Search talk: file access open

 
<< < 1 .. 32 33 34 35 36 .. 50 > >> (Page 34 of 50)

Post by aliazzz on Unable to deploy Virtual Control SL on ARM64 (Raspberry Pi5) CODESYS Forge talk (Post)
Hi, I have successfully deployed "Virtual Control SL" on a few x86/64 machines now. However, I'd now like to deploy this to a Raspberry Pi (ARM64). To do this I prepared the Raspberry Pi5 with the following prereq's; * Minimal PREEMPT Debian * Latest Bootfirmware * full SSH access via non-root account * Podman * RedHat Cockpit with CODESYS LicensServer plugin up and running However, I can't seem to resolve copying the correct (deploy) Images as they wont show up in the CODESYS IDE I have added CODESYS Virtual Control for Linux SL and the CODESYS LicenseServer for Linux SL via the CODESYS installer on my DevBox. I open CODESYS > Tools > Deploy Control SL Next I enter the SSH targets IP and Credentials and for my RPi5 and it shows "Connected". In the next tab, Deployment, the dropdown box only shows one (1) image, which also is the incorrect CPU architecture. Only Virtual Control AMDx64 shows up (!?) while I expect to see the ARM64 based images for both Edge and Control. Has someone encountered this too? I'd like to hear other people experiences with Virtual Control deployment on ARM based architecture. attachment 1: AMD64 based deployment pulldown menu (correct images) attachment 2: ARM64 based deployment pulldown menu (incorrect images) regards,
Last updated: 2024-07-28

Post by timvh on When Keyboard Key is in Hold, then Webvisu is extreme slow and latent CODESYS Forge talk (Post)
I'm not really sure what you are trying to do, but maybe you are referring to using the CmpCharDevice library? When you "open" the connection to a device, you can pass flags. What helped me is to set the non-blocking flag. I'm not sure if this is what you are referring to, but maybe it helps: dFlags: DINT := CmpCharDevice.ACCESS_MODE.O_RDONLY + DINT#4000; // see details for flags: http://linux.die.net/man/2/open, + DINT#4000 is for non-blocking hDevice := CmpCharDevice.CDOpen(szFilename, dFlags, Result);
Last updated: 2023-09-20

Post by codesysjupiter on Could not be resolved - Library error CODESYS Forge talk (Post)
Hello, everyone. How are you? Please help me with my library error. When I open the CODESyS project, the error message is Could not open library “#loDrvEthernet. (Reason: The placeholder library ToDrvethemet’ could not be resolved.) I tried to find solution to fix this . and the help teach me to run this command "Update placeholder <iodrvethernet> to the newest version:" Is this right ? But I couldn't find where I input this command and how to run it. Or any other solution , please ?</iodrvethernet>
Last updated: 2024-04-12

Post by codesysjupiter on Library Error CODESYS Forge talk (Post)
Hello, everyone. How are you? Please help me with my library error. When I open the CODESyS project, the error message is Could not open library “#loDrvEthernet. (Reason: The placeholder library ToDrvethemet’ could not be resolved.) I tried to find solution to fix this . and the help teach me to run this command "Update placeholder <iodrvethernet> to the newest version:" Is this right ? But I couldn't find where I input this command and how to run it. Or any other solution , please ?</iodrvethernet>
Last updated: 2024-04-12

Post by pppn on Issue with Forward Open Connections in Ethernet/IP Protocol Stack in Codesys CODESYS Forge talk (Post)
Hello, I am facing an issue with my Ethernet-based project in Codesys. My product was functioning well until I modified the protocol stack and uploaded it to my device. Here are the details of my problem: Project Setup: I am working on an Ethernet-based project to test my product. The project was running without issues before modifying the protocol stack. Issue: After modifying the protocol stack and uploading it to my device, I am encountering an error in Codesys related to the forward open connections. Error status: connection failure, extended: connection in use or duplicate forward open. According to the Ethernet/IP protocol in codesys, there are three forward open connections that need to be established. The first two connections are opening without any issues. The third connection, which is an input-only connection, is causing problems. The error message indicates that the connection is already open. Debugging Attempts: I have extensively debugged the protocol stack and found no issues. The product works well when tested with EIP tools but not with Codesys. Exclusive owner connections are working correctly, and only the input-only connection is problematic. Wireshark Traces: Wireshark traces show that the third connection attempts to open but reports that it is already open. Steps to Reproduce: Modify the protocol stack and upload it to the device. Attempt to establish three forward open connections in Codesys. Observe the error on the third connection (input-only). Request: I would appreciate any suggestions or guidance on how to resolve this issue. If there are specific settings or configurations in Codesys that I need to check, please let me know. Additionally, if there are known issues or workarounds related to this problem, I would be grateful for the information. Attachments: Wireshark traces showing the connection attempts and errors Screenshots of the error messages in Codesys codesys version: CODESYS V3.5 SP16 Patch 3 + 64 bit
Last updated: 2024-06-25

Post by pppn on Issue with Forward Open Connections in Ethernet/IP Protocol Stack in Codesys CODESYS Forge talk (Post)
Hello, I am facing an issue with my Ethernet-based project in Codesys. My product was functioning well until I modified the protocol stack and uploaded it to my device. Here are the details of my problem: Project Setup: I am working on an Ethernet-based project to test my product. The project was running without issues before modifying the protocol stack. Issue: After modifying the protocol stack and uploading it to my device, I am encountering an error in Codesys related to the forward open connections. Error status: connection failure, extended: connection in use or duplicate forward open. According to the Ethernet/IP protocol, there are three forward open connections that need to be established. The first two connections are opening without any issues. The third connection, which is an input-only connection, is causing problems. The error message indicates that the connection is already open. Debugging Attempts: I have extensively debugged the protocol stack and found no issues. The product works well when tested with EIP tools but not with Codesys. Exclusive owner connections are working correctly, and only the input-only connection is problematic. Wireshark Traces: Wireshark traces show that the third connection attempts to open but reports that it is already open. Steps to Reproduce: Modify the protocol stack and upload it to the device. Attempt to establish three forward open connections in Codesys. Observe the error on the third connection (input-only). Request: I would appreciate any suggestions or guidance on how to resolve this issue. If there are specific settings or configurations in Codesys that I need to check, please let me know. Additionally, if there are known issues or workarounds related to this problem, I would be grateful for the information. Attachments: Wireshark traces showing the connection attempts and errors Screenshots of the error messages in Codesys codesys version: CODESYS V3.5 SP16 Patch 3 + 64 bit
Last updated: 2024-06-25

Post by timvh on No source code available for this object CODESYS Forge talk (Post)
The message means that you (CODESYS) tries to open the function block, but this is not possible because the library which contains the FB is compiled. You either get this when you try to manually open the function block (while editing the application), but it could also happen that an exception occurs in the running application and CODESYS tries to show the location where it occured. If it happened in an FB of the compiled library, it cannot show this and you could get this message too.
Last updated: 2024-07-16

Post by rmaas on Webvisu cliënt responsiveness CODESYS Forge talk (Post)
hi, Does anyone know how to optimise the responisiveness of the web visualisation? When i open the webvisu on my laptop it is very responsive, no noticable lag. But when i open it on the HMI (web client) at the customer site there is a lag of +-500 when opening popups etc. The hmi used is: Phoenix Contact WP 6156-WHPS full hd Arm® Cortex®-A53, 1.6 GHz qt web browser The clients performance seems to be the problem, what can i do in my project to decrease the load for the client?
Last updated: 2024-09-28

Post by cillian on Error when opening HTML5Control Editor CODESYS Forge talk (Post)
Hello, I am new to this forum so apologies if this is posted in the incorrect area. I am getting an error when trying to open the HTML5 Control Editor - this was working fine previous days. I am using Codesys V3.5 SP20 Patch 3. I have reinstalled the application. Below is a screenshot of what shows when I attempt to open HTML5 Control Editor. Would anyone know the solution to rectifying this problem? Thanks in advance. Edit: This is now fixed.
Last updated: 2024-10-22

Post by rossanoparis on After un upgrade of "CODESYS Control for Raspberry Pi MC SL" from v4.7 to v4.9 SysFileOpen function stopped working CODESYS Forge talk (Post)
Hello at all. After un upgrade of "CODESYS Control for Raspberry Pi MC SL" from v4.7 to v4.9 SysFileOpen function stopped working. I'm not able to read or write files from the PLC application. Before this upgrade all worked fine. I've read this thread [ https://forge.codesys.com/forge/talk/Engineering/thread/3da9ded84e/ ] Despite I followed that indications I couldn't get my code working again. Perhaps I'm missing something or I didn't understand how to use placeholders at all. Is there a different syntax to use for "SysFileOpen" in order to use placeholders? Thanks in advance for your help. Information Compiler: CODESYS V3.5 SP19 Patch 2 Runtime: codesyscontrol 4.9.0 HW: KUNBUS RevPi Connect S Below the paths I want to access (The entire CODESYSControl_User.cfg file is attached) [SysFile] PlaceholderFilePath.1=/home/pi/hpca/bin, $hpcabin$ PlaceholderFilePath.2=/home/pi/hpca/cfg, $hpcacfg$ PlaceholderFilePath.3=/home/pi/hpca/logs, $hpcalogs$ PlaceholderFilePath.4=/home/pi/hpca/resources, $hpcares$
Last updated: 2023-08-22

Post by trusty-squire on CNC - How to manipulate SMC_GeoInfo objects CODESYS Forge talk (Post)
I have an application using CNC GCode interpolation, but I need to modify the GCode provided to the PLC based on certain parameters. I am currently attempting to modify the SMC_GeoInfo objects in the SMC_OutQueue using the code below. Note that all the other code is pretty standard and works fine, but when I add the below it errors. PROGRAM TEST VAR fbReadCncFile : SMC_ReadNCFile2; fbCncInterpreter : SMC_NCInterpreter; arrCncInterpreter : ARRAY[1..99] OF SMC_GeoInfo; pGeoInfo: POINTER TO SMC_GeoInfo; giGeoInfo: SMC_GeoInfo; // ... END_VAR // ... Some code here in order to read CNC file using SMC_ReadNCFile2 and provide to SMC_NCInterpreter pGeoInfo := SMC_GetObj(poq:=ADR(fbCncInterpreter.poqDataOut), n:=1); IF pGeoInfo <> 0 THEN giGeoInfo := pGeoInfo^; // Do some manipulation here, then update the queue at the same position MC_SetObj(poq:=ADR(fbCncInterpreter.poqDataOut) , n:=0 , pgi:=ADR(giGeoInfo) ); END_IF It throws an error when I get to the line giGeoInfo := pGeoInfo^; Error: EXCEPTION [AccessViolation] occured: App=[Sim.Device.Application], Task=[PathTask] How do I use SMC_GetObj and access the data? It creates a pointer with the value as shown in the photo, but all the dereferenced values say dereference of invalid pointer.
Last updated: 2024-07-26

Post by jmfernandes on OpenDir always in error CODESYS Forge talk (Post)
Hello I'm trying to use DirOpen to access a directory where then I can read/list the files inside. But I can't list any files because DirOpen.xError is always true. In eError the message is this: " ERROR_UNKNOWN Local library error ID (0: no error; 5101: time out)**** " I have in the file explorer the path 'C:\CodesysTest\Aluminium' and to make sure I also created in the plc a folder to 'prj/Recipes/Aluminium'. I tried using the different paths, but in both it happens the same thing.Inside the folder Aluminium there is two csv files, that I want to list. I added in the library manager CAA Files and CAA Types. I am using the example of https://content.helpme-codesys.com/en/libs/CAA%20File/Current/Examples.html#directory but not matter what I do, I can't get the list the names of the files. What am I missing?
Last updated: 2024-07-31

Post by bjarne-pagaard on Communication between applications on same device/controller/runtime (Win RTE 3.5.20.20) CODESYS Forge talk (Post)
Hi, I would like to divide a project into multiple applications - as a minimum: one handling visualization and Alarm Manager, one handling I/O and plant control logic. But how to exchange variables between the applications? What have you done to get such a solution? In versions 3.5.19 and earlier, you can have Child applications, where the children can access a GVL in the Parent application. Children apps is no longer possible in 3.5.20 - but you can have 'sibling' apps - Several apps directly under PLC Logic, that is. But how do they best communicate? The Communication Manager / Data Sources Manager is sort of possible via OPC UA, but it seems like overkill and with some limitations - for example no ARRAY OF STRUCT possible this way. If you have separate devices in your project, you can exchange data via 'CODESYS ApplicationV3', but not other applications in the same device (see attachment Datasources.png). You can do it via 'Select the project type'->'Other Project' and select the same project file, but this leads to crashing the Development system when working with the variables afterwards. It would be great to hear your thoughts / experiences on this topic - Bjarne
Last updated: 2024-09-27

Post by rabaggett on Reading Named Pipes in Linux Is there a better way? CODESYS Forge talk (Post)
I have a Python program that will handle things in my application such as VISA over IP and Telnet control of instruments. I want the main control and HMI in Codesys. My problem is communication between the two. I have looked at several ways to accomplish this, and settled on having the Python program create two named pipes, one to send information to Codesys, and one for Codesys to send information to Python. The information would be packetized with \n for end of packet.. Seems simple. I think the named pipes method should work, but file reading in Codesys using the CAA file library starts to get difficult when the file is never ending, as in this case. Before I spend too much time making something that may be fundamentally flawed I want to ask. Is there a better way? Is there a way to read the file 'one line at a time' which might solve my never ending file problem? Thanks!
Last updated: 2024-05-09

Post by sigurdrb on send appliaction files to wago plc (codesys 3.5) via ssh CODESYS Forge talk (Post)
Hi, I was hoping I could send the two files "application.app" and "application.crc" directly to the directory "/home/codesys/PlcLogic/Application" instead of logging into the device with codesys, downloading the program to the controller and then do the "create boot application", so it will reboot with the correct program running. I think i also need to edit the file "eRUNTIME.cfg" located in the "/home/codesys/ folder, because when I create the boot application from the codesys IDE, these lines are added to the file: [CmpApp] Application.1 = Application [SysFileMap] /home/codesys/PlcLogic/Application/Application.app=0x212520, 0x2DBC747E, 2DBC747E.app I think the "eRUNTIME.cfg" file is the same as CODESYSControl.cfg I also dont know the purpose of the hexadecimal numbers etc. that is generated. When I tried to replicate what codesys was doing, I placed the same files in the same folder as when codesys generated the boot file. And also added the lines in the eRUNTIME.cfg file: [CmpApp] Application.1 = Application [SysFileMap] /home/codesys/PlcLogic/Application/Application.app The controller did not boot up with any program, so my method did not work at all. I guess these lines tells the controller to run an application and where to find it? Could any of you help me with the best way to get the compiled program to the controller without using codesys or wago-software?
Last updated: 2024-05-28

Post by rkohser on Scripted Git clone / checkout being blocked by "Project Environment" popup CODESYS Forge talk (Post)
Hi, I am trying to build a CI/CD pipeline around our codesys projects. The only entry point if the git url and branch, as we do not put our project file under source control, so we needed to find a way to git clone from the python scripting engine. This is currently how we do this : system.commands["Git", "Clone"].execute( "ProjectLocation=" + project_dir, "ProjectName=" + project_file_name, "RemoteUrl=" + project_git_remote_url, "GitProjectStoragePath=" + project_git_local_dir, ) system.commands["Git", "Checkout", "Branch"].execute( "PrimaryProjectHandle=0", "BranchName=origin/" + project_git_branch ) This works fine, except that, depending on the environment and the project, the "Project Environment" popup gets displayed to suggest for some updates, and waits for a user interaction, even with the "--noUI" flag injected as parameter. I investigated the VersionUpdateFlags, but the problem is that the git clone is an atomic operation that clones and directly opens the generated project without the possibility to inject any updateFlags argument (only used in the ScripProjects.open() function. I also tried to simulate some keyboard events acknowledge the window from script but I did not find the right location for the SendKeys statement, I think before the git clone call is too early and after is too late. So I am wondering if there would be some other way to do that. Is there some more proper scripting api for the git add on ? Is there a global configuration of the VersionUpdateFlags that would allow the popup to be disabled outside from any project context ? Is there some way to automatically acknowledge this kind of messages in a "--noUI" mode ? What do you suggest ? Thanks for your help, Roland Edit : I managed to solve my problem by following these steps in my pipeline : - create a template of a project and opt file preconfigured not to open the popup - open this project - initialize an empty git repo - add the remote, fetch and checkout the needed branch -> no popup is displayed, hourra Edit2 : The initial question was raised on a CODESYS V3.5 SP18 Patch 2 profile. Since CODESYS 3.5.19.30 a scripting API is available for Codesys Git that allows cloning a project with the support of VersionUpdateFlags https://content.helpme-codesys.com/en/CODESYS%20Git/_git_using_scripting.html
Last updated: 2024-01-19

Post by eschwellinger on Same program to more than one PLC CODESYS Forge talk (Post)
just open http://localhost:8080 in Chromium then it will show the webvisu ( sure you need to this in your CODESYS Application)
Last updated: 2023-08-24

Post by marekxc on Error C0521 - unknow compiler CODESYS Forge talk (Post)
Select in tree "DEVICE", right-click and select "Update Device" Select "Library manager" and Change the version of the Library (down manualy). Samoetimes "Try reload Library". If you open a project version 3.5.19 in version 3.5.16, there are difficulties.
Last updated: 2023-09-02

Post by sedoerr on Check For Open Dialogs On Client CODESYS Forge talk (Post)
You need to create a function around this function to check the dialogs you use in your program. That's the way i have done it.
Last updated: 2023-09-26

Post by sedoerr on Check For Open Dialogs On Client CODESYS Forge talk (Post)
FUNCTION CheckDialogOpen : BOOL VAR_INPUT sDialogName : STRING; END_VAR VAR pstClientData : POINTER TO VisuElems.VisuStructClientData; itfDialogManager : VisuElems.IDialogManager; itfMyDialog : VisuElems.IVisualisationDialog; END_VAR VisuElems.g_ClientManager.BeginIteration(); WHILE (pstClientData := VisuElems.VisuElemBase.g_ClientManager.GetNextClient()) <> 0 DO itfDialogManager := VisuElems.g_VisuManager.GetDialogManager(); itfMyDialog := itfDialogManager.GetDialog(sDialogName); CheckDialogOpen := VisuDialogs.VisuDlgUtil_IsDialogOpen(itfMyDialog,pstClientData,itfDialogManager); IF CheckDialogOpen THEN EXIT; END_IF END_WHILE
Last updated: 2023-09-26

Post by gurke258 on EL2911 CODESYS Forge talk (Post)
Hello, sorry to open this again. I can't find the right ESI for EL1918 as Safety PLC.. I only have the one without safety PLC. I look on Beckhoff website but i didnt found it. Can anyone help me? EDIT: I found it :)
Last updated: 2023-10-12

Post by open on How to create a stopwatch? CODESYS Forge talk (Post)
Hi, how to create a stopwatch when start is pressed, timer will start counting and stop is pressed, timer will stop counting in structured text?
Last updated: 2023-12-07

Post by open on How to create a stopwatch? CODESYS Forge talk (Post)
Thanks everyone for your input, I am using persistent variables to retain the timer value after machine shutdown, and main task to be as low as possible for the seconds TON to be accurate.
Last updated: 2023-12-14

Post by lostcontrol on Using a USB barcode scanner with CoDeSys CODESYS Forge talk (Post)
Hi, Has anyone actually got this working? Is there any easy way to find the old forum files, as these links only open current projects..
Last updated: 2023-12-14

Post by awarginaire on Codesys state running automatically CODESYS Forge talk (Post)
Hello, I would like the PLC to open automatically in etat running. I have created a boot project but on startup the state is always stopped. What should I do?
Last updated: 2024-01-18

<< < 1 .. 32 33 34 35 36 .. 50 > >> (Page 34 of 50)

Showing results of 1246

Sort by relevance or date