Search talk: Error Handling

 
<< < 1 .. 32 33 34 35 36 .. 42 > >> (Page 34 of 42)

Post by eschwellinger on New Ladder Diagram conversion does not work due to missing features CODESYS Forge talk (Post)
The "remove unused" parameters have been added to 1.0 version as well as the "manual" removal of pins... also allowed "empty" inputs for blocks is in and the compile error described there should no longer occurs. Drag drop of variables is not yet implemented and I don't think the double-click feature yet either.
Last updated: 2024-01-29

Post by mondinmr on Why SysPipeWindows is not implemented in RTE? CODESYS Forge talk (Post)
This library would be very useful for IPC communications. Using a UDP socket on localhost is unpredictable, as with slightly loaded machines it does not even guarantee packet delivery locally. Using TCP creates a lot of overhead. Message named pipes would be an excellent solution for Windows RTE. On Linux, since the release of the extension package, there is no issue, as it is sufficient to develop a component. However, although now 90% of our clients understand that Linux runtimes are better in every way compared to Windows RTE, especially from the security aspect (Not in kernel space) and the issues with Windows updates, 10% stubbornly insist (sometimes for trivial commercial reasons) on using Windows. Managing IPC with circular buffers in shared memory is quite ugly, or rather really ugly and unaesthetic. In the manuals, I saw the SysPipeWindows libraries, so I decided to test them, but unfortunately, I noticed that they are not implemented for RTE devices. Technically, I could try to open them as regular files, but SysFileOpen returns 16#27 or 16#39 depending on how I set the name (direction of the slashes). Here is the code to create shared memory and named pipes. Shared memory work great, named pipes no! #ifdef Q_OS_WIN32 SECURITY_ATTRIBUTES sa; SECURITY_DESCRIPTOR sd; InitializeSecurityDescriptor(&sd, SECURITY_DESCRIPTOR_REVISION); SetSecurityDescriptorDacl(&sd, TRUE, NULL, FALSE); sa.nLength = sizeof(SECURITY_ATTRIBUTES); sa.lpSecurityDescriptor = &sd; sa.bInheritHandle = FALSE; const wchar_t* name = L"Global\\ShmTest"; HANDLE hMapFile = CreateFileMapping( INVALID_HANDLE_VALUE, NULL, PAGE_READWRITE, 0, sizeof(SharedData), name); if (hMapFile == NULL) { qCritical("Error creating shared memory"); return 1; } data = static_cast<SharedData*>(MapViewOfFile(hMapFile, FILE_MAP_ALL_ACCESS, 0, 0, sizeof(SharedData))); if (data == NULL) { qCritical("Error mapping shared memory"); return 1; } HANDLE hPipe = CreateNamedPipe( TEXT("\\\\.\\pipe\\MyPipe"), PIPE_ACCESS_DUPLEX, PIPE_TYPE_MESSAGE | PIPE_READMODE_MESSAGE | PIPE_WAIT, PIPE_UNLIMITED_INSTANCES, 1024 * 1024, 1024 * 1024, NMPWAIT_USE_DEFAULT_WAIT, &sa); if (hPipe == INVALID_HANDLE_VALUE) { qCritical("Error creating named pipe"); return -1; } if (!ConnectNamedPipe(hPipe, NULL)) { qCritical("Error connecting to named pipe"); return -1; } checkPipe(hPipe); #endif
Last updated: 2024-02-02

Post by nano on Modbus TCP/IP slave communication errow CODESYS Forge talk (Post)
please tell us the exact error message from diagnostic. U can view it at devicetree in the node-element diagnostic from modbus-configuration. u also can activate the function auto-reconnect in master and increase a little bit the timeout and the repetition to male thw communication a little bit more robust
Last updated: 2024-02-04

Post by davidbo on i2c How does CODESYS handle exception or error messages. CODESYS Forge talk (Post)
For Raspberry Pi I have made a python script which regularly read a bulk of data over the ic2 from a device. Sometimes I get an Exception an IOError. I assume similar things can happen in CODESYS. So how does CODESYS handle that? Can I get any info about such an event?
Last updated: 2024-02-07

Post by fredsta on Unable to load dynamic modules (Download failed: Application=Application) CODESYS Forge talk (Post)
I'll have a look at this, thanks. Do you maybe know why the C-integration doesn't work? I'm just curious because it was still some effort to create all these files. Ending up with a meaningless error feels very unsatisfying to me...
Last updated: 2024-02-19

Post by reinier-geers on SysFileOpen does not work after update to V3.5 SP19 Patch 5 CODESYS Forge talk (Post)
At 19.1 the hFile_test should be RTS_IEC_HANDLE and always open-write - close in one cycle udi_handle: RTS_IEC_HANDLE; //handle-number. Is created by SysFileOpen udi_handle:=SysFileOpen(sFileName,Sysfile.AM_WRITE_PLUS, ADR(udi_ErrorCode)); udi_RetValWrite:=SysFileWrite(udi_handle, pRemBuffer, szRemBufSize, ADR(udi_ErrorCode)); //closing file IF udi_RetValWrite < szRemBufSize THEN ui_Error:=cWriteError; END_IF//error writing data udi_ErrorCode_Close:=SysFileClose(udi_handle);
Last updated: 2024-02-19

Post by jmauer on Codesys 3.5 SP16 Modbus change port settings. CODESYS Forge talk (Post)
Hello, I'm coming to you today because I'm trying to make the baudrate and the slave number dynamic. I've tried the "updateComPortSettings" method on the slave device but it doesn't work and gives the "Modbus_COM_Port" an error. Can you tell me how you got this method to work? Thanks in advance for your help jΓ©rΓ©my
Last updated: 2024-02-20

Post by alexgooi on Init Array input on a method CODESYS Forge talk (Post)
Dear Forum, I would like to initialize an array input on a method. When I do this, I get the following error: "The type of ARRAY [1..2] OF BOOL cannot have a default value in this context." I attached a picture for more clarity. Is this simply not possible or is there a different way of tackling this problem? Thank you in advance
Last updated: 2024-02-26

Post by andbat on CODESYS 4 Linux: CODESYS Forge talk (Post)
Good morning @mondinmr, I'm trying to install codesys 3.5.20.0 inside bottles (with wine 9.2). The full installation seems to be done (exept CodeMeter). When I run Codesys IDE an error related to IPMCLI appear and there is non chanse to open the IDE. How did you solve this issue? Thanks a lot.
Last updated: 2024-03-20

Post by nano on Error building Extension SDK Linux code CODESYS Forge talk (Post)
Hey schnepper, when i look into your c-file, i would say that only the main-function is declared with cext-addendum in your codesys-library-project. all yΓΆur funtions in library has to be the cext-addendum when the external implementation is activ. if i remeber right, methods and other subelements dont need that, but every base-elements
Last updated: 2024-04-02

Post by vincentd on Datasource OPC UA Client error ID:7012 CODESYS Forge talk (Post)
I have not used this client / server OPC UA combination since. We were only making some kind of proof of concept. I did understand that there could be some kind of bug. I do not know if the supposed bug has been resoved since. Perhaps you could try what piautomation is suggesting
Last updated: 2024-04-05

Post by saugat10 on I have errors while building the project CODESYS Forge talk (Post)
I have some errors as you can see in the picture when i build the project. I have not been able to trace back to the error and i have no idea where to look at to fix this issue. What is GVL_Io? Is it related to some library?
Last updated: 2024-04-10

Post by installwhat on raspistepper error after install CODESYS Forge talk (Post)
from another post on this forum .... In your library project select Project -> Project Information. On the Properties table remove the "LanguageModelAttribute" Value "Qualified Access Only". This will allow you to access the object without qualifying the access. ...... I guess they've compiled it the library with that setting and now I need to mess around with versions.
Last updated: 2024-04-20

Post by bryandimino on OPC Da Server Code Meter Issues after Enabling License CODESYS Forge talk (Post)
I'm trying to get the OPC server setup on my machine and currently I'm not having luck. I went ahead and got my license setup. However when I go to run WinCoDeSysOPC.exe I get an error message that I don't have the code meter licenses installed. Does anyone have any ideas on how I can fix this issue?
Last updated: 2024-05-02

Post by rajesh008 on i can't declear the address in GVL - codesys SP19 Patch5 CODESYS Forge talk (Post)
The β€œ_AB AT %IW0:word; ” if i called the value then im getting this error. like below "the declartion of the variable with an address assignment cannot be used in a PRG or GVL with the attribute 'subsequent'" This is happening when the GVL is selected in Redundancy Configuration. if i un-select the address declaration is working fine
Last updated: 2024-05-13

Post by kuegerls on CSV Utility SL CODESYS Forge talk (Post)
Hello, I want to read a CSV file using the CSV Utility SL library, but I encounter an 'invalid_handle' error during initialization. What could be the cause? For my test program see the screenshot. I have purchased a license, and it is also installed on my PLC. Thank you in advance. Best regards, Stefan.
Last updated: 2024-05-13

Post by walkercope on Ethercat bus on Beckhoff CX with Codesys for Linux CODESYS Forge talk (Post)
Has anyone figured out a way to use the ethercat bus on a beckhoff CX using codesys running on linux? Using ethercat on the native NICs works fine but I get a "packet could not be sent" error when trying to scan the ethercat bus device. Errors and hardware in attached image.
Last updated: 2024-05-13

Post by matthew on Persistence Manager Backup CODESYS Forge talk (Post)
Hi @eschwellinger yes I have been using xDoubleStorage It happened again and I checked and the files were still there with there contents, restarting codesys or rebooting would not even reload them. Doing a download and then starting the PLC loaded them and began working again. Some sort of mismatch error or something?
Last updated: 2024-05-14

Post by schnepper on How to delete main action from SFC Step CODESYS Forge talk (Post)
I added a main action to an SFC step, and then tried to delete it. There is no delete option in the SFC menu nor in the right click menu of the step. I deleted the action from the device tree, but building results in and error saying the action is not defined. Is there a way to delete a main action?
Last updated: 2024-05-23

Post by totorovic on IO-LINK Package - new license model CODESYS Forge talk (Post)
Hello, I'm using th IDE Combivis studio 6 (codesys based) and I get an error message when I use IO-link. "The license is missing or invalid. The API is running in demo mode." However the package Manager indicates that no licence is required. It used to work, it seems that the free package has become a paying one. Can Codeys confirm this? BR
Last updated: 2024-06-06

Post by pharus on Setup problems with PiXtend CODESYS Forge talk (Post)
Hello all, I have an PiXtend V2L complete kit and installed everything like in the manual. Ive installed Codesys V3.5 S20 Codesys Control for Raspberry Pi PiXtend_V2_Professional_for_CODESYS.package But as soon as i Create a Project, i get a lot of error messages, and i cant find the PLC via Ethernet Thanks a lot
Last updated: 2024-06-19

Post by pharus on Setup problems with PiXtend CODESYS Forge talk (Post)
Hello all, I have an PiXtend V2L complete kit and installed everything like in the manual. Ive installed Codesys V3.5 S20 Codesys Control for Raspberry Pi PiXtend_V2_Professional_for_CODESYS.package But as soon as i Create a Project, i get a lot of error messages, and i cant find the PLC via Ethernet Thanks a lot
Last updated: 2024-06-19

Post by pharus on Setup problems with PiXtend CODESYS Forge talk (Post)
Hello all, I have an PiXtend V2L complete kit and installed everything like in the manual. Ive installed Codesys V3.5 S20 Codesys Control for Raspberry Pi PiXtend_V2_Professional_for_CODESYS.package But as soon as i Create a Project, i get a lot of error messages, and i cant find the PLC via Ethernet Thanks a lot
Last updated: 2024-06-19

Post by pharus on Setup problems with PiXtend CODESYS Forge talk (Post)
Hello all, I have an PiXtend V2L complete kit and installed everything like in the manual. Ive installed Codesys V3.5 S20 Codesys Control for Raspberry Pi PiXtend_V2_Professional_for_CODESYS.package But as soon as i Create a Project, i get a lot of error messages, and i cant find the PLC via Ethernet Thanks a lot
Last updated: 2024-06-19

Post by rikher on Error: Too few outputs exixts for the box 'MemCopy' (minimum is 1). CODESYS Forge talk (Post)
I am using MemCopy Function for this example: https://www.youtube.com/watch?v=DeTCT5Vyn28&t=482s It is from library WagoSysPlainMem. I want to use this for an MQTT example. However, Codesys is complaining the block does not have outputs. How to fix this?
Last updated: 2024-06-19

<< < 1 .. 32 33 34 35 36 .. 42 > >> (Page 34 of 42)

Showing results of 1034