Post by davidmic on What is this ST syntax?
CODESYS Forge
talk
(Post)
I found some structured text code which contained this statement: bHidden:= TRUE(*NOT _somevariable*) I haven't seen TRUE() used like a function before, and I also haven't seen the enclosing asterisks * * before. What do they do? (sorry if this is a duplicate question, I don't know what words to use to search for this syntax)
Last updated: 2024-10-11
Post by eschwellinger on Scan Network on gateway created with Control Sl
CODESYS Forge
talk
(Post)
it seems that the device you scan, is not the same type which you have added to the project in CODESYS. Virtual Control is Arm 64 SL so please select this type in CODESYS when you generate a new Application..or right click to the device- update device - virtual Control Arm 64 SL
Last updated: 2024-10-16
Post by andrax on CodeSys Raspberry pi I2C driver not found
CODESYS Forge
talk
(Post)
Ok, this is a test programme with ADS1115. It is currently configured for the TCA9548 muxboard. If you want to run the ADS1115 single, then change the settings to the default values: ‘Is Multiplex:’ False ‘Stage mux channel numbers:’ [0,0,0,0,0,0,0,0,0] It is also important that the libraries are installed correctly here. But should be in this project
Last updated: 2024-11-07
Post by secundino on License
CODESYS Forge
talk
(Post)
Good morning, I need to activate a CODESYS license on your website, as the computer where it was originally installed has been formatted. I have already sent two emails to store-support@codesys.com, but I have not received a response yet. Could you please assist me with this issue as soon as possible?
Last updated: 2025-02-20
Post by secundino on License
CODESYS Forge
talk
(Post)
Good morning, I need to activate a CODESYS license on your website, as the computer where it was originally installed has been formatted. I have already sent two emails to store-support@codesys.com, but I have not received a response yet. Could you please assist me with this issue as soon as possible?
Last updated: 2025-02-20
Post by alawwirbilal on Codesys for raspberry pi 5 not working exactly
CODESYS Forge
talk
(Post)
Hello, I have installed the runtime system on my raspberry pi 5 and when I scan for the devices it sees. But when I try to log in to the device it always ask me for a password and no matter what I give it says this is a wrong password. anyone could help?
Last updated: 2025-03-06
Post by jba-eltech on Moving Frames
CODESYS Forge
talk
(Post)
Hello everyone. I am using Codesys and saw in a YouTube video on the Codesys channel (https://www.youtube.com/watch?v=y_l2siXY7dA) that you can create frames and move them with the mouse. However, the video does not show how to do this. Can someone please explain it to me? Thank you very much.
Last updated: 2025-04-01
Post by snguyen on Atomic and Shared memory?
CODESYS Forge
talk
(Post)
Hi, I've read that you can perform Atomic instructions like AtomicReadLInt on variables. However, I'd like to know if this uses stdatomic internally. My main question is : Is it possible to share atomic types in shared memory with CodeSys. If so, what types should they be declared as? If not, are the atomic functions lock-free or does it use a mutex?
Last updated: 2025-04-15
Post by programmer on 3.5 P20 hangs - no response
CODESYS Forge
talk
(Post)
hi imdatatas, thanks for your suggestion! I added the process execution to be sure. In the meantime I reïnstall Windows but it dind't help directly. Finally I deleted CodeMeter Runtime Server after Codesys installation. Because this Service was not able to start. And it works (for now) :)!
Last updated: 2025-06-25
Post by llewv123 on Codesys Control for RPi and Waveshare AD/DA hat
CODESYS Forge
talk
(Post)
Good day, I am attempting to use a Waveshare AD/DA precision HAT with RPi 4B+, using Codesys Control for Rpi. The waveshare hat uses SPI. I am successfully using the RPi GPIO (inputs and outputs) but do not know how to access the AD/DA channels. Any help would be appreciated.
Last updated: 2025-08-04
Post by ulvis on Where to find the OPC-UA Information Model Repository
CODESYS Forge
talk
(Post)
Now, for CODESYS v3.5 SP21 I can no longer find the "OPC UA Information Model Repository" entry to add as a command. In the "Tools" menu it is listed but greyed out, reporting "Plug-in is not available". So how do I add the Plug-in?
Last updated: 2025-08-14
Post by raamkumar on exple1
CODESYS Forge
talk
(Post)
```structured text VAR bStartButton : BOOL; // Start button input bStopButton : BOOL; // Stop button input bMotorRunning : BOOL := FALSE; // Motor running status END_VAR // Motor control logic IF bStartButton AND NOT bMotorRunning THEN bMotorRunning := TRUE; // Start motor END_IF; IF bStopButton THEN bMotorRunning := FALSE; // Stop motor END_IF; // Output to motor driver (replace with your actual output) // Assume 'qMotor' is a boolean output to the motor driver. qMotor := bMotorRunning;
Last updated: 2025-08-23
Post by leandroct on Creating Boot Application not working
CODESYS Forge
talk
(Post)
I did these steps and it worked: - Copied Application.app and Application.crc to the Folder C:\ProgramData\CODESYS\CODESYSControlWinV3x64\ID_of_CPU\PlcLogic\Application\ copied the visu folder content to the folder C:\ProgramData\CODESYS\CODESYSControlWinV3x64\ID_of_CPU\PlcLogic\Application\visu\ Changed by Notepad the CODESYSControl.cfg at the folder C:\ProgramData\CODESYS\CODESYSControlWinV3x64\ID_ of_CPU\ Where is [CmpApp], adding a line with: Application.1=Application
Last updated: 2025-09-04
Post by pernockham on Gateway in China - "Gateway not connected"
CODESYS Forge
talk
(Post)
Gateway and runtime (Control for linux SL) on a debian linux. Thanks for your check. Good to know. I will probably travel there in about a months time so that will give me better possibility for further testing. (on a side note, I dont get mail-updates on forum-subscriptions, need to check the topics manually)
Last updated: 2025-09-26
Post by felixal on Codesys automatic Data transfer to USB on rasberry pi
CODESYS Forge
talk
(Post)
Hi all, I am currently working on a project where I need to save data automatically on many diffrent USB-Sticks, which are always plugged in the same USB-Port on a Rasberry PI, but I do not get how I can automatically detect the USB devices Folder Name and save a file there on Linux. Thanks!
Last updated: 2024-01-03
Post by kleeswi on SysFileOpen does not work after update to V3.5 SP19 Patch 5
CODESYS Forge
talk
(Post)
Finally this solved my issue: https://forge.codesys.com/forge/talk/Engineering/thread/3da9ded84e/, and the official documentation https://faq.codesys.com/display/CDSFAQ/SysFile%2C+Persistence+Manager%2C+Datalog+Manager . Add the media folder to the PlaceholderFilePath. Like this: PlaceholderFilePath.2=/media/pi, $usb$ PlaceholderFilePath.2.View=1 PlaceholderFilePath.2.Volatile=1
Last updated: 2024-02-19
Post by hwopereis on Codesys Control shutdown
CODESYS Forge
talk
(Post)
Hi, I'm experiencing this problem as well. Did the suggested combination resolve your issues in the end? If not, I can stop my efforts rolling back to these versions. I'm trying to get CC for RPi 4.8.0.0 installed on the device, but I can't find it after installing it through the packet manager.
Last updated: 2024-03-25
Post by phoward131 on Numpad decimal value requires leading zero
CODESYS Forge
talk
(Post)
I have noticed on the standard numpad dialog, if a user enters a purely decimal number (ie '.6'), the numpad will not accept the value but gives no indication. One must type a leading zero (ie '0.6') in order for it to work. Is there a way to correct this so that a user can just type the decimal value?
Last updated: 2024-04-30
Post by walkercope on Ethercat bus on Beckhoff CX with Codesys for Linux
CODESYS Forge
talk
(Post)
Has anyone figured out a way to use the ethercat bus on a beckhoff CX using codesys running on linux? Using ethercat on the native NICs works fine but I get a "packet could not be sent" error when trying to scan the ethercat bus device. Errors and hardware in attached image.
Last updated: 2024-05-13
Post by seler on Custom button with output status
CODESYS Forge
talk
(Post)
Hi, Im struggle with making custom button. The idea is simple grey light bulb after touch (input var) it changes to yellow but shows output var status not switch status. So if light is physically on, switched by physical switch, bulb is also yellow. How to do it?
Last updated: 2025-11-18
Post by althafu on Codesys v 3.5 to factory IO
CODESYS Forge
talk
(Post)
I have been following the steps shown in the RealPars video to connect CODESYS with Factory I/O. The connection works correctly when I use Ladder Diagram, but when I try the same simple input–output logic in Structured Text, the simulation does not behave as expected. Has anyone experienced this issue or knows what might be causing it?
Last updated: 2025-11-20
How to configure CODESYSControl_User.cfg in order to use a specific network card for OPCUA Server
CODESYS Forge
talk
(Thread)
How to configure CODESYSControl_User.cfg in order to use a specific network card for OPCUA Server
Last updated: 2023-08-28
how to transfer raspberrypi runtime license from sdcard to dongle without the original raspi?
CODESYS Forge
talk
(Thread)
how to transfer raspberrypi runtime license from sdcard to dongle without the original raspi?
Last updated: 2021-04-13
How to intercept a variation in the RetainPerstist variables (for saving to file)
CODESYS Forge
talk
(Thread)
How to intercept a variation in the RetainPerstist variables (for saving to file)
Last updated: 2018-08-03
Specify Input Configuration "OnDialogClosed" Action to only react to certain Dialogs
CODESYS Forge
talk
(Thread)
Specify Input Configuration "OnDialogClosed" Action to only react to certain Dialogs
Last updated: 2023-10-02
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.