Post by tomast on Siemens V20 Frequenzumrichter ΓΌber Modbus RTU CODESYS Forge talk (Post)
Hi Tim, Have you sorted out your problem because i have also problems with i?
Last updated: 2024-03-21

Post by csanderson on IoDrvModbusTCP_Diag not defined when using MODBUS CODESYS Forge talk (Post)
I am also having this same issue after upgrading to 3.5.20.0. Any help Codesys?
Last updated: 2024-04-17

Post by santana on IoDrvModbusTCP_Diag not defined when using MODBUS CODESYS Forge talk (Post)
I'm having this same issue. I upgraded to 3.5.20.0 from 3.5.19.20. Now I have the precompile errors shown above.
Last updated: 2024-04-17

Post by eschwellinger on IoDrvModbusTCP_Diag not defined when using MODBUS CODESYS Forge talk (Post)
error need to be solved by CODESYS. hopefully next release
Last updated: 2024-05-01

Post by zer0g on Modbus Client Request Not Processed CODESYS Forge talk (Post)
Hi, Thank you for your suggestion but the problem is fixed after I disabled and enabled the network adapter from Windows settings.
Last updated: 2024-05-30

Post by wbj0t on Global variable access by Programms and Modbus Devices (attach device to bus) CODESYS Forge talk (Post)
Hi everyone. I use Raspberry Pi 4, one core codesys SL. I have a question about global variable access via programm when I glued the same variable to MODBUS SERIAL/TCP DEVICE holding register. So, the question: what behavior of this modifying? When I set "Always update variables (in bus cycle)" and set some task as bus for the Device, then in another task I cant change this varible (can, but immediatly the old value setted again). But the same things works with MODBUS SLAVE: again "Always update..." and master attached to some task, then I change variable in another task and all works. I cant set up my variables from retains file at PrepareStart event because of this behavior with MODBUS SERIAL/TCP DEVICE. Thanks, wbj0t.
Last updated: 2024-07-18

Post by shrikantp007 on new to codesys help on modbus with ardunio modbus rtu CODESYS Forge talk (Post)
Hello , I am new to codesys ,working with it for just 15-17 days so ,i think i am able to installed it and configure it ,not i want to use ardunio program (smart dustbin ,college project using motor and Ultrasonic Module HC-SR04 and servo motor). i use ardunio program to write code with chatgpt to work ardunio as a modbus rtu as i dont have ethernet or wifi shild ,i wrote program in ariduno but now don have idea what change i have to make in codesys to comunicate as modbus slave it give error with bus error ,where i can get all errors ? Thanks in advance :)
Last updated: 2024-07-21

Post by mystx on Timeout Error in Modbus Communication with WAGO PFC200 and iEM2050 Meter using 750-652 Module CODESYS Forge talk (Post)
Hello I have the same problem, anyone have some idea?? Regards
Last updated: 2024-07-30

Post by mystx on Timeout Error in Modbus Communication with WAGO PFC200 and iEM2050 Meter using 750-652 Module CODESYS Forge talk (Post)
Hello I have the same problem, anyone have some idea?? Regards
Last updated: 2024-07-30

Post by mystx on Timeout Error in Modbus Communication with WAGO PFC200 and iEM2050 Meter using 750-652 Module CODESYS Forge talk (Post)
Hello I have the same problem, anyone have some idea?? Regards
Last updated: 2024-07-30

Post by thysonfury on OPTO22 Groov Epic PR2 Modbus Comms Dropping out every 2 hours and 4 Mins CODESYS Forge talk (Post)
OPTO22 Codesys Activation license not active.
Last updated: 2024-09-11

Post by winki on Modbus TCP & RTU with Control for Linux SL CODESYS Forge talk (Post)
I made a mistake it is not end0 but eth0. But I have the same error.
Last updated: 2024-10-23

Post by winki on Modbus TCP & RTU with Control for Linux SL CODESYS Forge talk (Post)
No, my vpn is 10.0.0.12. The docker interface is 172.17.0.1.
Last updated: 2024-10-24

Post by winki on Modbus TCP & RTU with Control for Linux SL CODESYS Forge talk (Post)
Your right, much easier with Linux control SL ARM. Everything is working.
Last updated: 2024-10-24

Post by nano on Modbus TCP/IP slave communication errow CODESYS Forge talk (Post)
please tell us the exact error message from diagnostic. U can view it at devicetree in the node-element diagnostic from modbus-configuration. u also can activate the function auto-reconnect in master and increase a little bit the timeout and the repetition to male thw communication a little bit more robust
Last updated: 2024-02-04

Post by ahuckphin on Issues with Modbus Slave with Raspberry Pi CODESYS Forge talk (Post)
codesyscontrol_user.cfg [SysCom] Linux.Devicefile.1 = /dev/ttyUSB0 portnum:=COM.SysCom.SYS_COMPORT1; **parameters are used in the python-script ** method: "rtu" port: "COM8" baudrate: 9600 stopbits: 1 bytesize: 8 parity: 'N' timeout: 1 register address for humidity: 0x000 register address for temperature: 0x001 unit ID: 1 **parameteized in the modbus-master-comport ** see attached files
Last updated: 2024-07-11

Post by nltheves on Raspberry PI4 Serial Port CODESYS Forge talk (Post)
Hi Ricardo. I was having the same problem with Codesys and a Raspberry Pi 2W while using the GPIO uart. Your post helped me a lot. Thanks! But could not understand why MODBUS parity bit makes Codesys MODBUS COM driver stopping to work after first request transmission. Did you see this @eschwellinger ? Regards, Nelson
Last updated: 2024-07-18

Post by oymyakon on Modbus Lockup CODESYS Forge talk (Post)
Hi i have a project where i am communicating with many modbus devices using TCP to serial. This is all working extremely well except when i turn one of the remote devices off. If i leave the auto reconnect on it still doesn't talk to the rmianing devices and if i turn Auto reconnect off it locks up. Any help would be appreciated. Paul.
Last updated: 2024-08-07

Post by oymyakon on Modbus Lockup CODESYS Forge talk (Post)
Hi i have a project where i am communicating with many modbus devices using TCP to serial. This is all working extremely well except when i turn one of the remote devices off. If i leave the auto reconnect on it still doesn't talk to the rmianing devices and if i turn Auto reconnect off it locks up. Any help would be appreciated. Paul.
Last updated: 2024-08-07

Post by squiggleypuff on Can't Add New Version of Modbus TCP Master CODESYS Forge talk (Post)
I'm having a tough time trying to get Modbus working on a Festo CPX-E PLC; it throws these pre-compiler errors as soon as I add in my Modbus TCP Master 3.5.12.30 to my project: I'm confused about the C0046 error, as I have IODrvModbusTCP 4.3.0.0 Library installed. So I thought maybe I needed to use the newest Modbus TCP Master 4.3.0.0, which is in my device repository: However, whenever I go to add this underneath the Ethernet adapter (which is version 4.2.0.0), the only TCP Master version available is the old 3.5.12.30 one, even if I have Display all versions checked.: I even went so far as to delete the old version, but then there were no options to add a Modbus TCP Master under my Ethernet adapter. What needs to be done to use the newest Modbus TCP Master? Or are these pre-compiler errors unrelated and I'm missing something? Any help greatly appreciated.
Last updated: 2024-04-04

Post by fredsta on Unable to load dynamic modules (Download failed: Application=Application) CODESYS Forge talk (Post)
I'll have a look at this, thanks. Do you maybe know why the C-integration doesn't work? I'm just curious because it was still some effort to create all these files. Ending up with a meaningless error feels very unsatisfying to me...
Last updated: 2024-02-19

Post by wbj0t on System libs and I/O Drivers CODESYS Forge talk (Post)
Hi everyone. My question about: where I can learn (read or watch) an info about codesys workflow through the system IO libs? I want to know how to implement I/O drivers by my self. In the system libs I see many interfaces, methods etc... But there is no explanation about them, just names of methods and fields of the FBs. I know about this page: https://forge.codesys.com/drv/io-drivers/doc/Generic/ There is so BIG the device description file and not so clear explaining of the attributes and elements, also some elements or attributes missed at it all. Yes, there are code examples on this page, but, so shortly and, for example, code about Modbus drivers is absent. And even if I try to add the IoDrvFB with lib, I get and error, something like: "failed to load IoDrvFB driver". And what about the book of codesys that written by Gary Pratt? Is there information about system libs and drivers in this book more clearly? Thank you :)
Last updated: 2024-02-02

Post by wildcard on Modbus Client Request Not Processed CODESYS Forge talk (Post)
Hi, does anyone has a solution for this issue. I've the same problem. I've implemented a very simple client based on the Modbus Examples and connected the soft PLC to a Modbus Simulator. PROGRAM ModbusClient VAR initDone : BOOL := FALSE; errorID : ModbusFB.Error; client : ModbusFB.ClientTCP; timeout : UDINT := 500000; replyTimeout : UDINT := 200000; aUINT : ARRAY [0..8] OF UINT; clientRequestReadHoldingRegisters : ModbusFB.ClientRequestReadHoldingRegisters; clientRequestsCnt : UINT := 0; clientRequestsProcessCnt : UINT := 0; ipAddress : ARRAY[0..3] OF BYTE := [10,54,0,72]; END_VAR IF NOT initDone THEN initDone := TRUE; client(aIPaddr:=ipAddress, udiLogOptions:=ModbusFB.LoggingOptions.All); client(xConnect:=TRUE, ); clientRequestReadHoldingRegisters(rClient:=client, udiTimeOut:=timeout, uiUnitId:=1, uiStartItem:=0, uiQuantity:=4, pData:=ADR(aUINT[0]), udiReplyTimeout:=replyTimeout); clientRequestReadHoldingRegisters.xExecute := TRUE; clientRequestsCnt := 0; END_IF clientRequestReadHoldingRegisters(rClient:=client, udiTimeOut:=timeout, uiUnitId:=1, uiStartItem:=0, uiQuantity:=4, pData:=ADR(aUINT[0]), udiReplyTimeout:=replyTimeout, xExecute := TRUE); IF clientRequestReadHoldingRegisters.xError THEN clientRequestsCnt := clientRequestsCnt +1 ; errorID := clientRequestReadHoldingRegisters.eErrorID; END_IF clientRequestReadHoldingRegisters(rClient:=client, udiTimeOut:=timeout, uiUnitId:=1, uiStartItem:=0, uiQuantity:=4, pData:=ADR(aUINT[0]), udiReplyTimeout:=replyTimeout, xExecute := NOT clientRequestReadHoldingRegisters.xExecute); When the system is running I do get the following on the logs: 2024-05-13T10:18:07.443Z: Cmp=MODBUS lib, Class=1, Error=0, Info=0, pszInfo= Client.RequestProcessed ClientRequest,16#0164ADC561A0 unitId=1 fc=ReadHoldingRegisters id=2070 state=Error 2024-05-13T10:18:07.443Z: Cmp=MODBUS lib, Class=1, Error=0, Info=0, pszInfo= ClientRequest,16#0164ADC561A0 unitId=1 fc=ReadHoldingRegisters id=2070 change state Error -> None timestamp=63843421226 2024-05-13T10:18:08.444Z: Cmp=MODBUS lib, Class=1, Error=0, Info=0, pszInfo= ClientRequest,16#0164ADC561A0 unitId=1 fc=ReadHoldingRegisters id=2071 change state None -> Init timestamp=63844421420 2024-05-13T10:18:09.444Z: Cmp=MODBUS lib, Class=1, Error=0, Info=0, pszInfo= ClientRequest,16#0164ADC561A0 unitId=1 fc=ReadHoldingRegisters id=2071 change state Init -> Error timestamp=63845421675 But the errorID is jumping between OK and RequestNotProcessed. Any help is very appreciated which gives me a hint what I'm doing wrong. Thanks
Last updated: 2024-05-13

Post by xnoop on MBTCP Slave configuration CODESYS Forge talk (Post)
Hello, I use Codesys 3.5 SP18 Patch 4 (64 bit) My Codesys project is composed of several dozen of Modbus TCP Slaves. I want to configure each of them by define : - Modbus TCP Slave Configuration : Name, IPAddress, port - Channels - Mapping I can't afford to configure manually and I need to find automatic way What possibilities does the Codesys offer? 1. I know it possible to use python script to create Modbus TCP Master and Slave. But I don't find anyway to create Channels and Mapping through the API 2. I 've tested to set mapping with file.csv on a Modbus Tcp Slave, but no way to import channels definition from file 3. I 've tried to use PLCOpenXml file. For example I 've create a project with an Ethernet device. I've exported it in PlcOpenXml file. After delete the Ethernet device, I've imported the PlcOpenXml file without success. I've tried the same by creating Modbus TCP Slave. Could you help me to find to good way ? Thanks
Last updated: 2024-06-19