Post by jasperclauwaert on Persistent Retain Variables Not Visible in Online View (WAGO PFC100 + CODESYS) CODESYS Forge talk (Post)
Hi everyone, I’m working on a WAGO PFC100 with CODESYS. During development everything worked fine, but in the final stage I set several variables to PERSISTENT RETAIN. When I go online, most of these persistent variables cannot be monitored. Instead, I see: <Value of the expression cannot be retrieved> Interestingly, a few variables do show their values correctly, but the majority do not. The variables are not used as pointers or in any unusual way. The application compiles and runs without errors. Has anyone experienced this before? Is this a known issue with PFC100 or CODESYS? Any ideas on what could cause this behavior? Thanks in advance! Jasper
Last updated: 2025-10-23

Post by jasperclauwaert on Persistent Retain Variables Not Visible in Online View (WAGO PFC100 + CODESYS) CODESYS Forge talk (Post)
Hi everyone, I’m working on a WAGO PFC100 with CODESYS. During development everything worked fine, but in the final stage I set several variables to PERSISTENT RETAIN. When I go online, most of these persistent variables cannot be monitored. Instead, I see: <Value of the expression cannot be retrieved> Interestingly, a few variables do show their values correctly, but the majority do not. The variables are not used as pointers or in any unusual way. The application compiles and runs without errors. Has anyone experienced this before? Is this a known issue with PFC100 or CODESYS? Any ideas on what could cause this behavior? Thanks in advance! Jasper
Last updated: 2025-10-23

Post by damian177 on Codesys V3.5 + Pixtend v1.3 + RaspberryPi CODESYS Forge talk (Post)
Hi, I use Pixtend v1.3 with my RaspberryPi with Codesys V3.5 SP15 Patch1. Actually in my project I used two packages: - CODESYS Contro for Raspberry PI 3.5.15.10 - PiXtend for CODESYS 1.3.8.0 Now I would like to extend my project about the IIot Libraries SL package, I installed them. Next I added SMS_Service_SL 1.0.0.8 version library and I have problem with compile my project because I get error: [ERROR] PiXtend_DemoProject_q: Library Manager [Device: PLC Logic: Application]: Could not open library '#CAADTUtil'. (Reason: The placeholder library 'CAADTUtil' could not be resolved.) Any have idea what can I do to properly add SMS library to my project?
Last updated: 2023-09-26

Post by ricola on Change default node Id name on Raspberry Pi CODESYS Forge talk (Post)
EDIT : https://forge.codesys.com/forge/talk/Engineering/thread/cb5a492aa0/ hyplcmotion - 2022-12-16 Found out how! Needed to connect to PFC200 via Putty, and open CodesysControl.cfg with “sudo nano /etc/CODESYSControl.cfg”. Then adding following command to the end of file, and use the name you want, save/close CODESYSControl.cfg, and reboot your PLC. [CmpOPCUAProviderIecVarAccess] CustomNodeName= PFC200 Hi! , I'm digging up this issue cause we have still this long name within current versions on CodesysControl. Is it a lock for "demo" licences or can it be changed in some way ? This DeviceSet name is too way long with spaces inside, not easy to handle with string parsing... Cheers !
Last updated: 2024-10-10

Transparency of element rectangle works only in simulation not in WebVisu CODESYS Forge talk (Thread)
Transparency of element rectangle works only in simulation not in WebVisu
Last updated: 2023-05-25

Can "Best Fit in Online Mode" be used in Visualization CE CODESYS Forge talk (Thread)
Can "Best Fit in Online Mode" be used in Visualization CE
Last updated: 2012-05-31

Is there a pragma for init/instantiation of local variables in FB (like in Methods) CODESYS Forge talk (Thread)
Is there a pragma for init/instantiation of local variables in FB (like in Methods)
Last updated: 2024-11-05

Connecting Parameter 'A' in G-Code to Physical Axis in CNC Project CODESYS Forge talk (Thread)
Connecting Parameter 'A' in G-Code to Physical Axis in CNC Project
Last updated: 2025-05-07

Zugriff auf BYTE in einem WORD / INT in einem DINT etc... CODESYS Forge talk (Thread)
Zugriff auf BYTE in einem WORD / INT in einem DINT etc...
Last updated: 2023-01-19

Transparenz Element Rechteck funktioniert nur in der Simulation nicht in der WebVisu CODESYS Forge talk (Thread)
Transparenz Element Rechteck funktioniert nur in der Simulation nicht in der WebVisu
Last updated: 2023-07-15

Issue with Forward Open Connections in Ethernet/IP Protocol Stack in Codesys CODESYS Forge talk (Thread)
Issue with Forward Open Connections in Ethernet/IP Protocol Stack in Codesys
Last updated: 2024-06-25

Issue with Forward Open Connections in Ethernet/IP Protocol Stack in Codesys CODESYS Forge talk (Thread)
Issue with Forward Open Connections in Ethernet/IP Protocol Stack in Codesys
Last updated: 2024-06-25

OSCAT Scale_r function not working in LD 4.60 works in LAD2 on 3.5.21sp3 CODESYS Forge talk (Thread)
OSCAT Scale_r function not working in LD 4.60 works in LAD2 on 3.5.21sp3
Last updated: 2025-10-23

OSCAT Scale_r function not working in LD 4.60 works in LAD2 on 3.5.21sp3 CODESYS Forge talk (Thread)
OSCAT Scale_r function not working in LD 4.60 works in LAD2 on 3.5.21sp3
Last updated: 2025-11-21

Post by pernockham on Pointer/reference to Codesys trend recording object? CODESYS Forge talk (Post)
I have a Hmi that acts as an interface for many (mostly identical) units. This is managed by a sort of "mux" where you select which unit that should be presented on the HMI. Backbone is solved by a HMI-gvl defined as reference/pointer to "unit-data", which then can be set to the individual units. While this works for most data I still have not sorted how to solve this for the trend recordings. One solution would be to have already "mux:ed" data values as source for the/one trend. However then the trend would contain data from different units/sources which could/will cause confusion. If its possible to "clear" this can be mitigated. Possibly let the trend have its own "mux-selector" (ie, the hmi are focusing on unit#3 however trend data is locked on unit#5), that could also work.. Or, let each unit have its own trend recording, which is focused if the unit is "selected". Can I reach the trend recording objects programmatically (those defined in the device tree)? Ie, can I use a "reference/pointer to these trend recording objects"? There is a field "data source" in the trend properties dialog which seems to resemble what Im looking for? But Im not sure if I can use it in some way, I cannot change anything in this field it only says <local application="">. </local>
Last updated: 2025-09-16

Post by jeroenaero on CodeSys Raspberry pi I2C driver not found CODESYS Forge talk (Post)
Hello, We have a problem with CodeSys on a raspbery pi with an ADS1015 analog to I2C module. It can't find the I2C device on the i2c bus, it says No I2C Driver Found. When we use the RPI terminal we can find the I2C device and read it out. The i2c-1 bus is also accessible from codesys. The device address of the Analog to I2C module is 0x48. Can someone have a look what the problem is? i submitted the screenshots in the attachments. i also include the device description and library.
Last updated: 2024-11-07

Post by alexgooi on Codesys virtual control redundancy CODESYS Forge talk (Post)
Dear Forum, I’m currently investigating the possibilities of Codesys virtual control (Linux). The research rig consists of a PC (Debian with real time kernel) with a docker server installed on it. The PC is communicating with a Remote I/O and I have to say the performance is great. The process in the container is running (soft) real time. Currently I’m checking if it is possible to replace physical controllers by remote I/O’s and run the Codesys applications on a docker server. If I’m going into this route the reliability of the server is very important (server down, complete installation down), is it possible to make the server redundant without needing 2 separate containers (including licenses), and maintaining the real time behavior? I’m not only expecting direct answers, if you have any idea or thought they are very welcome. Kind regards Alex
Last updated: 2025-09-03

Post by installwhat on C0077 on one machine but not another CODESYS Forge talk (Post)
I have a version of codesys 3.5.16 on my local machine and a vm. The local machine has loads of codesys versions and libraries installed etc. I can open the FPosCR_Example_Project_SP16_patch1 project on my vm without any errors. On the local machine I get the error C0077: unknown type IoDrvEthercatLib.ETC_CO_SdoWrite. I can, on the local machine, declare a var of type IoDrvEthercatLib.ETC_CO_SdoWrite and include it in the code without adding an extra error. The problem only seems to affect the library. This is seems more an issue with my codesys set up rather than something with festo. I would like to know the possible causes. I understand most of the library manager features but it's not clear how to find the cause. Thanks
Last updated: 2024-06-11

Post by gseidel on CAM Motion Recover after STO CODESYS Forge talk (Post)
Dear Mr. Kolev, I'm not sure I understood correctly. But this is my take on your question: When the STO of the slave is triggered, store the current master position (e.g. 225 units) After the reset of the slave error, call MC_SetPosition on the virtual master and reset it to the stored position (225 units) Optionally, before MC_CamIn is restartet, move the slave back to the slave position corresponding to the stored master position. (If you do this, no ramping in will be necessary) Restart MC_CamIn, with absolute master position and absolute slave position. Choose the StartMode that is appropriate for your machine. Best regards, Georg Seidel
Last updated: 2026-02-16

Post by rringo on Function block not autofilling CODESYS Forge talk (Post)
I am attempting to place a block and make it an Analog sensor. When I go to change the name like in the instructional video on youtube it does not give me an option to autofill the block with a known configuration. This is a problem I have in Codesys 2.5 and 3.5. Did I mess up the install of the program or need to install a library? Any help would be appreciated. https://www.youtube.com/watch?v=PkJYQeIUmIM&t=136s at time mark 2:15ish The first image is what I can do and the second is what the videos function autofills to.
Last updated: 2023-08-24

Post by matthew on Persistence Manager Backup CODESYS Forge talk (Post)
Hi, Is there a process to restore Persistence Manager files? I have backups of persistence variables used in a machine that is currently operating and tuned and all set points adjusted. There are about 500 persistence variables, they are building another identical machine. I would like to use Persistence Manager files from the first machine in the second also. I have tried copying the files and replacing them on the new RPI but then the Persistence Manager gets errors and then they are all reset to 0 etc I have tried adjusting the times to match. Instead of replacing whole file, I tried just changing the contents inside the file, but still does not work. I may be missing something here, but surely there must be a way to load a backup. Thanks!
Last updated: 2023-10-18

Post by nico-hefr on Python script command for "Access Control" CODESYS Forge talk (Post)
Hi everyone, I use Python Script to generate some POU in Codesys V3.5 SP19 and I would like to limit the "Access Control" to them thanks to the Python command. Is there any commands that allow to edit the "Properties... >> Access Control" of the POU? The other possibility is to set the permissions with "Project >> User Management >> Permissions... >> Project objects >> Modify >> ... >> myPOU", but I did not find the related Python commands. Otherwise, is there a global setting that allows to set the permissions by default? For example, Modify = Denied for everyone user by default. Thank you in advance for your help, Nico
Last updated: 2024-07-18

Post by pistola on Error during Updating the Visualisation CODESYS Forge talk (Post)
I've got a visualization I'm working on with some rectangles and lines. When I simulate the program I get an Error and Message in my message box, "Error during Updating the Visualisation:" and "Overflow error." Any ideas on how to fix this? I only have 70 elements total for this visualization. I am using absolute movement for a few of the elements, would this cause the issue? The visualization seemed fine before I added these movement elements, but there is only 7 that move, that doesn't seem like it should over load the system. I am currently testing using simulation so I'm not sure if that has an effect either. I tried looking in the codesys help manual and couldn't find anything referencing this.
Last updated: 2024-11-19

Post by rossanoparis on Internal Error (ARM): Unsupported conversion! With new version v3.5 SP21 CODESYS Forge talk (Post)
I have updated CODESYS development tool to the version v3.5 SP21 (64bit) The previous version was v3.5.20.40 Compiling an existing application with the new evelopment tool I get the following error. kunbusiodrvrevpibridge, 1.4.1.0 (kunbus gmbh): IoDrvScanModules [IoDrvRevPiBridge](Line 51, Column 1 (Impl)): Internal Error (ARM): Unsupported conversion! This error was not reported in the previous compiler version and is now highlighted in a third-party library, which I cannot change or modify. The error is due to the following conversion: m_udiError := TO_UDINT(excCode); . The excCode variable is a system type, declared as shown below, and should be converted to a UDINT excCode : __SYSTEM.ExceptionCode; m_udiError: UDINT; . I would appreciate it if someone could provide feedback on this issue.
Last updated: 2025-04-15

Post by durallymax on Dynamical scaling of bar graph without the bar itself CODESYS Forge talk (Post)
I'm a fan of the analog indicators from ISA101. To recreate these, I use a number of rectangles that are dynamically sized and colored based on the input configuration. To keep it standard and easy, everything is built around 100px height. Then when instantiated in a frame, it can be resized as needed with the math remaining the same. The math logic is in a METHOD called by the rear most rectangle. These indicators do not use a "filling" bar graph, rather a fixed bar graph with a carrot to track the current value.
Last updated: 2025-06-06