Post by ewi04 on How to upload application file to remote controller (offline) ?
CODESYS Forge
talk
(Post)
Thank you very much for your time and replay! Sounds like a good idea. Unfortunately, I have no other option to run the code from the running plc. So, I can’t stop any services. If anyone has the same problem, I've gotten a little closer to understanding it: Sometimes the copied files are empty after the restart. The update code checks if there are any empty files. Before I turn off the device, everything is okay. But after starting, some files are suddenly empty and that cause the problems. I don't know why this happens.
Last updated: 2024-02-16
Post by bschraud on Zielsystem stimmt nicht mit dem verbundenen Gerät überein
CODESYS Forge
talk
(Post)
Hallo, nach einer Umrüstung des RPi auf SSD habe ich den RPi neu aufgesetzt. Nach dem Installieren der Runtime (4.11.0.0 raspberry, all) auf den RPi kann ich das Gerät nicht mehr verbinden. Die Fehlermeldung lautet "Das gewählte Zielsystem 'Codesys Control for Raspberry Pi MC SL' stimmt nicht mit dem verbundenen Gerät 'Codesys Control for Raspberry Pi 64SL' überein. ID-Diskrepanz: Ausgewählt=000 0011, Online=0000 0012" Bei der Konfiguration des Laufzeitsystems kann man nur Multicore 64-bit (Aarch64) auswählen. Beim Aktualisieren des Gerätes im Gerätebaum habe ich Raspberry Pi MC SL in der Version 4.11.0.0 ausgewählt. Diese Version habe ich auch ausgewählt, weil nur diese Version für den produktiven Einsatz zugelassen ist. Die codesys Version ist frisch installiert, also 3.5.19.60 Vielen Dank für Ihre Hilfe
Last updated: 2024-03-08
Post by wmoon on Licensing info not available.
CODESYS Forge
talk
(Post)
Hello, I bought some licenses from CODESYS store. I am trying to install licenses into my device(CODESYS Control for Linux ARM64 SL). But I have a trouble with it. I did it in the following order. Tool -> License Manager Selected Device and Next... Selected Soft container and Next... Select the device and Ok.. And then I always show a message "Licensing info not available. There is no dongle attached to the device." And I tried to click "Install Licenses" button. I saw the message "The value cannot be NULL. Parameter name : continerToLicenses" Could you let me know what I've missed or what I've got wrong?
Last updated: 2024-03-19
Post by mani-i4point0 on Issue with WebVisu on Raspberry PI
CODESYS Forge
talk
(Post)
Hi, I am running Codesys Runtime by purchasing 'Codesys control for raspberry pi MC SL', I am trying to use the Variables from my GVL's. Few of the variables used as a Pushbutton form the Visualization. These 'BOOL' Variable getting unlatched automatically even though there is no write function in the Overall project. All of them are 'Read' functions, at the same time few other BOOL variable behaviors are seems to be fine. I have tried, clean all and download, serval time restarted the hardware. Happy to share any any information. Your input to resolve this issue would be highly appriciated. Version Details: codesyscontrol 4.8.0.0, armhf codesyscontrol based on SDK 3.5.19.0
Last updated: 2024-03-20
Post by albzen on EtherCat Slaves diagnosis
CODESYS Forge
talk
(Post)
Hello everybody, I'm working on a RunTime Plc (Codesys 3.5.16/18.20) connected to an EtherCat bus with many devices. The bus has some communication fault but I don't know how understand which is the device or the cable that has the trouble. To understand the cause of the problem I would like to read the WKC (Working counter) of the devices (0x0300...0x030C), how is explained in EtherCat documents, but it seems that the read of the counter is disabled. Attached there is an extract of the Ethercat document. Can anyone give me some advice about how and with function can I read it. Thank you in advance!
Last updated: 2024-03-29
Post by albzen on EtherCat Slaves diagnosis
CODESYS Forge
talk
(Post)
Hello everybody, I'm working on a RunTime Plc (Codesys 3.5.16/18.20) connected to an EtherCat bus with many devices. The bus has some communication fault but I don't know how understand which is the device or the cable that has the trouble. To understand the cause of the problem I would like to read the WKC (Working counter) of the devices (0x0300...0x030C), how is explained in EtherCat documents, but it seems that the read of the counter is disabled. Attached there is an extract of the Ethercat document. Can anyone give me some advice about how and with function can I read it. Thank you in advance!
Last updated: 2024-03-29
Post by bschraud on Unerwünschte Username- und Passwortabfrage im Browserfenster
CODESYS Forge
talk
(Post)
Hallo, nach der Portierung meiner Applikation von Codesys Version 3.5.18 auf 3.5.20 habe ich u.a. folgende Baustelle: Wenn in der Datei /etc/CODESYSControl_User.cfg die Einträge [SysProcess] Command=AllowAll und [CmpWebServerHandlerV3] AllowFileTransferServices=1 ergänzt werden, startet die Webvisu mit einer Login Abfrage. Die Webvisu soll aber (wie bisher auch) ohne Benutzeraktion starten. Den Browser für die Webvisu rufe ich mit dem Eintrag @firefox --kiosk --private-window localhost:8080/webvisu.htm in der autostart Datei auf. Wie kann man die Login-Abfrage wieder loswerden? Die Runtime läuft auf einem RPi mit Kernel Version 6.1.21 (aarch64) Vielen Dank für die Hilfe
Last updated: 2024-04-02
Post by dhumphries on How to determine code size
CODESYS Forge
talk
(Post)
I'm trying to determine which Codesys Control license I need, the Control Standard S has all the features I think I'll need, but the code size is limited to 3mb, I created a simple program with only 1 line of ladder logic and a simple visualization with a button and an indicator. When I generate code I get some messages, one indicates that the total allocated memory size for code and data is 2.1mb. Is this metric the correct size of the code? I question the size because it exceeds the allowable code size for the Basic S and Basic M licenses and consumes 2/3 of the available memory for the Basic L or Standard S license. What tool can I use to estimate the size of code as it relates to the runtime license limit?
Last updated: 2024-04-05
Post by sachem on Problem retain values Weidmuller UC20-WL2000
CODESYS Forge
talk
(Post)
Good afternoon. I am working with a weidmuller uc20-wl2000 controller, using a codesys license. We made a ladder code to control a process, and it works well, but we want some variables to remain stored even when the controller is turned off. We tried to use retain variables, but at the time of loading the program, when we went offline from the controller, the program was deleted, it did not remain in the controller, and in the same way if we turned off the controller. In addition to this, when we tried to program it again, the program would not stay loaded and began to present errors with the opc-ua communication. What could be causing this problem? How can we maintain the values of the variables without damaging the program or affecting the controller? thank you
Last updated: 2024-04-10
Post by valenting on Can't use new licensing with Raspberry Pi
CODESYS Forge
talk
(Post)
Hi, I'm using Codesys control for Raspberry Pi in the latest version (4.11.0.0) When I try to install a license with the new application-based licensing, I have an error "returncode 403046401" (using codesys SP18) I updated to codesys SP20, and now I get the following error: "The selected conainer [0]: SN=..., Version=1.18, Chip=0, Rev=0 does not fit to your ticket. Please select a suitable one." The license I'm trying to install is a Codesys Control Basic L license, with a Codesys Visualization L option, according to the needs of my application. What can I do to activate my license ?
Last updated: 2024-04-22
Post by fontrap on cmDongle Raspberry Pi issue
CODESYS Forge
talk
(Post)
Good morning @eschwellinger, After some research I found out that the problem is the preinstalled CodeMeter on Raspberry Pi. As I mentioned the CodeMeter was installed on the Raspberry because I use a license from other vendor that needs the CodeMeter to be installed. The problem is that when I uninstall the CodeMeter from Raspberry I am able to detect the dongle from CODESYS and everything works as it should be but now the other product can not detect its own license. When I reinstall the CodeMeter I am back to the initial problem. Is there a way to overcome this conflict through CODESYS?
Last updated: 2024-04-24
Post by wbj0t on connect IDE to plc that uses modem ppp
CODESYS Forge
talk
(Post)
Hello everyone! I have an PLC device that uses modem ppp connection to the internet with white IP. Device PPP connection with modem operator established, so I can connect to this device via SSH also within Codesys IDE (check version, info, etc...) BUT, I cant establish connection to this device in the device gateway options for application upload and debugging. How can I do this? Im trying set my device remote IP and port 11740, but, as I understand, it is wrong decision, because the next logic in this connection: local W10 service (Codesys Gateway) listen on 1217, then (some how) this service scanning local networks for seeking any local IP which listening on port 11740, and then connects and writes there. OR IM WRONG?:) W10 tool 'Test-NetConnection' with parameters 'ip -Port 11740' succeeded with True. Need some help, please :)
Last updated: 2024-05-21
Post by lzml on Safety
CODESYS Forge
talk
(Post)
I have a problem with a project that uses EtherCAT Safety. The project is developed with CODESYS version 3.5.19.20, runtime 3.5.18.30, safety CPU EL6900 4.3.1.0, TCEL6900FBS 3.5.1.10, IODrvEL6900 4.3.1.0, IODrvEtherCAT 4.1.0.0. The safety project works correctly, but when I download the PLC project for modifications, the ESM objects are no longer aligned with the states inside the safety program. Specifically, inside the safety program, they are seen as true, while outside the safety program, the state is reported as false, but not for all ESMs, only some. I have already tried to completely redo the safety from scratch, but nothing has changed. Any solutions? Thanks
Last updated: 2024-05-24
Post by damian177 on CM4S GPIO's in Codesys
CODESYS Forge
talk
(Post)
Hi, I am running my application on device based on Compute Module 4S (Cortex-A72 (ARMv8) 64-bit ). On this device I installed RPi Runtime in 4.11.0.0 version. In my project I use device: Codesys Control for Raspberry Pi 64SL and my project works, but I actually do not have acces to all GPIO's , because GPIOs Compute Module is available only in 3.5.16.0 version and it doesn't work. Properly work GPIOs B+/Pi2 but using this device I do not have acces to all GPIO's in CM4S. Anyone of can tell me how add GPIOs Compute Module 4.11.0.0 to my project ?
Last updated: 2024-05-28
Post by starmaxou on How to download dependencies packages for CODESYS Control for Raspberry Pi SL ?
CODESYS Forge
talk
(Post)
Hi everyone, I'm trying to install the CODESYS Control for Raspberry Pi SL package. The computer with CODESYS software is offline for security reasons. So, I downloaded the package on another computer and installed it manually. But this package has dependencies packages: CODESYS.Control SL Extension Package, V4.0.0.0 CODESYS.Control SL Deploy Tool, V4.10.0.0 As I said, the computer with CODESYS is offline. I cannot use the package installer to search for these packages. I did not find them in Codesys Store with another computer. Do you know where to find and download them? Thank you in advance for your help!
Last updated: 2024-05-30
Post by kronlundo on Licensing info not available (WAGO PFC200 + Codesys V3)
CODESYS Forge
talk
(Post)
Hi! We're using a WAGO PFC200 for several projects towards the energy sector, and recently upgraded to CODESYS V3. We have the "IEC 60870-5-104 Server" package in a test program, and it works well with the package in DEMO mode. However, when we acquired a license for the "IEC 60870-5-104 Server" package and tried to add the license on the PFC200 through the license manager, we get an error (see attached file). It seems like there is no CmContainer on the device, does anyone have an idea on how to fix this? We've also contacted WAGO on this issue a while back with no feedback yet.
Last updated: 2024-06-10
Post by mborchert on PFC100 Error "Bus not running"
CODESYS Forge
talk
(Post)
Hello, i currently want to use a wago 750-8102 with the "codesys control for pfc100" runtime. I want to add the devices connected to the internal pfc100 bus via the "search devices" tab. This was reccommended in the following thread: https://forge.codesys.com/forge/talk/Deutsch/thread/7701332199/ But whenever i try to search for devices codesys just doesnt find anything and i cant close the "search devices" window. Has anyone got an idea what the problem might be? I already tried adding the devices connected to the pfc100 manually but the bus just doesn´t start. best regards Moritz
Last updated: 2024-06-17
Post by aria13 on Has anyone fed ESP32 sensor data into CODESYS (via MQTT/Modbus)?
CODESYS Forge
talk
(Post)
Has anyone tried sending live sensor data from an ESP32 into a CODESYS runtime (for example via MQTT gateway or a Modbus bridge) to trigger PLC logic? I was reading an ESP32 → MQTT tutorial (https://www.theengineeringprojects.com/2021/11/esp32-mqtt.html) that shows how easy it is to publish sensor data from an ESP32, and I’m wondering how practical that is when tying the stream into industrial control software like CODESYS. I’ve also seen Arduino forum threads where people relay sensor streams to MQTT brokers and Raspberry Pi projects that bridge MQTT→Modbus, so I’m mainly curious about real-world issues: reliability, message latency, and simple patterns you’d recommend for safe PLC integration. Any tips, examples, or gotchas from folks who’ve done this?
Last updated: 2025-10-29
Post by miltos on licensing question
CODESYS Forge
talk
(Post)
Greetings to all, I'm working on a webvisu project on control win V3 x64 runtime, and have purchased 3 licenses for my application. -Codesys Control Standard M -Codesys Visualization L -Codesys Communication M I have them installed on a Codesys usb dongle When I try to download the program, a login error window appears with the message "No valid license found for the webvisualization". The control win v3 communicates with 3 plc, and have enabled communication over codesys V3 communication by adding one datasource for every plc in the datamanager. If I remove the data manager from the project, the rest of the visualisation can be downloaded normally. Do I need to purchase another License and which one? Please find attached the software metrics and the error screen.
Last updated: 2025-10-31
Post by msirotkin on EtherCAT status errors
CODESYS Forge
talk
(Post)
Hello, I'm trying to understand the reason for the many errors on the EtherCAT master status page. If we set the cycletime to 1ms we see a lot of rxerrors and lostframes, but the send and recive times are quite good (see attachement). And the status of the EtherCAT bus is good (no other errors, all is green, slave has no errors) But when we set 2ms cycletime the lostframe errors are gone, but periodically increses rxerror counter (see attachement). The questions is, what do these errors actually mean and what we can do to get gid of them? Linux RT, imx8, Codesys runtime for ARM 3.5.21.10, Ethercat 4.10 Thanks
Last updated: 2025-11-25
Post by pernockham on Unable to deploy "Control for Linux SL 4.18.0.0"
CODESYS Forge
talk
(Post)
The option to update "Control for Linux SL" is not shown in the "deploy control SL tool", I can see and update the gateway but not the control (3.5.21 SP4). Has the way to update control SL changed? In the process of fault finding I removed the control SL entirely from my target, then I had to revert to version 3.5.21.0 SP 1 to re-install "Control SL 4.17.0.0". So I thought it was just a matter of using SP1 to update also to 4.18.0.0, but after installing the files for 4.18.0.0 in the SP1-version, the behavior was identical to SP4, ie no Control for Linux SL shown in the deploy tool.. See screenshots.
Last updated: 2025-12-19
Post by mait-tim on Drive communication errors
CODESYS Forge
talk
(Post)
With a machine I'm working with i get a communication error when I'm updating some softstop limits. As soon as I update the code the drives do not want to operate. Using the MC_readStatus I'm receiving errors as soon as i want to start a movement. Using MC_ReadAxisError i see that i receive error 131, no response. With a SMC3_ETC_ReadParameter_CoE i do not recieve any driver errors. Does anyone know how i can figure out what the error is and how to solve it. When i go back to the old software no errors occur. Im working with a legacy machine running a Beijer PLC with some Mitsubishi drives. running on Codesys 3.5 SP10. the runtime version is probably 3.5.3. The drives are all Ethercat Drives (CoE). All using the SM3_drive_ETC libary and the SM3_basic library.
Last updated: 2025-12-22
Post by timvh on CPU + EtherCAT redundancy
CODESYS Forge
talk
(Post)
It works well with two Wago 750-8210's. I helped a few customers setting this up. But it should work with any device which can control EtherCAT I/O, is real-time and has sufficient network interfaces. Two network adapters can be used to create a redundant EtherCAT network (you need 2 additional switches for this). The other network adapters can be used to interconnect the 2 PLC's (synchronization). We noticed that if you exchange variable lists that there could be some issues if you have long lists. So what we did is use a SoftPLC on a server that contains all the settings which continuously sends network packages (GVL sender) and which is received by both PLC's (network receiver). Switching over is done in milliseconds. The bus doesn't notice the change-over. EtherCAT communication works flawlessly.
Last updated: 2026-01-30
Post by gatto on Two licenses have to be installed forgot to enable one license
CODESYS Forge
talk
(Post)
Sorry, I've never used Raspy. Maybe someone else can help. From personal experience, I've had license activation issues, but it was caused by my company firewall, which was blocking traffic from the Codesys license server. So I found that the license was listed as activated on the server (and therefore used and no longer activable), but it wasn't present in the PLC. I solved the problem by using an unblocked internet connection when I needed to activate the purchased license ticket. Since then, the activation process has always worked, and I've never lost any licenses.
Last updated: 2026-02-03
Post by winki on Error in licence activation
CODESYS Forge
talk
(Post)
Hello, I think I understand: On my debian gateway I have done: sudo cmu --list cmu - CodeMeter Universal Support Tool. Version 8.30a of 2025-May-06 (Build 6885) for Linux/ARMHF 64-Bit Copyright (C) 2007-2025 by WIBU-SYSTEMS AG. All rights reserved. List all locally connected CmContainers: - CmContainer with Serial Number 130-XXXXXXXX and version 3.00 (empty) - CmContainer with Serial Number 130-XXXXXXXX and version 3.00 (locked) Result: 2 CmContainer(s) listed. The licence has been activated with a computer Name, but the guy who did it make a mistake in the name, so he changed it after to have activate the licence. I think this has created a second container. The licence is actived on the other container.