Post by gseidel on can not new a cam table in codesys V3.5 SP20
CODESYS Forge
talk
(Post)
Hi liai, I tried it with a fresh CODESYS SP21 Patch 2 installation and SoftMotion 4.18, but cannot reproduce the compile errors. Could you please upload a project archive that has the errors? Then I can have a deeper look. https://dl.codesys.com/s/q4KcbKCcZndg6oR Best regards, Georg
Last updated: 2025-09-24
Post by tvm on Function block method default arguments
CODESYS Forge
talk
(Post)
This works for me in Schneider Machine Expert 2.2, which is based on Codesys 3.5.19. It did not work in Machine Expert 2.1, which was based on Codesys 3.5.16. METHOD PUBLIC Method1 : INT VAR_INPUT TestVar: INT:= 5; END_VAR Method1:= TestVar; PROGRAM SR_Main VAR TestFB: TEST_FB; Var1: INT; END_VAR Var1:= TestFB.Method1();
Last updated: 2024-01-04
Post by kees-b on Enumeration
CODESYS Forge
talk
(Post)
Hello, Can anyone give me advice or tell me what I'm doing "wrong"? I use "enumeration", but via, via (maybe that's the problem?) Similar situation in Codesys 2.3 this worked correctly. Now the BOOL is not found in the ENUM. GVL.g_IPC2AMK.dwDO.DO_AMK_REMOTE_ACTIVE GVL = Global Variabel List g_IPC2AMK = STRUCT dwDO = ENUM DO_AMK_REMOTE_ACTIVE = BOOL
Last updated: 2024-02-06
Post by kees-b on Enumeration
CODESYS Forge
talk
(Post)
Hello, Can anyone give me advice or tell me what I'm doing "wrong"? I use "enumeration", but via, via (maybe that's the problem?) Similar situation in Codesys 2.3 this worked correctly. Now the BOOL is not found in the ENUM. GVL.g_IPC2AMK.dwDO.DO_AMK_REMOTE_ACTIVE GVL = Global Variabel List g_IPC2AMK = STRUCT dwDO = ENUM DO_AMK_REMOTE_ACTIVE = BOOL
Last updated: 2024-02-06
Post by xabier on See only variable
CODESYS Forge
talk
(Post)
I have declarated this variable...When i use the variable I see all...I wan see only the variable not all. For example I declarated in GVL_GLOBAL ==> Torque_Mode When I push enter insert in code all rute..GVL_GLOBAL.Torque_MOde...I want see only torque mode...How is possible resolved this problem?? Thanks XABI
Last updated: 2024-03-14
Post by xabier on What wrong with FB SMC_Interpolator?
CODESYS Forge
talk
(Post)
hi Getdone I have the same problem with you...Could resolved this problem?? Can you move with more speed??... I have cicle time 1 ms and the moment increase speed >5mm/s the FB SMC_Interpolator not fine work....Tell me plese if you resolved this problem Thanks Regards XABI
Last updated: 2024-04-30
Post by michelebianchi on cm4 runtime problem
CODESYS Forge
talk
(Post)
hello i have installed codesys runtime mc sl and sl on a CM4 but after 30 second process exit. have tried those runtime versions: 4.08 4.09 4.10 4.11 i get this message in all situations: ooops... this runtime was built for RASPBERRYPI. Hardware version or firmware version not supported! (-18, 0x00000BB8, 0xFFFFFFFB) os version is raspbian bullseye
Last updated: 2024-05-02
Post by eschwellinger on Recipe Manager - Not Creating Recipe Files
CODESYS Forge
talk
(Post)
With Linux SL and Windows Control Win - with this example https://forge.codesys.com/prj/codesys-example/recipe-manageme/home/Home/ We see in the PLClogic directory the generated recipe files see my screenshot. c:\ProgramData\CODESYS\CODESYSControlWinV3x64\XXXXXXXX\PlcLogic\Hello.RecipeDef.txtrecipe c:\ProgramData\CODESYS\CODESYSControlWinV3x64XXXXXXX\PlcLogic\ABC123.OtherRecipes.txtrecipe
Last updated: 2024-05-21
Post by kumareasu on Persistent variable storage
CODESYS Forge
talk
(Post)
Is there any function function block which can store the persistent variable in HDD/SSD immediatley. My observation is that the persistent variable is getting stored when we shut down or restart the system (Windows+ CoDeSys RTE SL ). the persistent variables are not stored in HDD/SSD, if I power off the system without proper shutdown. Seeking your feedback.
Last updated: 2024-06-12
Post by trannhantxqt on Tripod rotary coordinate is not correct with right hand rule
CODESYS Forge
talk
(Post)
Hi all, I work with tripod rotary kinematics in codesys robotics lib and I got a problem with WCS coordinate. My robot WCS dont look like right hand rule, you can see in the image. (WCS Y axis is negative) Anyone here get the same problem? :D It make me so confuse.
Last updated: 2024-06-22
Post by installwhat on Tripod rotary coordinate is not correct with right hand rule
CODESYS Forge
talk
(Post)
https://www.instructables.com/Work-Coordinate-System/ https://www.researchgate.net/figure/The-WCS-Axis-follows-the-Right-Hand-Rule-Left-Where-the-Z-Axis-Points-Towards-the_fig1_288835535#:~:text=Hwa%20Jen%20Yap-,The%20WCS%20Axis%20follows%20the%20Right%20Hand%20Rule%20(Left)%20Where,tool%20relative%20to%20the%20WCS. https://help.autodesk.com/view/ACDMAC/2025/ENU/?guid=GUID-02A08BCD-B4E5-4068-9932-810EF3049218
Last updated: 2024-06-23
Post by scrisp on Source code changes since last download
CODESYS Forge
talk
(Post)
Why does CODESYS 3.5 show the message “Source code changes since last download” even though I did not create or modify any new variables? When I go online with the PLC, it detects changes and suggests synchronizing, but nothing was actually changed in the project. What could cause this and how can I fix it?
Last updated: 2025-11-28
Post by paro on Modbus Client Request Not Processed
CODESYS Forge
talk
(Post)
Hi, Problem in your code is that you are not calling the ClientFb cyclic. Please look at the Example from CODESYS: https://forge.codesys.com/prj/codesys-example/modbus/home/Home/ Your code works if the client fb is called cyclic! IF NOT initDone THEN initDone := TRUE; // configure clientTcp clientTcp(aIPaddr:=Ethernet.IPAddress, uiPort:=502); // configure clientSerial clientSerial(iPort:=SysCom.SYS_COMPORT2, dwBaudRate:=SysCom.SYS_BR_115200, byDataBits:=8, eParity:=SysCom.SYS_EVENPARITY, eStopBits:=SysCom.SYS_ONESTOPBIT, eRtuAscii:=ModbusFB.RtuAscii.RTU); // configure clientRequestReadCoils_1 clientRequestReadCoils_1(rClient:=clientTcp, uiUnitId:=42, udiTimeout:=TO_UDINT(T#10MS)); // configure clientRequestWriteSingleRegister clientRequestWriteSingleRegister(rClient:=clientTcp, uiUnitId:=43, udiTimeout:=TO_UDINT(T#10MS)); // configure clientRequestReadCoils_2 clientRequestReadCoils_2(rClient:=clientTcp, uiUnitId:=44, udiTimeout:=TO_UDINT(T#10MS)); // configure clientRequestReadInputRegisters clientRequestReadInputRegisters(rClient:=clientTcp, uiUnitId:=44, udiTimeout:=TO_UDINT(T#10MS)); END_IF // call the client FB's clientTcp(); clientSerial(); // call client request FB's clientRequestReadCoils_1(rClient:=clientTcp, xExecute:=TRUE, uiStartItem:=2, uiQuantity:=3, pData:=ADR(aDataCoils_1[0])); // for more details see Example_TCP, especially ClientRequest control (xExecute, xDone, xError). IF clientRequestReadCoils_1.xDone THEN // get data from aDataCoils_1 ... END_IF clientRequestWriteSingleRegister(rClient:=clientTcp, xExecute:=TRUE, uiItem:=3, uiValue:=123); clientRequestReadCoils_2(rClient:=clientTcp, xExecute:=TRUE, uiStartItem:=2, uiQuantity:=3, pData:=ADR(aDataCoils_2[0])); clientRequestReadInputRegisters(rClient:=clientTcp, xExecute:=TRUE, uiStartItem:=16, uiQuantity:=3, pData:=ADR(aDataInputRegisters[0]));
Last updated: 2024-05-29
Post by smercante on Unable to Import PLC Open XML from Easy Remote IO
CODESYS Forge
talk
(Post)
Hello dear. I have the same problem. Could you solve it? Do you use GLV variables?
Last updated: 2023-08-24
Post by jegerjon on Same program to more than one PLC
CODESYS Forge
talk
(Post)
I guess you could archive the project, open the archive and go online. Is that suffiecient for your use case?
Last updated: 2023-08-25
Post by gregor on PFC 200 - codesys V3.5
CODESYS Forge
talk
(Post)
As far as I know, only if someone downloaded sourcecode to the PLC.
Last updated: 2023-08-25
Post by eschwellinger on Problems connecting to Codesys 4.9.0.0 runtime on my Wago PFC200
CODESYS Forge
talk
(Post)
I've send out a workaround for this.. Best Regards Edwin
Last updated: 2023-08-26
Post by totorovic on CSVReaderInit returns error : INVALID_HANDLE
CODESYS Forge
talk
(Post)
Hello, Can we please have some details about the error : INVALID_HANDLE? So we can try to avoid it.
Last updated: 2023-08-28
Post by eschwellinger on v3.5 SP19 - Modbus TCP Devices - Channel Limit?
CODESYS Forge
talk
(Post)
Guess you could just add two modbus slaves with the same ip, to enlarge the 10 channel limit.
Last updated: 2023-08-28
Post by reinier-geers on Trun off webvisu
CODESYS Forge
talk
(Post)
How do i see if Webvisu is active and how to shot down if i dont want webvisu?
Last updated: 2023-08-29
Post by eschwellinger on new feature: list/view plclogs from the plcs
CODESYS Forge
talk
(Post)
Since 1.31.0.0 version there is this really helpful feature to browse the plclogs remote via CODESYS Automation server:
Last updated: 2023-08-30
Post by jegerjon on VPN
CODESYS Forge
talk
(Post)
Hi, witch VPN provider for remote PLC Acess do you use/recomend? Preferedbly one where you can Grant certain users acess to specific controllers.
Last updated: 2023-09-06
Post by jegerjon on VPN
CODESYS Forge
talk
(Post)
Hi, witch VPN provider for remote PLC Acess do you use/recomend? Preferedbly one where you can Grant certain users acess to specific controllers.
Last updated: 2023-09-06
Post by jegerjon on VPN
CODESYS Forge
talk
(Post)
Hi, witch VPN provider for remote PLC Acess do you use/recomend? Preferedbly one where you can Grant certain users acess to specific controllers.
Last updated: 2023-09-06
Post by jari-koivuluoma on JSON_Utilities_SL JSONFileWriter error NULL_POINTER
CODESYS Forge
talk
(Post)
FB jsonFileWriter gives a NULL_POINTER error, why? JSONByteArrayWriter works fine so the JSONData FB should be fine. The device is CODESYS Control Win V3 x64 in simulation mode. Codesys version is V3.5 SP16 Patch 5 JSON_Utilities_SL version is 1.3.0.0 Src: ST_TestStruct1a; TXT: WSTRING(10000); MakeJSON : BOOL := TRUE; SrcJSONData: JSON.JSONData; jsonFileWriter : JSON.JSONFileWriter; IF MakeJSON THEN MakeJSON := FALSE; // Struct data to JSONData FB F_TestStructToJSON(ADR(Src),ADR(SrcJSONData)); // Writing to file jsonFileWriter( xExecute := TRUE, sFileName := 'c:\JSONTEST\JSON.txt', eEncoding := JSON.Encoding.UTF_16, xAsyncMode := TRUE, jsonData := SrcJSONData ); // Waiting to finish WHILE jsonFileWriter.xBusy DO ; END_WHILE // To text jsonArrayWriter( xExecute := TRUE, pwData := ADR(TXT), udiSize := SIZEOF(TXT), jsonData := SrcJSONData, xAsyncMode := FALSE, ); END_IF
Last updated: 2023-09-08