Search talk: real to array

 
<< < 1 .. 15 16 17 18 19 .. 177 > >> (Page 17 of 177)

Post by talhaali on Alarm Manager: CODESYS Forge talk (Post)
Hi, I am trying to access active alarms in code(As alarm count variable updates only when we go to to alarm table frame in visualization). I wrote following code but it is not working: VAR iCountActiveAlarms : INT; parritfActiveAlarms : POINTER TO ARRAY[0..0] OF IAlarm; itfAlarmManagerClientAll : IAlarmManagerClient; END_VAR AlarmManager.g_AlarmHandler.GetActiveAlarms( itfAlarmManagerClient :=itfAlarmManagerClientAll, iCountActiveAlarms => iCountActiveAlarms, parritfActiveAlarms => parritfActiveAlarms); The Value is always 0. Please help.
Last updated: 2024-06-06

Post by talhaali on Alarm Table Issues CODESYS Forge talk (Post)
Hi, I am trying to access active alarms in code(As alarm count variable updates only when we go to to alarm table frame in visualization). I wrote following code but it is not working: VAR iCountActiveAlarms : INT; parritfActiveAlarms : POINTER TO ARRAY[0..0] OF IAlarm; itfAlarmManagerClientAll : IAlarmManagerClient; END_VAR AlarmManager.g_AlarmHandler.GetActiveAlarms( itfAlarmManagerClient :=itfAlarmManagerClientAll, iCountActiveAlarms => iCountActiveAlarms, parritfActiveAlarms => parritfActiveAlarms); The Value is always 0. Please help.
Last updated: 2024-06-06

Post by talhaali on Alarm status in logic CODESYS Forge talk (Post)
Hi, I am trying to access active alarms in code(As alarm count variable updates only when we go to to alarm table frame in visualization). I wrote following code but it is not working: VAR iCountActiveAlarms : INT; parritfActiveAlarms : POINTER TO ARRAY[0..0] OF IAlarm; itfAlarmManagerClientAll : IAlarmManagerClient; END_VAR AlarmManager.g_AlarmHandler.GetActiveAlarms( itfAlarmManagerClient :=itfAlarmManagerClientAll, iCountActiveAlarms => iCountActiveAlarms, parritfActiveAlarms => parritfActiveAlarms); The Value is always 0. Please help.
Last updated: 2024-06-06

Post by timvh on Array to String CODESYS Forge talk (Post)
The string_Util_Intern is not the library I referred to. With a CONCAT function (also with the string util library) a search is done for the NULL character. If you concatenate 20000 characters to one string, then the longer the string, the longer it takes to find this NULL character.
Last updated: 2024-07-24

How to use matlab to send parameters to codesys CODESYS Forge talk (Thread)
How to use matlab to send parameters to codesys
Last updated: 2018-10-10

Post by apurv on Cannot pass array of constant size to a function as a reference CODESYS Forge talk (Post)
Could not find the solution to this issue but I have side stepped this by creating a global variable MAX_SIZE.
Last updated: 2024-01-08

Post by kuuki on Losing focus of variable CODESYS Forge talk (Post)
Hi. Does anyone know how to fix a problem with losing focus of a variable in FBD editor. Sometimes when trying to edit variable name, array index, etc. in network, editor randomly exits "text edit mode" and variable is replaced by text you were typing.
Last updated: 2024-03-26

Post by drml on Array to String CODESYS Forge talk (Post)
If a size is not specified, CODESYS allocates 80 characters by default for a string. After 7 seconds, does your Json_string contain all of your 20000 key/values? Or is the result truncated to 80 characters?
Last updated: 2024-07-19

Post by mmpl on Array to String CODESYS Forge talk (Post)
Hi Thank you for you reply. Yes I can concatenat longer string. I am using string_Util_Intern libraray for concat. The issue is abot plc performance. It takes 7 second. I am looking to improve time.
Last updated: 2024-07-23

Post by simotion on Pointer to Softmotion axis CODESYS Forge talk (Post)
In my projet I use Softmotion. There are several Softmotion axis (type SM_Drive_Virtual). In the Global Variable List I have an array of pointers to the adress of the Axis. Axis : ARRAY[1..iMaxCntAxes] OF POINTER TO AXIS_REF_SM3 := ADR(AX01_Axis), // [1 ADR(AX02_Axis), // [2] This works, but when compiling I get the message : . [WARNING] E3D: GVL Device: PLC Logic: Application: C0564: A reference to uninitialized variable AX01_Axis is used for initialization of Axis. Accessing the uninitialized variable may result in unexpected behavior. [WARNING] E3D: GVL Device: PLC Logic: Application: C0564: A reference to uninitialized variable AX02_Axis is used for initialization of Axis. Accessing the uninitialized variable may result in unexpected behavior. Is there a way when initializing to force the hardware (softmotion axis) to first initialize and then the Global Variable List?
Last updated: 2023-10-25

Post by janderson on OPC UA Server limitations, large array crashes runtime CODESYS Forge talk (Post)
What are the limitations of the OPC UA Server? I am trying to get data off my PLC that is acquired at high rates (~50k samples/s) so I am storing them in arrays and trying to get the arrays off the PLC. When I attempt to read a ~200k element array through OPC UA the server and runtime crashes (requiring tools -> update linux arm64 -> start runtime). Is there a better way to get highspeed data off? The ACDatalog library seems a bit irritating to use so I would prefer to go through OPC UA.
Last updated: 2023-08-23

VAR_IN_OUT, POINTER TO and REFERENCE TO CODESYS Forge talk (Thread)
VAR_IN_OUT, POINTER TO and REFERENCE TO
Last updated: 2021-11-16

Unable to connect to this device CODESYS Forge talk (Thread)
Unable to connect to this device
Last updated: 2024-06-28

Post by k2saki on How to define CONDITIONAL PRAGMA that effects all ST-POU in project. CODESYS Forge talk (Post)
I'd like to use same code/project in different devices. (RPi, PLC) I change some lines in some POU before compiling. (array size, file path, etc ) My question is How to define pragma that effects all ST-POU in project. Is it possible ? I've read this. https://help.codesys.com/api-content/2/codesys/3.5.12.0/en/_cds_pragma_conditional/
Last updated: 2024-05-12

Post by timvh on Array to String CODESYS Forge talk (Post)
The new (UTF8) string library is faster and can handle large strings. https://content.helpme-codesys.com/en/CODESYS%20String%20Libraries/_strlib_start_page.html PS, in CODESYS, the maximum string length is not 255 characters. The String functions of the standard library are limited to strings of 255 characters. But you can use other (memory) functions to handle strings larger than 255 characters.
Last updated: 2024-07-22

Post by imuser on Is it possible to use debug functions such as Step Execution while the PLC ladder is in Running? CODESYS Forge talk (Post)
Hello, I am a student learning CODSIS. Lately, I've been curious about something. During the actual PLC run, that is, Assume that the I/O is connected to a physical device and the analog value is updated in real time. Is it possible to use a feature like Codesys’ Debug-Step Over-Step IN? If possible..... How do I process the values of analog values (pressure sensor, temperature, current, etc.) that are being updated in real time? To step over, the ladder must stop at the breakpoint. If that happens, the PLC will actually stop, right??
Last updated: 2024-01-16

Post by spiessli on Softmotion axis to CANopen Maxon IDX drive CODESYS Forge talk (Post)
Just verified the behaviour. Still is the same. It should be attached here. But I also tried the DCF-file with the axis in the lab with the real drive: The MC_Power block never goes out of busy. Had not time to investigate further, though.
Last updated: 2024-01-08

Post by davidbo on Is it possible in the log to see previous shutdown CODESYS Forge talk (Post)
If my application does some kind of violation which makes it cast an exception it will trigger my real watchdog which results in a reboot. Unfortunately the log it seems only shows the boot sequence. Is it possible to see what happen before reboot?
Last updated: 2024-02-08

Post by lbartik on MPC predictive control CODESYS Forge talk (Post)
Would this work? https://www.mathworks.com/hardware-support/codesys.html I'm also interested in real-world MPC and have no idea where to start. There is an exciting Python library that is also beyond my grasp: https://www.do-mpc.com/en/latest/index.html Step 1, get PhD(s). Step 2, get job in aerospace/robotics. Step 3, return 15 years later to share this knowledge?
Last updated: 2024-10-19

Post by gilbertamine on Comparing Arrays of structure CODESYS Forge talk (Post)
Hi Everybody, I'm looking for a simple way of comparing two array of a structure. My structure is define like this : TYPE Positions_T : STRUCT PosX: DINT; PosY: DINT; PosZ: DINT; END_STRUCT END_TYPE I have multiples Var : ARRAY [0..220] OF Positions_T, that I need to compare quickly. I don't really want to do a Loop that goes by every 220 points and compare each one of them so I was wondering if there is another way. I came accross the MEM.Compare function, but it require to know the size in Bytes of the memory, and I don't know how to do that... Has anybody an idea on how to do the comparing easily ? Thanks in advance
Last updated: 2024-08-22

Post by mxj262 on FB having single input but initialized with Array CODESYS Forge talk (Post)
Last updated: 2024-05-04

Post by mxj262 on FB having single input but initialized with Array CODESYS Forge talk (Post)
works
Last updated: 2024-05-06

Post by hwillems on Ranges, Lambdas, on Fixed arrays of structs CODESYS Forge talk (Post)
I do datastructures and algorithms in Codesys. For example a Struct of Person with thing's like IdNumber, Name, Age etc. as example. Now i do all kind of calculations, filters. So i have this pretty big Fixed Array with Structs. On this struct i want to do simple stuff you can do easily in C++/Python/Rust etc. For example i want to do this: AvererageAge := Average(Peoples.Age); Then it will return the average of all members ages. Or Sort struct on age etc. Or sort on alphabetical Name. Or use Lambda functions to filter/mutate out things like, filter out everybody above 18 years old. Or remove people who it's name start with "A". Currently i have to write my own custom function for example sorting on Age. And make a super specific function based on that particulare datastructure. Here an Example: (*Before calling this FIlter method, set the mNodeFilterSwitch to the desired filter.*) CASE mNodeFilterSelect OF (********************************[ Status Filters ]***********************************) NodeID: FOR x := ACS_OUT_BEGIN TO ACS_OUT_END BY 1 DO FOR y := ACS_IN_BEGIN TO ACS_IN_END BY 1 DO IF marrNode[y].Status.oiNodeID > marrNode[y + 1].Status.oiNodeID THEN mNodeTemp := marrNode[y + 1]; marrNode[y + 1] := marrNode[y]; marrNode[y] := mNodeTemp; END_IF; END_FOR; END_FOR; Started: FOR x := DES_OUT_BEGIN TO DES_OUT_END BY -1 DO FOR y := DES_IN_BEGIN TO DES_IN_END BY -1 DO IF marrNode[y].Status.oxStarted > marrNode[y - 1].Status.oxStarted THEN mNodeTemp := marrNode[y - 1]; marrNode[y - 1] := marrNode[y]; marrNode[y] := mNodeTemp; END_IF; END_FOR; END_FOR; Starting: FOR x := DES_OUT_BEGIN TO DES_OUT_END BY -1 DO FOR y := DES_IN_BEGIN TO DES_IN_END BY -1 DO IF marrNode[y].Status.oxStarting > marrNode[y - 1].Status.oxStarting THEN mNodeTemp := marrNode[y - 1]; marrNode[y - 1] := marrNode[y]; marrNode[y] := mNodeTemp; END_IF; END_FOR; END_FOR; END_CASE; I have like 30+ of these in the enum. Not really DRY code right? These are custom made bubble sort filters in a function. You pass in the Datastructure, and say what function you want. (This is an enum collection of sorting functions) And then the Array with Nodes of Structs gets ordered. Why can't we have Iterators and Lambda's and build in standard functions like regular languages? Also i use bubble sort because it's the easiest to implement because i can't get this to code DRY. Problem with ST (Even the new one with classes) that it's very limited for programming datastructures and algorithms. Yes you still not want dynamic memory and you need to choose the correct algorithm so you know the most extreme edge cases regarding the time it takes to execute the algorithms.(Real-time execution) How are other people dealing with this? Here for example saw some software using an adjusted ST language and having FOR EACH possibility: https://www.fernhillsoftware.com/help/iec-61131/structured-text/st-for-each.html You can then build your own custom Iterator functions. I wish the IEC 61131-3 standard would be more expressive and having more standard modern features, but still keep close to the fact of no dynamics memory and real-time systems.
Last updated: 2023-08-31

Post by mozed on Connection to device closed CODESYS Forge talk (Post)
Hello I am using an OpusA3 with version 3.5 SP17 Patch 3 as part of a project. I had no real problem before I encountered a problem that blocked me. The detection of the OpusA3 from Codesys is done correctly. The gateway is well configured and if I ping the gateway or the OpusA3 I receive the response correctly. The problem is that when I try to connect, the Opus screen freezes and a few moments later Codesys displays an error message ("connection to device closed"). I tried to change PC, to update the runtime, to change OpusA3 but the problem remains the same. I'm a little lost knowing that before it worked without problem. I went back to a previous version of the project (where it worked correctly) but the message still appears. Do you have any clues to solve the problem? Sincerely,
Last updated: 2023-08-23

Post by timvh on Profinet fault with codesys control V3 - Receive packet error CODESYS Forge talk (Post)
Are you using the Control Win SL (installed together with the development environment of CODESYS)? If yes, you might want to consider using the CODESYS RTE instead. This has real-time capabilities (running on separate core(s)). But to be able to use this, you have to install the CODESYS Ethernet driver for your network interface to be able to let the RTE access the network port also in realtime. See: https://store.codesys.com/en/codesys-control-rte-sl-bundle.html https://content.helpme-codesys.com/en/CODESYS%20Control/_rtsl_windows_rts_v3.html PS, I haven't tested this myself yet, but you could try to use the SetCommunicationState method of the Profinet controller to see if you can reset and start the bus communication: result := PN_Controller.SetCommunicationState(eRequestedState := DED.DEVICE_TRANSITION_STATE.START); PS, if you are located in the Netherlands or Belgium, we could also provide the license(s) for you.
Last updated: 2024-02-28

<< < 1 .. 15 16 17 18 19 .. 177 > >> (Page 17 of 177)

Showing results of 4425

Sort by relevance or date