Post by rmaas on Fieldbus has lost synchronicity
CODESYS Forge
talk
(Post)
Hi, On a gantry system with 2 axis i am getting the following error: SMC_DI_FIELDBUS_LOST_SYNCRONICITY This happens random, sometimes it happens every 5 minutes and sometimes no error for 2 hours... The Setup: - Using codesys 3.5 SP20 with all latest libs... - Kontron AL Pi-Tron CM4 with Preempt realtime patch (Raspberry Pi 4) - Codesys runtime 4.11.0.0 (single core) - CODESYS Control for Raspberry Pi SL licensed - Softmotion + CNC + Robotics licensed - 2x Leadshine EL8-EC400 servo drives - Axis group for a 2-axis T-Gantry Ethercat network wiring: Ethercat master softmotion -> Beckhoff EK1100 -> Servo drive #1 -> Servo drive #2 Ethercat Cycle time = 4ms Max Jitter = 140~150 What i have tried so far: - changed the sync offset from 20% to 30% - changed ethercat task priority from 1 to 0 Running tasks: - Ethercat tast: Prio = 0, Interval = 4ms - Main task: Prio = 1, Interval = 8ms - Visu task: Prio = 31, Interval = 100ms - Softmotion planning task: Prio = 15, Freewheeling - 3 other default tasks that were created by AC_Persist Motion fb's are called in the ethercat task... Does anyone have an idea how to fix this? Any help is greatly appreciated!
Last updated: 2024-04-11
Post by nixola on CmpCharDevice blocks gpiochip access on Raspberry Pi 5 since update from SP18 to SP21
CODESYS Forge
talk
(Post)
Hi, I added the following lines to /etc/codesyscontrol/CODESYSControl_User.cfg: [CmpCharDevice] PermittedPath.0=/dev/i2c* PermittedPath.1=/dev/spidev* PermittedPath.2=/sys/class/gpio/* PermittedPath.3=/dev/gpiochip* However, I'm still unable to read or control GPIO pins from any CODESYS application. Specifically, setting the pin direction (and, thus, the IoDrvGpioSysfs driver configuration) fails, with a rather non-descript error in the logs: Description Component Setting direction failed for GPIO pin 586 IEC Update configuration failed from driver IoDrvGPIOSysfs CmpIoMgr I'm running CODESYS Control for Linux ARM64 SL version 4.21.0.0; it's running in rootless mode, as the codesyscontrol user, but said user is in the gpio group and can otherwise normally interact with GPIO, both via gpioset/gpioget and via the sysfs driver in /sys/class/gpio/. The system is a custom 64-bit Raspberry OS based distro, running on a Raspberry Pi CM5 on kernel 6.18.34 with PREEMPT_RT scheduling.
Last updated: 2026-07-21
Post by francescoc on Custom log CmpLog
CODESYS Forge
talk
(Post)
Hi, I am trying to create a log in my application. Since I cannot find any documentation regarding modifying the codesys configuration file to be able to log in ms, i tried to create a new log via CmpLog.LogCreate. Below is the part of the code where I create the logger and write a test string. In the log tab of codesys I actually see the new log that was created, but it is empty, and in the folder I cannot find any files. I can't find any detailed documentation. Can you guys give me support? Are there any examples? Thank you IF NOT FirstCycle THEN LogName:= 'LOGS/TestLog'; LogOptions.bEnable:= 1; LogOptions.iMaxEntries:= 5000; LogOptions.iMaxFiles:= 100; LogOptions.iMaxFileSize:= 5000; LogOptions.szName:= LogName; LogOptions.uiType:= CmpLog.LogTypes.LT_TIMESTAMP_RTC_HIGHRES; LogOptions.uiFilter:= CmpLog.LogClass.LOG_ALL; LogHandle:= CmpLog.LogCreate(pOptions := ADR(LogOptions), pResult:= ADR(Result)); LogHandle:= CmpLog.LogOpen(pszName:= LogName, pResult:= Result); Component_Manager.CMAddComponent2('TestLogNEW', 16#00000001, ADR(udiCmpIdNEW), 0); CmpLog.LogAdd2(LogHandle, udiCmpIdNEW, CmpLog.LogClass.LOG_INFO, 1, 1, 'Logger started...'); END_IF IF TestWrite THEN TestWrite:= FALSE; CmpLog.LogAdd2(LogHandle, udiCmpIdNEW, CmpLog.LogClass.LOG_INFO, 1, 1, 'Write test'); END_IF
Last updated: 2024-03-16
Post by tortilla on J1939 connection between two devices
CODESYS Forge
talk
(Post)
Hey, I'm pretty new to CoDeSys so I don't know a lot of things yet. I have to create a connection between two devices (CANbus - J1939 connection). The idea for now is to send a message from one to another (one operates on 3.5 SP11 the other one on 2.3) I watched a few videos, worked with the documentation and worked with chatGPT 4o and was able to build the attached file. This part is about the device on 3.5.11: I'm using the J1939LocalECUDiag, TransmitParameterGroup, TransmissionTrigger Function blocks to send the message but my TransmitPG.xBusy / .xDone never turns to True and therefore my message is not sent while TransmitPG.xExcecute is True. I added the two devices in the CANbus in the J1939Manager and addapted the options like I've seen in the documentation. Can anyone explain what's wrong with my code in this casse or give me advices how to properly create a connection between my two devices? Thanks in advance!
Last updated: 2024-05-23
Post by rossanoparis on CAN TX regression in Control for Raspberry Pi 4.21.0.0 with CAN API library (RX works, TX silently fails)
CODESYS Forge
talk
(Post)
Environment: Target: Revolution Pi (Kunbus RevPi), armv7l 32-bit OS: Raspbian GNU/Linux 9 (Stretch), kernel 4.19.95-rt38-v7 (SMP PREEMPT RT, built 2022-03-22) CAN: via SocketCAN (can0) Runtime: CODESYS Control for Raspberry Pi SL IDE: CODESYS V3.5 SP22 + patch 3 (previously V3.5 SP22 + patch 2, where everything worked with runtime 4.18.0.0) Library: CANBusAPI from the "CAN API" package, version 1.0.0.3 Summary: The setup worked correctly with V3.5 SP22 + patch 2 and runtime 4.18.0.0. After updating the IDE to SP22 + patch 3 and the runtime to 4.21.0.0, CAN transmission via the CANBusAPI library stopped working. Reception is unaffected. There are no error indications anywhere: the application runs normally and the CAN diagnosis reports a healthy bus. Systematic testing (below) shows the problem follows the runtime version, not the IDE update. Regression isolation: The same application (compiled under SP22 + patch 3, unchanged between tests) was downloaded to the same target with different runtime versions, changing only the runtime each time: 4.18.0.0: TX and RX both work 4.19.0.0: TX and RX both work 4.20.0.0: TX and RX both work 4.21.0.0: RX works, TX does not The behavior is fully reproducible in both directions (downgrading to 4.20 restores TX, upgrading to 4.21 breaks it again). Hardware, wiring, OS, project, and application code are identical across all tests. Diagnostic data (CANBusDiagnosis FB, while the application is transmitting on 4.21): ctSendCounter: incrementing normally ctTxErrorCounter: 0 ctRxErrorCounter: 0 eState: ERROR_FREE xBusAlarm: FALSE So the library accepts and counts the outgoing messages, no TX errors are reported, and the CAN controller state stays error-free, but the messages never reach the other nodes on the bus. Expected behavior: Messages sent via CANBusAPI (CANDriver / SendMessage) are transmitted on the bus, as with runtime versions up to and including 4.20.0.0. Notes: I am aware that the CAN API package (1.0.0.3, from 2016) is old; however, the regression is tied to the runtime version, since the identical binary works on 4.18-4.20. Questions: Is there a known change in CmpSocketCanDrv / CmpCAACanL2 between 4.20.0.0 and 4.21.0.0 that could affect TX via the CAN API library? Is runtime 4.21.0.0 still supported on Debian 9 Stretch (kernel 4.19, RT-patched), or is a newer OS required? If a minimum OS/kernel requirement was introduced with 4.21, is it documented?
Last updated: 2026-08-17
Post by martinlithlith on Device User Logon and No device is responding.. Pi4b codesys 3.5 SP19 2 + (64-bit)
CODESYS Forge
talk
(Post)
Hi! Im slowly starting to loose it and i need som help! After a few night of reading up and testing i´m still stuck as a rock and you guys and girls are my last resort for this project. Basic facts; Win 11 Codesys 3.5 SP19 2 + (64-bit) Raspberry pi 4 model b 2 gb Raspian release 11 aarch64 What keeps me up late at night; Username and Password when trying to connect to device and device only beeing connectable for a few seconds. Some of the things I have tried; Username and passord; Credientials from the raspberry Administrator Administrator admin admin Admin Admin administrator administrator Usernames and passwords that I sometimes use (this was a longshot i know, but i was running out of ideas and energy). :) Epand filesystem, activating i2c, spi, 1-wire I can start the gateway and start the runtime. I cant install the edgearm64, arm64 runtime package eventhough I guess i should, i get code [ERROR] Error output: dpkg: error processing archive /tmp/codesysedge_edgearm64_4.8.0.0_arm64.deb (--install): [ERROR] Error output: package architecture (arm64) does not match system (armhf) [ERROR] Error output: Errors were encountered while processing: [ERROR] Error output: /tmp/codesysedge_edgearm64_4.8.0.0_arm64.deb code as a respons. I have tried to Reset Origin Device - no change. I have tried to remove the /etc/CODESYSControl_User.cfg [CmpUserMgr] but i could not find it and i was not sure if i should add it instead but i did not want to mess somthing up. I have tried to create a second gateway with the specific ip if the pi, that did not help. Could it be that i´m currently connected to the pi through WIFI? I can ping the pi and I can connect and control it through VNC. When i scan to select gateway target (scan edge gateway) i find 17-21 devices but can find the pi throug the mac adress. I started of trying to use the "CODESYS Control for Raspberry Pi SL" (I have a license sience earlier) as i read somewhere that this could be used on a Pi4 as well but now i´m trying with the MC SL, no changes, same problem. Right now - gateway version 4.8.0.0 (edgearmHF, armhf), Runtime Package 4.5.0.0 (raspberry, armhf). Any sugestions are very welcome! As mentioned above, theese are some of the things that i have tried/done - but i have been going at this for a while. Best, Martin
Last updated: 2023-09-10
Post by dwpessoa on CNC Jumps G20 - SMC_NCInterpreter and long time to process
CODESYS Forge
talk
(Post)
I am studying and developing a Softmotion+CNC system for a machine that executes multiple pieces. The G code program is written by the machine operator and each cycle execute 1 piece. The programs are large, exceeding 1000 lines and using up to 8 axes (X, Y, Z, A, B, C, P and Q). The machine needs to run cyclically, executing N pieces (selected by the Operator)... so I tested it using Looping and counters (G36 G37 and G20) and it worked, but it takes a long time to process, and the more pieces I need, the longer the processing time and this is totally impracticable. I found this solution which was very good, and for a few cycles it works well, but for 99999 pieces of a program with 1000 lines, it doesn't work very well... Another solution I tested is to maintain the interpolator with an automatic restart, that is, I load the program without looping (without G20) and give it another start as soon as it finishes. This partially resolved it, but there is still a delay in processing SMC_NCInterpreter in each restart :(. Another solution I thought of is to manually create the SMC_GEOINFO structure and then reuse it, avoinding the Interpreter, but reading the documentation and checking the structure filled by standard blocks, I noticed that there doesn't seem to be a "JUMP" function in the structure! In other words, the SMC_NCInterpreter actually keeps copying and copying the program section for each jump (G20)... If I repeat a 10-line program 1000 times, I will have a structure with more than 10000 lines... possibly this is the cause of take so long to process. Has anyone ever had a problem like this? I believe the same thing happens with typical applications with manipulator robots using Codesys in continuous cycles, and I would like to know if there is any solution, or even if I am misinterpreting the G20 question in SMC_GEOINFO. Thanks!
Last updated: 2023-09-20
Post by bjarne-pagaard on Communication between applications on same device/controller/runtime (Win RTE 3.5.20.20)
CODESYS Forge
talk
(Post)
Thanks for this - I have now been looking in to just having an extra (non-RTE) runtime on the same machine, as you suggest. I will probably proceed this way. Even though it still seems very odd to me, that variable exchange to a different runtime is easier than between applications on the same controller. There will be some fun with the licensing, it seems. Does anyone know if it is possible to specify which license container/specific license the runtime is going to use at runtime. Let's say I have two available licenses with different resources available, for example one license allows multicore and multiple EtherCAT channels, but not many visu tags (for the RTE). Another with less resources but a lot of visu tags (for the Visu controller). Let's say the program in one of the controllers could be fully licensed by either of the two available licenses, but picks the 'largest' first. A bit later, the larger application starts, but is left with the smaller license.. How can I make sure that the 2 runtimes select the right license at startup?
Last updated: 2024-10-01
Post by svenkaro on Codesyscontrol.service stoppt nach 30s
CODESYS Forge
talk
(Post)
Hallo nano, anbei das Logfile ;********* ;<loggername>codesyscontrol.log</loggername> ;<logoptions> ; <enable>1</enable> ; <type>normal</type> ; <timestamp>rtc high resolution</timestamp> ; <deactivatable>0</deactivatable> ; <dump>always</dump> ; <filter>0x0000000f<filter> ; <maxentries>100000</maxentries> ; <maxfiles>1</maxfiles> ; <maxfilesize>1000000</maxfilesize> ;</filter></filter></logoptions> ;<entries> ;Timestamp, CmpId, ClassId, ErrorId, InfoId, InfoText ;ClassId: LOG_INFO =1 ;ClassId: LOG_WARNING =2 ;ClassId: LOG_ERROR =4 ;ClassId: LOG_EXCEPTION =8 ;ClassId: LOG_DEBUG =16 ;ClassId: LOG_PRINTF =32 ;ClassId: LOG_COM =64 ;</entries> ;********* 2024-06-20T06:07:12.085Z, 0x0000013d, 16, 0, 0, OpenCpusetCpusEffective: using core(s) "0-3" from /sys/fs/cgroup/cpuset.cpus.effective 2024-06-20T06:07:12.085Z, 0x00000109, 16, 0, 0, SysModuleLoad: libCmpBACnet.so: 0x92ae530 2024-06-20T06:07:12.085Z, 0x00000109, 16, 0, 0, SysModuleLoad: libCmpBACnet2.so: 0x92af008 2024-06-20T06:07:12.085Z, 0x00000109, 16, 0, 0, SysModuleLoad: libCmpPLCHandler.so: 0x92afb08 2024-06-20T06:07:12.085Z, 0x00000109, 16, 0, 0, SysModuleLoad: libCmpGwClient.so: 0x92affe8 2024-06-20T06:07:12.085Z, 0x00000109, 16, 0, 0, SysModuleLoad: libCmpXMLParser.so: 0x92b04c0 2024-06-20T06:07:12.085Z, 0x00000109, 16, 0, 0, SysModuleLoad: libCmpGwClientCommDrvTcp.so: 0x92b09a0 2024-06-20T06:07:12.086Z, 0x00000013, 1, 0, 0, <logoptions> 2024-06-20T06:07:12.086Z, 0x00000013, 1, 0, 0, <benable>1</benable> 2024-06-20T06:07:12.086Z, 0x00000013, 1, 0, 0, <type>normal</type> 2024-06-20T06:07:12.086Z, 0x00000013, 1, 0, 0, <timestamp>rtc high resolution</timestamp> 2024-06-20T06:07:12.086Z, 0x00000013, 1, 0, 0, <disableable>0</disableable> 2024-06-20T06:07:12.086Z, 0x00000013, 1, 0, 0, <filter>0x0000000f</filter> 2024-06-20T06:07:12.086Z, 0x00000013, 1, 0, 0, <maxentries>100000</maxentries> 2024-06-20T06:07:12.086Z, 0x00000013, 1, 0, 0, <maxfiles>1</maxfiles> 2024-06-20T06:07:12.086Z, 0x00000013, 1, 0, 0, <maxfilesize>1000000</maxfilesize> 2024-06-20T06:07:12.086Z, 0x00000013, 1, 0, 0, </logoptions> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>CM</cmp>, <id>0x00000001</id> <ver>3.5.19.61</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>CmpMemPool</cmp>, <id>0x0000001e</id> <ver>3.5.19.60</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>CmpLog</cmp>, <id>0x00000013</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>CmpSettings</cmp>, <id>0x0000001a</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysFile</cmp>, <id>0x00000104</id> <ver>3.5.19.50</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>CmpMemGC</cmp>, <id>0x0000001f</id> <ver>3.5.19.20</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysCom</cmp>, <id>0x00000100</id> <ver>3.5.19.10</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysCpuHandling</cmp>, <id>0x00000101</id> <ver>3.5.19.20</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysCpuMultiCore</cmp>, <id>0x0000013d</id> <ver>3.5.19.20</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysCrypto</cmp>, <id>0x00000141</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysDir</cmp>, <id>0x0000011b</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysEthernet</cmp>, <id>0x0000011c</id> <ver>3.5.19.20</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysEvent</cmp>, <id>0x00000102</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysExcept</cmp>, <id>0x00000103</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysInternalLib</cmp>, <id>0x00000107</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysMem</cmp>, <id>0x00000108</id> <ver>3.5.19.50</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysModule</cmp>, <id>0x00000109</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysMsgQ</cmp>, <id>0x0000010a</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysMutex</cmp>, <id>0x0000013a</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysOut</cmp>, <id>0x0000010b</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysProcess</cmp>, <id>0x0000010e</id> <ver>3.5.19.50</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysSem</cmp>, <id>0x0000010f</id> <ver>3.5.19.10</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysSemCount</cmp>, <id>0x00000139</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysSemProcess</cmp>, <id>0x00000119</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysShm</cmp>, <id>0x00000110</id> <ver>3.5.19.50</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysSocket</cmp>, <id>0x00000111</id> <ver>3.5.19.30</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysTarget</cmp>, <id>0x00000112</id> <ver>3.5.19.61</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysTask</cmp>, <id>0x00000114</id> <ver>3.5.19.10</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysTime</cmp>, <id>0x00000115</id> <ver>3.5.19.10</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysTimeRtc</cmp>, <id>0x00000127</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysTimer</cmp>, <id>0x00000116</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpAlarmManager</cmp>, <id>0x0000007c</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpApp</cmp>, <id>0x00000002</id> <ver>3.5.19.60</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpAppBP</cmp>, <id>0x00000073</id> <ver>3.5.19.20</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpAppForce</cmp>, <id>0x00000074</id> <ver>3.5.19.20</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpAsyncMgr</cmp>, <id>0x0000005f</id> <ver>3.5.19.20</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpAuditLog</cmp>, <id>0x000000a1</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpBinTagUtil</cmp>, <id>0x00000004</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpBinTagUtilIec</cmp>, <id>0x0000005c</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpBitmapPool</cmp>, <id>0x00000050</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpBlkDrvTcp</cmp>, <id>0x00000030</id> <ver>3.5.19.50</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpBlkDrvUdp</cmp>, <id>0x00000007</id> <ver>3.5.19.30</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAAAsyncMan</cmp>, <id>0x00004007</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAABehaviourModel</cmp>, <id>0x00004015</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAACallback</cmp>, <id>0x00004001</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAACanL2</cmp>, <id>0x00004004</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAADTUtil</cmp>, <id>0x00004013</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAAFile</cmp>, <id>0x00004008</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAAMemBlockMan</cmp>, <id>0x00004003</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAANetBaseServices</cmp>, <id>0x00004018</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAARealTimeClock</cmp>, <id>0x00004014</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAASdoClient</cmp>, <id>0x00004011</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAASdoServer</cmp>, <id>0x00004017</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAASegBufferMan</cmp>, <id>0x00004019</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAASerialCom</cmp>, <id>0x00004012</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAAStorage</cmp>, <id>0x0000007e</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAATick</cmp>, <id>0x00004009</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAATickUtil</cmp>, <id>0x00004010</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAATimer</cmp>, <id>0x00004016</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAATypes</cmp>, <id>0x00004006</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpChannelClient</cmp>, <id>0x00000008</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpChannelClientIec</cmp>, <id>0x0000005d</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpChannelMgr</cmp>, <id>0x00000009</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpChannelServer</cmp>, <id>0x0000000a</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCharDevice</cmp>, <id>0x00000300</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpChecksum</cmp>, <id>0x0000000b</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCodeMeter</cmp>, <id>0x0000007a</id> <ver>3.5.19.50</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCommunicationLib</cmp>, <id>0x0000000c</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCoreDump</cmp>, <id>0x00000083</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCryptMD5</cmp>, <id>0x0000006a</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpDevice</cmp>, <id>0x0000000e</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpDynamicText</cmp>, <id>0x00000051</id> <ver>3.5.19.30</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpEL6751CanDrv</cmp>, <id>0x00005f0b</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpEventMgr</cmp>, <id>0x0000005b</id> <ver>3.5.19.30</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpEventMgrUnixBackend</cmp>, <id>0x000000a4</id> <ver>4.11.0.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpFileTransfer</cmp>, <id>0x0000005e</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpIecStringUtils</cmp>, <id>0x0000007f</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpIecTask</cmp>, <id>0x00000011</id> <ver>3.5.19.30</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpIecVarAccess</cmp>, <id>0x00000060</id> <ver>3.5.19.30</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpIoDrvIec</cmp>, <id>0x0000005a</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpIoMgr</cmp>, <id>0x00000012</id> <ver>3.5.19.30</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpKnxStack</cmp>, <id>0x0000004d</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpLinuxInterrupt</cmp>, <id>0x000000a2</id> <ver>3.5.17.10</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpLinuxRTDiag</cmp>, <id>0x000000a7</id> <ver>4.11.0.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpMonitor2</cmp>, <id>0x00000032</id> <ver>3.5.19.20</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpNameServiceClient</cmp>, <id>0x00000015</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpNameServiceClientIec</cmp>, <id>0x0000011d</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpNameServiceServer</cmp>, <id>0x00000016</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpOPCUAClient</cmp>, <id>0x00000096</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpOPCUAProviderIecVarAccess</cmp>, <id>0x00000126</id> <ver>3.5.19.50</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpOPCUAServer</cmp>, <id>0x00000124</id> <ver>3.5.19.30</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpOPCUAStack</cmp>, <id>0x0000008d</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpOpenSSL</cmp>, <id>0x00000033</id> <ver>3.5.19.61</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpPlcShellLinux</cmp>, <id>0x00000128</id> <ver>4.11.0.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpPlcShellLinuxBackend</cmp>, <id>0x000000a5</id> <ver>4.11.0.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpRasPi</cmp>, <id>0x00000089</id> <ver>4.11.0.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpRedundancy</cmp>, <id>0x00000129</id> <ver>3.5.19.30</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpRedundancyConnectionIP</cmp>, <id>0x0000ff03</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpRetain</cmp>, <id>0x00000017</id> <ver>3.5.19.50</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpRouter</cmp>, <id>0x00000018</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpRunStopSwitch</cmp>, <id>0x000000a6</id> <ver>4.11.0.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpSchedule</cmp>, <id>0x00000019</id> <ver>3.5.19.50</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpSecureChannel</cmp>, <id>0x00000090</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpSecurityManager</cmp>, <id>0x0000008e</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpSessionInformation</cmp>, <id>0x00000097</id> <ver>3.5.19.20</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpSocketCanDrv</cmp>, <id>0x00005f0d</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpSocketUnix</cmp>, <id>0x000000a3</id> <ver>4.11.0.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpSrv</cmp>, <id>0x0000001c</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpTraceMgr</cmp>, <id>0x00000070</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpUserDBFile</cmp>, <id>0x00000098</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpUserGroupsDBFile</cmp>, <id>0x00000099</id> <ver>3.5.19.50</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpUserMgr</cmp>, <id>0x00000061</id> <ver>3.5.19.50</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpUserObjectsDBFile</cmp>, <id>0x0000009c</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpVisuHandler</cmp>, <id>0x00000054</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpVisuServer</cmp>, <id>0x00000057</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpWebServer</cmp>, <id>0x00000071</id> <ver>3.5.19.30</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpWebServerHandlerV3</cmp>, <id>0x00000072</id> <ver>3.5.19.10</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, Dynamic: <cmp>CmpBACnet</cmp>, <id>0x00000400</id> <ver>3.5.19.50</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, Dynamic: <cmp>CmpBACnet2</cmp>, <id>0x00000401</id> <ver>3.5.19.10</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, Dynamic: <cmp>CmpPLCHandler</cmp>, <id>0x0000002a</id> <ver>3.5.19.61</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, Dynamic: <cmp>CmpGwClient</cmp>, <id>0x00000021</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, Dynamic: <cmp>CmpXMLParser</cmp>, <id>0x00000058</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, Dynamic: <cmp>CmpGwClientCommDrvTcp</cmp>, <id>0x00000022</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.125Z, 0x0000013d, 1, 0, 4, MultiCore support: [activated], all cores are used 2024-06-20T06:07:12.125Z, 0x0000013d, 1, 0, 4, Number of available cores: 4 2024-06-20T06:07:12.134Z, 0x00000401, 2, 0, 0, !!!! Warning: component CmpBACnet loaded already 2024-06-20T06:07:12.184Z, 0x00000007, 1, 0, 6, Network interface: <ipaddress>10.94.25.39</ipaddress>, subnetmask <subnetmask>255.255.255.0</subnetmask> 2024-06-20T06:07:12.184Z, 0x00000018, 1, 0, 4, Network interface <interface>ether 2</interface> at router <instance>0</instance> registered 2024-06-20T06:07:12.185Z, 0x00000009, 1, 0, 2, Running as network server 2024-06-20T06:07:12.185Z, 0x00000009, 1, 0, 1, Running as network client 2024-06-20T06:07:12.186Z, 0x0000000a, 1, 0, 0, <numofchannels>4</numofchannels> channels available, each of the size <buffersize>100000</buffersize> Bytes 2024-06-20T06:07:12.254Z, 0x00000400, 1, 0, 0, CmpBACnet 1024 BACstack information 2024-06-20T06:07:12.254Z, 0x00000400, 1, 0, 0, version = 15.0.1.1 2024-06-20T06:07:12.254Z, 0x00000400, 1, 0, 0, __BYTE_ORDER = 1234 2024-06-20T06:07:12.254Z, 0x00000400, 1, 0, 0, TARGET_IEEE_FP_FORMAT = 1 2024-06-20T06:07:12.254Z, 0x00000400, 1, 0, 0, TARGET_FP_BIG_ENDIAN = 0 2024-06-20T06:07:12.254Z, 0x00000400, 1, 0, 0, TARGET_DP_BIG_ENDIAN = 0 2024-06-20T06:07:12.254Z, 0x00000400, 1, 0, 0, TARGET_INTEGRAL_BIG_ENDIAN = 0 2024-06-20T06:07:12.254Z, 0x00000400, 1, 0, 0, TARGET_USED_ALIGNMENT = 4 2024-06-20T06:07:12.254Z, 0x00000401, 1, 0, 0, CmpBACnet2 1025 BACstack information 2024-06-20T06:07:12.254Z, 0x00000401, 1, 0, 0, version = 25.1.5.1 2024-06-20T06:07:12.254Z, 0x00000401, 1, 0, 0, __BYTE_ORDER = 1234 2024-06-20T06:07:12.254Z, 0x00000401, 1, 0, 0, TARGET_IEEE_FP_FORMAT = 1 2024-06-20T06:07:12.254Z, 0x00000401, 1, 0, 0, TARGET_FP_BIG_ENDIAN = 0 2024-06-20T06:07:12.254Z, 0x00000401, 1, 0, 0, TARGET_DP_BIG_ENDIAN = 0 2024-06-20T06:07:12.254Z, 0x00000401, 1, 0, 0, TARGET_INTEGRAL_BIG_ENDIAN = 0 2024-06-20T06:07:12.254Z, 0x00000401, 1, 0, 0, TARGET_MCU_USED_ALIGNMENT = 4 2024-06-20T06:07:12.261Z, 0x00000129, 1, 0, 0, Debug Messages not activated 2024-06-20T06:07:12.262Z, 0x0000ff03, 1, 0, 0, Read connection settings... 2024-06-20T06:07:12.266Z, 0x00000030, 1, 0, 6, Local network address: <ipaddress>10.94.25.39</ipaddress> 2024-06-20T06:07:12.266Z, 0x00000018, 1, 0, 4, Network interface <interface>BlkDrvTcp</interface> at router <instance>1</instance> registered 2024-06-20T06:07:12.272Z, 0x00000124, 1, 0, 0, No certificate for the OPC UA server available. 2024-06-20T06:07:12.272Z, 0x00000124, 1, 0, 0, Security policy allows plain text communication. Secure communication is deactivated. 2024-06-20T06:07:12.272Z, 0x00000124, 1, 0, 0, ********** 2024-06-20T06:07:12.272Z, 0x00000124, 1, 0, 0, OPC UA Server Started: 2024-06-20T06:07:12.272Z, 0x00000124, 1, 0, 0, Hostname: raspberrypi, Port: 4840 2024-06-20T06:07:12.272Z, 0x00000124, 1, 0, 0, URL: opc.tcp://raspberrypi:4840 2024-06-20T06:07:12.272Z, 0x00000124, 1, 0, 0, Loopbackadapter activated. 2024-06-20T06:07:12.272Z, 0x00000124, 1, 0, 0, All available networkadapters are used. 2024-06-20T06:07:12.272Z, 0x00000124, 1, 0, 0, Multithreading activated. 3 workers used. 2024-06-20T06:07:12.272Z, 0x00000124, 1, 0, 0, ************ 2024-06-20T06:07:12.286Z, 0x00000124, 1, 0, 0, Provider 'CODESYS_DefaultProvider' (version 0x305131e) registered at the OPC UA server. 2024-06-20T06:07:12.287Z, 0x000000a6, 1, 0, 0, Not able to read file of Run/Stop switch. Functionality of component disabled 2024-06-20T06:07:12.306Z, 0x00000001, 1, 0, 0, ========================================================================= 2024-06-20T06:07:12.306Z, 0x00000001, 1, 0, 4, CODESYS Control for Raspberry Pi MC SL 2024-06-20T06:07:12.306Z, 0x00000001, 1, 0, 4, OS=Linux, CPU=ARM, Arch=32Bit, Coding=C 2024-06-20T06:07:12.306Z, 0x00000001, 1, 0, 6, <version>3.5.19.61</version> <builddate>Feb 22 2024</builddate> 2024-06-20T06:07:12.306Z, 0x00000001, 1, 0, 5, Copyright CODESYS Development GmbH 2024-06-20T06:07:12.306Z, 0x00000001, 1, 0, 0, ========================================================================= 2024-06-20T06:07:12.308Z, 0x00000124, 1, 0, 0, Provider 'AddressSpaceFragment Provider' (version 0x3051332) registered at the OPC UA server. 2024-06-20T06:07:12.309Z, 0x00000124, 1, 0, 0, Provider 'OPC UA for IEC-61131-3' (version 0x3051332) registered at the OPC UA server. 2024-06-20T06:07:12.309Z, 0x00000124, 1, 0, 0, Provider 'AlarmManager' (version 0x3051332) registered at the OPC UA server. 2024-06-20T06:07:12.321Z, 0x00000018, 1, 0, 1, Setting router <instance>0</instance> address to (0027) 2024-06-20T06:07:12.321Z, 0x00000018, 1, 0, 1, Setting router <instance>1</instance> address to (2ddc:0a5e:1927) 2024-06-20T06:07:12.332Z, 0x00000001, 1, 0, 34, CODESYS Control ready 2024-06-20T06:07:12.333Z, 0x00000001, 2, 0, 0, !!!! Warning: no runtime license - running in demo mode(~2 hours) Wäre der Zeitraum nicht nur 30s könnte ich das beenden auf Grund der letzten Zeile nachvollziehen. Hoffe Du hast eine Idee, vielen Dank.
Last updated: 2024-06-20
Post by janderson on OPC UA Server limitations, large array crashes runtime
CODESYS Forge
talk
(Post)
What are the limitations of the OPC UA Server? I am trying to get data off my PLC that is acquired at high rates (~50k samples/s) so I am storing them in arrays and trying to get the arrays off the PLC. When I attempt to read a ~200k element array through OPC UA the server and runtime crashes (requiring tools -> update linux arm64 -> start runtime). Is there a better way to get highspeed data off? The ACDatalog library seems a bit irritating to use so I would prefer to go through OPC UA.
Last updated: 2023-08-23
Post by xiaolo on Raspberry Pi 5
CODESYS Forge
talk
(Post)
Does Ver. 4.12 support Raspberry Pi 5? I have three issues. The first issue is that Codesys cannot detect the RPI 5 when I want to download the runtime. When assigning the IP Address manually then I can download the runtime. The second issue is that I cannot connect to the RPI to download a program. Sometimes the window pops up and it ask for the user credentials, but it is still not connecting. The third issue is that I cannot connect to an ESP32 configured as a Modbus Slave with a Raspberry Pi 4B. I can connect to the ESP32 via a Radzio! Modbus Master Simulator. I am also missing the function Write Holding Registers in the setup of the slave. Are this known issues and when it will be solved?
Last updated: 2024-07-12
Post by pernockham on How to manage soft container licenses for (remote) multi units?
CODESYS Forge
talk
(Post)
Using Codesys runtime for Linux and thinking of the process of preparing multiple such systems for my customer. I don't necessarily have physical access to these units, they can be (very) remote. The idea so far is to use an image to install the Linux OS and codesys runtime. Application updates can be done by distribution of the PlcLogic/Application/application.app and application.crc files. But whats the most practical way of managing the license for these units? Do each controller need to be physically connected to a License Manager instance or can licenses be distributed by means of a license file for each unit? I believe that the license should be stored in soft containers for each unit. Help and insights appreciated! Per
Last updated: 2025-04-04
Post by preimesbergert on Raspberry Pi 4 B HW 1.5 Codesys control 4.10.0 stopps after a few seconds
CODESYS Forge
talk
(Post)
Wanted to play a bit with a raspberry Pi 4 Model B HW 1.5 and Codesys. Regardless of the image (tried 32bit / 64bit version from Raspberry Pi Imager) and with all tested Codesys Control versions (4.2.0, 4.8.0, 4.10.0) and regardless if single core / multicore / 64 bit variant, always is the runtime stopped after about 30sec with the nice message: ooops... this runtime was built for RASPBERRYPI. Hardware version or firmware version not supported! (-7, 0x00000BB8, 0xFFFFFFFB) Whats wrong with it?!?!? I read a lot about the issue in topics from 2020-2021 but it always was stated with new Codesys control version issue will be fixed (4.4 for example) but still it is there.
Last updated: 2023-12-21
Post by preimesbergert on Raspberry Pi 4 B HW 1.5 Codesys control 4.10.0 stopps after a few seconds
CODESYS Forge
talk
(Post)
Wanted to play a bit with a raspberry Pi 4 Model B HW 1.5 and Codesys. Regardless of the image (tried 32bit / 64bit version from Raspberry Pi Imager) and with all tested Codesys Control versions (4.2.0, 4.8.0, 4.10.0) and regardless if single core / multicore / 64 bit variant, always is the runtime stopped after about 30sec with the nice message: ooops... this runtime was built for RASPBERRYPI. Hardware version or firmware version not supported! (-7, 0x00000BB8, 0xFFFFFFFB) Whats wrong with it?!?!? I read a lot about the issue in topics from 2020-2021 but it always was stated with new Codesys control version issue will be fixed (4.4 for example) but still it is there.
Last updated: 2023-12-21
Post by mondinmr on Shared Memory Access Issues
CODESYS Forge
talk
(Post)
In Windows I need create shared memory in PC software and connect from CODESYS. If shm is not GLOBAL doesn't work due different users between runtime and PC software. PC software need admin privileges. Name need "Global\\" before key. Very unsafe!!! If CODESYS create shared I cannot find key PC side. In Linux I can create shared memory as standard user, bind in the runtime docker, use keys without any "Global\\". Much more safe!!! If CODESYS create shared you need play with permissions to use app as standard user. I prefer create form PC software as standard user.
Last updated: 2024-01-30
Post by valenting on Runtime not working on raspberry pi Bullseye
CODESYS Forge
talk
(Post)
Hello I have a problem with Codesys on Raspberry pi with Bullseye The device is not recognized as a Raspberry pi, as I get this error : ooops... this runtime was built for RASPBERRYPI. Hardware version or firmware version not supported! (-18, 0x00000BB8, 0xFFFFFFFB) I'm running Codesys on a compute module 4S with Raspbian GNU/Linux 11 (bullseye), my kernel version is Linux 5.10.90-v7l+ Codesys version is the latest, released last week (4.11.0.0, CODESYS Control V3.5.19.61 for ARM-32Bit - build Feb 22 2024) I know it works on the same device if I use Raspbian 10 (Buster) with Linux 5.4.81-v7l+ kernel, but for some other reasons I have to use Bullseye. What can I do ?
Last updated: 2024-03-01
Post by valec on Connect local Asem HMI runtime to local Codesys Control Win V3 x64
CODESYS Forge
talk
(Post)
I have a project made on a PL700 PLC with Codesys and an Asem Premium HMI panel. I don't have access to the physical PLC right now, so I'm trying to use Codesys Control Win V3 x64. I created the application and loaded "Codesys Control Win V3 x64" without errors, then I activate "Start PLC" from the tray. Asem cannot connect. I tried to use "localhost" or the local IP address and it doesn't work (it's the "CoDeSys Soft PLC Communication Driver"). I need to connect my local Asem runtime to a virtual Codesys application on my PC. How can I do it?
Last updated: 2024-03-26
Post by eschwellinger on CmpCharDevice blocks gpiochip access on Raspberry Pi 5 since update from SP18 to SP21
CODESYS Forge
talk
(Post)
yes, this is a known issue which will be fixed with 3.5.23.0 .. soll will take some time. You need to switch back the runtime running not as dedicated user, like it was before 4.21.0.0 How to switch back you'll find here. ('Change service user' in the deploy tool) https://content.helpme-codesys.com/en/CODESYS%20Control/_rtsl_linux_dedicated_user.html to sumerize both problems: 1. missing entries in CODESYSControl_Usr.cfg was the problem on Raspberry PI Runtime 2. Arm64 SL is running rootless by default since 4.21.0.0 ( Pi not by default you need to switch manually if needed due this GPIO restriction)
Last updated: 2026-07-22
Post by jp0951269346 on How to reset forgotten User Management / Administrator password on CODESYS Control Win V3 (V3.5 SP22 Patch 2)?
CODESYS Forge
talk
(Post)
Hi everyone, I forgot the Administrator credentials for my local Soft PLC (CODESYS Control Win V3x64) running on CODESYS V3.5 SP22 Patch 2 (Windows 11). When I try to login/connect to the device, it asks for the Device User Management username and password. I checked the CODESYSControl.cfg file, which points the working directory to: Windows.WorkingDirectory=%APPDATA%\CODESYS\CODESYSControlWinV3x64\905D4E32 However, I cannot locate the actual database/credentials files in AppData or ProgramData to clear them, and resetting the runtime directory doesn't seem to clear the authentication prompt. Could anyone please advise the correct steps to completely reset or wipe the User Management credentials for the Control Win V3.5 SP22 runtime? Thank you in advance!
Last updated: 5 days ago
Post by cd-tt on cannot connect ot linux runtime: device does not answer the scanrequest
CODESYS Forge
talk
(Post)
I have the following setup: Proxmox PC with a debian 13 VM running CODESYS Control Linux SL and Edge Gateway. Installation method was through the Deploy Control SL and went rather smoothly. In my Device Tab I find the gateway and when scanning my network I also find my runtime. I want to connect and get promted that I should add a user. After setting up the user I get an error saying, that the device is not responding my scanrequest. Deploy Control SL Operation saying everythings up and running. I can confirm that from the terminal on the VM with "systemctl status codesyscontrol" and "systemctl status codesysgateway". I am running out of ideas how to fix that issue. Can anybody help? Screenshots attached.
Last updated: 2026-06-11
Post by toffeebonbon on Die richtige CODESYS-Runtime auf dem Raspberry Pi ausrollen (3.5 SP18)
CODESYS Forge
talk
(Post)
Guten Morgen, wie der Titel verrät soll es hier um das Ausrollen der CODESYS Runtime auf einem Raspberry Pi gehen. Ob ein klassischer Raspberry Pi aus dem Consumer-Bereich oder ein Compute-Modul spielt in dem Fall keine Rolle. Ich möchte nur anderen Nutzern Hilfestellung geben, die vielleicht ein vergleichbares Problem haben wie ich: Auf Raspberry Pi lief bei mir eine Anwendung, die mit Lizenzen auf einem CODESYS-Dongle lizenziert waren (Multicore-Support und Softmotion). Nach einem Hardware-Defekt habe ich meinen Rasperry Pi gegen eine robustere Lösung getauscht. Ich wollte auf der neuen Hardware die Runtime ausrollen und habe ständig den Fehler gezeigt bekommen, dass die Target- oder Zielsystem-ID nicht stimmt. Für den Raspberry Pi gibt es ja drei verschiedene Optionen der Runtime: 32bit Singlecore (armv6l) 32bit Multicore (armv7l) 64bit Multicore (aarch64) Entscheidend dafür, ob die 32 oder 64 Bit Runtime benötigt wird ist das auf der dem Raspberry Pi installierte Betriebssystem. In meinem Fall hatte ich durch die neue Hardware auch ein aktuellen Betriebsystem-Image aufgespielt, weshalb sich da der Umstieg von 32 auf 64Bit eingeschlichen hatte. In der Entwicklungsumgebung kann über Tools -> Control SL ausrollen das Fenster geöffnet werden, um die richtige Laufzeitumgebung auf dem Steuerungsrechner zu installieren. Bei kleinen Bildschirmen (bei mir ein 15" Laptop) kann der rechte Bereich "abgeschnitten" und das Dropdown-Menü als solches nicht auf den ersten Blick erkennbar sein. Mein Fehler war, dass ich den Scrollbalken nicht gesehen habe! (Bild im Anhang mit freundlicher Genehmigung von Herrn Heberle vom CoDeSys-Support) Nach dem auswählen der jeweils passenden Version kann die Runtime installiert und das Programm wieder geladen werden. Die Lizenzen sind bei mir wieder korrekt erkannt worden und alles läuft wie vorher (nur mit neuer Hardware). Vielen Dank an der Stelle noch mal an die schnelle Hilfe vom Support. Das hat wirklich top funktioniert.
Last updated: 2025-02-27
Post by harryc on Soft Container License issue with ARM64 Linux
CODESYS Forge
talk
(Post)
Hi, We are working to provide our customers with CODESYS operation on our hardware product ( https://elprotech.com/product/el-qe-e-quantum-edge-series/ ). I'm trying to enable a CODESYS license (Soft container) on our product running ARM64 linux. This problem am having looks similar to here: https://forge.codesys.com/forge/talk/Runtime/thread/6d29b6b4de/ and here: https://forge.codesys.com/forge/talk/Runtime/thread/a2d0c63375/; but I am not running docker, and I am not re-installing a license. This is first time install. I have CODESYS Control SL running on my device, as well as CodeMeter. I purchased a license, and installed it to the CODESYS Development system, (Tools >> License Repository) then tried to install to the device (Tools >> License Manager >> o Device >> o Soft container >> Remote [0001] >> OK. This gives me the "License Manager - Overview" dialog, and the message "Licensing info not available. There is no dongle attached to the device." Below shows the running applications, installed packages, and current content of /var/opt/codesys Also attached screenshots of the Development software as I go through the steps to install the license. # # ps | grep -e "code" -e "CodeMeter" 1391 daemon /usr/sbin/CodeMeterLin 1407 root /opt/codesys/bin/codesyscontrol.bin /etc/codesyscontrol/CODESYSControl.cfg 1442 root /opt/codesysedge/bin/codesysedge.bin /etc/codesysedge/Gateway.cfg 29229 root grep -e code -e CodeMeter # dpkg -l Desired=Unknown/Install/Remove/Purge/Hold | Status=Not/Inst/Conf-files/Unpacked/halF-conf/Half-inst/trig-aWait/Trig-pend |/ Err?=(none)/Reinst-required (Status,Err: uppercase=bad) ||/ Name Version Architecture Description +++-==============-=============-============-============================================================================================== ii codemeter-lite 8.20.6539.500 arm64 WIBU CodeMeter minimal runtime ii codesyscontrol 4.14.0.0 arm64 codesyscontrol based on SDK 3.5.20.40 , from Fri Nov 29 08:35:37 CET 2024 [265], Release build ii codesysedge 4.14.0.0 arm64 codesysedge based on SDK 3.5.20.40 , from Fri Nov 29 08:34:19 CET 2024 [265], Release build # ls -la /var/opt/codesys total 208 drwxr-xr-x 6 root root 4096 Nov 7 05:31 . drwxr-xr-x 1 root root 4096 Nov 6 08:33 .. -rw-r--r-- 1 root root 23515 Nov 7 07:26 .Audit.log -rw-r--r-- 1 root root 160 Nov 7 05:31 .GroupDatabase.csv -rw-r--r-- 1 root root 160 Nov 7 04:37 .GroupDatabase.csv_ -rw-r--r-- 1 root root 20736 Nov 29 2024 .SoftContainer_CmRuntime.wbb -rw-r--r-- 1 root root 1982 Nov 29 2024 .UFC_SoftContainer_CmRuntime.WibuCmLif -rw-r--r-- 1 root root 229 Nov 7 04:35 .UserDatabase.csv -rw-r--r-- 1 root root 229 Nov 7 04:35 .UserDatabase.csv_ -rw-r--r-- 1 root root 11807 Nov 7 05:30 .UserMgmtRightsDB.csv drwxr-xr-x 6 root root 4096 Nov 6 08:30 .pki drwxr-xr-x 3 root root 4096 Nov 6 08:30 OPCUAServer drwxr-xr-x 7 root root 4096 Nov 6 08:30 PlcLogic -rw-r--r-- 1 root root 13 Nov 6 08:30 SysFileMap.cfg -rw-r--r-- 1 root root 2640 Nov 29 2024 bacstac.ini drwxr-xr-x 4 root root 4096 Nov 6 08:30 cert -rw-r--r-- 1 root root 94105 Nov 7 07:25 codesyscontrol.log # # uname -a Linux Remote 6.1.22 #5 SMP PREEMPT Tue Nov 18 11:35:46 AEST 2025 aarch64 GNU/Linux #
Last updated: 2025-12-04
Post by sukrit on What licenses are required for runtime on raspberry pi cm4
CODESYS Forge
talk
(Post)
We have developed a project for 2 servo motors using raspberry pi computemodule 4 on ethercat master. we are using web visualization for display different screens. project is running well in demo. we want to implement it in production envoirment. being new still wondering which licences i need. Can We get this information in codesys devlopment software. code size is approx 5 mb, 1 instance of etharcat master and aproox 100 variables in visaualization.
Last updated: 2023-10-17
Post by fred on Rasperry Control Debian 12
CODESYS Forge
talk
(Post)
Hi, I have Proxmox running on a Rasperry 4 and have debian 12 ARM installed here. I wanted to install Codesys Control for Raspberry on it. According to the messages, the runtime environment and the gateway were installed successfully, but I can't find a device to downplay a program. The sudo service codesys start command fails. (see image) Does somebody has any idea? Thank you for your help! Greetings Fred
Last updated: 2023-11-22
Post by jeffg on License issue with visu tags
CODESYS Forge
talk
(Post)
I seem to be having a problem with the license on ver 3.5.19 patch 5 The runtime keeps going into demo mode but it wont tell me the reason I looked at the license software metrics and the visu doesn't appear to be working I attached screen shots of the metrics screen and the license dongle that is plugged in to the windows PC Anyone have any ideas on how to fix this
Last updated: 2024-06-28
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.