Post by pernockham on Trend legend naming and access/config to/of trend/legend-variables CODESYS Forge talk (Post)
Trying the web-version of trend-data. This seems to be a impressive tool, but I lack/cant find a number of what I would think are important parts. There does not seem to be a way to get away from the dot.notated variable naming in the legend.. A developer might want the dot-notation but an end-customer will surely not. For instance I want to display 12 temperatures, instead of t1, t2 etc.. they will be named. gvl_io.unit[1].trend.temps.t1_a gvl_io.unit[1].trend.temps.t1_b gvl_io.unit[1].trend.temps.t1_c gvl_io.unit[1].trend.temps.t2_a .. gvl_io.unit[1].trend.temps.t4_b.. gvl_io.unit[1].trend.temps.t4_c.. Quite a lot of unnecessary text/data taking space from the actual trend => Is there a way to access/interface the legend-data programmatically so I can change the presentation/naming?
Last updated: 2025-12-16

Post by stuartjr on Webvisu IE Page Scroll Bars CODESYS Forge talk (Post)
Is it possible to get scroll bars to show when displaying a web visualization in V2.3? I've got some big pages that I can scroll around when using the in-built visualization but when they are displayed in IE i can't seem to scroll around. All I can do it drag the window bigger onto my other display to get access to the extra area. I've also tried zooming the page out in IE but this doesn't seem to work at all.
Last updated: 2024-03-28

Post by nano on How to access to variable value through symbolic string name CODESYS Forge talk (Post)
i know, this is the reason for us either. PLC-Handler is to big, and only available with additional Contracts/Costs. OPC-UA is to slow for us. As described, there is a solution available, but im not allowed to post them here. i would prefer you send a message at codesys store by "have a question" or similar called. Not sure. Or, if an Codesys-Official Member allows to share that informations, i can give you the right hints.
Last updated: 2024-06-15

Post by ranadheer on Request to share documents about SoftPLC Extension SL CODESYS Forge talk (Post)
Hello Everyone Our team is planning to begin an industrial automation project and we are currently evaluating the use of SoftPLC Extension SL as a potential solution. As we are in the early stages and have yet to start the implementation, we kindly request access to official reference documents, technical manuals, and datasheets relating to SoftPLC Extension SL. Thank you very much for your assistance. We look forward to your response.
Last updated: 2025-10-18

Post by eschwellinger on RS485 CAN HAT to Cosesys CODESYS Forge talk (Post)
Hi if you add in (ttyAMA0 should fit to your HAT's device [SysCom] Linux.Devicefile.1=/dev/ttyAMA0 to /etc/CODESYSControl_Usr.cfg since 4.12.0.0 version /etc/codesyscontrol/CODESYSControl_Usr.cfg then access in CODESYS with Com1 should do it. Keep in mind that only adapters work (for RS485) which do determine the send/receive direction in hardware
Last updated: 2024-10-28

Post by timvh on Sysfile inuts CODESYS Forge talk (Post)
To prevent ambiguous use of this enumeration value. Let's say another ENUM is available in your project or in another library which has an enumeration value AM_WRITE, then it is not clear which AM_WRITE you want to assign. By this qualified access to the SysFile.AM_WRITE, it is completely clear for the compiler.
Last updated: 2024-01-14

Post by timvh on Limiting Memory Access of an Array to Within its Bounds CODESYS Forge talk (Post)
Add the object "POU for Implicit Checks" to your application, then select "Bounds check". This will create a function which is automatically called each time an array is write accessed. In the function you can handle "out of bounds" situations. By default it will be limited to its lower or upper bound.
Last updated: 2024-03-06

Post by nano on How to access to variable value through symbolic string name CODESYS Forge talk (Post)
this is not easily. From Point of SL-Licenses Codesys didnt provide the informations how to do. We created an own CDS-Component for that Behaviour. This Informations are available for OEM, if you are an OEM you can find the Informations in the RTS-Documentation.
Last updated: 2024-06-14

Post by rafael on Access to user group IDs CODESYS Forge talk (Post)
Hello, I'm trying to access the group IDs of the connected user. "CurrentUserGroupId" var shows only the first group ID that the user is assigned, I need the other group IDs that the user is in. I find some structs but I can't find where they are used, like "VUM_User" scruct from visuusermgmt, where can I find this vars? https://content.helpme-codesys.com/en/libs/VisuUserMgmt2%20Interfaces/Current/VUM_User.html abyUserGroupIDs seens perfect but I can't find a GVL where it is used.
Last updated: 2024-07-08

Post by ihatemaryfisher on Sorting array of any-sized structure CODESYS Forge talk (Post)
With that I could make an array of varying size, but would still have to define the array type in the function's declaration VAR_IN_OUT stArray: array [*..*] of <pre-defined data type> END_VAR I wanted a function that could take an array of any type (e.g., a structured VAR) as an input. That way I could call it in multiple POUs to handle different arrays structures.
Last updated: 2023-08-18

Post by ph0010421 on Help with __SYSTEM.VAR_INFO CODESYS Forge talk (Post)
hi all I have a FB with IN/OUT variable. Inside the FB, I want to get the address of the IN/OUT variable. If I use __SYSTEM.VAR_INFO, I get the address of the FB copy rather than 'external' variable. VAR_IN_OUT MyVar: bool; END_VAR VAR Info: __SYSTEM.VAR_INFO; END_VAR Info := __VARINFO(MyVar); This give me the address of MyVar but I actually want the address of the variable passed to MyVar Any clues please?? thanks, ph
Last updated: 2025-01-24

Post by eschwellinger on Generic EtherCAT slave CODESYS Forge talk (Post)
Sure, import the ESI file, scan the slave access the PDOs.
Last updated: 2024-05-14

Post by vsgn on Passing properties as VAR_IN_OUT variables. CODESYS Forge talk (Post)
Hi, in my experience, the best options for such a case could be: 1. Pass a FunctionBlock via VAR_IN_OUT, containing all variables, mehods and properties needed for the logic of this graphic element (be aware of implementing correcly both get and set accessor for properties) 2. Pass an Interface via VAR_INPUT, of which you can use obviously only Properties and Methods. This is much more elegant for me. Here, you can just pass directly the instance of a FunctionBlock implementing such Interface as input. Hope you'll find this suggestions useful.
Last updated: 2025-05-13

Unable to connect to this device CODESYS Forge talk (Thread)
Unable to connect to this device
Last updated: 2024-06-28

Cursor to move to a control CODESYS Forge talk (Thread)
Cursor to move to a control
Last updated: 2025-08-12

Post by danielbeers on Automation Server + Pi Gateway + PLC w/ CAN CODESYS Forge talk (Post)
Hello, I have a project using some EPEC PLC's. Some of them are programmable using Ethernet and some use CAN. We currently have a Raspberry Pi that is acting as a gateway to the Codesys Automation Server and is successfully working for the PLC's communicating over ethernet. I am trying to achieve a similar result for the PLC's that have only CAN access. I have PEAKCan drivers on the Pi, and can successfully send/receive messages. But the Gateway does not recognise the PLC when scanned from the Automation server online. Is there a library or service that exists to translate the CAN messaging, to the Edge Gateway, and be able to achieve remote access with the Automation Server? Or is this not possible without creating something custom? Cheers, Daniel
Last updated: 2024-09-22

Post by sawicpx on CANbus Remapping PDOs During Runtime CODESYS Forge talk (Post)
Hello, I am working on an application where I need to remap PDOs to a different CANopen object during runtime depending on what value is at a specific register. I have gotten to the point where I put the device into Preoperational State using the CIA405.NMT function. I then reconfigure the PDO 180x and 1a0x obejcts usings SDOs to point to a new canopen object on the device however when I go to restart the Device from PREOP to OP using the CIA405.NMT function the device is reset back to the original configuration as per the initial setup. I am wondering is there any way to change the PDOs at runtime is there some more functionaility I can access to do this. Any direction is appreciated!
Last updated: 2023-12-22

Post by timvh on Management of a PLC network from a remote station CODESYS Forge talk (Post)
Maybe the CODESYS HMI is a good solution. https://store.codesys.com/en/codesys-hmi-sl-bundle.html Run this on the remote main control station. In the HMI application you can add the data source manager and to this manager you can add Data sources. A data source has a reference to the PLC you want to connect to and can get access to the variables of the PLC application. You can then use these variables in the visualization of the HMI application.
Last updated: 2023-12-04

Post by fleaplc on FILE_OPERATION_DENIED CODESYS Forge talk (Post)
By using the CAA FILE library (FB FILE.Open) (raspberry pi, codesys 3.5.19.0) I always get the error FILE_OPERATION_DENIED The file exist, it has r/w/x access and path is correct... Some idea to fix it?
Last updated: 2023-09-25

Post by viktorr on ShareMemory library documentation CODESYS Forge talk (Post)
Hello, I was wondering if there was further documentation on the SharedMemory library in CodeSys outside of the code example provided, or maybe a way to access the source code of the shared memory implementation. Thank you in advance for any advice. - Viktor
Last updated: 2024-07-03

Post by timvh on Readable IO names CODESYS Forge talk (Post)
IF you create an ENUM {attribute 'qualified_only'} {attribute 'strict'} TYPE E_IO : ( FIRST := 0, SECOND := 1 ); END_TYPE You should be able to access the array items like: IOCard_OUTPUT[E_IO.FIRST]
Last updated: 2024-09-28

Post by navan on File access operation denied CODESYS Forge talk (Post)
Codesys V3.5.20.10 having issue open windows folder. Willing to know the [Sysfile] location in windows for V3.5.20.10 (32 bit) installation. kindly hep on this.
Last updated: 2024-11-05

Post by izzz on J1939 Protocol Last Version CODESYS Forge talk (Post)
Hello, how can I access the latest published 2025 or 2022 full version of protocol J1939-71? I would like to purchase the full document but I can't find it.
Last updated: 2025-07-31

Post by pernockham on Control for linux SL, 4.14.0.0 -> 4.15.0.0 breaks web page access. URL requires authentication CODESYS Forge talk (Post)
After enabling user management, then reverting to "legacy mode" for visu, the web is responding again also for versions later than 4.14.0.0.
Last updated: 2025-09-09

Post by spfollen on Access to the path *** is denied CODESYS Forge talk (Post)
Hello @eschwellinger, My project stopped working again. it would appear that this solution didn't resolve the problem perminantely. I deleted my alarm manager and the problem is no longer. When I put back in the Alarm Manager and my alarms the issue returns.
Last updated: 2024-02-03