Post by dmb-fan on Hilscher cards CoDeSys Control RTE CODESYS Forge talk (Post)
Hi! I'm currently trying to make my way through this jungle... Hilscher CIFX 50E PCIe cards: DP Master + CANopen Master If I want to run these under Control RTE, do I need a master license from Hilscher for each card? Or do they run entirely with CoDeSys drivers and parameterization tools? I can’t find any clear information on this from either manufacturer. Thanks
Last updated: 2026-08-06

Post by jonasz on Deploy LicenseServer for Linux SL CODESYS Forge talk (Post)
So here's how: I manually installed the following packages: codemeter-lite_8.30.6885.501_amd64.deb codesyslicenseserver_licenseserver_4.18.0.0_all.deb codesyswbmbase_wbmbase_4.18.0.0_all.deb codesyswbmlicensing_wbmlicensing_4.18.0.0_all.deb Of course, the license server appeared immediately. Trying to install it again using Install in the Deploy tab, the same error appears. Of course, the information that such a server is already installed is also there. Configuring PLC, S_PLC, EDGE, and SAFE_TIMER_PROVIDER went smoothly, and basically everything works. I wrote a simple program for S_PLC. I'm loading the programs into PLC and S_PLC. When loading the program into S_PLC, a message appears stating that there is no connection to the S_PLC controller. Timeout error. Restart the controller, attempt to load, and see the above. After changing the cycle time for S_PLC to 50ms, the problem no longer occurs. My question, besides the difficulty of installation for a new user, is what causes the cycle time for S_PLC to be so long, and how can I fix it?
Last updated: 2025-11-14

Post by timl on Application has invalid license metrics CODESYS Forge talk (Post)
Hallo, ich habe eine Control for Linux SL auf der ich einen TCP Modbus Master anlege, mit dem ich einen Slave auslesen möchte. Das Anlegen funktioniert soweit alles, sobald ich beim ModbusTCPSlaveE/A-Abbild in den Channel eine Variable einfüge, damit ich den Channel auslesen kann, kommt es beim übertragen auf die SPS zu einem Ausnahmefehler. Im Anhang noch eine Bilder der Fehlermeldung und der installierten Lizenzen. CODESYS Version ist V3.5 SP19 Patch 4 Meinem Verständnis nach ist die Modbus Lizenz mit in der Control Standard L inbegriffen und auch in der Lizensierten Softwaremetrik sehe ich keine überschreitung meiner Lizenzbegrenzungen. Daher verstehe ich nicht wieso ich diesen Fehler bekomme und eine auslesung via Modbus nicht möglich ist. Gruß Tim
Last updated: 2024-05-08

Post by mavitia on Application based license problem - Modbus TCP CODESYS Forge talk (Post)
raspberry pi is running ubuntu, so it has the codesys control for linux arm 64 bit, IDE is 3.5.19, both were installed last week from the latest versions online, im currently out of the PC but will upload some evidence ASAP
Last updated: 2023-12-18

Post by mavitia on Issue with TargetVisu on Codesys Control Win CODESYS Forge talk (Post)
anyone else running into the same issue: perform a repair install on the runtime, that should fix it without affecting license.
Last updated: 2024-02-02

Post by valenting on Problem with Licenced Software Metrics CODESYS Forge talk (Post)
Update: it seems that the license is detected by CODESYS on my computer but not detected by the runtime on my device. I'm using Codesys control for raspberry pi in the latest version 4.11.0.0 Is there something to do to correct this ?
Last updated: 2024-04-29

Post by eschwellinger on License Reset Request – CODESYS Control Win V3 Standard L CODESYS Forge talk (Post)
Please write these kind of request to 'my question' in the CODESYS Store. please do not use ticket and softcontainer numbers here.
Last updated: 2025-10-23

Post by jonasz on Deploy LicenseServer for Linux SL CODESYS Forge talk (Post)
Hello, Basically, everything is clear to me. There's still the issue of a TimeProvider for an external device. This may be a stupid question, but I can't find this package. And of course, the question is, can the RPi machine be an external provider? Has anyone tested such a solution?
Last updated: 2025-11-18

Post by eschwellinger on Deploy LicenseServer for Linux SL CODESYS Forge talk (Post)
As I see from your logs I think the Timeprovider is not accurate enough in your case. Things to check - at the moment you run it on the same device? (for tesing purpose ok) I would set 127.0.0.0 as IP and set it not really to Core 0 ( many other stuff is there)
Last updated: 2025-11-20

no synchronization via field bus(Raspberry Sl softmotion) CODESYS Forge talk (Thread)
no synchronization via field bus(Raspberry Sl softmotion)
Last updated: 2018-05-29

Raspberry Pi 4.12.0.0 SL also stops after 15s CODESYS Forge talk (Thread)
Raspberry Pi 4.12.0.0 SL also stops after 15s
Last updated: 2024-07-06

OPC-UA Client connection, Linux SL /Raspberry Pi CODESYS Forge talk (Thread)
OPC-UA Client connection, Linux SL /Raspberry Pi
Last updated: 2024-08-21

OpC UA server on Raspberry Pi 64 SL runtime CODESYS Forge talk (Thread)
OpC UA server on Raspberry Pi 64 SL runtime
Last updated: 2024-12-12

OpC UA server on Raspberry Pi MC SL - Certificate Issue CODESYS Forge talk (Thread)
OpC UA server on Raspberry Pi MC SL - Certificate Issue
Last updated: 2025-05-23

Having trouble using the Web Client SL library CODESYS Forge talk (Thread)
Having trouble using the Web Client SL library
Last updated: 2025-10-07

RaspberrPi 4 Compute Module: Runtime "SL" available? CODESYS Forge talk (Thread)
RaspberrPi 4 Compute Module: Runtime "SL" available?
Last updated: 2021-02-02

Why Codesys Raspberry SL not updated any more like 3.5.9.0? CODESYS Forge talk (Thread)
Why Codesys Raspberry SL not updated any more like 3.5.9.0?
Last updated: 2016-07-07

HMI SL - Runtime shutdown by on screen command CODESYS Forge talk (Thread)
HMI SL - Runtime shutdown by on screen command
Last updated: 2019-08-05

Trace on Raspberry Pi SL - Not a traceable variable CODESYS Forge talk (Thread)
Trace on Raspberry Pi SL - Not a traceable variable
Last updated: 2023-07-20

CNC+Robotics SL on the Raspberry Pi CODESYS Forge talk (Thread)
CNC+Robotics SL on the Raspberry Pi
Last updated: 2016-09-13

Cannot send email using IIoT Libraries SL CODESYS Forge talk (Thread)
Cannot send email using IIoT Libraries SL
Last updated: 2022-09-23

IIoT Libraries SL 1.6.0.0 Statusmeldung Per Mail senden CODESYS Forge talk (Thread)
IIoT Libraries SL 1.6.0.0 Statusmeldung Per Mail senden
Last updated: 2022-05-03

SL Licence installed on the wrong place CODESYS Forge talk (Thread)
SL Licence installed on the wrong place
Last updated: 2020-10-05

PFC100 SL symbol configuration, var access problem CODESYS Forge talk (Thread)
PFC100 SL symbol configuration, var access problem
Last updated: 2023-03-08

Codesys HMI SL on Wago PFC200 sooo slow CODESYS Forge talk (Thread)
Codesys HMI SL on Wago PFC200 sooo slow
Last updated: 2019-11-12

<< < 1 .. 24 25 26 27 28 .. 74 > >> (Page 26 of 74)

Showing results of 1827

Sort by relevance or date