Post by jzhvymetal77 on IecVarAccessLibrary.IBaseTreeNode methon CODESYS Forge talk (Post)
I had this code working in a previous version of CoDeSys to read variables from a GVL that were added to the Symbol configuration. The problem now is that when I get the _IBaseTreeNode_Parent, it returns a valid interface, but none of the methods or properties work. If you monitor the _IBaseTreeNode in the watch window, it does show the correct child count. However, it fails at step 30, where the child count incorrectly returns zero. In the image, you can see that the watch window displays the correct value that the property should return. Attached is the full project code. FUNCTION_BLOCK Symbols_TO_STR VAR_INPUT i_sPath : STRING(255); i_diIndexChild : DINT; i_diIndexComponent : DINT; END_VAR VAR_OUTPUT q_diChildCount : DINT; q_diComponentCount : DINT; q_sName : STRING(255); q_sValue : STRING(255); q_sType : STRING(80); q_sErrorResult : STRING(80); END_VAR VAR uiStepCopy : UINT; uiStep : UINT; uiStepProcessCopy : UINT; uiStepProcess : UINT; _IBase : IecVarAccessLibrary.IBase; _pIIecVarAccess5 : POINTER TO IecVarAccessLibrary.IIecVarAccess5; _IIecVarAccess5 : IecVarAccessLibrary.IIecVarAccess5; _RTS_IEC_RESULT : IecVarAccessLibrary.RTS_IEC_RESULT; _udiResult : UDINT; _VariableInformationStruct : IecVarAccessLibrary.VariableInformationStruct; _IBaseTreeNode_Parent : IecVarAccessLibrary.IBaseTreeNode; _IBaseTreeNode_Child : IecVarAccessLibrary.IBaseTreeNode; _ITypeDesc_Child : IecVarAccessLibrary.ITypeDesc; _TypeDescAsUnion_Child : IecVarAccessLibrary.TypeDescAsUnion; _arIBaseTreeNode_Child : ARRAY[0..20] OF IecVarAccessLibrary.IBaseTreeNode; _TypeClass_Child : IecVarAccessLibrary.IBaseLibrary.TypeClass; _psSymbolName_Child : POINTER TO STRING; _sSymbolName_Child : STRING(255); _IBaseTreeNode_Component : REFERENCE TO IecVarAccessLibrary.IBaseTreeNode; _TypeClass_Component : IecVarAccessLibrary.IBaseLibrary.TypeClass; _ByteAddress_Component : __XWORD; _ByteOffset_Component : __XWORD; _sArrayIndexName_Component : STRING(20); _diArrayIndexCalc_Component : DINT; _diArrayIndexValue_Component: DINT; _psSymbolName_Component : POINTER TO STRING; _sSymbolName_Component : STRING(255); END_VAR uiStepCopy:=uiStep; uiStepProcessCopy:=uiStepProcess; CASE uiStep OF 10: // GET IBASE FROM CURRENT APP _IBase:= IecVarAccessLibrary.IecVarAccGetFirstInterface2(0); IF _IBase<>0 THEN uiStep:=20; ELSE q_sErrorResult:=CONCAT(UINT_TO_STRING(uiStep), ': IecVarAccGetFirstInterface2'); uiStep:=9000; END_IF 20: //QueryInterface IIecVarAccess5 from IBASE _pIIecVarAccess5 := _IBase.QueryInterface(IecVarAccessLibrary.ITFID_IIecVarAccess5, ADR(_RTS_IEC_RESULT)); IF _pIIecVarAccess5<>0 AND _RTS_IEC_RESULT=0 THEN _IIecVarAccess5 := _pIIecVarAccess5^; uiStep:=30; ELSE q_sErrorResult:=CONCAT(UINT_TO_STRING(uiStep), ': QueryInterface_IIecVarAccess5'); uiStep:=9000; END_IF 30: // Get IBaseTreeNode_Parent _IBaseTreeNode_Parent := _IIecVarAccess5.VarAccGetNode3(ADR(i_sPath), ADR(_VariableInformationStruct), ADR(_RTS_IEC_RESULT)); IF _IBaseTreeNode_Parent<>0 AND _RTS_IEC_RESULT=0 THEN q_diChildCount:=_IBaseTreeNode_Parent.ChildCount; uiStep:=40; ELSE q_sErrorResult:=CONCAT(UINT_TO_STRING(uiStep), ': IBaseTreeNode_Parent'); uiStep:=9000; END_IF 40: // Get IBaseTreeNod_Child IF(q_diChildCount-1>=i_diIndexChild AND i_diIndexChild >=0) THEN _IBaseTreeNode_Child := _IBaseTreeNode_Parent.GetChild(i_diIndexChild); IF _IBaseTreeNode_Child<>0 THEN uiStep:=50; ELSE q_sErrorResult:=CONCAT(UINT_TO_STRING(uiStep), ': IBaseTreeNode_Parent'); uiStep:=9000; END_IF ELSE q_sErrorResult:=CONCAT(UINT_TO_STRING(uiStep), ': i_diIndexChild OutBounds'); uiStep:=9000; END_IF
Last updated: 2025-08-20

Post by gilbert-mh on CAA net base TCP client cause PLC to crash - Kernel message : N0HZ_local_softirq_pending 80 CODESYS Forge talk (Post)
Hello all, I have been trying to implement a TCP client on a Festo PLC (CPX-E-CEC-M1) and it looks like it works well except that after some time (greatly varies between a few hours to more than 100h) my PLC crash. When I look into the log file the only thing I see is that before the crash happens a few kernel warnings : N0HZ_local_softirq_pending 80 and then the crash. I've looked into this warning and from what I could find on the net it seems that this is warning is triggered when the ethernet link is down. I've tried to correct this bug for quite some time and what I know is that : - The crash is caused by my TCP client, when I remove it from my code I see no crash - The crash happens more quickly the more the TCP client is used. - The time before the crash is not directly proportional to the number of communications or their size. But it looks like it is just more likely to happen if the client connect to the server at a higher frequency. - The precedent observation makes it seem unlikely that the crash is caused by some memory overflow because then the crash speed would be more proportional to the amount of data exchanged. SO from these observations, I believe that the crash could be caused by the PLC trying to connect to a server while there is some kind of issue with the ethernet link resulting in the PLC getting stuck in some indefinite state and making it crash. This still seems a bit unlikely to me because if the ethernet is down it simply shouldn't be able to contact the server and the communication would just fail which doesn't cause my PLC to crash. Has anyone encountered the same kind of problem (with the same kernel message) ? I am pretty sure the warning is not the direct cause of the crash but just an indicator that something is wrong with my PLC. Thanks in advance
Last updated: 2024-01-12

Post by jackbrady on Function Blocks and arrays of function blocks CODESYS Forge talk (Post)
Hello, I am new to Codesys and PLC programming in general (please go easy ha!) I'm not looking for code to be written for me just some help and pointing in the right direction. I am writing some code to send commands to a relay based on input values (to put it simply). Quite basic stuff. I have wrote a function block that takes a global variable (Open_command:BOOL) and outputs to another global variable (Opened : BOOL). The function block is simulating a device so I'll eventually get the globals from that. I now need to create multiple versions of this function block/ device (lets say 100) but I need each iteration of that function block to reference it's own relevant global variable. I think that the best way of doing this would be to use arrays, although I could be wrong. I am aware that for up to 100 instances I could very well manually assign everything but that seems rather time consuming and I want a fancier way of doing it. Here is a very basic example of what I am looking to do, please note I have not written this in proper code it's just to show what I mean. Global Variables V[0-100] int Open_command [0-100] Bool Opened [0-100] Bool Function Block var input x : BOOL Var output y : BOOL if x then y = TRUE ELSE y = FALSE The input to my function block will be Open_command, output will be Opened Example code. If V[x] > 10 then Open_command [x] = TRUE ELSE Open_command [x] = FALSE (So when V1 goes above 10 I need Open_command1 = TRUE therefore initiating FB1 output. V2 > 10, open_command2 = True > FB2 output V3 > 10, open_command3 = True > FB3 output ... ... ) What I can't seem to figure out is how to tie all this together, I have read through the codesys documentation and if anything it has confused me more! ha. Apologies for the poorly written post but hopefully you understand what I am trying to get at. Thanks, Jack
Last updated: 2024-02-14

Post by risele on dynamic modbus devices CODESYS Forge talk (Post)
Have the same issue: I'm making a test setup for modbus devices testing and calibration. One is run for every possible address, and it starts with minimal request: if the device is found, it continue to work with it, otherwise it's set to Disabled temporary. Those state machines are running under FOR cycle, and disabled are just skipped. Every instance have its own timer for not running too frequently and a start delay, so the actual requests are separate in time. I also check not for a single error, but have some timer to allow one-two timeouts. The small program disables and re-enables devices temporary (manually, since i could not iterate over MB devices). VAR Reset:ARRAY[1..GVL_MB.MD_COUNT] OF R_TRIG; i:INT; END_VAR {IF hasconstantvalue(GVL_MB.MD_COUNT, 1, >= )} i:=1; MD_1.Enable:=GVL_MB.MDPortsEnable[i]; Reset[i](CLK:=GVL_MB.MDPortsEnable[i]); MD_1.xReset:=Reset[i].Q; {END_IF} {IF hasconstantvalue(GVL_MB.MD_COUNT, 2, >= )} i:=2; MD_2.Enable:=GVL_MB.MDPortsEnable[i]; Reset[i](CLK:=GVL_MB.MDPortsEnable[i]); MD_2.xReset:=Reset[i].Q; {END_IF} There is also program to re-enable devices periodically. METHOD ScanBus VAR_INPUT END_VAR VAR j:INT; (*block auto scanning if calibration is running for any device since it's data-reach process that should not be interrupted with modbus timeouts *) CalibrationBusy:BOOL:=FALSE; END_VAR CalibrationBusy:=FALSE; FOR j:=1 TO GVL_MB.MD_COUNT DO CalibrationBusy:=CalibrationBusy OR MD_Calibrate.AutoTesters[j].xBusy; END_FOR; IF CalibrationBusy THEN RETURN; END_IF tBusScanSchedule(IN:=(NOT tBusScanSchedule.Q), PT:=tBusScanPeriod); IF (NOT tBusScanDelayer.Q) AND (tBusScanSchedule.Q OR (NOT xFirstScanPerforemed)) THEN xBusScanBusy:=TRUE; MissingCounter:=0; xFirstScanPerforemed:=TRUE; FOR j:=1 TO GVL_MB.MD_COUNT DO (* MD_Calibrate is main calibration program. Identifiers - is array of State machines mentioned above Phase_Faulted is a state of Identifiers where I'm sure device is missing on the bus *) IF MD_Calibrate.Identifiers[j].state=eStateMDIdentifier.Phase_Faulted THEN MD_Calibrate.Identifiers[j].Rescan(); MissingCounter:=MissingCounter+1; END_IF END_FOR END_IF tBusScanPauser(IN:=tBusScanDelayer.Q AND (MissingCounter>0),PT:=tBusScanDelay*MissingCounter); xBusScanBusy:=tBusScanPauser.Q; xFirstScanPerforemed:=xFirstScanPerforemed OR tBusScanPauser.ET>=tBusScanPauser.PT; Also the GUI have buttons for each address possible that re-enables the device if required.
Last updated: 2026-02-13

Post by toby on Ethercat Servo Setup CODESYS Forge talk (Post)
Hi Everyone, I have a simple project with a single servo, but its my first time using Codesys and motion, so I'm a little confused and lost, I've tried to read the tutorial online, but I'm not having much luck sorry. Can I please ask for some pointers. I have a ComfilePi HMI (Raspberry Pi) communicating to a Omron R88D-1SN08H-ECT amplifier. Please see the attached project file (which is better for sharing, the project file, or a archive?). This file was simply for testing the motion of the servo before anything else is tested with it. The project simply rotates the servo 1 rotation when called for, but the speed can vary based on user input. Nothing much fancy. As yet, I haven't had any servo movement, no errors on the amplifier display. How do I link the motion FBs to the physical drive? Thank you very much for any help you can offer. I'm sorry if I'm doing something very stupid or basic and getting it wrong. Have a good day. Toby
Last updated: 2023-09-20

Post by open on How to create a stopwatch? CODESYS Forge talk (Post)
Hi @ph0010421, I tried the program the TimeTaken is calculated when stop is triggered. I want the TimeTaken to be continuously calculated and counting when a BOOL variable is true. I tried to program this way: Declaration: PROGRAM PLC_PRG VAR bStartStop: BOOL := FALSE; // Start/Stop button bReset: BOOL := FALSE; // Reset button bRunning: BOOL := FALSE; // Flag indicating whether the stopwatch is running tStartTime: TIME; // Variable to store the start time tElapsedTime: TIME; // Variable to store the elapsed time END_VAR Implementation: // Main program logic IF bReset THEN // Reset button pressed, reset the stopwatch bRunning := FALSE; tElapsedTime := T#0s; ELSIF bStartStop THEN // Start/Stop button pressed, toggle the running state IF bRunning THEN // Stop the stopwatch bRunning := FALSE; ELSE // Start the stopwatch bRunning := TRUE; tStartTime := tElapsedTime; END_IF; END_IF // Update the elapsed time when the stopwatch is running IF bRunning THEN tElapsedTime := tElapsedTime + T#1s; // Adjust the time increment as needed END_IF However counting of the seconds is not accurate. I tried changing the main task cycle time interval to 1000ms. The counting of seconds become slower. (see attached) Please help
Last updated: 2023-12-08

Post by wbj0t on What the right way to update TCP/COM slave device holding registers CODESYS Forge talk (Post)
Hi all :) I have an plc. This plc has option to be as slave device. There are TCP -> Serial Slave Device and COM -> Serial Slave Device. There are 4096 ModBus holding registers with mark "internal modify" for the both devices above. So, COM Slave has 4096 registers and TCP Slave has 4096 registers. And, finally, I have an ARRAY[0..4095] OF WORD. This array glued with COM Slave and TCP slave. Yes, I need plc's opportunity to be communication both TCP and COM ways for the same registers. For example, the next task structure: * TASK_0: 1. pou_READ_Registers 2. pou_0 3. pou_1 4. ... 5. pou_N 6. pou_WRITE_Registers At the first pou I read registers for the other pous, after job we have sort of state of the plc. At the last pou (6) we write modified registers. It is a good scenario: some one wrote registers for the job, after job we save these (modified) registers. But, what if registers wrote between 1 and 6 pou by operator, for example, at the 3 pou -> the last pou 'pou_WRITE' will rewrite this request from operator. What the right way to work with this logic? Thanks you.
Last updated: 2024-07-01

Post by jy77812 on MC_MoveCircularAbsolute Using Help CODESYS Forge talk (Post)
Dear People I’m trying to draw a circle using MC_MoveCircularAbsolute, but I keep encountering an error. The error message is SMC_CP_CIRCLE_CENTER_NOT_ON_BISECTOR. What I’m trying to do is simply draw a circle with a diameter of 20, starting from the point X=0, Y=0. I’ve set CircMode to center. It seems like a simple task, but the error keeps occurring, and it’s giving me a headache. I’d appreciate your help. I’ve also attached the program, so please provide any advice you can. I want to use the mode as the center. I've tried changing multiple coordinates and it won't run. Please help. sample stCirculAuxPoint.c.X := 20; stCirculAuxPoint.c.Y := 10; stCirculEndPoint.c.X := 20; stCirculEndPoint.c.Y := 30; fbMoveCircularAbsolute( AxisGroup := AxisGroup, Execute := xGroupCirculEx, CircMode := SMC_CIRC_MODE.CENTER, AuxPoint := stCirculAuxPoint, EndPoint := stCirculEndPoint, PathChoice := 0, Velocity := 50, Acceleration := 50, Deceleration := 50, Jerk := 50, CoordSystem := SMC_COORD_SYSTEM.MCS, BufferMode := 0, TransitionMode := 0, TransitionParameter := , OrientationMode := , VelFactor := , AccFactor := , JerkFactor := , TorqueFactor := , Name := , Done => , Busy => , Active => , CommandAborted => , CommandAccepted => , Error => , ErrorID => , MovementId => );
Last updated: 2025-06-04

Post by mdetrana on VPLCs Tab 'Grey-ed Out', Cannot Create VPLC CODESYS Forge talk (Post)
When evaluating Codesys functionality, I found that the VPLC tab under Deploy Control SL > Operation > VPLCs is 'grey-ed out', see attached image. I'm trying to evaluate how my infrastructure will interact with Codesys on a Raspberry Pi 4, so I'm trying to demo running it before purchasing licenses. I was going through the Codesys tutorial here, and it never shows the tab as grey, so I do not know how to proceed. Let me know if I can get any additional information that can help. This could be related to an Info message that's sent when connecting- [INFORMATION] Connected successfully! [INFORMATION] Successfully connected to target (<ip_address>) [INFORMATION] No supported container engine found on device. You have to install a supported container engine to use Virtual Control. Please contact the Administrator of the device. [INFORMATION] Finished reading device information</ip_address> I'm not exactly sure what I would need to do to install a 'supported container engine'.
Last updated: 2025-10-09

Post by lzml on HTML5 visualization controls disabled on CODESYS Control for Linux SL - overlay not supported? CODESYS Forge talk (Post)
Thanks for the suggestion - I updated everything via the CODESYS Installer and restarted, but I'm still hitting the same error. What I did - Updated via Tools > CODESYS Installer - Visualization system libraries (VisuElems, VisuElemsAlarm, VisuInputs, VisuNativeControl, etc.): 4.7.0.0 -> 4.10.0.0 - CODESYS Control for Linux SL: 4.15.0.0 -> 4.21.0.0 (based on CODESYS SDK 3.5.22.20) - Restarted CODESYS Development System Checked project environment (Project > Project Environment) after restart - Compiler version: 3.5.22.0 - Library versions: all up to date - Visualization Profile: CODESYS Visualization 4.10.0.0 - SoftMotion version: 4.20.2.0 Result: compiling with Device = CODESYS Control for Linux SL still fails with the same error: "Overlay is not supported for your target visualization device." The custom HTML5 control is still disabled/missing from the Toolbox with this Device selected (same as before), and still appears normally when I switch the Device to a Windows target. Is there anything else specific I should check (e.g. a setting on the Device description itself, a different SL package/edition, or is WebVisu overlay for custom HTML5 controls simply not implemented yet for CODESYS Control for Linux SL regardless of package version)? Any pointer appreciated.
Last updated: 2026-08-05

Post by janderson on OPC UA Server limitations, large array crashes runtime CODESYS Forge talk (Post)
What are the limitations of the OPC UA Server? I am trying to get data off my PLC that is acquired at high rates (~50k samples/s) so I am storing them in arrays and trying to get the arrays off the PLC. When I attempt to read a ~200k element array through OPC UA the server and runtime crashes (requiring tools -> update linux arm64 -> start runtime). Is there a better way to get highspeed data off? The ACDatalog library seems a bit irritating to use so I would prefer to go through OPC UA.
Last updated: 2023-08-23

Post by muhq on Profinet connection to Siemens CP343-1 Lean (IO-Device/Slave) CODESYS Forge talk (Post)
Hi, I am quite new to Codesys and I try to do a Profinet connection to an Siemens PLC (315-2DP) with CP343-1 Lean Modul. I already configured the Siemens PLC, exported the GSDML. Then I added a new project in Codesys, added following moduls: - Ethernet - PN_Controller - Imported Profinet Device via GSDML importer When I start the programm everything looks fine but I always get the message "Stopped Profinet" and no data is available This is only for a small test. Therefore I start to do that on a Windows 10 with Development System. Later I will try to realize this on Raspberry. Ethernet Adapter is configured (192.168.1.1 / 24) Firewall deactivated WinPCap is installed S7-Station seems to be found ('fuadazenzitest') Can please somebody help me?
Last updated: 2023-08-26

Post by jari-koivuluoma on JSON_Utilities_SL JSONFileWriter error NULL_POINTER CODESYS Forge talk (Post)
FB jsonFileWriter gives a NULL_POINTER error, why? JSONByteArrayWriter works fine so the JSONData FB should be fine. The device is CODESYS Control Win V3 x64 in simulation mode. Codesys version is V3.5 SP16 Patch 5 JSON_Utilities_SL version is 1.3.0.0 Src: ST_TestStruct1a; TXT: WSTRING(10000); MakeJSON : BOOL := TRUE; SrcJSONData: JSON.JSONData; jsonFileWriter : JSON.JSONFileWriter; IF MakeJSON THEN MakeJSON := FALSE; // Struct data to JSONData FB F_TestStructToJSON(ADR(Src),ADR(SrcJSONData)); // Writing to file jsonFileWriter( xExecute := TRUE, sFileName := 'c:\JSONTEST\JSON.txt', eEncoding := JSON.Encoding.UTF_16, xAsyncMode := TRUE, jsonData := SrcJSONData ); // Waiting to finish WHILE jsonFileWriter.xBusy DO ; END_WHILE // To text jsonArrayWriter( xExecute := TRUE, pwData := ADR(TXT), udiSize := SIZEOF(TXT), jsonData := SrcJSONData, xAsyncMode := FALSE, ); END_IF
Last updated: 2023-09-08

Post by manuknecht on Specify Input Configuration "OnDialogClosed" Action to only react to certain Dialogs CODESYS Forge talk (Post)
I have a project with several buttons and dialogs. Most of the dialogs are opened using the Open Dialog action of the Input configuration of the buttons. Some dialogs are openend using the FbOpenDialogExtended FB of the Visu Utils library and the FbOpenDialogExtended FB is called in the Execute ST-Code action. I am also using the FileOpenSave dialog from Visu Dialogs which requires an OnDialogClosed action to read out. I realized that the OnDialogClosed action which is meant for the FileOpenSave dialog also triggers if a dialog is closed, which was previously openend using the FbOpenDialogExtended FB. Is there a way to detect which dialog was closed last and specify to which dialogs the OnDialogClosed action reacts?
Last updated: 2023-09-20

Post by ellcap on Did a library update and now can't open project CODESYS Forge talk (Post)
EDIT: Title was a mistake. Should say now I can't compile / download project. Codesys V3.5SP19 Patch 2. Updated the libraries/packages using the Codesys Installer. I'm hit with this error ------ Build started: Application: ------- Typify code... [ERROR] iecvaraccess, 4.4.0.0 (system): IecVarAccess: C0086: No definition found for interface 'IIecVarAccess17' [ERROR] iecvaraccess, 4.4.0.0 (system): IecVarAccess: C0077: Unknown type: 'IIecVarAccess17' [ERROR] iecvaraccess, 4.4.0.0 (system): Initialize [IecVarAccess]: C0032: Cannot convert type 'IECVARACCESS(iecvaraccess, 4.4.0.0 (system))' to type 'IIecVarAccess17' [ERROR] iecvaraccess, 4.4.0.0 (system): QueryInterface [IecVarAccess]: C0231: Expression of type 'BOOL' expected in this place [ERROR] iecvaraccess, 4.4.0.0 (system): QueryInterface [IecVarAccess]: C0077: Unknown type: 'ITFID_IIecVarAccess17' [ERROR] iecvaraccess, 4.4.0.0 (system): QueryInterface [IecVarAccess]: C0046: Identifier 'ITFID_IIecVarAccess17' not defined Compile complete -- 6 errors, 101 warnings Build complete -- 6 errors, 101 warnings : No download possible
Last updated: 2023-09-25

Post by damian177 on Codesys V3.5 + Pixtend v1.3 + RaspberryPi CODESYS Forge talk (Post)
Hi, I use Pixtend v1.3 with my RaspberryPi with Codesys V3.5 SP15 Patch1. Actually in my project I used two packages: - CODESYS Contro for Raspberry PI 3.5.15.10 - PiXtend for CODESYS 1.3.8.0 Now I would like to extend my project about the IIot Libraries SL package, I installed them. Next I added SMS_Service_SL 1.0.0.8 version library and I have problem with compile my project because I get error: [ERROR] PiXtend_DemoProject_q: Library Manager [Device: PLC Logic: Application]: Could not open library '#CAADTUtil'. (Reason: The placeholder library 'CAADTUtil' could not be resolved.) Any have idea what can I do to properly add SMS library to my project?
Last updated: 2023-09-26

Post by derpaul on PFC200 Update to 4.9.0.0 - No Connection CODESYS Forge talk (Post)
Hallo Today I decided to perform an Update on my PFC200 but after the Update the Device was not reachable anymore. I tried reseting to factory reset. Software reset and so on, but nothing helps... In my Router I can see it, I cann SSH into the PFC200 but it is not reachable. Then I try to go back to 4.8.0.0 But now I get this error: [INFORMATION] Befehl SSH auf root@192.168.1.17 ausführen: Laufzeitsystem stoppen [FEHLER] Fehlerausgabe: /etc/init.d/codesyscontrol: line 34: /opt/codesys/scripts/init-functions: No such file or directory [INFORMATION] Standardausgabe: /etc/init.d/codesyscontrol: line 34: /opt/codesys/scripts/init-functions: No such file or directory Please help, I can't get this thing working... Regards
Last updated: 2023-09-27

Post by derpaul on PFC200 Update to 4.9.0.0 - No Connection CODESYS Forge talk (Post)
Hallo Today I decided to perform an Update on my PFC200 but after the Update the Device was not reachable anymore. I tried reseting to factory reset. Software reset and so on, but nothing helps... In my Router I can see it, I cann SSH into the PFC200 but it is not reachable. Then I try to go back to 4.8.0.0 But now I get this error: [INFORMATION] Befehl SSH auf root@192.168.1.17 ausführen: Laufzeitsystem stoppen [FEHLER] Fehlerausgabe: /etc/init.d/codesyscontrol: line 34: /opt/codesys/scripts/init-functions: No such file or directory [INFORMATION] Standardausgabe: /etc/init.d/codesyscontrol: line 34: /opt/codesys/scripts/init-functions: No such file or directory Please help, I can't get this thing working... Regards
Last updated: 2023-09-27

Post by ofey on Modbus TCP communication CODESYS Forge talk (Post)
Hi! I tried setting up the PLC I'm working with (Beijer GN-9373) to connect to a modbus master running on a laptop. I have an ethernet connection (via USB-C to ethernet) between the laptop and the controller. I have tried following tutorial on how to set this up. I have added an ethernet device with the IP-address of the PLC. Further I added a ModbusTCP_Slave_Device with default settings. I get the error "Failed to open TCP Port: 1" when I try to go online with the PLC. Earlier I tested the exact same set up with the soft PLC from codesys. I can then read/write values correctly with the Modbus master i have running on the laptop. Hope anybody can help me with this, thanks in advance!
Last updated: 2023-10-06

Post by pascaljt on Function block for Ethernet/IP CODESYS Forge talk (Post)
Hello, I program a function for an Ethernet/IP controller. I made a structure with input and output corresponding with the map of my controller for the function block. My problem is that I don't know how to do the link between the controller and my PLC (CC 100 from Wago). The addresses declare in Codesys are illogic, The first addresses are 12 and 13 then 7 then 4. How to do corresponding the addresses of the controller and the input / output structure ? IP adress ? Does I must create the all variables of controller with the controller adresses to use with the function block ? Thanks for your help. (I hope I'm clear, I'm not english)
Last updated: 2023-10-26

Post by bernd on Version 3.5.19.40 probleme bei FUN mit _to_ im Name CODESYS Forge talk (Post)
Hallo, ich habe von Version 3.5.19.0 auf 3.5.19.40 hochgerüstet, jetzt bekomme ich bei allen FUNs die "to" im Namen haben einen Fehlermeldung. Oft in der OSCAT.LIB verwendet. Gleiche Meldung wenn ich einen FUN neu anlege. Sobald ich das to weglasse z.b. nur "t" ist der Fehler weg. Programm ist unverändert. Fehlermeldung: Typ.... wird nicht unterstützt. Hat jemand das gleiche Problem? Bzw. wo liegt das Problem? Bzw. nutzt jemand das SP4 und bei ihm kommt der Fehler nicht? Läuft bei mir auf Rasperry. Beispiel: DT_TO_SDT -> Fehlermeldung Typ DT_TO_SDT wird nicht unterstützt. DT_T_SDT -> Übersetzung Fehlerfrei
Last updated: 2023-11-09

Post by ewi04 on Recipe Manager - RecipeManCommands, load & write wrong values, Bug? CODESYS Forge talk (Post)
Hallo, I have a strange problem with the recipe manager. ISSUE: When using RecipeManCommands not all values are loaded correctly. Saving a recipe with CreateRecipe(), ReadAndSaveRecipe() or ReadAndSaveRecipeAs() works without any problems. BUT: LoadRecipe(), WriteRecipe() or LoadFromAndWriteRecipe() do not load the data correctly. It is Interesting that we have a different error pattern with LoadRecipe() than with WriteRecipe() or LoadFromAndWriteRecipe(). LoadRecipe() does not load all data and WriteRecipe() or LoadFromAndWriteRecipe() overwrites some data or assigns it incorrectly. And it is also strange that LoadRecipe() writes the values to the PLC. Normally it doesn’t do it. It makes no difference whether the memory type is textual or binary. I have an object consisting of STRUCTs which is inserted in the recipe definition. Environment: Codesys V3.5 SP19 Patch 4 (64Bit), Recipe Management 4.2.0.0 *Add a project (reduced to the problem)
Last updated: 2023-11-15

Post by appling on License status of Linux 64Bit runtime via CLI CODESYS Forge talk (Post)
Hi, I have a Linux 64Bit system with a Codesys application running on it. It stops after 2hours and a few minutes, which makes me think something is wrong with the installed license. (in my last timing it stopped after 2h4min, on the codesys website it is stated that runtimes without a license stop after 2h) I installed the license via a USB license dongle that I activated on my workstation with the Codesys IDE a while ago. Now the system is shipped at not accessible physically, only remotely via SSH. So is there a way to check the status of the License of the Codesys runtime when it is running on the system? Running the codesyscontrol script with "status" just tells me that it is running, but does not provide any license information. Best regards
Last updated: 2023-12-04

Post by dkugler on Management of a PLC network from a remote station CODESYS Forge talk (Post)
I would figure out, how to create a simple html webpage with 2 frames. One frame with buttons to select the plc. A second frame with hyperlink to the webvisu of the plc ("XXX.XXX.XXX.XXX:8080/webvisu.htm"). Selecting other PLC Button has to change the hyperlink in 2. frame. Costs only some time to figure out :-) Or setup a raspberry Pi with small visualization. Set up a button for each plc and add one browser element. Each button writes the URL of the depending plc to the URL setting of the browserelement. Costs 55€ for runtime licence and a Raspberry Pi.
Last updated: 2023-12-04