Post by sercan on Connecting Parameter 'A' in G-Code to Physical Axis in CNC Project
CODESYS Forge
talk
(Post)
I want to run the following command by linking it to the A-Axis: G01 A45.0 Which TRAFO should I use to do this? SMC_TRAFO_5Axes and SMC_TRAFO_GantryCutter3 function blocks did not work! For example, when SMC_TRAFO_5Axes is used, parameters B and C can be resolved by the transformer. However, parameter A cannot be resolved. Only SMC_Interpolator displays the value of parameter A in the SMC_Interpolator => piSetPosition.dA output. Should I drive this axis with SoftMotion commands (MC_MoveAbsolute etc.)?
Last updated: 2025-05-07
Post by romrot on MS SQL Compact cutting off Database name?
CODESYS Forge
talk
(Post)
I'm trying to use an fbMsSQL_compact function to read data from an SQL database. It works with some databases, but there is one database that I can't seem to get it to work on. It's set up the same as the other databases that I've tested with the only difference I see is that the name of the database is cut off in the status message. I'll get a message like "User: User logged out succesfully from database: 12345" But the whole name of the database is something like 1234567.
Last updated: 2025-08-21
Post by nathant on Some visualization objects disappear when user is logged in?
CODESYS Forge
talk
(Post)
I am deploying a webvisu on Codesys 3.5 SP 19.2 with legacy user management. I noticed that when a user logs in, some text and a rectangle I have (for aesthetics) both disappear. I made sure that none of the objects in question are linked to a state variable. Anyone know the cause/solution to this? Nothing crucial to the machine's function is lost, but it is a little annoying.
Last updated: 2023-12-15
Post by paro on Client Independent Visualization Switching
CODESYS Forge
talk
(Post)
Hi, can you please provide a new example for the topic at CODESYS "Client Independent Visualization Switching" https://forge.codesys.com/prj/codesys-example/client-independ/home/Home/ Since a few versions, the functions used cause warning messages. Examples for the use of all function blocks from the Visu Utils would generally be very helpful! Several people have put together an example here: https://forum-de.codesys.com//download/file.php?id=2240 BR Patrick
Last updated: 2023-12-20
Post by wiresplus on INT_TO_WORD function not working
CODESYS Forge
talk
(Post)
Hello, I need to take an INT input, and convert it to a WORD value. VAR DRV2Speed : WORD; //IO card takes a WORD where 16000 = full 10V output (equivalent to 50Hz) PumpFillSpeed : INT; //Users enter a value between 0 and 50 END_VAR IF <conditions> THEN DRV2Speed :=INT_TO_WORD((PumpFillSpeed/50)*16000); END_IF </conditions> According to me this should work - but it stays at 0, no matter what. What am I doing wrong?
Last updated: 2024-01-26
Post by ojz0r on INT_TO_WORD function not working
CODESYS Forge
talk
(Post)
That calculation will not work the way you expect it to. If PumpFillSpeed is limitied to 0-50 then the only whole number would be 50/50 = 1 everything else is 0.0-0.9999... and since you are using word and integer only 50 would work since there is no representation for mantissa in integer values. Declare a temporary real variable and do the calculation and then do a REAL_TO_WORD in the DRV2Speed assignment.
Last updated: 2024-01-26
Post by thomas-moba on "sudo"-Befehle über die Funktion "SysProcessExecuteCommand2"
CODESYS Forge
talk
(Post)
Hello, I need to execute "sudo" commands via CoDeSys 3.5 SP 19 P5 using the "SysProcessExecuteCommand2" function. Commands without sudo are no problem, but as soon as sudo is used in a .sh or a single command, it does not work. Command=AllowAll is entered under "SysProcess" in CODESYSControl.cfg. Nevertheless it does not work. Does anyone know what the problem could be? Greetings, Thomas
Last updated: 2024-02-01
Post by otdeveloper on IEC 61499
CODESYS Forge
talk
(Post)
It is being worked on by many companies and its even-driven function blocks seem like a natural evolution of the object oriented industrial programming I have seen Gary Pratt (author of the Book of CODESYS and much more) so expertly implement and explain. I would expect CODESYS to have this front and center on their sights and, if they do not, I would be very interested in learning why.
Last updated: 2024-02-09
Post by kleeswi on SysFileOpen does not work after update to V3.5 SP19 Patch 5
CODESYS Forge
talk
(Post)
I use the function SysFile.SysFileOpen(sFileNamePara, SysFile.ACCESS_MODE.AM_WRITE, pErrorFileOpen); to open and write a file. Since the update from Codesys V3.5 SP17 to V3.5 SP19 Patch 5 it does not work anymore. I first had SysFile.SysFileOpen(sFileNamePara, SysFile.ACCESS_MODE.AM_APPEND_PLUS, pErrorFileOpen); in both versions. hFile_Test is a pointer to byte. It gives an exceptional error when dereferencing the hFile_Test pointer. Edit: I use Codesys on a Raspberry pi
Last updated: 2024-02-19
Post by andrej on POU - Access to runtime
CODESYS Forge
talk
(Post)
Hello all, when creating a POU, the Codesys IDE allows the setting "Enable System Call" (in the Settings, Property -> Build), see picture. The name suggest, that runtime functionalities i.e. functions of codesyscontrol such as "stop plc" etc. can be directly called. I tried various approches without success, the following does, unsurprisingly not work. FUNCTION accessRTE: BOOL; ****************************** codesyscontrol.stop(); Can you please tell me how I can make a system call to codesyscontrol from a POU. Or could you provide me with a use case for this setting. Many thanks for your feedback and kind regards Andrej
Last updated: 2024-03-02
Post by ofey on EtherCAT fieldbus
CODESYS Forge
talk
(Post)
Okey, thank you! Do you think it is something in this library, that makes it possible to do the configuration in a PRG? https://content.helpme-codesys.com/en/libs/IODrvEtherCATDriver/Current/IoDrvEtherCAT.html#id1 I think the codesys modbus libraries support configuration and connection to modbus slaves without having to add the slave devices in the device tree. Just do it from function blocks inside the program. I was hoping for something similar with EtherCAT.
Last updated: 2024-04-10
Post by joep on Custom robotics kinematics model debugging
CODESYS Forge
talk
(Post)
When trying to move my axis using any group move instruction I get the following error: SMC_CP_INVALID_PATH_ELEM and axisgroup goes into errorstop state. I tested my methods thoroughly which makes it hard for me to debug. Are there some hidden rules I need to abide to? How would one go about debugging a custom robotics model, since the information inside isn't accesible. Is it possible to find the source of where the function breaks? Any hint in the right direction would be appreciated. Best regards
Last updated: 2024-06-08
Post by timvh on OSCAT Scale_r function not working in LD 4.60 works in LAD2 on 3.5.21sp3
CODESYS Forge
talk
(Post)
It seems like a bug in FBD. Work-around: If you click on the small line between the box and the output variable and delete this, the variable is removed. When you then assign a variable again (Ctrl-A), then you will see that the line will be a bit longer. If you then select the previous variable, you will see that it works.
Last updated: 2025-10-26
Post by youness on CSVReaderInit returns error : INVALID_HANDLE
CODESYS Forge
talk
(Post)
I have Already the same problem when i'm trying to write data more than 10 times in the same file. In fact, i send my data periodicaly to a file that i configured to have permission of W/R in my CodesysContol.cfg. When the Error occurs, i must reboot my machine to success. It means that the problem isn't realted to a limitation of size, but a problem in the function supposed to handle the file. totorovic : allow me to know if you've found a solution to your problem. Thanks.
Last updated: 2025-11-26
Post by nxbp on About Compatibility
CODESYS Forge
talk
(Post)
Let's say I have a CODESYS controller (PLC) with a runtime version around 3.5.19. If I use development software version 3.5.21.40 or a later version that will be released in the future for programming, could there be any problems or malfunctions in the controller's program execution or in the execution of the new, updated function blocks from the newer software? I mostly work with servo-based motion applications, so please keep that in mind when answering, and provide a detailed answer so I don't have to email you again about this topic.
Last updated: 2025-12-11
Post by durallymax on VAR_INFO from inside of a FB to get info on the instance.
CODESYS Forge
talk
(Post)
The help link appears to be broken. When I implemented something similar I had to add {attribute 'reflection} above the declaration of the FB with {attribute 'instance-path'} above the string VAR that would contain the path. Then wrote a function to trim off however much I wanted removed by searching for periods, then formatting it with spaces at the periods and removing brackets on arrays while also breaking up the PascalCase to present it a bit nicer for the end-users.
Last updated: 2025-12-12
Post by antonz on OSCAT Scale_r function not working in LD 4.60 works in LAD2 on 3.5.21sp3
CODESYS Forge
talk
(Post)
That's what I found as well Shaun. I have seen it at least in versions 3.5.21.1 and 3.5.21.3. There seems to be an issue with the FBD/LD package v4.6.0.0. The workaround proposed by Tim works but needs to be done manually on every code change/addition. For now we manually downgrade the FBD/LD package from v4.6.0.0 down to v4.5.0.0 after installation of CoDeSys. Same as you did. I hope this gets fixed on a next patch.
Last updated: 2025-11-21
Post by timvh on KeyPad Function in Visualization to fill a table
CODESYS Forge
talk
(Post)
Create an array of STRING and 1 INT variable, e.g.: asMyString : ARRAY[0..9] OF STRING; iIndex : INT; Then place a "Table" object in the visualization: - link this to the string array variable. - Check the option "Use Template" - Then in the Input Configuration - add the "Write Variable" command Somewhere else add a "Combobox, array" - link this to the same array. - And link the index to the INT variable. In the Combobox, you can then select one of the strings from the array. The index variable will indicate which selection has been made.
Last updated: 2026-01-08
Post by sulzbrunn on Codeys Installation freezes while attempting to install packages
CODESYS Forge
talk
(Post)
Hi, I am facing the same problem: I am trying to install CODESYS 3.5.17.60 The last log entries are: ... InstallShield 14:18:17: Done Initializing... InstallShield 14:18:17: Registering Msi Server... InstallShield 14:18:17: Invoking script function InstallOEMPackages 1: [CDS Info]: CDS_OEMPACKCOUNT: 47 1: [CDS Info]: CDS_OEMPACKCOUNTALL: 47 Action 14:18:17: CDSInstallOEMPackages. Install all Packages added to the setup 1: [CDS Info]: Call: C:\PROGRA~2\CODESY~1.60\CODESYS\Common\PACKAG~2.EXE --profile="CODESYS V3.5 SP17 Patch 6" --installAll="C:\Users\UserXXX\AppData\Local\Temp{94C03~1\Packages"
Last updated: 2026-03-19
Post by programmierer on UDB Block in Codesys V2.3 implementieren um Werte an bestimmte IP-Adresse zu senden
CODESYS Forge
talk
(Post)
Hallo zusammen, ich möchte mich hiermit an euch wenden, in der Hoffnung, dass ihr mir bei meinem Problem behilflich sein könnt. Ich bin neu in der Programmierung und arbeite aktuell mit einem Wago Controller in unserem Labor, der eine Wärmepumpe steuert. Mein Ziel ist es, vier spezifische Werte an eine bestimmte IP-Adresse zu senden. Dazu habe ich versucht, in das vorhandene CODESYS-Programm der Wärmepumpe zusätzliche UDP-Blöcke einzufügen, um die Datenübertragung zu ermöglichen. Leider hat das Senden der Daten bis jetzt nicht funktioniert. Ich habe auch Bilder der Blockkonfiguration beigefügt, um einen besseren Einblick in den Aufbau zu geben. Über jegliche Hilfestellung würde ich mich sehr freuen. Vielen Dank im Voraus!
Last updated: 2024-07-19
Post by andrebrandt on FB string and naming
CODESYS Forge
talk
(Post)
Hi Tim. Not quite correct. What i'd like, is when you place the FB in prog, i choose a block NTC10k, and name this RT401. What i'm trying to do, is to get the name RT401 automaticly into the FB, so i can put this into the string i pass in a struct. So in var in POU, i saw this a place i could do this, RT401: NTC10k(Tag:='RT401'), but i can't get this to work. I shurly must have had something like this in FB: FUNCTION_BLOCK NTC10k String TAG But it's here where I'm stuck...
Last updated: 2024-09-30
Post by ben1 on Help understanding analog in-/outputs
CODESYS Forge
talk
(Post)
Hi there mate Most PLC's have a very similar concept with AI/AO - have you used any other software before? I have not used a Wago before myself, but I assume the concept would very much be: 1. Add the analog in & out cards to your hardware config. 2. Setup the raw input scaling on the hardware (eg. 4 - 20mA = 4000 - 20000) 3. Use a built in or homemade scaling block to scale your input as needed (eg. 4000 - 20000 = -100 - 2000kPa. 4. Write code as required 5. Scale output as needed (eg. 0 - 100% = 0-10000 = 0 - 10V) Is this the information you require?
Last updated: 2024-12-15
Post by peterkcontrols on Copying 2 byte word to output
CODESYS Forge
talk
(Post)
Hello. I am using codesys 3.5. I would like to know if it is possible to set a variable to an output without declaring in. I have defined a STRUCT and within this struct I have a Struct for inputs called I and a struct for outputs called O. I have declared a variable of the type of this Struct, I would like to set or alias the value in this variable to an input/output value of an IO block that has a module on the ethernet tree. Is it possible to copy the contents of %IW0 -> STRUCT.I ? The size of both of these is 2 bytes. I understand that I can declare a variable with the input like Input01 AT %IX0.0 : BOOL; However how can I make STRUCT.I.D00 AT %IX0.0? Is this possible? Thanks
Last updated: 2025-03-03
Post by amy123 on codesys mqtt publish serialization
CODESYS Forge
talk
(Post)
Hello, I am using the CODESYS IIoT Libraries SL MQTT Publish. Does this publish block only support publishing STRINGS as a readable format? I can publish ENUM, STRUCT, BOOL; however, MQTT Explorer will only display strings. When I use Wireshark, I can see that it is publishing something, but it looks to be publishing a serialized version which is a bunch of 0s or random text. If so, is there any way to deserialize this information back into a readable format? See pictures, where I have a BOOL TRUE that gets published as 001. Then see where I publish a STRUCT and it's an incomprehensible combination of 0s - only the string variable is displayed. Or, is it expected that you convert everything to a string before publishing? Any help is greatly appreciated! :)
Last updated: 2024-02-16
Post by esave on OPC UA Server with on Codesys + OPC UA Client on Labview
CODESYS Forge
talk
(Post)
Hello everyone I want a communication between my PLC as an OPC UA Server and Labview on my PC as the OPC UA Client. I have an Festo CPX-E-CEC-C1-PN PLC and I have the OPC UA Toolkit from Labview. I created some Variables for testing (see picture 1) on Codesys. I tried to use this Labview block diagram (see picture 2) but I cant connect the PLC to it. What do I have to type in the Server Endpoint URL and what in the Node ID? Is this a good way for communication with a PLC to a PC? If not is there another way?
Last updated: 2024-04-12