PI Input value
CODESYS Forge
talk
(Thread)
PI Input value
Last updated: 2024-01-12
Project Login Problem
CODESYS Forge
talk
(Thread)
Project Login Problem
Last updated: 2024-02-01
Holding brake release
CODESYS Forge
talk
(Thread)
Holding brake release
Last updated: 2024-04-08
Post by huzeyfe on SMC_INT_QPROF_DIVERGES
CODESYS Forge
talk
(Post)
Last updated: 2024-04-15
CAA Library Function
CODESYS Forge
talk
(Thread)
CAA Library Function
Last updated: 2024-04-16
Upload program
CODESYS Forge
talk
(Thread)
Upload program
Last updated: 2024-05-01
SFC Action problems
CODESYS Forge
talk
(Thread)
SFC Action problems
Last updated: 2024-05-27
SM_Drive_Virtual
CODESYS Forge
talk
(Thread)
SM_Drive_Virtual
Last updated: 2025-10-21
Anfänger hat Problem
CODESYS Forge
talk
(Thread)
Anfänger hat Problem
Last updated: 2025-12-03
Anfänger hat Problem
CODESYS Forge
talk
(Thread)
Anfänger hat Problem
Last updated: 2025-12-03
AI + Programming
CODESYS Forge
talk
(Thread)
AI + Programming
Last updated: 2026-03-23
Visualization 🇬🇧
CODESYS Forge
talk
(Discussion)
Realizing operator screens with CODESYS HMI, Targetvisu, Webvisu
Last updated: 3 days ago
Post by trusty-squire on CNC - How to manipulate SMC_GeoInfo objects
CODESYS Forge
talk
(Post)
I have an application using CNC GCode interpolation, but I need to modify the GCode provided to the PLC based on certain parameters. I am currently attempting to modify the SMC_GeoInfo objects in the SMC_OutQueue using the code below. Note that all the other code is pretty standard and works fine, but when I add the below it errors. PROGRAM TEST VAR fbReadCncFile : SMC_ReadNCFile2; fbCncInterpreter : SMC_NCInterpreter; arrCncInterpreter : ARRAY[1..99] OF SMC_GeoInfo; pGeoInfo: POINTER TO SMC_GeoInfo; giGeoInfo: SMC_GeoInfo; // ... END_VAR // ... Some code here in order to read CNC file using SMC_ReadNCFile2 and provide to SMC_NCInterpreter pGeoInfo := SMC_GetObj(poq:=ADR(fbCncInterpreter.poqDataOut), n:=1); IF pGeoInfo <> 0 THEN giGeoInfo := pGeoInfo^; // Do some manipulation here, then update the queue at the same position MC_SetObj(poq:=ADR(fbCncInterpreter.poqDataOut) , n:=0 , pgi:=ADR(giGeoInfo) ); END_IF It throws an error when I get to the line giGeoInfo := pGeoInfo^; Error: EXCEPTION [AccessViolation] occured: App=[Sim.Device.Application], Task=[PathTask] How do I use SMC_GetObj and access the data? It creates a pointer with the value as shown in the photo, but all the dereferenced values say dereference of invalid pointer.
Last updated: 2024-07-26
Post by vipul on Multicast udp
CODESYS Forge
talk
(Post)
Hi, Good afternoon can anybody help me with UDP Multicast code. I am not able to send or recieve data when code is dumped on linux device. Below is my code. Declaration: PROGRAM udp_multicast VAR oneTimeFlag :UINT :=0; state: INT:=0; driver: UDP.UDPDriver; //port : UDP.Port;//moved to GVL src_ipAddr_ud: UDINT; src_ipAddr_st:STRING := '192.168.127.155';//'192.168.1.155';//ipms ip address dst_ipAddr_ud:UDINT; group_ipAddr_st:STRING := '239.1.5.10'; //group_ipAddr_ud:UDINT; result: SysTypes.RTS_IEC_RESULT; //result of recieve function. bind: UDINT; //result of binding. resultCreate:SysTypes.RTS_IEC_RESULT;//result of port creation. timer:BLINK; temFlag :INT:= 0; post:INT :=0; checksumFunc:checksumXor; localStringBuf:STRING[500]; chksum:BYTE; dataBuffer:POINTER TO BYTE; checksumString:ARRAY[0..5] OF BYTE; recvSize:__XINT; errorCode:UDINT; joinGroupErrorCode:UDINT; END_VAR ************8 Implementation: IF oneTimeFlag <> 1 THEN oneTimeFlag:=1; resultCreate := driver.CreatePort(ADR(GVL.port)); src_ipAddr_ud := UDP.IPSTRING_TO_UDINT(sIPAddress:= src_ipAddr_st); GVL.group_ipAddr_ud := UDP.IPSTRING_TO_UDINT(sIpAddress:= group_ipAddr_st); GVL.port.IPAddress := src_ipAddr_ud; GVl.port.ReceivePort:= GVL.src_port;//port on which messages are expected. GVl.port.SendPort := GVL.dest_port; GVl.port.OperatingSystem := 0; //0- any system GVL.port.Socket :=3; //3- socket type is multicast bind := GVL.port.Bind(udiIPAddress:=src_ipAddr_ud,); GVl.port.JoinGroup(udiGroupAddress:= GVL.group_ipAddr_ud,udiInterfaceAddress:= src_ipAddr_ud,eLogCode=>joinGroupErrorCode); END_IF timer(ENABLE:=TRUE,TIMELOW:=T#100MS,TIMEHIGH:=T#100MS); IF timer.OUT = TRUE THEN GVL.port.Send(udiIPTo:=GVL.group_ipAddr_ud,GVL.dest_port,pbyData:=ADR(GVL.writeData),diDataSize:=SIZEOF(GVL.writeData)); ELSE SysMemSet(ADR(GVL.readData[0]),0,SIZEOF(GVL.readData)); result := GVl.port.Receive(ADR(GVL.readData),diDataSize:=SIZEOF(GVL.readData),udiIPFrom=>dst_ipAddr_ud,diRecvSize=>recvSize,eLogCode=>errorCode); SysMemMove(ADR(GVL.readDataBuf[0]),ADR(GVL.readData[0]),SIZEOF(GVL.readData)); END_IF post:=LEN(GVL.readDataBuf);
Last updated: 2024-01-14
Post by kblundy on Change the Opening Position of the Dialog using VU.FbOpenDialog
CODESYS Forge
talk
(Post)
I hope the community can help me with this. I need to use the Visu Utils FbOpenDialog to control the opening and closing of a dialog. I have the Opening and Closing working, but I can’t get the dialogue's position to be controlled. The code looks like this: PROGRAM OPEN_DIALOG VAR xOpenLatchSettingDialog : BOOL; TopLeftDialog : VisuStructPoint ; fbOpenLatchSettingsDialog : VU.FbOpenDialog ; END_VAR IF xOpenLatchSettingDialog THEN xOpenLatchSettingDialog:= FALSE ; TopLeftDialog.iX := 100; TopLeftDialog.iY := 23; fbOpenLatchSettingsDialog(sDialogName := 'visu_AlarmLatchSettings', xExecute := xOpenLatchSettingDialog , xModal := TRUE, itfClientFilter := VU.Globals.OnlyTargetVisu, pTopLeftPosition := ADR(TopLeftDialog)); CloseVisuDialog(sDialogName:= 'visu_AlarmLatchSettings'); ELSE xOpenLatchSettingDialog:= TRUE ; IF fbOpenLatchSettingsDialog.xError THEN xOpenLatchSettingDialog := FALSE; END_IF END_IF I can't seem to work out a way to make the values in TopLeftDialog.iX and TopleftDialog.iY be passed correctly in the call and for it to change the position of the dialogue box. The code is compiled, but the position has not been changed. Any guidance or suggestions for revising this code would be incredibly valuable. Your insights could be the key to solving this issue.
Last updated: 2024-05-05
Post by trusty-squire on SysProcessCreate2 on Linux runtime
CODESYS Forge
talk
(Post)
Hi, I'm trying to launch a continuously running python script from Codesys and monitor the script status inside the Codesys runtime (running on a Linux enviroment). For now I'm testing with the below to emulate a continuously running Python script: #test.py i = 0 while True: i += 1 I'm able to successfully run the script using SysProcessExecuteCommand2 (I can see the Python process running in the task manager). However, this "freezes" the Codesys execution of the task - it sits on that command and will not continue until the Python script ends. I've proven this works by using the task monitor to kill the process, then Codesys continues on happily through the task. What I want to do is use SysProcessCreate2 to set up the Python script as a background task and monitor the process using SysProcessGetState. This always results in the error "ERR_OPERATION_DENIED". I know that I'm able to execute commands (as above), so my config should be correct. Is SysProcessCreate2 functional on a Linux environment? Is there something in the config file I'm missing? Here's my "working" code that uses SysProcessExecuteCommand2: VAR bTest : BOOL; sCommand : STRING := '/usr/bin/python3 /var/opt/codesys/PlcLogic/Application/test.py'; refCommand : REFERENCE TO STRING REF= sCommand; sOutput : STRING; refOutput : REFERENCE TO STRING REF= sOutput; result : RTS_IEC_RESULT; END_VAR IF bTest THEN SysProcessExecuteCommand2( pszCommand:= refCommand, pszStdOut:= refOutput, udiStdOutLen:= SIZEOF(sOutput), pResult:= ADR(result) ); bTest:= FALSE; END_IF And here's the code that always results in the ERR_OPERATION_DENIED error: VAR bTest : BOOL; sApp : STRING := '/usr/bin/python3'; sCommand : STRING := '/var/opt/codesys/PlcLogic/Application/test.py'; refApp : REFERENCE TO STRING REF= sApp; refCommand : REFERENCE TO STRING REF= sCommand; hResult : SysProcess.RTS_IEC_RESULT; hHandle : SysProcess.RTS_IEC_HANDLE; END_VAR IF bTest THEN hHandle := SysProcessCreate2( pszApplication:= refApp, pszCommandLine:= refCommand, ulFlags:=SYSPROCESS_CREATEFLAG_HIDDEN, pResult:= ADR(hResult) ); bTest:= FALSE; END_IF Here's the relevant section from the config file at /etc/codesyscontrol/CODESYSControl.cfg: [SysProcess] Command=AllowAll Appreciate any support or ideas. Thanks!
Last updated: 2025-03-16
Post by cer-wa on Not able to connect multiple profinet encoder in codesys Linux ARM64
CODESYS Forge
talk
(Post)
Hello, currently im working with a RevPi connect 5 on a codesys project. Up until now I was having a blast because things were going really smooth but for like almost a day im kind of stuck on the integration of multiple profinet sensors into my project. This is kind of a bummer because that should be an easy thing to do. What I tried so far was to create and additional ethernet adapter where I then tried to connect my devices. in the beginning I tried to connect the devices directly which was not working because I could assign the IP-adress only to the ethernet adapter and not to the devices but the device was found in the device repository (this gets important in the second part) So what I tried next was to setup a PN-Controller and connect my devices subsequently to the Controller. Sadly now the devices wont show up in the device repository anymore. To me its not clear why this is happening. And the worst thing is: I went ahead and setup a device completely like I would want to have it in the project and when I then click on scan devices I can even find the device. But it can not be added to project for whatever reason eventhough im 100% certain that the gsdml file is the correct one. Can anyone help me with this. Like I said this seems like an easy thing to do and its taking me way longer than expected already. The only thing that came to my mind why this might not work is because I have codesys license which only allows one profinet instance. Could that be the case? The error message seems then pretty unfit but ok. I will be grateful for every advice. Thanks in advance! Best regards!
Last updated: 2025-09-25
Aufrufen von Scripten (Python) aus CODESYS. Beschreiben von globalen Variablen in Codesys durch Script
CODESYS Forge
talk
(Thread)
Aufrufen von Scripten (Python) aus CODESYS. Beschreiben von globalen Variablen in Codesys durch Script
Last updated: 2017-09-10
Migration von "CODESYS Control for PFC200 SL" zu WAGO FW26 "CODESYS V3.5.19.2"
CODESYS Forge
talk
(Thread)
Migration von "CODESYS Control for PFC200 SL" zu WAGO FW26 "CODESYS V3.5.19.2"
Last updated: 2023-11-23
Post by jeffersonhui on SFC Reset Codesys 2.3?
CODESYS Forge
talk
(Post)
Hi, Is there a way to reset an SFC in Codesys 2.3, similar to using the "SFCReset" flag in Codesys 3.5? Thanks
Last updated: 2024-11-20
Installing boot application to CodeSYS HMI SL without login through CodeSYS
CODESYS Forge
talk
(Thread)
Installing boot application to CodeSYS HMI SL without login through CodeSYS
Last updated: 2021-01-05
Codesys V3 programming system and other Codesys system on same PC
CODESYS Forge
talk
(Thread)
Codesys V3 programming system and other Codesys system on same PC
Last updated: 2019-07-04
CODESYS Raspberry Pi – How to use CODESYS tags with external script?
CODESYS Forge
talk
(Thread)
CODESYS Raspberry Pi – How to use CODESYS tags with external script?
Last updated: 2017-10-04
Difference between CODESYS Control RTE x64 and CODESYS Control RTE V3 x64
CODESYS Forge
talk
(Thread)
Difference between CODESYS Control RTE x64 and CODESYS Control RTE V3 x64
Last updated: 2021-05-10
Migrate from Codesys WIN 32 bit to Codesys RTE 64 bit
CODESYS Forge
talk
(Thread)
Migrate from Codesys WIN 32 bit to Codesys RTE 64 bit
Last updated: 2015-12-15
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.