Post by fontrap on cmDongle Raspberry Pi issue CODESYS Forge talk (Post)
Good morning @eschwellinger, After some research I found out that the problem is the preinstalled CodeMeter on Raspberry Pi. As I mentioned the CodeMeter was installed on the Raspberry because I use a license from other vendor that needs the CodeMeter to be installed. The problem is that when I uninstall the CodeMeter from Raspberry I am able to detect the dongle from CODESYS and everything works as it should be but now the other product can not detect its own license. When I reinstall the CodeMeter I am back to the initial problem. Is there a way to overcome this conflict through CODESYS?
Last updated: 2024-04-24

Post by eschwellinger on Problem with Licenced Software Metrics CODESYS Forge talk (Post)
check in the CODESYS installer which version is used update to latest
Last updated: 2024-04-24

Post by eschwellinger on Can't connect to Device Raspberry Pi 4 from CODESYS IDE V3.5 SP19 CODESYS Forge talk (Post)
with latest version?
Last updated: 2024-04-26

Post by eschwellinger on Login problem with FileTransfer on Raspberry Pi 5 CODESYS Forge talk (Post)
maybe to add [CmpWebServerHandlerV3] CallVisuServicesDirectly=0 would help
Last updated: 2024-04-28

Post by valenting on Problem with Licenced Software Metrics CODESYS Forge talk (Post)
Update : I updated my project's compiler version to the latest and it finally works
Last updated: 2024-04-29

Post by eschwellinger on IoDrvModbusTCP_Diag not defined when using MODBUS CODESYS Forge talk (Post)
error need to be solved by CODESYS. hopefully next release
Last updated: 2024-05-01

Post by alex2 on Codesys SVN CODESYS Forge talk (Post)
Are you sure about that? The 1.1.0.0 seems to be for V3.5.17.0 or higher. For the SP18, couldnt i take the 1.2.1.0?
Last updated: 2024-05-02

Post by aris-k on Pack TWO INT variable to one DINT variable CODESYS Forge talk (Post)
You can try this setup: DINTVar := SHL(INT_TO_DINT (Low_Word_INT_Var),16) + INT_TO_DINT(High_Word_INT_Var);
Last updated: 2024-05-07

Post by jonasz on Discontinuity of A/B/C axis movement. CODESYS Forge talk (Post)
Hi, My problem was related to the behavior of the modulo axis, but maybe you will find something useful from what I write. The solution lies in path processing. Codesys offers a G-code analysis tool. Insert a CNC object into the project. The CNC settings object will be added automatically. By inserting appropriate processing modules into the CNC settings object and parameterizing them, you can test the behavior of the axis. When the effect is satisfactory, remember to add the module from CNC settings in the correct order in the processing path. Each CNC machine case is different. You need to spend some time to get your design tailored like an Armani suit. Good luck.
Last updated: 2024-05-09

Post by eschwellinger on Recipe Manager - Not Creating Recipe Files CODESYS Forge talk (Post)
due security reasons this folder need to be in PlcLogic area.
Last updated: 2024-05-17

Post by culius on JSON CODESYS Forge talk (Post)
Sorry that I haven't replyed to youranwser in so long time. Thank you for explaining the issue. Now everything works without a problem!
Last updated: 2024-05-21

Post by eschwellinger on Licensing info not available. CODESYS Forge talk (Post)
we recommend to do it with the official virtual plc version..will send a version.
Last updated: 2024-05-23

Post by fpawlak on KNX SL on stock PFC200 firmware CODESYS Forge talk (Post)
Hi All. Is it possible to use CODESYS KNX SL on stock Wago firmware (Codesys version, not e!Cockpit). I have Wago 750-8212 with firmware 0.4.04.03(26). When I tried to run 'KNX SL' or even 'Device Reader', I have got [FATAL ERROR] Unresolved reference: 'CODEMGETCONTENTBYFIRMCODE3' [FATAL ERROR] Unresolved reference: 'CODEMGETCONTENTBYFIRMCODE2' [FATAL ERROR] Unresolved reference: 'CODEMGETCONTENTBYFIRMCODE2' What probbalby means that there is no running CodeMeter component on PLC. I have checked /etc/codesys3.d/CODESYSControl.cfg [CmpWebServer] WebServerPortNr=58080 [CmpSecureChannel] CertificateHash=86ccf31839a098ee32067179e26600f1bd6b36f8 [CmpUserMgr] AsymmetricAuthKey=a9d38381e75bbf1bbfc8749e97f536f68238a2ce So the question is if I can somehow add Codemeter to stock firmware? Or should I switched to CODDESYS Control for PFC200 SL or application-base runtime licence?
Last updated: 2024-05-23

Post by eschwellinger on New License not working. CODESYS Forge talk (Post)
please use 'my question' in the CODESYS Store to ask for support
Last updated: 2024-05-24

Post by ndzied2 on Rounding error in simple addition CODESYS Forge talk (Post)
Ignore, was duplicate post. Can't find a way to delete it.
Last updated: 2024-05-24

Post by ppix on MQTT PLC Chat: CODESYS Forge talk (Post)
Did you ever find a solution to this? I am having the same issue but using TLS connection.
Last updated: 2024-05-26

Post by timvh on Display minutes as hours & minutes CODESYS Forge talk (Post)
You could use the Modulo function to get the minute part from the total minutes: Minutes := TotalMinutes MOD 60;
Last updated: 2024-05-27

Post by timvh on Sensor not set CODESYS Forge talk (Post)
Your function block instance is not called, so the code is not executed to set the light on when the button is pressed.
Last updated: 2024-05-27

Post by sigurdrb on send appliaction files to wago plc (codesys 3.5) via ssh CODESYS Forge talk (Post)
Okey, I will try this out. Thank you for your answer!
Last updated: 2024-05-30

Post by kislov on Signature verification faited fro the following package CODESYS Forge talk (Post)
Try to use newer version of CODESYS Installer: https://store.codesys.com/de/codesys-installer.html
Last updated: 2024-06-11

Post by jens on Modbus tcp - channel CODESYS Forge talk (Post)
Help wanted This is the first time i'm doing a Modbus Tcp project. I have some VLT with a extension module MCA-122. i'm currently unable to write to the VLT slave, but i can read from status word parameter=1603 and address := 16029 where the address is calculated from parameter is ((id x 10)-1). in the manual the functions that are supported are 3 hex, 6 hex, 10 hex, b hex and 11 hex. read holdin registers, write single register, write multiple registers, get comm. event counter, report slave id. i'm only using the Modbus Slave Channel is this wrong when trying to write to the vlt ?
Last updated: 2024-06-13

Post by eschwellinger on CODESYS control on RPi starts, shortly runs, then exits CODESYS Forge talk (Post)
if you use Bookworm uodate to 4.11.0.0 version please.
Last updated: 2024-06-13

Post by bruno-roth on Codesys access to DICTIONARY OBJECTS of ethercat (CoE ) Servo Drive CODESYS Forge talk (Post)
You could use the FBs ETC_CO_SdoWrite and ETC_CO_SdoRead
Last updated: 2024-06-19

Post by eschwellinger on No Visu on RasPi CODESYS Forge talk (Post)
..on 4.12.0.0 release there it will be possible to deploy RemoteTargetvisu which is what you expect now. (next week)
Last updated: 2024-06-20

Post by kuegerls on SysProcessExecuteCommand2 and CANopen Device CODESYS Forge talk (Post)
I am now executing the process in a separate task with lower priority, but unfortunately, the connection to the master is still interrupted.
Last updated: 2024-06-21