Search talk: array conversion to string

 
<< < 1 .. 19 20 21 22 23 .. 180 > >> (Page 21 of 180)

Bug found? Weird behaviour of Combobox (Array and Integer) in CodeSys 3.5SP16 Patch 2 (64bit) Visu CODESYS Forge talk (Thread)
Bug found? Weird behaviour of Combobox (Array and Integer) in CodeSys 3.5SP16 Patch 2 (64bit) Visu
Last updated: 2021-11-02

[SOLVED] Install ESI file: Index was outside the bounds of the array CODESYS Forge talk (Thread)
[SOLVED] Install ESI file: Index was outside the bounds of the array
Last updated: 2017-12-15

how use / convert I/O name or address from array (of strings or other) CODESYS Forge talk (Thread)
how use / convert I/O name or address from array (of strings or other)
Last updated: 2023-01-05

an element of "Array of BOOL" in SFC Action name CODESYS Forge talk (Thread)
an element of "Array of BOOL" in SFC Action name
Last updated: 2008-05-05

Table Control on an array using a constant for its size. CODESYS Forge talk (Thread)
Table Control on an array using a constant for its size.
Last updated: 2016-01-08

BUG: Why does I get garbage values when I use CONCAT and Array with CAA File? CODESYS Forge talk (Thread)
BUG: Why does I get garbage values when I use CONCAT and Array with CAA File?
Last updated: 2019-07-04

Fehler C0178 Externer Zugriff auf VAR_IN_OUT-Parameter "Array" von einem FB CODESYS Forge talk (Thread)
Fehler C0178 Externer Zugriff auf VAR_IN_OUT-Parameter "Array" von einem FB
Last updated: 2023-08-01

Function block with an array of unknown size as a VAR_IN_OUT CODESYS Forge talk (Thread)
Function block with an array of unknown size as a VAR_IN_OUT
Last updated: 2017-03-07

How I should define a huge size byte array in CoDeSys V3? CODESYS Forge talk (Thread)
How I should define a huge size byte array in CoDeSys V3?
Last updated: 2013-08-30

How can i read data from a file into an array? CODESYS Forge talk (Thread)
How can i read data from a file into an array?
Last updated: 2021-08-09

Post by alimans on Hex string CODESYS Forge talk (Post)
Hi kdkwhite, for Word you still can use suggested code by using a union structure and crack down your Word to two byte as bellow: TYPE CrackWordToByte : UNION InWord : WORD; OutBytes : ARRAY [0..1] OF BYTE; END_UNION END_TYPE then define your variable as this type: udInput : CrackWordToByte; now assign your Word variable input to InWord and send OutBytes[x] to the mentioned method: udInput.InWord := WordVariableInput; Input := udInput.OutBytes[x]; Regarding your question about the code: actually 48 is ascii code of "0" and while 65 is the ascii code of "A" so in above code 55 + 10 would be 65.
Last updated: 2023-09-20

Post by sumit on Not able to see input data coming from eip adapter on codesys CODESYS Forge talk (Post)
dhumphries, I changed the datatype this time from BYTE to USINT (because that's what my adapter is sending: array of uint8_t). The text "New Help String" you saw in previous screenshots is just the description of the input/s (it can be anything). I also looked into the logs (see attached) for that ! sign next to the device, I found that connection is being timeout. I tried some suggestions from online such as increase the RPI but still got connection timeout issue, also by changing the datatype, I still don't see incoming data from the adapter, although its visible on wireshark. thanks,
Last updated: 2024-03-07

Post by timvh on FB string and naming CODESYS Forge talk (Post)
I see, you want to initialize the FB. To be able to initialise it like you described, you need to add the FB_Init method to your FB. (right click on the FB, select add object --> method). Then press the arrow down, to select the FB_Init (overwrite default implementation). In the VAR_INPUT section of this method, add the variable --> Tag : STRING; Then in the code section of this method add: THIS^.Tag := Tag; // copy initial value to local variable in FB Search Google if you want to know more about FB_Init. PS, reflection + instance path, is also an option if you want to get the full name of the instance (path) of the Function Block. See: https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_pragma_attribute_instance_path.html
Last updated: 2024-09-30

Post by captaincookie on increase default string length in queue CODESYS Forge talk (Post)
Hello, I'm using Codesys V3.5 SP18 Patch 4. In the ElementCollectionExample Project from Codesys, I test the SimpleQueueExample in a Control Win V3 x64 environment. I try to add a string of 95 characters length to a queue. The default length of strings is defined as 80 characters. In the initialization of a string variable, it is possible to increase the length by the definition of e.g. STRING(1000). But when I write the string defined like this to the queue, only 80 characters are written to it and the rest is missing. I think the default length is still set in the queue definition, so it is necessary to change this, isn't it? Is there any option to increase the default length of strings in the queue? Attached you can find the used project. Thanks in advance. If any information are missing or my description unclear please let me know.
Last updated: 2023-10-05

Post by janderson on OPC UA Server limitations, large array crashes runtime CODESYS Forge talk (Post)
when using an array of structs, the runtime crashes. but when using an array of LREALS, it'll do 100k at least
Last updated: 2023-08-23

Post by timvh on Array of Program CODESYS Forge talk (Post)
You cannot create an array of Programs. Create a Function Block for this purpose instead of a program. You can create an array of FB instances and call each instance in a loop.
Last updated: 2024-09-03

Post by mxj262 on FB having single input but initialized with Array CODESYS Forge talk (Post)
I am adding elements of an ARRAY using pointer to access each element inside a FOR loop and the FOR loop does not stop! What is the right way to use pointers in such case?? I have another loop that is not using pointer and it stops but the loop using pointer keep on adding. METHOD FB_Init: BOOL VAR_INPUT bInitRetains: BOOL; // TRUE: the retain variables are initialized (reset warm / reset cold) bInCopyCode: BOOL; // TRUE: the instance will be copied to the copy code afterward (online change) END_VAR VAR_IN_OUT // basically REFERENCE TO window_buffer: ARRAY [*] OF INT; // array of any size END_VAR THIS^.windowPtr := ADR(window_buffer[0]); THIS^.windowSize := UPPER_BOUND(window_buffer, 1) - LOWER_BOUND(window_buffer, 1) + 1; FUNCTION_BLOCK FB500 VAR_INPUT END_VAR VAR_OUTPUT END_VAR VAR windowPtr: POINTER TO INT; windowSize: DINT; currentIndex: UINT; element1:INT; element2:INT; i:INT; j:INT; sum:DINT:=0; END_VAR element1:=windowPtr[0]; // read the first element of the Array dynamic memorry element2:=windowPtr[1]; FOR i:=0 TO (TO_INT(windowSize-1)) BY 1 DO // this loop does not stop Sum:=sum + windowPtr[i]; END_FOR FOR j:=0 TO 5 BY 1 DO // this loop stops j:=j+1; END_FOR https://ibb.co/k3DhkZT
Last updated: 2024-05-06

Post by thedertom on Help with DynamicTextGetTextW CODESYS Forge talk (Post)
Hi I try to get korean texts out of a textlist. For that I want to use DynamicTextGetTextW, but I am a little confused how it is supposed to work. The function returns POINTER TO STRING, but how do I get WSTRING? I succesfully used DynamicTextGetText with classical Strings. Thanks in advance!
Last updated: 2024-09-02

Post by struccc on HTML5 Controls - string(>80) values CODESYS Forge talk (Post)
Dear all, does anyone have experience with HTML5 controls recently? CODESYS 3.5.20.30 / Visualization 4.6.0.0 I'd like to create a simple lightweight text editor, with proper multiline handling, cut & paste, scrolling, etc. And it seems to work fine, just have problems with strings longer than 80 bytes.... Declaring a variable sText1 : STRING(8000) and referencing it in the HTML5 Controls corresponding value property works perfectly one way: the code receive the data as a string (See log1)... (Note TypeID 1000...) Also sending back the data (seems to work (See log2) except it doesn't change the value of the bound variable. Probably the issue is with using SendSimpleValue method... Naturally, I could do a workaround, but maybe there is a more standard way to implement this... Please let me know if you have any suggestions.
Last updated: 2024-10-23

Post by shawn-plc on Return value from a tag given a string literal CODESYS Forge talk (Post)
Good afternoon everyone, I am looking for a way to return a value given a string tag path. I put together a pseudo-example to illustrate my use-case and was wondering if anyone in this forum can help. The function fnValueFromTagPath is the function I am looking to either create or use from existing library. I would greatly appreciate it. Please see the attachment for additional detail. -Shawn
Last updated: 2024-08-13

Post by dhumphries on Not able to see input data coming from eip adapter on codesys CODESYS Forge talk (Post)
The green icon with an ! next to the device is concerning. Is the data type correct for the input, you are using a byte input but the description says string. Is there anything useful in the status tab?
Last updated: 2024-03-06

Post by installwhat on How to access to variable value through symbolic string name CODESYS Forge talk (Post)
Maybe your question makes sense but I don't see it. Maybe you should rephrase and add a lot of detail
Last updated: 2024-06-13

Post by otbeka on CmpCrypto CryptoGenerateHash Not Outputting CODESYS Forge talk (Post)
Unfortunately I noticed that, and tried: * using CryptoGeteAlgorithmByID within the function call * inputting the raw byte pointer as a testByte * instantiating the _hHash handle within the function body * using a different cryptoID or the raw DINT values from the RtsCryptoID DUT ... to no avail. The pReturn value is also set to 0, which would indicate that it is OK, right? This is odd given that the function is the same within the CryptoDemo example project here, just with a newer version. Is it possible that there is something wrong with the way my bytestring is being set up? I use the following DUTs here: TYPE MESSAGE : STRING(255); END_TYPE TYPE HASH_CODE : ARRAY[0..19] OF BYTE; END_TYPE
Last updated: 2024-09-06

Post by macros8 on Translation - How to get text as reference in Frames translated? CODESYS Forge talk (Post)
Hi all, I need a help. I want to create Frame where some parameters are done via reference input to this frame. What I have realized that if I use for Label/Caption etc. string variable (%s) it is not included in translation list. This is a quite a big deal and I did not find way how to add text to the list manually. Would you give me a hint how to proceed? I hope there is a way (workaround) how to do it. Thanks a lot. M.
Last updated: 2023-12-01

Post by talhaali on Active alarm access in ST CODESYS Forge talk (Post)
Hi, I am trying to access active alarms in code(As alarm count variable updates only when we go to to alarm table frame in visualization). I wrote following code but it is not working: VAR iCountActiveAlarms : INT; parritfActiveAlarms : POINTER TO ARRAY[0..0] OF IAlarm; itfAlarmManagerClientAll : IAlarmManagerClient; END_VAR AlarmManager.g_AlarmHandler.GetActiveAlarms( itfAlarmManagerClient :=itfAlarmManagerClientAll, iCountActiveAlarms => iCountActiveAlarms, parritfActiveAlarms => parritfActiveAlarms); The Value is always 0. Please help.
Last updated: 2024-06-06

<< < 1 .. 19 20 21 22 23 .. 180 > >> (Page 21 of 180)

Showing results of 4498