Search talk: cds data type array

 
<< < 1 .. 27 28 29 30 31 .. 55 > >> (Page 29 of 55)

Save the data log file in the USB from the visualization CODESYS Forge talk (Thread)
Save the data log file in the USB from the visualization
Last updated: 2021-01-25

Send Data to a specified Register with TCP/IP Cleint Server CODESYS Forge talk (Thread)
Send Data to a specified Register with TCP/IP Cleint Server
Last updated: 2021-08-25

Can't link process data variables to IO from a positionsensor while using a demo soft PLC CODESYS Forge talk (Thread)
Can't link process data variables to IO from a positionsensor while using a demo soft PLC
Last updated: 2022-03-04

can I send data over udp/tcp in simulation mode? CODESYS Forge talk (Thread)
can I send data over udp/tcp in simulation mode?
Last updated: 2016-06-05

Profinet Master on RPI3 with CodeSys Control - No live data on I/O CODESYS Forge talk (Thread)
Profinet Master on RPI3 with CodeSys Control - No live data on I/O
Last updated: 2017-07-06

Wie kann ich auf alle Benutzerdaten zugreifen? How to access User-Data? CODESYS Forge talk (Thread)
Wie kann ich auf alle Benutzerdaten zugreifen? How to access User-Data?
Last updated: 2018-01-16

Wago_IO-Link Master 750-657 unable to read all data frame CODESYS Forge talk (Thread)
Wago_IO-Link Master 750-657 unable to read all data frame
Last updated: 2022-06-10

Error 3803: (2): Out of data global memory. Variable 'CAN1_CANREMOTE_INFO'. 5904 bytes. CODESYS Forge talk (Thread)
Error 3803: (2): Out of data global memory. Variable 'CAN1_CANREMOTE_INFO'. 5904 bytes.
Last updated: 2019-09-10

Trend to display Wago 750-880 SD memory data logging CODESYS Forge talk (Thread)
Trend to display Wago 750-880 SD memory data logging
Last updated: 2012-10-24

Error 3803: (2): Out of data global memory. Variable 'CAN1_CANREMOTE_INFO'. 5904 bytes. CODESYS Forge talk (Thread)
Error 3803: (2): Out of data global memory. Variable 'CAN1_CANREMOTE_INFO'. 5904 bytes.
Last updated: 2019-09-06

Cold reset / exchange of data between applciation on one PLC CODESYS Forge talk (Thread)
Cold reset / exchange of data between applciation on one PLC
Last updated: 2016-04-16

Not able to see input data coming from eip adapter on codesys CODESYS Forge talk (Thread)
Not able to see input data coming from eip adapter on codesys
Last updated: 2024-03-07

Has anyone fed ESP32 sensor data into CODESYS (via MQTT/Modbus)? CODESYS Forge talk (Thread)
Has anyone fed ESP32 sensor data into CODESYS (via MQTT/Modbus)?
Last updated: 2025-10-29

Using SCADA Data and C# Integration for Real-Time Production KPI Monitoring CODESYS Forge talk (Thread)
Using SCADA Data and C# Integration for Real-Time Production KPI Monitoring
Last updated: 2026-06-16

Post by critcho on WebVisu Numpad dialog - Dialogtitle not accepting string variable CODESYS Forge talk (Post)
I have a WebVisu page which is re-used for multiple types of gas; it displays the alarm thresholds etc. for one gas at a time. I have an array of structures holding the set-points for each of the gasses. I'm trying to change the dialog title for the value input pop-up (VisuDialogs.Numpad). The Dialogtitle is set to Gas_Alarms.HighAlarmActivationLevelDialog, which is a string(50): When the gas type is changed (page first loaded, or prev/next buttons), METHOD Gas_Alarms.Update_Display_Variables is called, to update the strings used for the dialog titles so it shows GasName High Alarm Activation Level (EngineeringUnits), e.g. CO2 High Alarm Activation Level (PPM): HighAlarmActivationLevelDialog := Insert(' High Alarm Activation Level ()', EngineeringUnits, 30); HighAlarmActivationLevelDialog := Insert(HighAlarmActivationLevelDialog, GasName, 0); (That's not where the problem is, I'm just explaining why I'm using a variable dialogue title.) The variables used are definitely strings, but i'm always getting the error: "The type of the dialog title must be either STRING or WSTRING". I've tried moving HighAlarmActivationLevelDialog etc. to the GVL and also changing them to WSTRING, I even tried adding them to the structure array, but I always get the same error. Clearing the dialog title for that element removes the error - so I'm confident it's not a phantom error caused by something else. But I should be able to add these titles, can't just nuke them all to make it work. The MinVal and MaxVal for the Numpad are called from the array, e.g. GVL.Gas_Alarm_Configs[0].ScaledValueMIN, they are not getting an error. I am using array indexes 1 - 5 for the gasses, when I load the form or change gas, I copy the selected index to index 0 of the array, and values from Gas_Alarm_Configs[0].[ALL] are displayed on the page. When they hit save, I copy Gas_Alarm_Configs[0].[ALL] to Gas_Alarm_Configs[CurrentGasIndex].[ALL]. (ALL just means every element, I can't figure out how to display an asterix in this question... :) ) I've searched online for variable title dialog, but not found anything to help. Thanks for your help!
Last updated: 2025-05-29

Post by talhaali on Data logging from codesys to Microsoft Access CODESYS Forge talk (Post)
Hi, I want to write data from Codesys to Microsoft access and want to save it as mdb file. There is a way to store data in excel(CSV) file but instead of this, I want to save data in access (mdb) file. Does anyone have a solution? Thanks
Last updated: 2024-04-04

Post by talhaali on Data logging from codesys to Microsoft Access CODESYS Forge talk (Post)
Hi, I want to write data from Codesys to Microsoft access and want to save it as mdb file. There is a way to store data in excel(CSV) file but instead of this, I want to save data in access (mdb) file. Does anyone have a solution? Thanks
Last updated: 2024-04-04

Post by osande on Trend/trace data CODESYS Forge talk (Post)
Trend ....
Last updated: 2026-03-13

Post by osande on Trend/trace data CODESYS Forge talk (Post)
The standard Trace works...
Last updated: 2026-03-13

Post by trycyclepower on How to transfer data from DINT to Union(16 Bools) which I need to use in Few FBs CODESYS Forge talk (Post)
I have DINT data from drive input and would like to use this data in Bools in bunch of the FBs. I have tried using Union but it is not working. Please suggest
Last updated: 2023-12-14

Post by alez on CANOpen SDO to write VISIBLE STRING CODESYS Forge talk (Post)
Hello, I am experiencing difficulties in configuring a CANopen device by sending SDOs. In particular I am attempting to write an Object Dictionary that has VISIBLE STRING as the Data Type. When I try to configure the sending of an SDO from Codesys to configure this parameter I am not allowed to enter a string value. In my particular case I am trying to change the Manufacturer Device Name ( Index 0x1008 ). Could it be that Codesys doesn't manage these types of variables?
Last updated: 2024-04-29

Post by ndzied2 on Rounding error in simple addition CODESYS Forge talk (Post)
This is a consequence of how computers store floating point numbers. 0.1 cannot be exactly represented in a computer. This is not a CoDeSys thing. Here is a link to a converter to show you the exact value that is represented when you use a REAL data type (which is a 32 bit float). https://baseconvert.com/ieee-754-floating-point If you really need to keep track of 0.1 increments. use INT OR DINT and then add 1 each time and assume that there is one decimal place.
Last updated: 2024-05-24

Post by pernockham on Inheritence of struct, CODESYS Forge talk (Post)
Im looking for a way to define predefined version of the same structures through "extends"/inheritance. What I want to do is best shown with an example: TYPE log_item_val_type : ( BOOL_ := 0, INT_, REAL_, STRING_ ); END_TYPE TYPE LOG_DATA_BASE STRUCT val_type : log_item_val_type; (* value, name etc *) ENDSTRUCT ENDTYPE (* this/below is not possible as I understand from the compiler?? *) TYPE LOG_DATA_BOOL extends LOG_DATA_BASE : STRUCT val_type : log_item_val_type := log_item_val_type.BOOL_; END_STRUCT END_TYPE TYPE LOG_DATA_INT extends LOG_DATA_BASE : STRUCT val_type : log_item_val_type := log_item_val_type.INT_; END_STRUCT END_TYPE etc. for LOG_DATA_REAL and ..STRING. The system will not allow me to "re-define" "val_type" however. Instead I must do the work-around of defining four different types with all fields individually defined. The benefit if I could extend the base item would be that Im (more) sure the structures are identical. In usage I can call in a specific type rather use the base type and assign which type. Usage by pointer/ref to log_data_base would also be easier.. (* Usage: *) log_data : log_data_int := (name, value etc.) (* Instead of: *) log_data : log_data_base := (name, value, val_type).. Is this possible to achieve in some way that I have missed?
Last updated: 2025-03-05

Post by docker on Webvisu client connection monitoring CODESYS Forge talk (Post)
Hi mate, With this snippet i was able to see the lastusage variable count, but it would not iterate between clients? i was only able to access the data of the target visu. it threw an error with the array of pointers stating it was not able to convert etc. also when i tried it with the while loop it created an endless loop and crashed the program. any ideas? Thankyou
Last updated: 2024-09-10

Post by clarenced on Multiple applications on one device sharing variables. CODESYS Forge talk (Post)
I got this working using OPC UA. In the logic application I just added a Symbol Configuration. In the HMI application I added a Data Sources Manager and OPC UA Data Source. The one thing I don't like is the way the tags end up being named in the HMI application. In the logic application I have a program named PLC_PRG. It has a variable named testDINT. In the logic application the name I get for this variable is DeviceSet.CODESYS_Control_Win_V3_x64.Resources.Logic.Programs.PLC_PRG.testDINT. This is very long and looks like it could change if I used this on a different device type. Any ideas how I could get this name shortened down to just PLC_PRG.testDINT like it is on the Logic application?
Last updated: 2025-03-06

<< < 1 .. 27 28 29 30 31 .. 55 > >> (Page 29 of 55)

Showing results of 1354

Sort by relevance or date