Search talk: Object reference not set to an instance of an object

 
<< < 1 .. 277 278 279 280 281 .. 293 > >> (Page 279 of 293)

Post by mmpl on AWS IoT core CODESYS CODESYS Forge talk (Post)
It is looks like there is problem with your JASON conversion. If you share picture of your payload conversion will give more information.
Last updated: 2024-04-10

Post by eschwellinger on Can't use new licensing with Raspberry Pi CODESYS Forge talk (Post)
please delete the contents of the following directory - /var/opt/codesys/.cmact_license/ then start a new SPS and then the activation should work (then you have a new empty UFC SoftContainer)
Last updated: 2024-04-22

Post by k2saki on Discontinuity of A/B/C axis movement. CODESYS Forge talk (Post)
Hello. Good morning. I have a same problem with short-segment G01 in GCode even in XY Axis. ( I'm using SMC_ReadNcFile2, SMC_NcInterpreter, SMC_CheckVelocities before IPO , watching Youtube tutorial video.. ) How did you solve this problem ?
Last updated: 2024-04-29

Post by rabaggett on CODESYS control for Raspberry Pi 64 SL errors CODESYS Forge talk (Post)
Update: I found my error in the Scale function, where I used UINT_TO_REAL instead of DWORD_TO_REAL. I fixed it, errors unchanged.
Last updated: 2024-05-02

Post by micik on "CAA" meaning in library names CODESYS Forge talk (Post)
Hello, what CAA stands for? Since it is a collection of different libraries, does it mean it is created by some specific organization? Thanks!
Last updated: 2024-05-31

Post by ignat on [SOLVED] Safety EL6900 - SELC0012 Invalid number of connections[ CODESYS Forge talk (Post)
Hi kurvanov, could you please share the video you mentioned. I am struggling with basic data intechange between safety module and basic plc logic
Last updated: 2024-06-17

Post by kalmeyer on Stepper motor control with (SM_Drive_RaspStepper_direct) CODESYS Forge talk (Post)
Is there perhaps a place where I can see examples of programming with different instructions? This would be a great help. Maybe there are some places where ready-made programs are posted that can be downloaded and tested? /Klaus
Last updated: 2025-11-10

Post by jonasz on Deploy LicenseServer for Linux SL CODESYS Forge talk (Post)
After carefully studying the documentation, I have a question: is a second hardware-independent time source required for the correct operation of the VirtualSafety system?
Last updated: 2025-11-17

Post by mariusz997 on Visualisation - internal error CODESYS Forge talk (Post)
Hi - problem solved. I had 3 version of codesys on system and they didn't like each other. After uninstall all and install again only one version now everything is OK
Last updated: 2025-11-12

Post by tristan on Textfield display problem CODESYS Forge talk (Post)
Hello Tim, I am using CODESYS Visu V4.8.1.0. It works when I turn off the "Support client animation and overlay of native elements". But if I do that, dialog box moving and other options are also disabled so it is a bit problematic. Thank you for helping.
Last updated: 2025-11-27

Post by rene-h on ClientFilter used the same Client ID 2 times - Bug? CODESYS Forge talk (Post)
Hello, like the topic name says, i have a problem on one Visu which i cannot reproduce on another Visu. We filter buttons with input locks and visible items with [CURRENTCLIENTID] on different WebVisu's with different ID's, and one time the itfClient used the same Client ID for 2 Clients, so the Visualization on the first ID was wrong, because that one which connected after did not have the same permissions like the first, so the first one was blocked. We read the Clients with the VisuClientIteration project: //count active clients gCli.iNumberOfClients:=gCli.iNumberOfClients+1; // if client is active write data to global struct IF gCli.iNumberOfClients > 0 THEN gCli.astClientInfo[gCli.iNumberOfClients-1].iClientID:=itfClient.ClientId ; gCli.astClientInfo[gCli.iNumberOfClients-1].stCurrentVisu:=itfClient.CurrentVisuName; gCli.astClientInfo[gCli.iNumberOfClients-1].wsUserName:=itfClient.UserName; gCli.astClientInfo[gCli.iNumberOfClients-1].sIpAddress:=itfClient.GetIPv4Address(); gCli.astClientInfo[gCli.iNumberOfClients-1].ClientType:=itfClient.ClientType; END_IF Runtime from the device: 3.5.19.20 Codesys we use: 3.5.20.10 I added a screenshot where the same ID exists 2 times. Thanks for your answers.
Last updated: 2025-05-14

Post by markushunter on Different behavior between the "Start" button in the IDE and the Cmp function "AppStartApplication()" CODESYS Forge talk (Post)
In our application with CODESYS V3.5 SP19 Patch 5 and the Soft-PLC Name: CODESYS Control Win V3 x64 Typ: 4096 ID: 0000 0004 Version: 3.5.19.50 the application behaves differently when we start the application via Cmp.AppStartApplication(pApp) than when we press the "Start" button in online mode in the IDE. Unfortunately, it looks like the AppStartApplication() function, which is called in the "StopDone" system event, is not able to restart the fieldbus driver correctly, in our case the EtherNet_IP_Scanner: Name: EtherNet/IP Scanner Hersteller: 3S - Smart Software Solutions GmbH Kategorien: EtherNet/IP Scanner Typ: 100 ID: 0000 100B Version: 4.5.1.0 Bestellnummer: 1 And one EtherNet/IP adapter Name: FANUC Robot R30iB Plus Hersteller: FANUC Robotics America Kategorien: EtherNet/IP Remote Adapter Typ: 101 ID: 356_12_4_3 Version: Major Revision=16#3, Minor Revision = 16#1 Beschreibung: EtherNet/IP Target imported from EDS File: fanucrobot0301_r30ibp.eds Device: FANUC Robot R30iB Plus Version Konfiguration 3.5.6.0 The application was cold reset in both cases via CmpApp.AppReset(pApp := pApp, usResetOption := CmpApp.RTS_RESET_COLD. Does anyone know the difference between the functions or services executed by the "START" button in online mode and Cmp.AppStartApplication()? Thanks and best regards, markushunter
Last updated: 2024-03-20

Post by markushunter on Different behavior between the "Start" button in the IDE and the Cmp function "AppStartApplication()" CODESYS Forge talk (Post)
In our application with CODESYS V3.5 SP19 Patch 5 and the Soft-PLC Name: CODESYS Control Win V3 x64 Typ: 4096 ID: 0000 0004 Version: 3.5.19.50 the application behaves differently when we start the application via CmpApp.AppStartApplication(pApp) than when we press the "Start" button in online mode in the IDE. Unfortunately, it looks like the AppStartApplication() function, which is called in the "StopDone" system event, is not able to restart the fieldbus driver correctly, in our case the EtherNet_IP_Scanner: Name: EtherNet/IP Scanner Hersteller: 3S - Smart Software Solutions GmbH Kategorien: EtherNet/IP Scanner Typ: 100 ID: 0000 100B Version: 4.5.1.0 Bestellnummer: 1 And one EtherNet/IP adapter Name: FANUC Robot R30iB Plus Hersteller: FANUC Robotics America Kategorien: EtherNet/IP Remote Adapter Typ: 101 ID: 356_12_4_3 Version: Major Revision=16#3, Minor Revision = 16#1 Beschreibung: EtherNet/IP Target imported from EDS File: fanucrobot0301_r30ibp.eds Device: FANUC Robot R30iB Plus Version Konfiguration 3.5.6.0 The application was cold reset in both cases via CmpApp.AppReset(pApp := pApp, usResetOption := CmpApp.RTS_RESET_COLD. Does anyone know the difference between the functions or services executed by the "START" button in online mode and Cmp.AppStartApplication()? Thanks and best regards, markushunter
Last updated: 2024-03-20

Post by markushunter on Different behavior between the "Start" button in the IDE and the Cmp function "AppStartApplication()" CODESYS Forge talk (Post)
In our application with CODESYS V3.5 SP19 Patch 5 and the Soft-PLC Name: CODESYS Control Win V3 x64 Typ: 4096 ID: 0000 0004 Version: 3.5.19.50 the application behaves differently when we start the application via Cmp.AppStartApplication(pApp) than when we press the "Start" button in online mode in the IDE. Unfortunately, it looks like the AppStartApplication() function, which is called in the "StopDone" system event, is not able to restart the fieldbus driver correctly, in our case the EtherNet_IP_Scanner: Name: EtherNet/IP Scanner Hersteller: 3S - Smart Software Solutions GmbH Kategorien: EtherNet/IP Scanner Typ: 100 ID: 0000 100B Version: 4.5.1.0 Bestellnummer: 1 And one EtherNet/IP adapter Name: FANUC Robot R30iB Plus Hersteller: FANUC Robotics America Kategorien: EtherNet/IP Remote Adapter Typ: 101 ID: 356_12_4_3 Version: Major Revision=16#3, Minor Revision = 16#1 Beschreibung: EtherNet/IP Target imported from EDS File: fanucrobot0301_r30ibp.eds Device: FANUC Robot R30iB Plus Version Konfiguration 3.5.6.0 The application was cold reset in both cases via CmpApp.AppReset(pApp := pApp, usResetOption := CmpApp.RTS_RESET_COLD. Does anyone know the difference between the functions or services executed by the "START" button in online mode and Cmp.AppStartApplication()? Thanks and best regards, markushunter
Last updated: 2024-03-20

Post by willbechel on Errors about PLC configuration in CoDeSYs software CODESYS Forge talk (Post)
I saved it as the same project but in a different location. I opened this "new project". I clicked on the "Direct Login from Automation Builder" button. It automatically directed me to CODESYS, where I was able to create the "Create Boot Project" but first I also clicked login again but inside CODESYS keeping the automation builder login online. Additional Information: The "Create Boot Project" function in CODESYS is used to create a project that will automatically start when the controller is booted up. To create a boot project, you must first create a new project in CODESYS. Once you have created a new project, you can then use the "Create Boot Project" function to create a boot application. The "Create Boot Project" function will create a new application that is based on the current project. The new application will be saved in the same location as the current project. You can then download the new application to the controller.
Last updated: 2024-02-01

Post by willbechel on Project Login Problem CODESYS Forge talk (Post)
I saved it as the same project but in a different location. I opened this "new project". I clicked on the "Direct Login from Automation Builder" button. It automatically directed me to CODESYS, where I was able to create the "Create Boot Project" but first I also clicked login again but inside CODESYS keeping the automation builder login online. Additional Information: The "Create Boot Project" function in CODESYS is used to create a project that will automatically start when the controller is booted up. To create a boot project, you must first create a new project in CODESYS. Once you have created a new project, you can then use the "Create Boot Project" function to create a boot application. The "Create Boot Project" function will create a new application that is based on the current project. The new application will be saved in the same location as the current project. You can then download the new application to the controller.
Last updated: 2024-02-01

Post by rajatdas2005 on Codesys Virtual control SL CODESYS Forge talk (Post)
Dear All, This is regarding Codesys Virtual control SL demo version. I am facing one issue. First I will describe the steps what I have followed till now. 1. In a PC I have Windows OS. Here Codesys IDE is installed, and also using the installer option of IDE I have also installed Codesys Virtual control SL. 2. A edge-gateway is also running in the same windows PC as local host. 3. Next I have a seperate PC with Ubuntu OS with docker installed. This machine is in the same network. 4. Now I have created a project in Windows machine using device "Codesys Virtual control SL". 5. In the Ubuntu machine I am running the Codesys Virtual control SL as docker and it is using the ubuntu machine network only. 6. Next using the localhost edge-gateway when I am searching the virtual control SL docker it is able to detect it. (screenshot attached) 7. But after creating the creadentials it is telling No Device is responding. 8. I have also checked the wireshark logs and able to see that in destination port 11740 data is coming. 9. From windows PC telnet ip 11740 is also working. 10. Ping is also working ===========================================LOGS ========================= sudo ss -tlnp | grep -E "(443|1217|4840|8080|11740)" LISTEN 0 10 10.135.114.142:4840 0.0.0.0: users:(("codesyscontrol.",pid=41864,fd=21)) LISTEN 0 10 172.18.0.1:4840 0.0.0.0: users:(("codesyscontrol.",pid=41864,fd=24)) LISTEN 0 10 172.17.0.1:4840 0.0.0.0: users:(("codesyscontrol.",pid=41864,fd=23)) LISTEN 0 10 127.0.0.1:4840 0.0.0.0: users:(("codesyscontrol.",pid=41864,fd=26)) LISTEN 0 10 192.168.122.1:4840 0.0.0.0: users:(("codesyscontrol.",pid=41864,fd=22)) LISTEN 0 5 0.0.0.0:11740 0.0.0.0: users:(("codesyscontrol.",pid=41864,fd=20)) LISTEN 0 128 0.0.0.0:8080 0.0.0.0: users:(("python3",pid=1280,fd=4)) LISTEN 0 10 172.19.0.1:4840 0.0.0.0: users:(("codesyscontrol.",pid=41864,fd=25))
Last updated: 2025-08-06

Post by struccc on Bibliothek: floatingpointutils CODESYS Forge talk (Post)
The issue s the byte order typically in this case. Can be especially problematic with floating point numbers - even more tricky if transferred with a word based protocol. It is a peasant way to try out the alternatives, dword order can be a-b-c-d, b-a-d-c, c-d-a-b, d-c-b-a where a is the most significant, d is the least significant byte. So all you need is to swap the bytes in your dword, until you get the expected result. If you don't want to mess writing code for this, I'd recommend CAA_Memory library for that: MEM.ReverseBYTEsInDWORD and MEM.ReverseWORDsInDWORD functions would definitively do the trick. Otherwise, can do like this: VAR dwIn : DWORD := 16#11223344; dwOut : DWORD; rOut : REAL; pIN : POINTER TO BYTE; pOUT : POINTER TO BYTE; END_VAR pIN := ADR(dwIn); //pOUt := ADR(dwOut); pOUt := ADR(rOut); pOut[0] := pIN[3]; pOut[1] := pIN[2]; pOut[2] := pIN[1]; pOut[3] := pIN[0]; Ugly, but does the job...
Last updated: 2024-11-19

Post by imdatatas on Programmatically change Tappet on a cam CODESYS Forge talk (Post)
Yes, There is. As explained "Manual creation of CAM structure" on below section. Likewise tappet structure also can be create manual and value of the switching point can be change during IEC program running. https://content.helpme-codesys.com/en/CODESYS%20SoftMotion/_sm_basic_cam_programmatic_creation.html Just create a cam table and define some tapped points as sample for your project. Then on project compile, the created cam tapped data is converted internally into a global variable list. By clicking "Display generated code" in the "cam editor", you can display the automatically created global variables for both cam & tappets. Regards, Imdat
Last updated: 2025-04-02

Post by ouzago on ERROR C0138: No matching 'FB_Init' method found for instantiation of VisuClientObjectMgr CODESYS Forge talk (Post)
When I created a new project in CODESYS using the "Standard Project" template and then added a Visualization, I was receiving the C0138 error during compilation. This issue persisted even with a new, completely empty project. A Quick and Effective Solution (My Method): After many attempts, I solved the problem as follows: From the File -> New Project menu, I selected the "HMI Project" template directly, instead of the "Standard Project" template. After creating the project with this template, I added my POUs, Tasks, and programs (e.g., Ladder, ST). Using this method, the project compiled successfully without any errors. So, my question is: are there any other solutions besides this method?
Last updated: 2025-10-07

Post by docker on Webvisu client connection monitoring CODESYS Forge talk (Post)
Thanks for the reply, i am using codesys SP16 patch 5 as this is the version that is compatible with my IFM controller. i am accessing the lastusage variable from the VisuStructClientData structure through a pointer. when i log in it lists the time since last log in but does not continually count, it remains a static value which isnt useful. hopefully you can help. Thankyou
Last updated: 2024-08-26

Post by aliazzz on Raspberry Pi 3: Linux/ARMHFv7 unknown container technology CODESYS Forge talk (Post)
Hi CODESYS team! It seems Podman for Raspberry Pi 3 is not detected correctly in the latest "Deploy Control SL 4.14.0.0" : Linux/ARMHFv7 unknown container technology. 1) The Communication Tab, device information section shows podman technology as DETECTED. 2) The Runtime Deployment menu message says: "unknown container architecture" 3) The pulldown window under the deployment tab doesn't show the options for ARMHF Virtual Edge SL and ARMHF Virtual Control SL. I hope you can fix this soon and keep up the great work!
Last updated: 2024-12-15

Post by kuapiz on Camera RTSP Feed CODESYS Forge talk (Post)
Hello, I'm facing the same problem, I can access the FLIR AX Series camera through the IP converter software (go2rtc). In the CODESYS 3.5.19 patch 7 software, the streaming does not appear in the webvisu even using the URL "http://xxx.xxx.x.xxx:1984/stream.html?src=flirr". I used the "RTC" and "MJPG" modes. HW: PFC200 750-8217/600-000. FW: v27. If anyone has a solution, could you help us?
Last updated: 2025-03-05

Post by wayne-riesterer on Assignment Efficiency - Repetitive Assignment vs IF statement CODESYS Forge talk (Post)
Hello Can anyone see any problems with constant assignment as in the following statement: Coils[0] := Coils[0] OR (Buttons[0] AND Sensors[0] > 6); Rather than using the more verbose and vertically-larger: IF NOT Coils[0] AND Buttons[0] AND (Sensors[0] > 6) THEN Coils[0] := TRUE; END_IF Also, is the test expression short-circuited in the latter case? In other words, will the runtime move on after it sees Coils[0] = FALSE AND? Thanks
Last updated: 2025-03-07

Post by timvh on Minimum system requirements for codesys control standard S CODESYS Forge talk (Post)
It depends on your application which CPU speed and RAM size you need. If you think the Control Standard S license is sufficient then my guess is that your selected PC has no problem running your application. There are no more "hardware" based single licenses available anymore, only application based licenses. So this "Raspberry Pi" restriction for home automation is not applicable anymore. For more information see: https://store.codesys.com/en/howto_applicationbasedlicenses
Last updated: 2024-01-14

<< < 1 .. 277 278 279 280 281 .. 293 > >> (Page 279 of 293)

Showing results of 7301

Sort by relevance or date