you need to enable it as being a Modbus Server. Then in CODESYS add an Ethernet Adapter, then a Modbus Client (Master) and to the Client (Master) add the Modbus Server (Slave). Set the IP address and add the Channel. The please consider that CODESYS doesn't update any variables when they are not used in the application. In the I/O mapping tab of your I/O configuration, you can set the "Always update" to enabled.
Last updated: 2025-03-08
Post by mbmik on IoDrvModbusTCP_Diag not defined when using MODBUS
CODESYS Forge
talk
(Post)
Hi Im trying to setup a Weidmüller WL2000 to run with MODBUS, to get some data from a server. Codesys V3.5 SP20. The issue is, that whenever i attach an ethernet port and add MODBUS Master und also a Slave, codesys will compile the project, but there always seem to be some remaining errors, which or only visible, when setting the messages window to "Pre-Compiled". I tried a lot of stuff to get rid of these errors, but cant find to seem the reason. New installation of codesys, cleaned project, setup completely empty new project, manually adding libs. Nothing helps. Any help is apreciated. Maybe we are doing something wrong.. Example Project is available, if somebodey wants to take a look. Greetings and thanks alot
Last updated: 2024-04-15
Post by pernockham on Is there a pragma for init/instantiation of local variables in FB (like in Methods)
CODESYS Forge
talk
(Post)
Im using a pointer as input for a FB and for convenience I like to use 'referenced' variable internally. I use this setup in methods which works because internal variables are instantiated for each call. In a FB these variables are instantiated and initiated for the first call only. Is there a pragma/attribute available that changes this behaviour to mirror a 'method'-call?
Last updated: 2024-10-31
Post by bjarne-pagaard on WebVisu with Runtime Based User Management, Default user (no login) - is it possible?
CODESYS Forge
talk
(Post)
Hi, With the new Runtime Based User Management, is there any way for WebVisu clients to be logged in to a default user automatically - no login prompt? I would like for the default user to be able to perform normal operation of the machine, without logging in to the WebVisu. This is possible with the Legacy User Management. For the Runtime based user management, there seems to be a default user for the TargetVisu - but not for the WebVisu. -Bjarne
Last updated: 2024-03-14
Post by programmierer on UDB Block in Codesys V2.3 implementieren um Werte an bestimmte IP-Adresse zu senden
CODESYS Forge
talk
(Post)
Hallo zusammen, ich möchte mich hiermit an euch wenden, in der Hoffnung, dass ihr mir bei meinem Problem behilflich sein könnt. Ich bin neu in der Programmierung und arbeite aktuell mit einem Wago Controller in unserem Labor, der eine Wärmepumpe steuert. Mein Ziel ist es, vier spezifische Werte an eine bestimmte IP-Adresse zu senden. Dazu habe ich versucht, in das vorhandene CODESYS-Programm der Wärmepumpe zusätzliche UDP-Blöcke einzufügen, um die Datenübertragung zu ermöglichen. Leider hat das Senden der Daten bis jetzt nicht funktioniert. Ich habe auch Bilder der Blockkonfiguration beigefügt, um einen besseren Einblick in den Aufbau zu geben. Über jegliche Hilfestellung würde ich mich sehr freuen. Vielen Dank im Voraus!
Last updated: 2024-07-19
Post by tama00 on GPIOs not running with Raspberry Pi 4 (and SPI connection)
CODESYS Forge
talk
(Post)
Hello everyone, I have a working SPI connection (with transferExt) between a Raspberry master with Codesys and an ESP32 slave. I would also like to use a few GPIO pins. Is there a problem with using SPI AND GPIOs? Environment: Raspberry Pi 4+ with Raspian from Oct 23 Codesys V3.4 SP19 Patch 5 with Runtime Version 4.10.0.0 Device: GPIOs B+/Pi2 My problem: The status is displayed as “GPIOs : not running”. And also during mapping the message “The bus is not running. The values shown are perhaps not actual”. However, the variable changes that I make in my program are displayed under “Current Value”. In the Logic Analyzer, the pin toggles during transmission with small intervals of +-4us (seems to be a cyclical disorder, but I don't know where exactly it could be coming from). This applies to pins that I actually use (output) but also to the other GPIOs (not used). With GPIO 4, the line remains permanently high. Attached is a screenshot from the Logic Analyzer. Channel 1,3,5 were GPIO pin 26, 22, 17 Would be very grateful for help. Best regards
Last updated: 2024-05-06
Post by jinlee on Reading Camera Feed in Codesys v3.5 webvisu web element browser
CODESYS Forge
talk
(Post)
Hi guys, I have been trying to use web browser element in the visualisation to connect with my IP camera. From the past few weeks, I have not been successful of doing it. I thought it would be very easy to just connect to the ip address, but apparantly it is not. I am using WAGO PLC PFC200 and my PC as a webvisu. or else can you guys please advice me on which kind of camera should I use as a CCTV system in my project instead of IP Camera. Ideally, I want multiple web browser elements to browse my IP Cameras in one frame. Kind regards, Jin.
Last updated: 2024-09-16
Post by jinlee on Reading Camera Feed in Codesys v3.5 webvisu web element browser
CODESYS Forge
talk
(Post)
Hi guys, I have been trying to use web browser element in the visualisation to connect with my IP camera. From the past few weeks, I have not been successful of doing it. I thought it would be very easy to just connect to the ip address, but apparantly it is not. I am using WAGO PLC PFC200 and my PC as a webvisu. or else can you guys please advice me on which kind of camera should I use as a CCTV system in my project instead of IP Camera. Ideally, I want multiple web browser elements to browse my IP Cameras in one frame. Kind regards, Jin.
Last updated: 2024-09-16
Post by jinlee on Reading Camera Feed in Codesys v3.5 webvisu web element browser
CODESYS Forge
talk
(Post)
Hi guys, I have been trying to use web browser element in the visualisation to connect with my IP camera. From the past few weeks, I have not been successful of doing it. I thought it would be very easy to just connect to the ip address, but apparantly it is not. I am using WAGO PLC PFC200 and my PC as a webvisu. or else can you guys please advice me on which kind of camera should I use as a CCTV system in my project instead of IP Camera. Ideally, I want multiple web browser elements to browse my IP Cameras in one frame. Kind regards, Jin.
Last updated: 2024-09-16
Post by reinier-geers on License problem gateway
CODESYS Forge
talk
(Post)
The hole setup is made by 3s. So its a comination of one not two. If Epis decide not to support extra licence whats then the funtion of providing an option with a single license ?? So the idee by 3s has a flod. Epis change the system to add the Stick. I send controller inc stick to Epis. On my software i can see the stick. An then you tel me i need a other license to use an license ?? Makes completly no sense. Codesys should be flexible but is not. I tried Delta. But has no HMI and has its own Codesys ?? Why ?? Then i tried Crist. The block there own system by a password. But dont know the password and cant switch it off. At the end the want me to pay for support to solve ther own made problem. So i send it al back. The extra license is adviced by 3s . Now a few month later still no working solution.
Last updated: 2024-05-01
Post by arjunk on How to correctly create a device descriptor (.devdesc.xml) for a custom Linux ARM64 PLC in CODESYS 3.5.21.20?
CODESYS Forge
talk
(Post)
I’m trying to integrate a custom PLC into CODESYS so that it appears under the Device section. From what I understand, this requires a .devdesc.xml device descriptor file. I attempted to create the XML manually, but whenever I try to install it in order to generate a .package file, CODESYS crashes. CODESYS version: 3.5.21.20 Target PLC: Linux ARM64–based My questions are: Is there an official or easier way to generate a valid .devdesc.xml file for a custom PLC? Are there tools, templates, or examples that can help ensure the XML is structured correctly and won’t cause crashes? For Linux ARM64 targets specifically, is there a recommended starting point (e.g., modifying an existing device descriptor)? Any guidance or best practices for creating and packaging custom device descriptors would be greatly appreciated.
Last updated: 2025-10-06
Post by antonz on CoDeSys v3.5: creating libraries for both 32-bit and 64-bit controllers
CODESYS Forge
talk
(Post)
Looking for thoughts on creating libraries that can be used on both 32-bit and 64-bit controllers. We are currently writing software in CoDeSys for both target types and will continu to do so for the near future. Projects are always unique, no straight forward copy/paste, yet there is enough similarity between them to use libraries for recurring logic. I do not want to create and maintain twice for both platforms if this is not absolutely necessary. I am aware of useful datatypes like __XWORD, __XINT, __UXINT. Still looking for more information and/or sample code for portable pointer arithmetic. In addition to that: how should one go about when creating and working with compiled libraries? Would I need to compile the same lib twice, once for 32-bit targets once for 64-bit targets? I would end up with two different libs with the same namespace, which does not sound elegant to me. Note: I did not intentionally make the previous paragraph bold. The forge forum software seems to do this automatically upon insertion of a word which starts with two underscores, e.g. __XWORD (yeah, here we go again :) )
Last updated: 2025-08-25
Post by duvanmoreno24 on Modbus writing on value change
CODESYS Forge
talk
(Post)
Yes, I tried to do what you put in the first code. However, I have a problem with that and that is that the inputs must be declared with the type. I have many data types running in my code (real, int, uint, bool) and I can't put them in the same function, another thing is that I need to instantiate that function for everything I want to write to the slave. You put a for to 200 but it means that it has to be the same data type and inside the array, but I want to get them individually. I'm struggling to do it in a good and efficient way like wago's E-cockpit does. in the first screenshot you can see, you simply type in value, change the package of things you want to write in value change and it does everything by itself automatically, without comparing any old and new values and even less having the need to activate a bool. , it is perfect.
Last updated: 2024-04-03
Post by bruno-roth on Read "Homed" status from EtherCAT drive
CODESYS Forge
talk
(Post)
Hello, the information if your axis is already homed you could only find out direct from your Slave. In DS402 status there is no Bit defined. But some manufacturer of Drives use some optional bits or status. E.g. if you have Schneider Electric LXM32 Servo you will find this information in Bit 15. You have to check the manual of your used Servo-Drive f this information is provided in any object and then read it out with SDO.
Last updated: 2025-01-08
Post by atone on Change IO-Link Device Interface connected to a Profinet-Slave at Runtime
CODESYS Forge
talk
(Post)
I need to be able to update (change) the interface of an IO-Link device at runtime. The reason is the connected sensor can be selected at runtime, and some sensors we use have a 2 byte IN interface, others have a 4 byte IN interface, others 16 byte IN, others 16 byte IN/OUT (see attached screenshot). Is it possible at all? When yes, which function should I use? Thank you!
Last updated: 2025-03-18
Post by yannickasselin on Dynamically enabling/disabling Modbus slave devices in runtime (performance issue with timeouts)
CODESYS Forge
talk
(Post)
I would definitely try using the "Reconfigure" function block from "CAA Device Diagnosis@ library. https://content.helpme-codesys.com/en/libs/CAA%20Device%20Diagnosis/3.5.17.0/CAA-Device-Diagnosis/Function-Blocks/Reconfigure/Reconfigure.html#:~:text=This%20function%20block%20reads%20and,take%20effect. Although I have not tried it with Modbus, I had great success with EtherNet/IP, Profinet and EtherCAT. You can also have a look at the other functions in this library. There are useful functions to help iterate through all the nodes under a master node.
Last updated: 2025-08-12
Post by vformanek on No source code available for profinet library
CODESYS Forge
talk
(Post)
Hello, I have been using CODESYS for a while and after updating to version 3.5.18.50 the code randomly stops with this fault. Why is that ? I have tried to locate the fault in the Call Stack but I dont know what to do now... I have updated the projects properly for the version I am using. This fault started happening after like 14 days of using the new version of CODESYS.
Last updated: 2023-08-23
Post by hermsen on Control Runtime Toolkit
CODESYS Forge
talk
(Post)
Hi, there is a plethora of hardware available for it to be succesful on. In theory every ARM32/64 or x86/64 device is a potential target. Next to this there are embedded device platforms for which specific toolchains are available. A good starting for manufactureres of CODESYS capable devices is available here: https://www.codesys.com/the-system/codesys-inside.html. That should give you a good reference point.
Last updated: 2023-12-31
Post by smartcoco on Request a dark mode for CODESYS
CODESYS Forge
talk
(Post)
CODESYS IDE is not a modern IDE. Its interface is ugly, its operation is not user-friendly, its functions are lacking, its feedback is slow, and its development is not good enough. In fact, CODESYS is a helpless choice under the current situation. But this situation will not last long. For example, SIMATIC AX is a strong competitor of CODESYS, which is more open and inclusive.
Last updated: 2024-12-03
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.