Search talk: open dc_unusual_items2124310 file

 
<< < 1 .. 36 37 38 39 40 .. 45 > >> (Page 38 of 45)

Post by jshirazi on Restore license on Raspberry Pi CODESYS Forge talk (Post)
Hi, I recently got a license for Raspberry Pi, after license activation I made a backup copy of "CMLicenseNew.WibuCmRaU" file to a safe place. Things got complicated and I tried to downgrade OS for some reason after that I tried several times/ways to restore my license with no luck. the specifications are as follows: Raspberry Pi 4 Model B Rev 1.1 codesyscontrol 4.10.0.0 SDK 3.5.19.30 Logs: **** ERROR: CodeMWriteLicenseFile: 'CMLicenseNew.WibuCmRaU' failed: Container not found or Server dose not support .... So if someone know a solution for this please kindly help me. Regards
Last updated: 2024-02-03

Post by tk096 on SMC_Interpolator + SMC_controAxislbyPos CODESYS Forge talk (Post)
Hi, you can define a start position for your GCode. How the start position can be defined depends on the CompileMode: For File and SMC_CNC_REF: Set the start position input of SMC_NCInterpreter (https://content.helpme-codesys.com/en/libs/SM3_CNC/Current/SM_CNC_POUs/NC2/Interpreter/SMC_NCInterpreter.html) For SMC_OutQueue: * Right-click on the CNC object in the project tree * Select Properties * Select the tab 'CNC' * Set the start position Concerning your second question: If the new set position cannot be reached with the given velocity limit (AXIS_REF_SM3.fSWMaxVelocity), SMC_controlAxisByPos will report bStopIpo and close the 'gap' with the given gap dynamics (SMC_controlAxisByPos.fGap*).
Last updated: 2024-02-07

Post by thomasrohnerch on Color Change for Symbols not working CODESYS Forge talk (Post)
I have some Symbols from the Visualization Toolbox on my Target Visu on the Computer. I tried many Symbols, mainly Arrows. I'm able to control the visibility with condition e.g. "GVL.actual_testvalues.speed <= 0" But I can't do "Toggle color" with boolean GVL.b_toggle_color. Neither "TRUE" nor "FALSE" does change anything. Is this a known issue? I'm using CODESYS V3.5 SP19 Patch 5 + (64-bit). See attached file with more Version-Info. I'm currently using Style 6, Gradient axial 2, 3.5.12.0. I had the same issue with Default 3.5.16.0.
Last updated: 2024-02-08

Post by mimodia1 on I do not have any reedings in RUN MODE from MPU6050........ CODESYS Forge talk (Post)
Good morning, mecke96. Exactly the same thing happens to me, although I have not done the part of executing a .py file. It only reads the temperature and the counter, but the other values are zero as in your image "no readings". I have tested the MPU6050 device on an Arduino and it works. Could you tell me if you solved it?
Last updated: 2024-03-29

Post by esave on Stepper Drive with Ethercat CODESYS Forge talk (Post)
I bought and installed SoftMotion Light now. When I try to add a SoftMotion Light Axis to my stepper drive and I go online it shows: "The license is missing or invalid". See picture What am I doing wrong? This is the right way right? First add your EtherCat XML-File from your stepper driver and then add the SoftMotion Light axis right? Thanks for your help esave
Last updated: 2024-04-25

Post by gseidel on CNC - system goes to X=0 Y=0 before CNC file execution starts, how to avoid that? CODESYS Forge talk (Post)
Hi peterned, the start position given in the CNC properties is only used if you use the compile mode OutQueue. With compile mode SMC_CNC_REF, you need to provide the start position in the IEC application. The function block SMC_NCInterpreter has an input piStartPosition. You can initialize it with the output of the forward kinematic transormation FB for your machine. In your case probably SMC_TRAFOF_Gantry2. Best regards, Georg
Last updated: 2024-04-30

Post by rabaggett on CODESYS control for Raspberry Pi 64 SL errors CODESYS Forge talk (Post)
Update: I started over. I saved progress at each step. all compiled zero errors, zero warnings. Pre-processor messages remain, but I can make progress. Until I try to re- load the project file in Codesys. Re-loaded files error as above when compiled, even though they compiled error-free immediately before saving. Is my installation borked? (Not easy to re-install due to IT madness...)
Last updated: 2024-05-03

Post by william-blandon on RecipeManCommands.ReloadRecipes CODESYS Forge talk (Post)
Hello. I'm trying to use RecipeManCommands.ReloadRecipes Method for getting recipes from files. When I call the method it does not generate any error but also not reload any recipe to the recipe definition. Actually I have 6 recipe files on the directory PlcLogic. The rest of the methods work creating recipes, saving to file, etc. Does any one have the same issue? it is something to be set on the recipe manager?
Last updated: 2024-05-16

Post by wollvieh on License Activation Problems CODESYS Forge talk (Post)
on a raspberry pi delete the folder and its content before licensing. /var/opt/codesys/cmactlicense If you plug this SD card in another raspi ( which has another hw-serial number) you'll get a second empty softcontainer. This could lead to an unlicensed PFC (it could only handle one container) The solution is: To delete the /var/opt/codesys/cmactlicense directory and content of it and then aktivate the lizenz via WibuCmRau file and Lizenzmanager.
Last updated: 2024-06-24

Post by s1mon on Two OneWireMaster on one Raspberry PI 5 CODESYS Forge talk (Post)
All Sensors from the OneWire Master are assigned already to a seperate task with low prio (26) that runs with 1s cycle time. My EtherCat Task is running with Prio 1. It all works fine, until I adjust the CODESYScontrol.cfg or the CODESYScontrol_Usr.cfg files so that it supports a 2nd OneWire Master in the Codeys Runtime. If I change something in this config file and reboot my EtherCat Master stops working.
Last updated: 2025-10-19

Post by adam on Get/Set I/O Address Mapping of DeviceObjects in python Script CODESYS Forge talk (Post)
I want to cancel the automatic address allocation for all IO mappings. If I directly set the automatic_iec_address in class ScriptIoMapping to False, the address becomes None. So I reset manual_iec_address with itselfs value. It only work with the Input IOMapping . For output, it reports an error: "Invalid address: The channel type 'Output' requires address type '%Q'." I checked the description file ,both accessRight are total same. Does anyone know what causes this?
Last updated: 2025-11-14

Post by marciohogenelst on stablish CAN communication through the PC's USB port CODESYS Forge talk (Post)
I'm using Codesys v3.21SP4 on my PC via ControlWin to establish CAN communication through the PC's USB port. The software works fine. The CAN/USB converter works fine and is validated. However, there is no communication. Which folder and file should be modified to allow the CAN/USB converter to work and thus achieve the connection? Converter used: PCAN-View Information not yet processed: Access the folder: C:\Program Files (x86)\3S CODESYS\GatewayPLC\CODESYSControl.cfg Uncomment the line: Component.5=CmpPCANBasicDrv Any help would be appreciated.
Last updated: 2025-12-11

Post by marciohogenelst on stablish CAN communication through the PC's USB port CODESYS Forge talk (Post)
I'm using Codesys v3.21SP4 on my PC via ControlWin to establish CAN communication through the PC's USB port. The software works fine. The CAN/USB converter works fine and is validated. However, there is no communication. Which folder and file should be modified to allow the CAN/USB converter to work and thus achieve the connection? Converter used: PCAN-View Information not yet processed: Access the folder: C:\Program Files (x86)\3S CODESYS\GatewayPLC\CODESYSControl.cfg Uncomment the line: Component.5=CmpPCANBasicDrv Any help would be appreciated.
Last updated: 2025-12-11

Post by manuknecht on Persistence Manager does not save alphabetically first value CODESYS Forge talk (Post)
After some more digging I realized that I get an error on the PLC Logger saying PersistenceChannel: 150 (invalid type in data: SimpleLibrary). I suppose the issue could be found in the ConfigData, which is automatically generated and which looks like this: 1 9##83 SimpleLibrary#GVL.aMoreZeros.[1]#0#64512#15#0 <[2]#0#64520#15#0 <[3]#0#64528#15#0 <[4]#0#64536#15#0 <#0#64544#15#0 <[6]#0#64552#15#0 <<lrVar#0#64560#15#0 <strVar#0#64428#16#80 <uiDummy#0#64370#11#0 Perhaps the fact that the variable is stored within a library confused the compiler? I tried changing the PersistenceChannel parameters to xCompressTags := FALSE which changed the entry in the data file from _xCompressTags BOOL:TRUE _xCompressTags BOOL:FALSE but the actual content of the data file and also the config data did not change.
Last updated: 2023-10-17

Post by simone on Cannot connect to webvisu on localhost CODESYS Forge talk (Post)
As I wrote before on the title, I have difficulties to connect to see webvisu from localhost. The story: while waiting for the plc+hmi to arrive, I'm preparing the software, mainly the visual parts trough the control Win3 x64 (same version as the ide 3.5.20.10). The problem is that I can't see the webvisu with the installed webbrowser. I don't know if this is a problem, but I changed the port to 9001 (randomly "free") because 80, 8000, 8080, 8088, 3000 are all occupied by other projects (all on the Apache server). Is there something wrong with the config file? This is the url: localhost:9001/webvisu_app.htm and here the config file part "CmpWebServer". [CmpWebServer] ;The handling of startup/shutdown of the webserver: ;0->automatically start, shutdown only on shutdown of the runtime;1->automatically start, could be shutdown on demand ;2(default)->start/shutdown on demand;3->start on demand, shutdown only on shutdown of the runtime StartupType=0 ;The TCP port the webserver listens on WebServerPortNr=9001 LocalAddress=localhost ;LocalAdapterName=LAN-Connection LocalAdapterName=EthernetPCPLC ;LocalAdapterNameUnicode=L\00A\00N\00-\00C\00o\00n\00n\00e\00c\00t\00i\00o\00n\00 LocalAdapterNameUnicode=E\00t\00h\00e\00r\00n\00e\00t\00P\00C\00P\00L\00C\00 Thanks for all the help!
Last updated: 2024-07-11

Post by solve-it on SysFileOpenAsync CODESYS Forge talk (Post)
Just realized that it is the /dev/input/js0 file. Don't think this is a prob either. Found the ConfigFile. Where and how to add /dev/input/js0? raspberry [SysFile] FilePath.1=/etc/, 3S.dat PlcLogicPrefix=1 [SysTarget] TargetVersionMask=0 TargetVersionCompatibilityMask=0xFFFF0000 [CmpLog] Logger.0.Name=/tmp/codesyscontrol.log Logger.0.Filter=0x0000000F Logger.0.Enable=1 Logger.0.MaxEntries=1000 Logger.0.MaxFileSize=1000000 Logger.0.MaxFiles=1 Logger.0.Backend.0.ClassId=0x00000104 ;writes logger messages in a file Logger.0.Type=0x314 ;Set the timestamp to RTC [CmpSettings] FileReference.0=SysFileMap.cfg, SysFileMap FileReference.1=/etc/CODESYSControl_User.cfg [SysExcept] Linux.DisableFpuOverflowException=1 Linux.DisableFpuUnderflowException=1 Linux.DisableFpuInvalidOperationException=1 [CmpWebServer] ConnectionType=0 [CmpOpenSSL] WebServer.Cert=server.cer WebServer.PrivateKey=server.key WebServer.CipherList=HIGH [SysMem] Linux.Memlock=0 [CmpCodeMeter] InitLicenseFile.0=3SLicense.wbb [SysEthernet] Linux.ProtocolFilter=3 [CmpSchedule] ProcessorLoad.Enable=1 ProcessorLoad.Maximum=95 ProcessorLoad.Interval=5000 DisableOmittedCycleWatchdog=1 [CmpUserMgr] AsymmetricAuthKey=6873d655ac1f166f3743feea42d2f3dd1b39ae40 [CmpSecureChannel] CertificateHash=09fd8d52be4ddd45a709bc9c95e2aa093b3f5695 [SysSocket] Adapter.0.Name="eth0" Adapter.0.EnableSetIpMask=1 ;raspberry [ComponentManager] ;Component.1=CmpGateway ;Component.2=CmpGwCommDrvTcp ;Component.3=CmpGwCommDrvShm [SysCom] ;Linux.Devicefile=/dev/ttyS [CmpBlkDrvCom] ;Com.0.Name=MyCom ;Com.0.Baudrate=115200 ;Com.0.Port=3 ;Com.0.EnableAutoAddressing=1 [SysProcess] Command.0=shutdown [CmpApp] Bootproject.RetainMismatch.Init=1 ;Application.1=Application ;Application.1=Application ;Application.1=Application Application.1=Application [CmpRasPi] Architecture=armv6l [CmpRedundancyConnectionIP] [CmpRedundancy] [CmpSrv] [IoDrvEtherCAT]
Last updated: 2024-07-16

Post by dom4u on Using PEAK CAN PCIe card (IPEH-004040) with Codesys Control RTE V3 CODESYS Forge talk (Post)
Some findings on this issue: PEAK CAN Driver is the same as in every PCI card from PEAK. I updated the inf file. Here are my steps: 1. Include right VendorID into the *.inf file 2. Disable Windows driver check (Disable WHQL check). This you need because 3S driver is not certified. You will find steps via google or ask chatgpt :) 3. Select: Select driver from a list and navigate to the folder. Say yes to install an uncertified driver. 4. Driver installed and device without errors I did the same with CAN Card from ESD, but here you dont need to include the vendor ID. In ANY CASE it was not successful. The RTIOwdmgeneric is not available in Codesys or anyhow accassable :( I wonder that it fails in two cases, two suppliers, two driver in the same way. How can RTIOwdmgeneric implemented into the project?
Last updated: 2024-12-20

Post by pernockham on Persistence Manager: Config File not found? CODESYS Forge talk (Post)
Back in november I paused this, but wanted to reattempt using the persistent manager, the behavior is still the same. Most "login attempts" s are stopped with the message "One or more errors occurred" but I have no idea what that error might be. The only clue is this message is presented while the lower left status box says "Generating code...: relocation pou". For clarification. Build/Generate code is successful, no errors. Error appears when I try to download/login (physical or simulation) to a device. I did manage to login (in simulation mode) at one point, but then the error message "PersistenceChannel: Config file not found!". And no persistence files were created. I have done device-tree/reset-orgin also clean/clean all etc. Removed/re-inserted persistance manager. Behaviour is just the same. Removing Persistence Manage and everything is working OK. Is there possibly more info somewhere about the "One or more errors occured"-message?
Last updated: 2025-03-20

Post by laurits on Max lines of code, codesys CNC ? CODESYS Forge talk (Post)
Hi, okay here's the project, it's a modified version of "CNC Example 10: Programming Dynamic CNC Paths", no need for G Code text file (i have also tried with G code text file, same problem) in "PROGRAM PLC_PRG" you can set bStart to true, and the program should start running, go to "PROGRAM CNC" and you can see axis moving. lrXpos := IoConfig_Globals.XAixs.fSetPosition; lrYpos := IoConfig_Globals.YAxis.fSetPosition; Now you can can change the number of movements in the the "PROGRAM PLC_PRG" From this number of movements in "program PLC_PRG" BUF : ARRAY[0..32010] OF SMC_GEOINFO; xp : ARRAY[1..32000] OF REAL; yp : ARRAY[1..32000] OF REAL; to this number to this number of movements BUF : ARRAY[0..132010] OF SMC_GEOINFO; xp : ARRAY[1..132000] OF REAL; yp : ARRAY[1..132000] OF REAL; Now if you start the program again you should see an error in the "sMC_Interpolator: SM3_CNC.SMC_Interpolator;" function block Let me know if you can not get it running.
Last updated: 2025-06-03

Post by ranadheer on Codesys Control for PLCnext (PLC - AXL F 2152) CODESYS Forge talk (Post)
Hello Jaco Pretorius, I came across your post regarding CodeSys control for PLCnext. I’m currently working on a similar setup and had a quick question. Here am using the CODESYS V3.5 SP21 PATCH2 ,VERSION 3.5.21.20 , and Downloaded extension package 4.16.0.0 (old versions are not available in the extension CodeSys installer) Devices used here are: BUS COUPLER : 2403869 BK PN TPS Module carrier slot 1 : 1088127 AXL SE DI16/1 Module carrier slot 2 : 1088062 AXL SE AI4 | 4-20 Module carrier slot 3 : 1088129 AXL SE DO16/1 Module carrier slot 4 : 1088123 AXL SE AO4 | 4-20 -->Start a New Project Type: Standard Project Device: CODESYS Control Win V3 x64 Language: Structured Text -->Install GSDML File Navigate to: Tools > Device Repository > Install Select the GSDML file path (downloaded from Phoenix Contact for device coupler Part ID: BK PN TPS 2403869) Click Renew Device Repository Close the dialog -->Add Device to Project -->Right-click on Devices > Add Device Issue: Devices from the repository are not available to select or call into the project! I’d really appreciate any guidance or suggestions you can offer. Best Regards Ranadheer Reddy
Last updated: 2025-09-09

Post by ranadheer on Codesys Control for PLCnext (PLC - AXL F 2152) CODESYS Forge talk (Post)
Hello Jaco Pretorius, I came across your post regarding CodeSys control for PLCnext. I’m currently working on a similar setup and had a quick question. Here am using the CODESYS V3.5 SP21 PATCH2 ,VERSION 3.5.21.20 , and Downloaded extension package 4.16.0.0 (old versions are not available in the extension CodeSys installer) Devices used here are: BUS COUPLER : 2403869 BK PN TPS Module carrier slot 1 : 1088127 AXL SE DI16/1 Module carrier slot 2 : 1088062 AXL SE AI4 | 4-20 Module carrier slot 3 : 1088129 AXL SE DO16/1 Module carrier slot 4 : 1088123 AXL SE AO4 | 4-20 -->Start a New Project Type: Standard Project Device: CODESYS Control Win V3 x64 Language: Structured Text -->Install GSDML File Navigate to: Tools > Device Repository > Install Select the GSDML file path (downloaded from Phoenix Contact for device coupler Part ID: BK PN TPS 2403869) Click Renew Device Repository Close the dialog -->Add Device to Project -->Right-click on Devices > Add Device Issue: Devices from the repository are not available to select or call into the project! I’d really appreciate any guidance or suggestions you can offer. Best Regards Ranadheer Reddy
Last updated: 2025-09-09

Post by ranadheer on PHOENIX CONTACT Axioline PLCnext project in CodeSys SodftPLC CODESYS Forge talk (Post)
Hello Everyone, I'm working on a CODESYS Standard Project using CODESYS Control Win V3 x64 with Structured Text. The goal is to integrate a Phoenix Contact device coupler (Part ID: BK PN TPS 2403869) via PROFINET. Here am using the CODESYS V3.5 SP21 PATCH2 ,VERSION 3.5.21.20 , and Downloaded extension package 4.16.0.0 (old versions are not available in the extension CodeSys installer) Devices used here are: BUS COUPLER : 2403869 BK PN TPS Module carrier slot 1 : 1088127 AXL SE DI16/1 Module carrier slot 2 : 1088062 AXL SE AI4 | 4-20 Module carrier slot 3 : 1088129 AXL SE DO16/1 Module carrier slot 4 : 1088123 AXL SE AO4 | 4-20 -->Start a New Project Type: Standard Project Device: CODESYS Control Win V3 x64 Language: Structured Text -->Install GSDML File Navigate to: Tools > Device Repository > Install Select the GSDML file path (downloaded from Phoenix Contact for device coupler Part ID: BK PN TPS 2403869) Click Renew Device Repository Close the dialog -->Add Device to Project -->Right-click on Devices > Add Device Issue: Devices from the repository are not available to select or call into the project! I’d really appreciate any guidance or suggestions you can offer. Best Regards Ranadheer Reddy
Last updated: 2025-09-09

Post by edepalos on Text list from sd card CODESYS Forge talk (Post)
Hi guys, I have a textlist in my project which is working just as expected in a drop down list. I would like to move this text list to a sd card and access it from there, because I want to ease the editing of the contents of this textlist. I'm imagining a solution like the operator shuts down the plant, takes the sd card out, edits the textlist on the card with a windows machines notepad, then reinserts the card in the PLC and restarts the plant, having the new content of the textlist populating the dropdown list. I'm sorry that I'm asking you to spoonfeed me, but I did not find anything straightforward to do this... I saw in the Project>Project settings>Visualisation a relative path thingy, but I have the plant in operation and I would not like to make 100 trial and errors right now... I'm also not interested in SysLib file read commands and stuff, I would just like to access the file from the cards part, I don't want to replace its contents dynamically or such... nor I have language files or recipes... Thank You in advance! Br, Ede
Last updated: 2024-01-16

Post by umdee on Error when monitoring LAD programs CODESYS Forge talk (Post)
System Information from the computer being used: OS Name Microsoft Windows 11 Pro Version 10.0.22631 Build 22631 Other OS Description Not Available OS Manufacturer Microsoft Corporation System Manufacturer Dell Inc. System Model Latitude 5500 System Type x64-based PC System SKU 08B9 Processor Intel(R) Core(TM) i7-8665U CPU @ 1.90GHz, 2112 Mhz, 4 Core(s), 8 Logical Processor(s) BIOS Version/Date Dell Inc. 1.3.11, 6/11/2019 SMBIOS Version 3.2 Embedded Controller Version 255.255 BIOS Mode UEFI BaseBoard Manufacturer Dell Inc. BaseBoard Product 0M14W7 BaseBoard Version A00 Platform Role Mobile Secure Boot State On PCR7 Configuration Elevation Required to View Windows Directory C:\WINDOWS System Directory C:\WINDOWS\system32 Boot Device \Device\HarddiskVolume1 Locale United States Hardware Abstraction Layer Version = "10.0.22621.2506" User Name CARDASSIA-IX\Engineer Time Zone Eastern Daylight Time Installed Physical Memory (RAM) 16.0 GB Total Physical Memory 15.8 GB Available Physical Memory 4.67 GB Total Virtual Memory 18.5 GB Available Virtual Memory 2.52 GB Page File Space 2.63 GB Page File C:\pagefile.sys Kernel DMA Protection Off Virtualization-based security Not enabled Windows Defender Application Control policy Enforced Windows Defender Application Control user mode policy Off Device Encryption Support Elevation Required to View Hyper-V - VM Monitor Mode Extensions Yes Hyper-V - Second Level Address Translation Extensions Yes Hyper-V - Virtualization Enabled in Firmware Yes Hyper-V - Data Execution Protection Yes
Last updated: 2024-03-19

Post by wmoon on Licensing info not available. CODESYS Forge talk (Post)
That command can't excute on my device. I installed CODESYS into Hilscher's product using container Here is the Docker file what I used. I'm not sure if this docker file have a problem. If it have a problem, please let me know how to download the files into my device using ftp server. FROM arm64v8/debian:11.6 RUN apt-get update RUN apt-get install -y wget sudo unzip libusb-1.0-0-dev procps ENV CDS_VERSION "4.10.0.0" ENV EDGE_VERSION "4.10.0.0" ENV URL "https://store-archive.codesys.com/ftp_download/3S/LinuxARM64/2302000039/$CDS_VERSION/CODESYS%20Control%20for%20Linux%20ARM64%20SL%20$CDS_VERSION.package" ENV EDGE_URL "https://store-archive.codesys.com/ftp_download/3S/EdgeGatewayLinux/000120/$EDGE_VERSION/CODESYS%20Edge%20Gateway%20for%20Linux%20$EDGE_VERSION.package" RUN wget --output-document=/tmp/codesys.package $URL && \ unzip -p /tmp/codesys.package 'codemeter.deb' > /tmp/codemeter.deb && dpkg -i /tmp/codemeter.deb && \ unzip -p /tmp/codesys.package 'codesyscontrol.deb' > /tmp/codesys.deb && dpkg -i /tmp/codesys.deb RUN wget --output-document=/tmp/edge.package $EDGE_URL && \ unzip -p /tmp/edge.package '*arm64.deb' > /tmp/edge.deb && dpkg -i /tmp/edge.deb EXPOSE 11740 1217 11743 ENTRYPOINT ["/bin/sh", "-c" , "/etc/init.d/codesyscontrol start && /etc/init.d/codesysedge start && tail -f /dev/null"]
Last updated: 2024-03-20

<< < 1 .. 36 37 38 39 40 .. 45 > >> (Page 38 of 45)

Showing results of 1102

Sort by relevance or date