Post by s1ack on Wago PFC200 Ethernet / IoDrvEthernet Issue?
CODESYS Forge
talk
(Post)
CODESYS Control for PFC200 4.13.00 CODESYS IIoT Libraries SL 1.11.0.0 Application Based License: CODESYS Control Standard M I have (2) projects with similar code base and both using Wago PFC200. On the second project I am seeing 2 things that I have not been able to resolve: 1) Errors in the log under the Ethernet Item: IoDrvEthernet: [PCI\E1Q51CE62] Could not be found on target! Please check the Ethernet settings. 2) Exception for CPU Load. "Processorload watchdog: plcload=100, maxplcload=95" I have slowed down cyclic tasks on this project, even though on the first project there is actually more code - and it does not exhibit this behavior. In looking at the CPU loading via Linux 'TOP' command there appears to be 20% idle. So plenty of headroom (my opinion). In an effort to troubleshoot I have duplicated the target hardware on my bench. It ran overnight without a CPU load exception. On the test system, I have tried (3) version of the ethernet device. 3.5.16.0 3.5.17.0 and 4.2.0.0 Presently the log does not show the error, but status says the module reports an error. I really do not know if this issue is related to the CPU load exception. The issue does not appear to effect ethernet communications (ModbusTCP or SNMP or Webvisu or PuTTy into Linux Shell). On my test bench I have ModbusTCP slave simulators for all ModbusTCP slaves, but only (1) of the (5) SNMP devices present.
Last updated: 2025-01-21
Post by c3po on Visualisierung wechseln über SPS Variable Codesys 3.5
CODESYS Forge
talk
(Post)
Sì senor: https://www.helpme-codesys.com/help-sp17-lower.html Abgeschaltet! Peinlich! Ah ich liebe es in Foren nachfragen zu müssen, weil der Support NULL funktioniert. Dieser freundliche Ton immer ô.0 Da bitte, meine Suche: https://www.helpme-codesys.com/search.html?L=1&id=888&tx_solr%5Bq%5D=current+visu 1. Link angeklick: https://content.helpme-codesys.com/en/libs/VisuElemBase/Current/Private-Implementation/pou-Visu_PRG/DoCurrentVisuHandling.html (2. und 3. Link haben mir auch nicht groß weiter geholfen, also habe ich dieses Forum kontaktiert) thx for your help!
Last updated: 2024-08-27
Post by dkugler on Visualisierung: Tastatur vergrößern?
CODESYS Forge
talk
(Post)
mir ist kein Scallierungsparameter bekannt bisher. Als Workaround fällt mir folgendes ein: für keypad und numpad jeweils eine zusätzliche Visualisierungen erstellen, welche lediglich einen Frame enthält, der wiederum das originale numpad und keypad aufruft. Über die Eigenschaft relative Bewegung X & Y könnte dann der Frame sogar zur Laufzeit über eine Variable in der Größe angepasst werden. Die beiden ersellten Visualisierungen muss man dann noch im Visumanager unter Dialogeinstellugen als zu verwendende Numpad und Keypad entsprechend zuweisen. Nachteil: Visu-Scallierungen sind oft Spritfresser, sprich gönnen sich ordentlich Rechenleistung. Viel Erfolg!
Last updated: 2025-02-24
Post by eschwellinger on Ethercat scan for devices not picking up EL7041 as a softmotion axis
CODESYS Forge
talk
(Post)
Add existing version (with SM drive) - without scan - disable under expert settings in the slave the revision check.
Last updated: 2023-09-03
Post by aguado on Setting up the "Visual Studio Code" debugging environment (using .NET debugging) for use with the ScriptEngine API in Python.
CODESYS Forge
talk
(Post)
Hi, did you ever get this to run? Best Till
Last updated: 2023-09-12
Post by transmin01 on PCAN serial "No CAN driver found"
CODESYS Forge
talk
(Post)
Second question is, how do I determine the correct network ID for my Canbus config in Codesys? I have 2 CANbus ports on the target PC. Regards Trevor
Last updated: 2023-09-14
Post by timvh on Troubles with using CAN API
CODESYS Forge
talk
(Post)
In the example project, you can see that a CAN.CANAreaReceiver is used which has an VAR_IN_OUT reference to a RECEIVER_AREA structure. This structure has a dwIdStart and dwIdEnd to filter a range of ID's and process them through the referenced msgProcessor.
Last updated: 2023-09-19
Post by sedoerr on Check For Open Dialogs On Client
CODESYS Forge
talk
(Post)
You need to create a function around this function to check the dialogs you use in your program. That's the way i have done it.
Last updated: 2023-09-26
Post by rschwager on description about the build compiler definition
CODESYS Forge
talk
(Post)
Hi CODESYS moderators and user! Is there any description about the compiler definition in property of application? e.g.: CANOPEN_NO_HEARTBEATPRODUCING Is there more definition? Best regards Robert
Last updated: 2023-09-26
Post by sivakov on Change the default ssh port
CODESYS Forge
talk
(Post)
Of course there is! =) just edit file/etc/ssh/sshd_config and restart ssh service. but you'll lose the possibility of runtime management through "update Linux", so there enother question - how to change default port in codesys it-self?
Last updated: 2023-10-11
Post by totorovic on Codesys Softmotion Win V3 x64
CODESYS Forge
talk
(Post)
You have to update the device in your IDE to 3.5.14 or you can contact your Codesys runtime supplier to know how to set the connected system to 3.5.19
Last updated: 2023-11-09
Post by hwopereis on How to use Application Trigger in Modbus TCP Server
CODESYS Forge
talk
(Post)
I'm now circumventing the problem by creating a separate TCP client for all Write actions. Upon registering a changed variable, I enable this client, until the change is processed.
Last updated: 2024-07-01
Post by shabroz-gill on Data Sources Manager causing exception due to float or double type in OPC server
CODESYS Forge
talk
(Post)
Was this ever resolved? I see the same issue with the version 3.5.19.5
Last updated: 2024-07-01
Post by mucleus on What is the solution for "Application stopped on recovery switch request"?
CODESYS Forge
talk
(Post)
Component ID 10 is my own log message by LogAdd Function. I want to know in what cases the application stops.
Last updated: 2024-07-09
Post by ljg007 on Variable assignments
CODESYS Forge
talk
(Post)
That is an output of the Function Block ModbusMasterRTU example: xIsConnected=> xIsConnected In this line the VAR ModbusMasterRTU.xIsConnected is written to VAR xIsConnected xError=> is writing to nothing here.
Last updated: 2024-07-22
Post by lukaszklupa on Codesys Virtual Control - startup problem
CODESYS Forge
talk
(Post)
Hello I have a problem with starting Virtual Control, details in the attached screenshots. My system is Ubuntu 24.04 LTS. What's the problem? Is anyone able to help?
Last updated: 2024-08-13
Post by eschwellinger on Codesys Virtual Control - startup problem
CODESYS Forge
talk
(Post)
I think you have already up and running an Edge on the host ( not in the container) please uninstall that edge, then it should work.
Last updated: 2024-08-13
Post by lyngaansns on Python script: Launch Codesys, Execute Script, Exit Codesys
CODESYS Forge
talk
(Post)
Hello I am looking for the same thing, so i don't have an answer, but in your case you could possibly use the --noUI flag when running codesys, if you don't care about showing what's happening.
Last updated: 2024-09-06
Post by dkugler on CmpCrypto CryptoGenerateHash Not Outputting
CODESYS Forge
talk
(Post)
looks like your _hHash handle is "empty" (00000) at the breakpoint! I don't know if CryptoGetAlgorithmById(...) call in the VAR section is possible? would be good to know.
Last updated: 2024-09-06
Post by thn-power on Codesys Communication Manger - Required information model version exists in the model repository but is not found
CODESYS Forge
talk
(Post)
Hi Did you found a solution for this? I also have the same problem
Last updated: 2024-09-18
Post by ph0010421 on How to manage variable types larger than 64 bits - Ethernet/IP
CODESYS Forge
talk
(Post)
So it's currently mapped to an array of BYTES? Can you create a UNION? TYPE sBytesString : UNION AsBytes: ARRAY[0..127] OF BYTE; AsString: STRING(128); END_UNION END_TYPE Map it to the bytes, read it in the STRING!
Last updated: 2024-09-23
Post by egau on No option to create "Parameter List" in library
CODESYS Forge
talk
(Post)
Hi, pretty late to the party, but did the "defining constants per FB instance" actually became a thing? @ingo
Last updated: 2024-10-07
Post by paulpotat on Can't open license manager with raspberry CM4
CODESYS Forge
talk
(Post)
Update : The solution I mentionned in a previous post does not always work. Some Raspberry Pi CM4 still won't create the license container. I will open a support ticket.
Last updated: 2024-10-18
Post by sigurdrb on Codesys and error messages, warnings exceptions etc.
CODESYS Forge
talk
(Post)
I can add that the values I want to read are typical these values highlighted in red on the picture attached.
Last updated: 2024-11-06
Post by struccc on Checking or changing objects dimensions using code.
CODESYS Forge
talk
(Post)
That time it was not answered. But yes, it is possible. Search for "Relative movement" properties of the rectangle element. Might need to enable advanced features in the property browser. https://content.helpme-codesys.com/en/CODESYS%20Visualization/_visu_elem_rectangle.html
Last updated: 2024-11-19