Post by ricola on codesys sp20 opcua not working CODESYS Forge talk (Post)
Hi, same pb for me ! did you find a solution ? (I'm working on 2 raspberry pi ) The same project compiled for 4.8.0.0 runtime with CodeSys 3.5SP20 is working fine on one target, and on the other one, my UAexpert receives the same "BadIdentityTokenInvalid" and none is working on 4.11.0.0 either ... anybody ?
Last updated: 2024-08-11

Post by nano on ERROR: CodeMAccess2: Used CmRuntime 2.61.2705.500 is too old CODESYS Forge talk (Post)
the codemeter deb files are part of the runtime-sl-installatonfiles. so u can download the whole raspberry pi package from store-page, unzip it with a progam like 7zip, there you'll find a folder called dependencys i thing. here should the deb files placed
Last updated: 2024-09-18

Post by egau on Hard shutdown: no code on device after power on CODESYS Forge talk (Post)
Hi, thanks for the fast response :) Yes I Have a .err file. Sorry I forgot to upload it. It is a binary file though... "Runtime goes in exception before the shutdown ?" I think it goes into exception at the same time as the power is lost...
Last updated: 2024-10-03

Post by gabor-n on PNIO Connect Parameter Error CODESYS Forge talk (Post)
It's a bit confusing, the two RPI is the same (board, OS, runtime, programing with Codesys V3.5 SP20 P2) but the one has a codesyscontrol.cfg file and the other has a codesyscontrol_user.cfg file. Shouldn't be the same? And because I over Codesys 3.5 SP 12 this would be the '_user.cfg' for both. Attached...
Last updated: 2024-10-11

Post by jeroenaero on CodeSys Raspberry pi I2C driver not found CODESYS Forge talk (Post)
yes i took the library from another forum: https://forge.codesys.com/forge/talk/Runtime/thread/f1400b71b6/, it is made for the ads1115 but the ads1015 is almost the same device with same adresses i only changed the divide value of the analog value, because thats the only difference between the ads1115 and ads1015.
Last updated: 2024-11-07

Post by mtnkyr on Runtime Problem connecting to Keyence IV-500MA Camera CODESYS Forge talk (Post)
I have to use Keyence IV-500MA Camera for a project. Actually I can use physical connection but I tried to connect using Ethernet protocol so I added its EDS file but I took a lot of errors. Could you help me to solve this problem?
Last updated: 2024-12-26

Post by mtnkyr on Runtime Problem connecting to Keyence IV-500MA Camera CODESYS Forge talk (Post)
I have to use Keyence IV-500MA Camera for a project. Actually I can use physical connection but I tried to connect using Ethernet protocol so I added its EDS file but I took a lot of errors. Could you help me to solve this problem?
Last updated: 2024-12-26

Post by damian177 on Serialports in EdgeBox-RPI-200 CODESYS Forge talk (Post)
Hi, Two years ago i used EdgeBox-RPI-200 with Codesys and serial ports works fine. Now I try run the same application but only new runtime but serial ports doesnt works: I have two serial: /dev/ttyACM0 - RS485 /dev/ttyACM1 - RS232 and below configuration in my sudo nano /etc/CODESYSControl_User.cfg: [SysCom] Linux.Devicefile=/dev/ttyACM But it doesnt work. what can i do ?
Last updated: 2025-05-17

Post by blitz on Latch alarm variables from the PLC runtime CODESYS Forge talk (Post)
Hi, I have a question. Does anyone know a way to change latch alarm variables from the PLC runtime? In the help there is a method described: https://content.helpme-codesys.com/en/libs/AlarmManager/Current/Interfaces/pou-IAlarm3/SetLatchVarValue.html but I don’t know how to use it correctly.
Last updated: 2025-09-23

Post by snhatton on OPC UA: How to change NodeId ?! CODESYS Forge talk (Post)
You can change the node id by adding the following to /etc/CODESYSControl.cfg: [CmpOPCUAProviderIecVarAccess] CustomNodeName=MyPLC123 Then restart the runtime and the new Node name will appear with the connection. I don't know if it's possible to remove the |var| from the name. I hope this helps!
Last updated: 2023-12-11

Post by arwie on Possibility to deactivate CmpBlkDrvUdp CODESYS Forge talk (Post)
Is it possible to completely deactivate CmpBlkDrvUdp? I managed to practically deactivate it by setting MaxRouters=1 in [CmpRouter], but in the log there are warnings: !!!! No router instance found to assign network interface <interface>ether 6</interface> [CmpRouter] MaxRouters=1 0.MainNet=BlkDrvTcp [CmpBlkDrvTcp] Name=BlkDrvTcp Codesys Runtime 4.10.0.0 Is there a setting in [CmpBlkDrvUdp] which would deactivate it?
Last updated: 2023-12-12

Post by hfelek on *SOURCEPOSITION* App = [Application] area=0, offset = 0 on default example CODESYS Forge talk (Post)
Hello, I am trying to run CmpTemplate component provided by Codesys for version 3.5.17. I call MyExternalFunction from the component but I get error as shown below. I see component is loaded successfully on runtime logs. I feel like I am missing something basically.
Last updated: 2024-01-15

Post by superjojo2002 on Licensing info not available. CODESYS Forge talk (Post)
I just want to highlight, that we intend to use the codesys runtime on an embedded device that has no possibilites to connect any dongle devices to. It is an edge IO-Link master with an 1.6GHz ARM computer running inside that has an embedded linux running and a Docker container engine: https://www.hilscher.com/de/produkte/edge-gateways-mit-container-management/edge-io-link-master
Last updated: 2024-03-20

Post by idir93dz on Identifier 'IoDrvGPIO' not defined CODESYS Forge talk (Post)
Hello, After installing the pi runtime and creating a pi project, I get these errors: [ERROR] Untitled3: Application [Device: PLC Logic]: C0046: Identifier 'IoDrvGPIO' not defined [ERROR] Untitled3: Application [Device: PLC Logic]: C0080: Function block 'IoDrvGPIO' must be instantiated to be accessed [ERROR] Untitled3: Application [Device: PLC Logic]: C0004: 'IoDrvGPIO' is no component of 'IoDrvGPIO'
Last updated: 2024-04-10

Post by mehmetembedded on Linux ARM64 SL, GPIO Access CODESYS Forge talk (Post)
Hello. I am using TI AM64x evaluation board TMDS64EVM. It has 8 leds connected via I2C to SoC.I wanna control them via codesys GPIO device. Is that possible? If so how I can do it. I had no problem installing codesys runtime, and running program on device. But when it comes to GPIO access, It couldn’t make it.
Last updated: 2024-05-08

Post by mehmetembedded on Linux ARM64 SL, GPIO Access CODESYS Forge talk (Post)
Hello. I am using TI AM64x evaluation board TMDS64EVM. It has 8 leds connected via I2C to SoC.I wanna control them via codesys GPIO device. Is that possible? If so how I can do it. I had no problem installing codesys runtime, and running program on device. But when it comes to GPIO access, It couldn’t make it.
Last updated: 2024-05-08

Post by eschwellinger on Runtime on Raspberry pi5 stops after 15 seconds CODESYS Forge talk (Post)
Think this is bootloader related: Workaround: Use previous bootloader version cp /lib/firmware/raspberrypi/bootloader-2712/stable/pieeprom-2024-01-15.bin ./pieeprom.bin rpi-eeprom-config pieeprom.bin > bootconf.txt rpi-eeprom-config --out pieeprom-new.bin --config bootconf.txt pieeprom.bin sudo rpi-eeprom-update -d -f ./pieeprom-new.bin sudo reboot
Last updated: 2024-06-10

Post by superjojo2002 on Licensing info not available. CODESYS Forge talk (Post)
I updated the docker container runtime to version 4.11.0.0. and build the container with this "Dockerfile" FROM arm64v8/debian:11.6 RUN apt-get update RUN apt-get install -y wget sudo unzip libusb-1.0-0-dev procps ENV CDS_VERSION "4.11.0.0" ENV EDGE_VERSION "4.11.0.0" ENV URL "https://store-archive.codesys.com/ftp_download/3S/LinuxARM64/2302000039/$CDS_VERSION/CODESYS%20Control%20for%20Linux%20ARM64%20SL%20$CDS_VERSION.package" ENV EDGE_URL "https://store-archive.codesys.com/ftp_download/3S/EdgeGatewayLinux/000120/$EDGE_VERSION/CODESYS%20Edge%20Gateway%20for%20Linux%20$EDGE_VERSION.package" RUN wget --output-document=/tmp/codesys.package $URL && \ unzip -p /tmp/codesys.package '*codemeter*.deb' > /tmp/codemeter.deb && dpkg -i /tmp/codemeter.deb && \ unzip -p /tmp/codesys.package '*codesyscontrol*.deb' > /tmp/codesys.deb && dpkg -i /tmp/codesys.deb RUN wget --output-document=/tmp/edge.package $EDGE_URL && \ unzip -p /tmp/edge.package '*arm64.deb' > /tmp/edge.deb && dpkg -i /tmp/edge.deb EXPOSE 11740 1217 11743 ENTRYPOINT ["/bin/sh", "-c" , "/etc/init.d/codemeter start && /etc/init.d/codemeter-webadmin start && /etc/init.d/codesyscontrol start && /etc/init.d/codesysedge start && tail -f /dev/null"] Now cmu -x" returns root@sensoredge-field-netfield-produktmanagment:/# cmu -x cmu - CodeMeter Universal Support Tool. Version 8.00 of 2023-Nov-28 (Build 5967) for Linux/ARMHF 64-Bit Copyright (C) 2007-2023 by WIBU-SYSTEMS AG. All rights reserved. But still CODESYS development system reports that it needs a dongle and when I click install that "value cannot be null. Parameter name: containerToLicenses" It seems that Codemeter is forced to look for a dongle instead of a CMsoftcontainer. Can you confirm that CODESYS licensing works also when CODESYS is installed in a Docker container?
Last updated: 2024-03-21

Post by leandroct on Error reading files after runtime update from 4.0.0.0 to 4.8.0.0 CODESYS Forge talk (Post)
Since version 19 they changed how file access is handle. There are two solutions: 1. You change where the file is stored (need to go to: /PlcLogic/) 2. You can, if you don´t want to store at PlcLogic, add the following line in the CODESYSControl.cfg under [SysFile]: ForceIecFilePath=0 The CodesysControl.cfg is at C:\ProgramData\CODESYS\CODESYSControlWinV3x64\xxPROJECT_NUMBERxx\ Here the email they sent me: "with the 3.5.19 Version we changed how files are handled. See following issue: CDS-81506 - CODESYS Control SysFile system file access vulnerability. There are two solutions: 1. You change where the file is stored (need to go to: /PlcLogic/) 2. You can, if you don´t want to store at PlcLogic, add the following line in the CODESYSControl.cfg under [SysFile]: ForceIecFilePath=0 Here is the official release-note: [[COMPATIBILITY_INFORMATION]] With the activation of ForceIecFilePath the file access from IEC is now restricted to the configured paths only (file sandbox)! [SysFile] ForceIecFilePath=1 (new default) The standard path is the current directory, the PlcLogic subfolder or a configured path. Every file access outside of this path is configured via PlaceholderFilePath, for example access to temporary files or removable media: [SysFile] PlaceholderFilePath.1=/tmp, $TMP$ PlaceholderFilePath.2=/media/usb, $USB$ PlaceholderFilePath.2.Volatile=1 For more information see our tutorial FilePath & Placeholders. To restore the old behavior ForceIecFilePath may be configured as follows: [SysFile] ForceIecFilePath=0 BUT WE HIGHLY RECOMMEND TO LEAVE THIS SETTING AT ITS NEW DEFAULT VALUE! "
Last updated: 2024-05-07

Post by sivakov on CoDeSys Exception EIP Adapter CODESYS Forge talk (Post)
Hi, Got same problem, appeared after 4.3.1.0 update. Prabably problem is in performance. I am using virtual machine, so adding one more core and several GB to RAM still not solved, but atleast did system more stable. Try optimise your main program or set less task interval. Regards, I will be your mate in solving this mistery =)
Last updated: 2023-09-28

Post by anhkdv on Data storage and Export in Codesys CODESYS Forge talk (Post)
I am doing a SCADA project on temperature and humidity monitoring system. The customer requested that we store the database through codesys without the need for intermediary software such as MySQL, MSSQL,... and be able to export reports at selected times, reports exported to csv files. , xslm,... Can anyone help me?
Last updated: 2023-10-29

Post by leon78 on Codesys 3.5 SP17 Patch 2 CheckBounds (POUs for Implicit Checks) CODESYS Forge talk (Post)
Unfortunately, it was fixed in SP19, but I need SP17 CDS-82162 Bug Compiler: Checkbounds is not working for dynamic arrays with VAR_IN_OUT as index access Fixed [[GENERAL]] Compilerversion >= 3.5.19.0 https://de.codesys.com/fileadmin/data/Images/System/Releaseinformation/Release-Notes-CODESYS-35190.html
Last updated: 2023-11-16

Post by rschwager on GVL to SHMem CODESYS Forge talk (Post)
Hallo! Have some any idea to transfer whole GVL to Shared Memory? I also shared REATIN memory to shraed meory for making a Retain Backup System without USP in Linux on a FRAM. For an other Application we want to shared the whole GVL off obne part (e.g. GVL_Test). How cvan I get easy the Size and the Address for meory copy?
Last updated: 2024-07-09

Post by dengsberg on Disable Communications to 'Modbus_Server_COM_Port' from the logic CODESYS Forge talk (Post)
I have a serial Modbus RTU communicating to the Slave device. But when the control system is not in Run there is no power applied to one of the Modbus Devices. Can I enable / disable the communications to that Modbus Slave in the code based on my running mode, so I don't get all the errors?
Last updated: 2024-08-29

Post by codesysdave on CoDeSys 3.5 SP20 "No Offline Help installed" CODESYS Forge talk (Post)
What does this message mean, in the Errors/Messages box? "[ERROR] MyProjectName: No Offline Help installed" In CDS23, I used to be able to select a system function with the mouse, and press F1. Help and description would popup. How do I get so-called On-line Help installed?
Last updated: 2024-09-06