Post by kuegerls on SysProcessExecuteCommand2 and CANopen Device
CODESYS Forge
talk
(Post)
Hello, CODESYS Control is running on my RevPi, and my system communicates over a CANbus with a master using the ConnectCan module (Slave - CANopen Device). The communication works perfectly fine so far. However, as soon as I call a Python script with "SysProcessExecuteCommand2" that creates a CSV file and executes without errors, the master does not adopt any changes to the Transmission Process Data Objects (TPDOs). I don't quite understand what one has to do with the other, and perhaps someone can help me with this. Here is my script call: SysProcess.SysProcessExecuteCommand2(pszCommand:='python /home/pi/test.py', pszStdOut:=sCMDOutput, udiStdOutLen:= SIZEOF(sCMDOutput), pResult := ADR(eResult)); Thank you in advance! Best regards, Stefan
Last updated: 2024-06-20
Post by ppix on Establishing TLS Connection with MQTT Broker using MQTT Client SL Package
CODESYS Forge
talk
(Post)
For anyone confused with the process visit this link (the bottom section about creating a .pfx file) https://content.helpme-codesys.com/en/LibDevSummary/certificate.html#import-of-client-certificates-with-private-key. I solved this problem by creating a .pfx file and importing it into the security store under 'Own Certificates'(must have SP18 or newer to import .pfx). I used a gitbash shell to enter the openssl command that created the .pfx file. Once you import the file, in your TLS context, set your 'sUseCaseName' to be the same as the name listed in the 'Information' column of your imported certificate. This did it for me
Last updated: 2024-06-20
Post by daanyouknow on Using a raspberry pi and NVLs to log variables outside of Codesys
CODESYS Forge
talk
(Post)
Hi, My PLC/controller doesn't support OPC UA, so my current plan to create a ringbuffer/circular logger is to connect a raspberry pi to it, use the Network Variable List receiver and sender and raspberry pi codesys runtime to get the variables to the raspberry pi, after which I will use the pi which DOES support OPC UA to get the variables to a python program which logs the desired variables for a certain amount of time for me, would this work? I don't want to spend 50+ euros + licencing fees for a solution that might not work.
Last updated: 2025-11-14
Post by jbcregen on Accessing parameters from a structure or function block with the web interface
CODESYS Forge
talk
(Post)
I have a project with hundreds of OPC-UA variables available on the network. A lot of these variables are used actively in various scripts that run in background in the OS (Linux). I'm experimenting with Automation Server and I have a hard time understanding how the web interface populates its parameters list for a given PLC (<plc details="" parameters="" for="" plc="" 'xyz'="">).</plc> In this page, it looks like the only variables available are the ones that are of a "base" type : bool, TIME, String, INT, etc. All the variables that are nested into function blocks or structures are not available in the web interface, even if they are available to any OPC-UA client. Is this a limitation of the Automation Server or is there something that can be done in Codesys?
Last updated: 2025-12-01
Post by tali on Configuration of disabled/deactivated visu elements
CODESYS Forge
talk
(Post)
would be great to have such fucntionality. Sometimes it is not clear for user which elemetns are blocked and which are not - the greyed out eleemtns are not so different for low resolution / low quality screeens. What I have in my mind as well is to have a possibility to detect the visu Element clicked on and get its Access Rights. If it is blocked/deactivated, the dialog can be rised with INFO 'please login first with proper rights'. It is possible now to have a Mose event Handler ( Examples -> EventHandler) and rise the dialog out of ST (Exapmpals -> ST Dialogs). I am struggling still with getting the separate Visu Element under the mouse and its structure info
Last updated: 2025-12-05
Post by gseidel on Can't get SMC_SmoothPath to work
CODESYS Forge
talk
(Post)
Hi bertus, I cannot see any problem in the code you posted. Just some ideas: What is the value of D_ANGLE_TOL? - Do you need the assignment bAbort := NOT bDecoder? Does it help to leave it out? Any errors (e.g. SMC_SmoothPath.Error/ErrorID) or PLC log messages? What if you comment out SMC_SmoothMerge and SMC_LimtiDynamics, is corner smoothing still not working? Is bDecode written from a different task (e.g. visu)? Then I would recommend to assign to a local variable (bDecodeLocal := bDecode) and use that for all FBs. Otherwise, FBs might see different values of bDecode in a single cycle, which will cause problems. Regards, Georg
Last updated: 2025-12-17
Post by ranadheer on Assistance for MQTT configure with external broker (Mosquitto)
CODESYS Forge
talk
(Post)
Hi everyone Am trying to make establish MQTT connection , where am using IIOT example for this as a demo mode. where i had given IP-address of of local Linux application as a 172.31.239.67 and port number as 1883 in the PLC_PRG itself, and preparing the publish message by manually as " this is from published message", and this should receive at the subscriber side. Aim: To make communicate external publisher to the CODESYS by using MQTT protocol. By any chance having reference documents about this implementation please share here. and suggest the process to make it possible. I had uploaded reference project file after updating address in th PLG_PRG, kindly assist to configure with the broker
Last updated: 2025-12-03
Post by mascara on JOG continues in WCS ( SMC_GroupJog2 )
CODESYS Forge
talk
(Post)
I'm using the SMC_GroupJog2 block from the SM3_Robotics library for manual movement of an AxisGroup in WCS coordinates. The observed behavior is: When pressing X+, the X-axis starts moving correctly. If I press Y+ during the movement, the block interrupts the current movement and starts a new movement in X and Y. If I release any button, all axes stop, even if another button is still pressed. Example: Pressing X+ → X moves Pressing X+ and Y+ → X stops momentarily and starts XY movement Releasing X+ while holding Y+ → all axes stop The expected behavior would be: to allow simultaneous continuous movement on multiple axes to not interrupt movement when another axis is added or removed. Is there a correct configuration of SMC_GroupJog2 to achieve this behavior, or is there another block more suitable for continuous manual jog in AxisGroup (WCS)?
Last updated: 2026-03-11
Post by kporter on Codesys EtherCAT Driver (CmpEt1000MPD) can't set MAC address
CODESYS Forge
talk
(Post)
EtherCAT is a point-to-point protocol so it doesn't need a unique MAC address. It would be very useful to set the MAC address to 020000000000, the standard address for this kind of application. (The important bit is the 02 at the start of the address, which means locally-administered MAC.) The stock Windows driver can do this for my i210 card. But the CODESYS CmpEt1000MPD driver cannot. The image shows the setting with the Windows driver. If I set all my customers' cards to this address, then I don't need to deal with this when deploying my application. A simple PowerShell script can be used to set the MAC address once when the NIC is installed and the driver is changed.
Last updated: 2026-02-09
Post by konstantin on CAM Motion Recover after STO
CODESYS Forge
talk
(Post)
Hello, one of the projects I work on is about a racetrack collator with two independent belts on it - two different servo motors. Both motors share the same mechanical frame and there is a train on a belt that collects items from the input conveyor. The way the motion is performed is the following - there is a virutal master axis and both real axis are synchronised with different cam motion profiles. The problem is when an STO is triggered on any of the slave axis, the synchronization process starts from position 0 of the slaves. How can I force the slaves to retain their current position until the master passes their position? Then the slaves should catch up with the master according to the profile, the slaves should not start synchronization from 0 position. Best Regards Konstantin Kolev
Last updated: 2026-02-12
Post by dat422 on CODESYS crashes when adding standard OPC UA Information Model to Communication Manager
CODESYS Forge
talk
(Post)
Hi all, I am experiencing a problem when trying to add a standard OPC UA Information Model to the Communication Manager. When I try to add the following standard information models to a new or existing project http://opcfoundation.org/UA (15.07.2020) http://opcfoundation.org/UA/DI (02.06.2020) CODESYS crashes every time during the process. Adding an OPC UA Server itself works without any problem. The crash only happens when adding the standard OPC UA Information Model. CODESYS version: CODESYS V3.5 SP20 Patch 4 (64 bit) Has anyone experienced the same issue or knows a possible workaround? Thank you in advance.
Last updated: 2026-03-19
Post by martinlithlith on CODESYS Control for Raspberry Pi SL on Raspberry Pi 4b
CODESYS Forge
talk
(Post)
hi! a quick question - is it possible to run CODESYS Control for Raspberry Pi SL license on a raspberry pi 4b? i know it says all models in the data sheet, but im not sure it the data sheet has been updated seince the MC-processors for pi. best, Martin
Last updated: 2023-09-04
Post by eschwellinger on Correct CAN Driver for EL6751
CODESYS Forge
talk
(Post)
Hi, for Control Win : add CmpEL6751CanDrv in the c:\ProgramData\CODESYS\CODESYSControlWinV3x64\E1FA7ABE\CODESYSControl.cfg [ComponentManager] Component.1=CmpTargetVisuStub Component.2=CmpWebServer Component.3=CmpWebServerHandlerV3 Component.4=SysCpuMultiCore Component.5=SysReadWriteLock Component.6=SysCpuBreakpoints Component.7=SysPipeWindows Component.8=CmpEL6751CanDrv for Linux SL or Pi or any ARM device - I think it is already static loaded as component - see plclogger on startup
Last updated: 2023-09-20
Post by derpaul on Official MQTT-Client: MAX_RECEIVE_BUFFER_SIZE_EXCEEDED
CODESYS Forge
talk
(Post)
I've post the Versions in the Attachments. It seems with htop, that there is a very high CPU Load. In the Log I can see nothing, as mentioned above I've to restart the PLC with Power off/on and the log in codesys was deleted. Or what do you mean with plclogger?
Last updated: 2023-09-23
Post by callumo1 on Check For Open Dialogs On Client
CODESYS Forge
talk
(Post)
Is it possible to make a function that checks to see if there are any open dialogs on a given clients. I think VisuDialogs.VisuDlgUtil_IsDialogOpen does this for a given dialog name, but is it possible to do this for any dialog. Appretiate any help Cheers Callum
Last updated: 2023-09-25
Post by transmin01 on SafetyApp - Exchange 8 bits from EtherCAT Safety Module to PLC mapping issue
CODESYS Forge
talk
(Post)
Hi, I am using an "Exchange 8 bits from EtherCAT Safety Module to PLC" module which allows me to create tags in the safety environment, but how does this map to the standard PLC program? There is no entry in the IoConfig_Globals variables list. Regards Trevor
Last updated: 2023-09-27
Post by rickj on Defining local variables that can be independent with several users.
CODESYS Forge
talk
(Post)
You need to create an array with one element for each possible user. I usually define these arrays in the root screen. FrameIndex : Array [0..MaxUsers] OF INT; Then use the global CurrentClientId (defined by one of the VISU libraries) to index the array element used to select the frame. FrameIndex[CurrentClientId]
Last updated: 2023-10-21
Post by chiali on Recipe issue.
CODESYS Forge
talk
(Post)
Hi Everyone, I'm trying to make a simple Recipe project using 'Save Recipe In File' and 'Load and Write Recipe' Execute Command buttons in Visualization but No dialog box 'Save As' appears when I click on buttons (Nothing happens). What is wrong. Please see the attached files. Best Regards, Chiali.
Last updated: 2023-10-23
Post by anhkdv on Data storage and Export in Codesys
CODESYS Forge
talk
(Post)
I am doing a SCADA project on temperature and humidity monitoring system. The customer requested that we store the database through codesys without the need for intermediary software such as MySQL, MSSQL,... and be able to export reports at selected times, reports exported to csv files. , xslm,... Can anyone help me?
Last updated: 2023-10-29
Post by ewi04 on Recipe Manager - RecipeManCommands, load & write wrong values, Bug?
CODESYS Forge
talk
(Post)
It seems that there is a limitation with the STRUCTs. Does anybody know, what’s okay to save (add to the recipe) and what’s not okay? Or is there another problem with my project? If I have only an array in the recipe definition everything works perfectly (see project).
Last updated: 2023-11-15
Post by leon78 on Codesys 3.5 SP17 Patch 2 CheckBounds (POUs for Implicit Checks)
CODESYS Forge
talk
(Post)
Unfortunately, it was fixed in SP19, but I need SP17 CDS-82162 Bug Compiler: Checkbounds is not working for dynamic arrays with VAR_IN_OUT as index access Fixed [[GENERAL]] Compilerversion >= 3.5.19.0 https://de.codesys.com/fileadmin/data/Images/System/Releaseinformation/Release-Notes-CODESYS-35190.html
Last updated: 2023-11-16
Post by ewi04 on Git - User identification data is lost when codesys is closed
CODESYS Forge
talk
(Post)
Hallo, it's not a big problem, but it is a bit annoying. The git user identification data is lost when codesys is closed. So I have to enter the information again and again. Is there a way to save the data? Environment: Codesys V3.5 SP19 Patch 4 (64Bit), Git 1.3.0.0 Thanks
Last updated: 2023-11-22
Post by simotion on Variable indicating axis pending gearing or camming
CODESYS Forge
talk
(Post)
Is there a variable indicating that a gearing or camming operation is pending? For instance MC_Gearin has beeen triggered, but starting point of master axis to start the sychronisation movement is not reached yet, so the slave axis is just waiting for this. I should be able to differ between a pending and active gearing or camming
Last updated: 2023-11-28
Post by hermsen on Raspberry Pi 4.12.0.0 SL also stops after 15s
CODESYS Forge
talk
(Post)
After installing this new 4.12.0.0 SL version on my RPi5 8GB and the latest bootloader, the runtime disappeared after 15secs. The bootloader my pi uses is from 2024-06-11. I was able to resolve this issue using this post: https://forge.codesys.com/forge/talk/Runtime/thread/be25c0ff66/ The workaround works for me.
Last updated: 2024-07-06
Post by charleskentyfz on (no subject)
CODESYS Forge
talk
(Post)
I have created an EtherCAT slave code and fixed two slaves (IDs written in the 0xF050 object dictionary). The module IDs are 0x1 and 0x101, respectively. It can be scanned normally in TwinCAT, but when scanning in CODESYS, it reports an error. Why is this happening?text in the second pic means 'device cannot be found in repository'