Post by tk096 on Some 'pathetic' errors in SoftMotion program CODESYS Forge talk (Post)
Hi, I suppose that you are referring to the error code "SMC_FB_WASNT_CALLED_DURING_MOTION"? Starting of Softmotion version 4.15.0.0 the instance path of the function block that has not been called is logged into the device log. This might help you to identify why it has not been called.
Last updated: 2024-07-18

Post by pietrobalint on Persistent variables are not read after initialization CODESYS Forge talk (Post)
Hi, I realized that if I replug the power supply the persistent variables lost their value with the new software too. Cold reset do not affect the variables value but hardware reboot still reset the values. Application Composer can't be activated. What is the solution?
Last updated: 2024-10-11

Post by hyys12 on Energie price CODESYS Forge talk (Post)
I am definetly not an expert in this field, but it does seem like you need a propper API key in the URL. Right now you are using the token 'ANWB' in your URL, which the website returns an error, since this is not valid. Somehow you first need a propper API key. I hope that makes sense.
Last updated: 2024-12-06

Post by s1ack on Wago PFC200 Ethernet / IoDrvEthernet Issue? CODESYS Forge talk (Post)
I changed the interfaces to br0 & br1 as they are designated on the Wago PFC200. That issue is resoved. However, on site I have very high system cpu usage, system as in Linux. Presently it is not known why - my bench system does not exhibit such high system usage. In the past this was due to IGMP network traffic every 250uSec from synchronized inverters.
Last updated: 2025-01-22

Post by manuknecht on FileDialog - OnDialogClosed not called anymore CODESYS Forge talk (Post)
I had similar issues with the OnDialogClosed not being called. I realized that this behaviour is resolved, when the according visualization object on which the input configuration is set is moved to the foreground. Somehow, the object has to be one of the lowest elements in the Element List (i.e. in the foreground) for it to work.
Last updated: 2025-04-25

Post by atone on Change IO-Link Device Interface connected to a Profinet-Slave at Runtime CODESYS Forge talk (Post)
OK, I figured out that I can simply define all the sensors as 16 bytes IN/OUT, even if they are not all used. EDIT: The negative effect is that each bit is taken into account as an I/O for the license, even if not used.
Last updated: 2025-04-28

Post by andrej on Creating, using an external Function. CODESYS Forge talk (Post)
One step closer Hello finally the SoftPlc starts to load the dll on start up, however it is not successfull. I create a new minimal example Lib_XMATH.dll. Could please give me a hint, why the dll is not succesully loaded yet. Inputs would be highly appreciated. Many thanks.
Last updated: 2025-04-30

Post by eschwellinger on Codesys Virtual control SL CODESYS Forge talk (Post)
Hi, which CODESYS Version are you using exactly? Either update to 3.5.21.x if you are on 3.5.20.x if not - add a more secure pw. Seems that on adding the login credentials it is mandatory in 4.16.0.0 -to have complianct to password policy seems a bug that the message not occure.
Last updated: 2025-08-06

Post by eschwellinger on TargetVisu option missing in IDE CODESYS Forge talk (Post)
It is not needed to add Targetvisu connector - for using the TargetVisu for Linux. The reason is - TargetVisu for Linux is basically a remote TargetVisu which could connect to any CODESYS plc not only the loacal one - therefore only a Webvisu connector is needed to have it work. & it seems a bug with this anoying update proposal.
Last updated: 2025-08-23

Post by alexgooi on How to protect library project? CODESYS Forge talk (Post)
Hi aniket-b, If you save the library as a compiled library you are not able to see the source code. When the end user tries to view inside the object, CODESYS will give a notification that the source code is missing, see attachment. In short if you don't send the source code, it will not show.
Last updated: 2024-01-25

Post by namwind on Wago 8210 CODESYS Forge talk (Post)
Hi guys, I ran into problem with the controller is not saving the project into the internal memory. I was able to download the project to the controller, but as soon as I try to recycle the power it power back up with no project. I have not ran into this problem before. Please help me out thank you.
Last updated: 2024-03-02

Post by vincentd on Datasource OPC UA Client error ID:7012 CODESYS Forge talk (Post)
I have not used this client / server OPC UA combination since. We were only making some kind of proof of concept. I did understand that there could be some kind of bug. I do not know if the supposed bug has been resoved since. Perhaps you could try what piautomation is suggesting
Last updated: 2024-04-05

Post by koehler on Codesys 3.5.12 Module not Found CODESYS Forge talk (Post)
Hi there, I am getting troubles with a project. In the Hardware configuration I got some Lenze drives 9400. One of them got as status " Module not Found". Connection are good. ID Node of the Canopen network is also good. I don't find any reason for this status, nor any options to check.
Last updated: 2024-04-17

Post by davecfc on Codesys installation package fails because not signed CODESYS Forge talk (Post)
Also had this problem when working on legacy project. My packege was CODESYS Code Generator ARM 4.0.3.0.package. To manage this I used PackageManagerCLI.exe. This tool does not validate certificates appearently. My command: "C:\Program Files\CODESYS 3.5.17.30\CODESYS\Common\PackageManagerCLI.exe" --profile="CODESYS V3.5 SP17 Patch 3" --install=""C:\Users\sample_user\AppData\Local\Temp\APInstaller\5wx1k02a.r2t\CODESYS Code Generator ARM 4.0.3.0.package""
Last updated: 2024-04-18

Post by mgengler on Recipe Manager - Not Creating Recipe Files CODESYS Forge talk (Post)
Thanks for info... However, I changed the directory to: C:\ProgramData\CODESYS\CODESYSControlWinV3x64\58719825\PlcLogic\Recipes It still displays the content of this folder OK, however still will not write or read files. Is this the PLCLogic area you speak of? I also tried adding this path the the CodesysControl.cfg file. But still can't get it to work. Any additional direction would be appreciated!
Last updated: 2024-05-20

Post by mg0815 on ERROR: Calling the program "AlarmStorage_Prg" is not allowed from multiple tasks CODESYS Forge talk (Post)
I use Codesys 3.5.21.1 too I have absolutelly the same fault. Do you know the solution? I get the same massages accept the last one (up to your's from 2025-08-03 04:38) The last messages do not appear. (your's later than 2025-08-03 04:40) Reagards Mg
Last updated: 2025-11-04

Post by willebro on "Distributed clocks are not synchronized, Rea time problem on hardware" ? CODESYS Forge talk (Post)
https://forge.codesys.com/forge/talk/Engineering/thread/632c29cb93/#8d94 The above comment is the best, but if you just want to see it work you can try disabling the distributed clock. It's not the right thing to do but it should resolve that error.
Last updated: 2 days ago

Post by yr00 on OPC UA datasource low read frequency CODESYS Forge talk (Post)
Hello everyone, I am trying to test the OPC UA client feature in Codesys. My setup is the following; I have a Codesys simulation/ visualization running on Control Win V3. My OPC UA server is hosted on a Siemens 1518 PLC using PLCSim Advanced. The setup is completely virtual so there are no really PLCs. Everything is on my laptop. Writing data from the Codesys simualtion to the server is very quick. I have a PLC program running on another 1500 PLC which reads data from simulation via the server, and changes in the simulation (e.g. button pressed) appear within hundreds of miliseconds if not tens of miliseconds in my PLC program. However, when it comes to reading data from the OPC UA Server by Codesys, it taks around 1-2s. I connected a UAExpert client and it gets update very quickly so I am fairly sure the problem is with Codesys. I have tried changing the update rate in datasource -> General and Diagnosis, but it doesn't seem to have an effect. Do you guys have any suggestion on what I can do?
Last updated: 2023-08-29

Post by toby on Ethercat Servo Setup CODESYS Forge talk (Post)
Hi Everyone, I have a simple project with a single servo, but its my first time using Codesys and motion, so I'm a little confused and lost, I've tried to read the tutorial online, but I'm not having much luck sorry. Can I please ask for some pointers. I have a ComfilePi HMI (Raspberry Pi) communicating to a Omron R88D-1SN08H-ECT amplifier. Please see the attached project file (which is better for sharing, the project file, or a archive?). This file was simply for testing the motion of the servo before anything else is tested with it. The project simply rotates the servo 1 rotation when called for, but the speed can vary based on user input. Nothing much fancy. As yet, I haven't had any servo movement, no errors on the amplifier display. How do I link the motion FBs to the physical drive? Thank you very much for any help you can offer. I'm sorry if I'm doing something very stupid or basic and getting it wrong. Have a good day. Toby
Last updated: 2023-09-20

Post by oi18ct on ARM SL Development Board Recommendation CODESYS Forge talk (Post)
Hello codesys forum, My company is looking at developing a solution with Codesys ARM SL. The requirements will not tax the capabilities of Codesys. I would like to buy an AMR 7 or 8 Dev Board for experimenting. I am looking for a recommendation as I have minimal experience with Linux. Any input from the forum would be most appreciated as the hardware requirements as provided by Codesys for ARM SL seem pretty minimal (basically a arm7 or 8 with Debian is all). Our needs are small in scale- something like 8 digital inputs, 6 digital outputs, 2 analog inputs and 1 analog output. A small gui will be published via web visualization for external display (no local display). Communications with ModbusTCP and uart/RS485. It may be necessary to access i2c and make c or python calls to some existing code that is pretty small. Something like the EMCraft STM32MP1 SOM Starter Kit or Octavo Systems OSD32MP1-RED development board? Ideally something that has a path to a SoM for production. Kontron appears to have some interesting options too. Just having a hard time deciding where to start. Thanks in advance... LC
Last updated: 2023-11-11

Post by nizrahel on OpC UA server on Raspberry Pi 64 SL runtime CODESYS Forge talk (Post)
Hi all! I'm working on an home project using a Raspberry Pi 3 device with Codesys for Raspberry Pi 64 SL runtime. I would like to create the HMI interface with Siemens WinCC Unified (or Advanced) configuring the Raspberry as OPC UA server. I tryed everything, but I didn't find the way to let the OPC UA connection works using UaExpert. I tryed to use anonymous connection, authenticated connection and the ip address instead of the server name in the path connection. There is no way to connect to the OPC UA server and I was asking myself if this feature is really supported for the runtime version used. Another strange thing I noted, is that is not possible to quickly create an OPC UA certificate in the Security Screen, as show in any tutorials. I have correctly created the Symbol Configuration enabling the OPC UA feature. I attach to this topic some printscreen of the actual configuration (sorry for the italian language interface, but I didn't find the way to switch to english). Thank you very much in advance for your support and advices!
Last updated: 2023-12-03

Post by faceplant on CmpDynamicText unresolved references CODESYS Forge talk (Post)
Hello! I am new to codesys so I am sorry if this is not the right place to ask this question. I am using codesys V3.5 SP20 Patch 1 + (64-bit) and a Groov EPIC PLC (GRV-EPIC-PR2). I am trying to build and deploy my application to the PLC, but when I log in I get 6 errors (codesys_error.png). It seems that the errors have to do with the CmpDynamicText system library which I have as version 3.5.20.0. I have tried to add CmpDynamicText to the ComponentManager section in the PLC's CODESYSControl.cfg file as described in this forum post and still hit the same error. I noticed that the library is grayed out in the library manager, which I think might be the issue. However I don't remember if it was grayed out before I encountered this issue. Please let me know if I can provide anymore info. Thank you!!!
Last updated: 2024-07-19

Post by karel-bas on Loosing connection to emulation running on Linux CODESYS Forge talk (Post)
Hello, I am trying to emulate my code but for some reason my Codesys IDE keeps loosing connection to the emulator. I am constantly pinging virtual machine on which its running and its running fine, but codesys refuses to reconect to it, and is not able to rediscover it. Codesys 3.5 SP20 Patch 1 I have linux installed like image in attachment.(using version 4.12) Linux VM is set up to use up to 4 cores and 8gb of ram, with nothing else runing on it. I dont have a license so I am aware that the emulation shouldnt run for more then 120 minutes I am able to, login, get sysinfo, reboot etc from codesys IDE for certain period of time (5minutes) then my connection gets lost, sometimes I can login again, but sometimes i have to reboot the VM. Any suggestions what might be the issue ?
Last updated: 2024-09-19

Post by hyys12 on Help understanding analog in-/outputs CODESYS Forge talk (Post)
Hello. I am currently working on a WAGO PLC, where I am trying to wrap my head around how the analog inputs and outputs work in codesys. I have looked far and wide on the internet, for a general introduction to the whole concept, but I have not had any luck with finding anything that helped me understand it better. The whole goal is for me to be able to read an analog input from a temperature sensor, as well as using an analog output, to control a frequency inverter. I know these have nothing to do with each other, but that is all I have on hand right now. I am trying to program this using Ladder Diagram. The only thing is, that every video/guide I have seen/read using LD, just adds a whole lot of function blocks, to do all kinds of stuff they don't explain. My general question is, how would one go ahead and read the analog input, as well as transmit an analog output? Is there some kind of specific function block I would have to use for this, or some great video I can watch, to understand the inner workings. Is it somehow possible to see the values the PLC recieved/sends? Regards.
Last updated: 2024-12-11

Post by mubeta on Strange problem with the ‘MC_SetPosition’ function CODESYS Forge talk (Post)
CoDeSys 3.5.19.7 Target Berghof MX6 In a simple SoftMotion programme with two stepperless modular axes from CMZ, one is simply controlled in speed, but a spot must perform a positioning. I use the function MC_SetPosition() both to reference the axis at power-up and also to correct the actual position to a fixed machine reference detected with proximity. The function has only one instance and I actually use a booelan variable to control the ‘Execute’ input. Well, I cannot correctly change the axis position on the fly if it is running at high speed. The servomotor works in a speed range between 0°/s and 720°/s, (gearbox output with a 1:6 ratio). As long as the servomotor is operating at speeds below about 400 °/s, the function is able to correct the position correctly even when forcing values far apart, but at high speeds, from 400 °/s upwards, the correction no longer takes place. For example, trying to correct the position of 280° into 300° with absolute mode, the axis that is moving at speed actually shifts the position by a few degrees, not the expected 20. I don't understand why with the servo drive running slowly the position shift occurs correctly, while increasing in speed it no longer works.
Last updated: 2025-01-09