Post by nano on Persistent variable storage CODESYS Forge talk (Post)
use the persistence manager. with the persistence-manager, you're abΓΆe to define how, when and where you store your data
Last updated: 2024-06-16

Post by mos89p on Data source and safety PLC CODESYS Forge talk (Post)
it works only for me when i specify an IP adress in communication tab
Last updated: 2024-06-17

Post by timothyzalusky on Strange Behavior on Raspberry Pi CODESYS Forge talk (Post)
Hello, I am seeing some weird runtime behavior related to the EQ function on a rapsberry pi based system. I have attached a screenshot showing the strange latching I am seeing on the EQ function, and I have not seen this behavior before. I tried freshly restarting the runtime and it has this same behavior. Anyone seen this? I am on 3.5.20 with the latest runtime installed. Basically, as soon as it hits one of those EQ's in the program, it latches effectively locking the output on. Any input from the Codesys team would be appreciated as well as anyone that might know what I am seeing.
Last updated: 2024-06-18

Cant login to Rpi4 but can see it in codesys communications settings. CODESYS Forge talk (Thread)
Cant login to Rpi4 but can see it in codesys communications settings.
Last updated: 2024-06-22

Post by kthomas on Cant login to Rpi4 but can see it in codesys communications settings. CODESYS Forge talk (Post)
Thanks that did it!
Last updated: 2024-06-23

Cant login to Rpi4 but can see it in codesys communications settings. CODESYS Forge talk (Thread)
Cant login to Rpi4 but can see it in codesys communications settings.
Last updated: 2024-06-23

Post by rafael on Wbm/runtime and visualization login CODESYS Forge talk (Post)
Solved, there is a configuration inside the WBM where I can disable this login option (config>ports config)
Last updated: 2024-06-25

Post by eildp on Adding a Softmotion License to a Weintek HMI CODESYS Forge talk (Post)
I am here with the same question wondering if you found an answer. Anyone? Thanks!
Last updated: 2025-10-16

Post by ranadheer on Control Win SL licensing CODESYS Forge talk (Post)
Hi johnlee and jeffgamsby Is Control win SL is a SoftPLc Extension SL
Last updated: 2025-10-18

Post by eschwellinger on Two OneWireMaster on one Raspberry PI 5 CODESYS Forge talk (Post)
hm.. could you add the project or at least parts of it?
Last updated: 2025-10-20

Post by eschwellinger on Stepper motor control with (SM_Drive_RaspStepper_direct) CODESYS Forge talk (Post)
..the missing part is which Softmotion version is installed. Check it in the CODESYS Installer and update it to latest version.
Last updated: 6 days ago

Using a raspberry pi and NVLs to log variables outside of Codesys CODESYS Forge talk (Thread)
Using a raspberry pi and NVLs to log variables outside of Codesys
Last updated: 2 days ago

Post by eoahe on Problem Reading Registers via Modbus from non Codesys device CODESYS Forge talk (Post)
Hey Guys :) I have the following Problem using Modbus via Codesys: I'm trying to implement a Modbus Device into my codesys project. The device is a Router from Teltonika (RUT956) and it can communicate via Modbus. Currently I'm trying to implement it into my codesys prject as a slave and I'm using my windows computer as master. As it is not a codesys device (the codesys application is not uploaded to device as it has its own software) I'm having problems requesting and reading registers from the router. I've set up my windows computer as Master and implemented the router as slave. When I go online on my master device it sais that it has established a connection to the slave (router)(So I'm thinking this could work as there is a connection?). The goal is to read the GPS (latitude and longitude) data and on the homepage of teltonika you can find the register address and number of registers (adress 143 for latitude and 145 for longitude; both have a number of two registers). I've found tutorials how to read specific registers via their register address with other modbus programs (like modbus-cli), but as my entire project is established in codesys I was hoping to read these specific registers via codesys so that I can show the GPS data on my dashboard. I've tried establishing slave channels but that hasn't been working. I tried read input register channels of the length 4 but it's not possible to define specific register addresses to read via codesys so that didn't work (I jsut get a slaves device failure) and I've also tried establishing 516 (total number of registers the router sends I think?) read inputregister channels but that has the samle failure... So i guess the problem I'm having is establishing slave channels to read these specific registers. Does anyone know how to tackle this problem and has maybe had the same problem? Or maybe someone knows a workaround? I'm quite new to codesys so maybe I'm also lacking expertise...
Last updated: 2025-03-01

Post by rossanoparis on Upgrading CODESYS runtime from v4.7 to v4.9 using a bash script leads to lose the licences stored in the soft container CODESYS Forge talk (Post)
System information - Controller: KUNBUS RevPi CONNECT-S - OS: Linux buster 32bit 5.10.103-rt62-v7l #1 SMP PREEMPT_RT armv7l GNU/Linux - CODESYS v3.5 SP19 Patch 2 I'm facing a problem related to codesys licences using a procedure based on a bash script. Such bash script detect the presence of new .deb files and install them on system. My automation solution don't allow to be maintained by dedicated personal, thus even the CODESYS runtime SW must be installed using an "automatic" procedure instead of using the CODESYS tool. remark I've been using the following procedure since the runtime v4.5 without any issue. Before installing the new runtime packages, I need to copy the file CODESYSControl_User.cfg (here attached) because of new section which is necessary to add in order to allow some folders to be written by CODESYS runtime v4.9 Up to now, this has been unnecessary, this is the main difference between my previos bash file and the new one. remark If I skip this action, everythings goes fine, but my CODESYS application can't work as it needs to access some folders on controller's file system. Process - Before the procedure: the licenses are OK (see attached file lic-01.png) - After the procedure: the new CODESYS runtime version is correctly installed, but the software container with v1.19 and all licences disappear (see attached file lic-02.png) This is the synthetic content of bash script I'm using. # Stop runtime sudo service codesyscontrol stop sudo service codesysedge stop # Move the new CODESYSControl_User.cfg file # New configuraton with folders declared sudo mv -f CODESYSControl_User.cfg /etc # Install runtime package echo N | sudo apt-get install -y --allow-downgrades codesyscontrol_raspberry_4.9.0.0_armhf.deb # Install edge gateway package echo N | sudo apt-get install -y --allow-downgrades codesysedge_edgearmhf_4.9.0.0_armhf.deb # Reboot controller sudo reboot Thanks in advance
Last updated: 2023-09-19

Post by baldeep on Raspberry Pi 5 CODESYS Forge talk (Post)
Hi, though i am aware of the fact that Codesys doesnt not support Raspberry Pi 5 still i tried. Codesys Installation : worked Codesys Starting : worked but right after start it stopped. with Start Runtime it starts again but stops automatically after 5 seconds is Codesys planned for Raspi 5?! Regards... Singh
Last updated: 2023-12-06

Post by hermsen on Raspberry Pi 4.12.0.0 SL also stops after 15s CODESYS Forge talk (Post)
After installing this new 4.12.0.0 SL version on my RPi5 8GB and the latest bootloader, the runtime disappeared after 15secs. The bootloader my pi uses is from 2024-06-11. I was able to resolve this issue using this post: https://forge.codesys.com/forge/talk/Runtime/thread/be25c0ff66/ The workaround works for me.
Last updated: 2024-07-06

Post by ricola on codesys sp20 opcua not working CODESYS Forge talk (Post)
Hi, same pb for me ! did you find a solution ? (I'm working on 2 raspberry pi ) The same project compiled for 4.8.0.0 runtime with CodeSys 3.5SP20 is working fine on one target, and on the other one, my UAexpert receives the same "BadIdentityTokenInvalid" and none is working on 4.11.0.0 either ... anybody ?
Last updated: 2024-08-11

Post by nano on ERROR: CodeMAccess2: Used CmRuntime 2.61.2705.500 is too old CODESYS Forge talk (Post)
the codemeter deb files are part of the runtime-sl-installatonfiles. so u can download the whole raspberry pi package from store-page, unzip it with a progam like 7zip, there you'll find a folder called dependencys i thing. here should the deb files placed
Last updated: 2024-09-18

Post by gabor-n on PNIO Connect Parameter Error CODESYS Forge talk (Post)
It's a bit confusing, the two RPI is the same (board, OS, runtime, programing with Codesys V3.5 SP20 P2) but the one has a codesyscontrol.cfg file and the other has a codesyscontrol_user.cfg file. Shouldn't be the same? And because I over Codesys 3.5 SP 12 this would be the '_user.cfg' for both. Attached...
Last updated: 2024-10-11

Post by andrax on CodeSys Raspberry pi I2C driver not found CODESYS Forge talk (Post)
Sorry, wrong expression. You have a 64bit system, so do I. You can also use the 64bit runtime, but most bib and commands are 32bit and are not properly supported. I had read somewhere that there are problems with I2C. That's why I recommend switching to PI_SL and using the correct gpio.
Last updated: 2024-11-09

Post by mtnkyr on Runtime Problem connecting to Keyence IV-500MA Camera CODESYS Forge talk (Post)
I have to use Keyence IV-500MA Camera for a project. Actually I can use physical connection but I tried to connect using Ethernet protocol so I added its EDS file but I took a lot of errors. Could you help me to solve this problem?
Last updated: 2024-12-26

Post by mtnkyr on Runtime Problem connecting to Keyence IV-500MA Camera CODESYS Forge talk (Post)
I have to use Keyence IV-500MA Camera for a project. Actually I can use physical connection but I tried to connect using Ethernet protocol so I added its EDS file but I took a lot of errors. Could you help me to solve this problem?
Last updated: 2024-12-26

Post by damian177 on Serialports in EdgeBox-RPI-200 CODESYS Forge talk (Post)
Hi, Two years ago i used EdgeBox-RPI-200 with Codesys and serial ports works fine. Now I try run the same application but only new runtime but serial ports doesnt works: I have two serial: /dev/ttyACM0 - RS485 /dev/ttyACM1 - RS232 and below configuration in my sudo nano /etc/CODESYSControl_User.cfg: [SysCom] Linux.Devicefile=/dev/ttyACM But it doesnt work. what can i do ?
Last updated: 2025-05-17

Post by blitz on Latch alarm variables from the PLC runtime CODESYS Forge talk (Post)
Hi, I have a question. Does anyone know a way to change latch alarm variables from the PLC runtime? In the help there is a method described: https://content.helpme-codesys.com/en/libs/AlarmManager/Current/Interfaces/pou-IAlarm3/SetLatchVarValue.html but I don’t know how to use it correctly.
Last updated: 2025-09-23

Post by snhatton on OPC UA: How to change NodeId ?! CODESYS Forge talk (Post)
You can change the node id by adding the following to /etc/CODESYSControl.cfg: [CmpOPCUAProviderIecVarAccess] CustomNodeName=MyPLC123 Then restart the runtime and the new Node name will appear with the connection. I don't know if it's possible to remove the |var| from the name. I hope this helps!
Last updated: 2023-12-11