Search talk: Runtime objects > Device

 
<< < 1 .. 137 138 139 140 141 .. 149 > >> (Page 139 of 149)

Post by correo0269 on Problems with Raspberry Pi - IoDrvGPIO library CODESYS Forge talk (Post)
I am trying to create a new proyect using the Raspberry Pi 4.11.0.0 package with Codesys 3.5 SP20, I am able to communicate with the Raspberry and start the runtime application but when I create a new proyect I have these errors. When opening the library manager of the proyect the library of the IoDrvGPIO is used so I dont really know whats happening.
Last updated: 2024-04-05

Post by eschwellinger on Problem mit control runtime V3 und profinet CODESYS Forge talk (Post)
Hallo Tim, man hat halt einfach mit der Control Win - keine wirkliche harte Echzeit. Man müsste den Fehler genauer analysieren + ich denke er müsste den Slave wieder an den Busholen oder fällt ads ganze Netzwerk aus? Welche Versionen genau sind im Einsatz? Ist das halbwegs aktuell (PN 4.4.0.0?) Grüße Edwin
Last updated: 2024-04-11

Post by danwoodlock on Rpi zero w lost license after 4.11 update CODESYS Forge talk (Post)
Just adding some info: Today I found this post: https://forge.codesys.com/forge/talk/Runtime/thread/264bd530d4/ followed the steps suggested started with a fresh install of raspbian lite, installed 4.11, and then attempted to import my license update file. I get this when I do: Any help is appreciated.
Last updated: 2024-04-15

Post by koehler on Codesys 3.5.12 Module not Found CODESYS Forge talk (Post)
Hi there, I am getting troubles with a project. In the Hardware configuration I got some Lenze drives 9400. One of them got as status " Module not Found". Connection are good. ID Node of the Canopen network is also good. I don't find any reason for this status, nor any options to check.
Last updated: 2024-04-17

Post by eschwellinger on License problem gateway CODESYS Forge talk (Post)
most important information are missing: Which CODESYS Version? Which runtime version? Which plc type (manufacturere).. Not all plc manufacturer already support application based licenses. From your pictures I see you have activated 4 axis Motion (which is an applications based license type) does only work on plc's which do support this.
Last updated: 2024-04-25

Post by timvh on Codesys SVN CODESYS Forge talk (Post)
Minimum version is 3.5 SP19 Patch 3. See https://store.codesys.com/en/codesys-git.html But you could ask your PLC vendor if it is possible to program their PLC's which have Runtime version SP16 with development version 3.5 SP19 or higher (should normally be possible, but with Safety PLC's there could be some regulation limitations).
Last updated: 2024-05-01

Post by andrej on Channel timeout CmpChannelMgr CODESYS Forge talk (Post)
Hello, I use Codesys RTE 3.5.16.5. If I connect to the PLC I often get the following message: (see printscreen) 1. Channel timeout CMpChannelMgr. 2. Closing connection CmpChannelMgr. Can you tell me, what the meaning of this is? What does the number 1250030,1220020 resp. c400:0a0a:015a:0301 refer to? I could find any information in the online help. Thanks a lot.
Last updated: 2024-05-08

Post by yannickasselin on Linux ARM64 SL, GPIO Access CODESYS Forge talk (Post)
A bit of work but maybe possible to make your own driver using "CODESYS Control SL Extension Package". Look at the "ExternalIoDrv" example. It is installed in "C:\Program Files\CODESYS 3.5.20.0\CODESYS\CODESYS Control SL Extension Package" when you install the "CODESYS Control for Linux SL".
Last updated: 2024-05-08

Post by rajesh008 on i can't declear the address in GVL - codesys SP19 Patch5 CODESYS Forge talk (Post)
The “_AB AT %IW0:word; ” if i called the value then im getting this error. like below "the declartion of the variable with an address assignment cannot be used in a PRG or GVL with the attribute 'subsequent'" This is happening when the GVL is selected in Redundancy Configuration. if i un-select the address declaration is working fine
Last updated: 2024-05-13

Post by totorovic on IO-LINK Package - new license model CODESYS Forge talk (Post)
Hello, I'm using th IDE Combivis studio 6 (codesys based) and I get an error message when I use IO-link. "The license is missing or invalid. The API is running in demo mode." However the package Manager indicates that no licence is required. It used to work, it seems that the free package has become a paying one. Can Codeys confirm this? BR
Last updated: 2024-06-06

Post by kumareasu on Persistent variable storage CODESYS Forge talk (Post)
Is there any function function block which can store the persistent variable in HDD/SSD immediatley. My observation is that the persistent variable is getting stored when we shut down or restart the system (Windows+ CoDeSys RTE SL ). the persistent variables are not stored in HDD/SSD, if I power off the system without proper shutdown. Seeking your feedback.
Last updated: 2024-06-12

Post by andreag0 on How to access to variable value through symbolic string name CODESYS Forge talk (Post)
Hello, anyone know how to get valiable value using a symbolic string name? For example: - send string to runtime using TCP/IP contains "GVL.TestINT" and get back the value. I need function that will translate the string to symbolic variable. Thank you. Andrea
Last updated: 2024-06-13

Post by pharus on Setup problems with PiXtend CODESYS Forge talk (Post)
Hello all, I have an PiXtend V2L complete kit and installed everything like in the manual. Ive installed Codesys V3.5 S20 Codesys Control for Raspberry Pi PiXtend_V2_Professional_for_CODESYS.package But as soon as i Create a Project, i get a lot of error messages, and i cant find the PLC via Ethernet Thanks a lot
Last updated: 2024-06-19

Post by pharus on Setup problems with PiXtend CODESYS Forge talk (Post)
Hello all, I have an PiXtend V2L complete kit and installed everything like in the manual. Ive installed Codesys V3.5 S20 Codesys Control for Raspberry Pi PiXtend_V2_Professional_for_CODESYS.package But as soon as i Create a Project, i get a lot of error messages, and i cant find the PLC via Ethernet Thanks a lot
Last updated: 2024-06-19

Post by pharus on Setup problems with PiXtend CODESYS Forge talk (Post)
Hello all, I have an PiXtend V2L complete kit and installed everything like in the manual. Ive installed Codesys V3.5 S20 Codesys Control for Raspberry Pi PiXtend_V2_Professional_for_CODESYS.package But as soon as i Create a Project, i get a lot of error messages, and i cant find the PLC via Ethernet Thanks a lot
Last updated: 2024-06-19

Post by pharus on Setup problems with PiXtend CODESYS Forge talk (Post)
Hello all, I have an PiXtend V2L complete kit and installed everything like in the manual. Ive installed Codesys V3.5 S20 Codesys Control for Raspberry Pi PiXtend_V2_Professional_for_CODESYS.package But as soon as i Create a Project, i get a lot of error messages, and i cant find the PLC via Ethernet Thanks a lot
Last updated: 2024-06-19

Post by koppit on SysComRead Timeout Parameter CODESYS Forge talk (Post)
Im using SysCom ver. 3.5.17.0 and seem to have the same issue on a Raspberry Pi. It's not waiting for the requested number of bytes, no matter if "ulTimeout := SYS_INFINITE" or any other value. The only solution I have found is to stall the program to allow the serial port to recieve the data.
Last updated: 2024-06-26

Post by mucleus on What is the solution for "Application stopped on recovery switch request"? CODESYS Forge talk (Post)
Hi, everyone. I am using CODESYS RTE and Profinet I/O or EtherCAT I/O. Occasionally (once every 1-2 months) the attached image occurs and the program stops. I want to know why this phenomenon occurs and how to solve it. I attached log. Please help me. Thanks.
Last updated: 2024-07-05

Post by mos89p on CodeSysControlWinV3x64 CODESYS Forge talk (Post)
Hello Check: on the latest version the location change: If the PLC is started with the "CODESYS Control Win SysTray PLC Control", it runs in the Windows user account "LocalSystem" and therefore the effective working directory is "C:\Windows\system32\config\systemprofile\AppData\Roaming\CODESYS\" or "C:\Windows\SysWOW64\config\systemprofile\AppData\Roaming\CODESYS\". An administrator account is required to access these folders
Last updated: 2024-07-11

Post by ahuckphin on Issues with Modbus Slave with Raspberry Pi CODESYS Forge talk (Post)
codesyscontrol_user.cfg [SysCom] Linux.Devicefile.1 = /dev/ttyUSB0 portnum:=COM.SysCom.SYS_COMPORT1; **parameters are used in the python-script ** method: "rtu" port: "COM8" baudrate: 9600 stopbits: 1 bytesize: 8 parity: 'N' timeout: 1 register address for humidity: 0x000 register address for temperature: 0x001 unit ID: 1 **parameteized in the modbus-master-comport ** see attached files
Last updated: 2024-07-11

Post by nltheves on Raspberry PI4 Serial Port CODESYS Forge talk (Post)
Hi Ricardo. I was having the same problem with Codesys and a Raspberry Pi 2W while using the GPIO uart. Your post helped me a lot. Thanks! But could not understand why MODBUS parity bit makes Codesys MODBUS COM driver stopping to work after first request transmission. Did you see this @eschwellinger ? Regards, Nelson
Last updated: 2024-07-18

Post by dantheman on Connecting to SoftPLC Only Works By Turning Off Modbus Ethernet Port CODESYS Forge talk (Post)
I've also noticed that when I turn off "enp1s0", suddenly the source IP for the ModbusTCP changes to that of "enp2s0", which is what makes sense to me. When I turn it back on, the source IP remains that of "enp2s0".
Last updated: 2024-08-01

Post by fajean on Raspberry Pi 5 CODESYS Forge talk (Post)
We are having issues right now, and I just stumbled on that post. It seems to me you are saying your Linux ARM control is RPi 5-compatible, but the one you sell specifically for RPi is not. The fix you are proposing requires customers to re-purchase a CODESYS licence. Is there a time frame for that to be fixed?
Last updated: 2024-08-07

Post by taqamert on Codesys 3.5 Library Download Failed CODESYS Forge talk (Post)
Hello, I need a few libraries in CoDeSys 3.5. I want to download them using the "Download Missing Library" option from the Library Manager menu. However, I keep getting a "Download Failed" error. Despite trying at different times, I haven't been able to download them. What should I do?
Last updated: 2024-08-21

Post by docker on Webvisu client connection monitoring CODESYS Forge talk (Post)
Hi, i am interested in this thread and have tried a couple of the above examples in to determine remote webvisu access. I am having trouble getting the lastusage variable to refresh during runtime? It seems to only log the last usage at initialisation and that is it? how do i gain ongoing access to the time variable as the code is running? Thankyou.
Last updated: 2024-08-26

<< < 1 .. 137 138 139 140 141 .. 149 > >> (Page 139 of 149)