Post by nmcc on How to address visualization change with button press...
CODESYS Forge
talk
(Post)
Hello all, I am extremely new to Codesys and to programming with these languages in general. I have an HMI panel with 8 physical buttons to the right side of it. I am trying to have these set to change the visualization to a specific screen which I have designed 8 of. I currently have "use CurrentVisu" enabled in the visualization manager. I also have input blocks with all of the buttons being directed to output blocks which I want to have as the switcher for the visualization. Picture is attached for what I have currently. This could be the wrong approach to this issue. Any help is much appreciated.
Last updated: 2024-02-13
Post by wmoon on Licensing info not available.
CODESYS Forge
talk
(Post)
Hello, I bought some licenses from CODESYS store. I am trying to install licenses into my device(CODESYS Control for Linux ARM64 SL). But I have a trouble with it. I did it in the following order. Tool -> License Manager Selected Device and Next... Selected Soft container and Next... Select the device and Ok.. And then I always show a message "Licensing info not available. There is no dongle attached to the device." And I tried to click "Install Licenses" button. I saw the message "The value cannot be NULL. Parameter name : continerToLicenses" Could you let me know what I've missed or what I've got wrong?
Last updated: 2024-03-19
Post by superjojo2002 on Licensing info not available.
CODESYS Forge
talk
(Post)
If support for a containerized CODESYS runtime with a license isn't feasible, then I've considered an alternative approach: I've purchased and activated a "CODESYS Control Basic S" license on my Windows notebook, where I already have the Codemeter Control Center installed. Upon activation, I can see the CODESYS license as active on my notebook. Subsequently, I followed the instructions provided in this link (https://faq.codesys.com/display/CDSFAQ/How+to%3A+Setup+a+Wibu+Network+Server+Access+for+Licenses) to configure the Wibu runtime in the CODESYS container to access my external license server hosted on my notebook by editing the CODESYSControl_User.cfg file accordingly. However, it's worth noting that I'm still receiving a response from the Licensing Manager indicating that the runtime is persistently searching for a dongle instead of recognizing the soft container. So how can I get my runtime licensed now? Any ideas?
Last updated: 2024-03-20
Post by superjojo2002 on Licensing info not available.
CODESYS Forge
talk
(Post)
I recognized that I have to start the two services "/etc/init.d/codemeter" and "/etc/init.d/codemeter-webadmin" in the docker container as well. If I do so, then the command "cmu -x" returns root@sensoredge-field-netfield-produktmanagment:/# cmu -x cmu - CodeMeter Universal Support Tool. Version 7.60c of 2023-Aug-09 (Build 5625) for Linux/ARMHF 64-Bit Copyright (C) 2007-2023 by WIBU-SYSTEMS AG. All rights reserved. So this time there is no indication any more that "Codemeter is not running". But still we are getting the error when using the license manager in CODESYS development system.
Last updated: 2024-03-21
Post by wollvieh on Raspi Pi Bullseye Webvisu Autostart
CODESYS Forge
talk
(Post)
Anbei meine Lösung zum Autostart der Webvisu, vllt. hilft es jemandem... =============================== Raspberry Pi Bullseye 11 Autostart Codesys Webvisu im Kiosk Mode 1)Datei erstellen: sudo nano/etc/xdg/autostart/Visustart.desktop 2)Inhalt der Datei: [Desktop Entry] Type=Application Name=Visustart Exec=bash -c "sleep 30 && /home/pi/Desktop/Visu" 3)Visu Datei erstellen sudo nano /home/pi/Desktop/Visu 4) Inhalt der Datei: #!/bin/sh xset -dpms xset s off xset s noblank matchbox-window-manager -use_titlebar no & unclutter & chromium-browser -display=:0 --kiosk --incognito --window-positon=0,0 5) Datei ausführbar machen sudo chmod+x /home/pi/Desktop/Visu ... nach Neustart Raspi startet die Codesys Webvisu automatisch im Kiosk Mode ===============================
Last updated: 2024-03-24
Post by wollvieh on Raspi Pi Bullseye Webvisu Autostart
CODESYS Forge
talk
(Post)
Anbei meine Lösung zum Autostart der Webvisu, vllt. hilft es jemandem... =============================== Raspberry Pi Bullseye 11 Autostart Codesys Webvisu im Kiosk Mode 1)Datei erstellen: sudo nano/etc/xdg/autostart/Visustart.desktop 2)Inhalt der Datei: [Desktop Entry] Type=Application Name=Visustart Exec=bash -c "sleep 30 && /home/pi/Desktop/Visu" 3)Visu Datei erstellen sudo nano /home/pi/Desktop/Visu 4) Inhalt der Datei: #!/bin/sh xset -dpms xset s off xset s noblank matchbox-window-manager -use_titlebar no & unclutter & chromium-browser -display=:0 --kiosk --incognito --window-positon=0,0 5) Datei ausführbar machen sudo chmod+x /home/pi/Desktop/Visu ... nach Neustart Raspi startet die Codesys Webvisu automatisch im Kiosk Mode ===============================
Last updated: 2024-03-24
Post by kronlundo on Licensing info not available (WAGO PFC200 + Codesys V3)
CODESYS Forge
talk
(Post)
Hi! We're using a WAGO PFC200 for several projects towards the energy sector, and recently upgraded to CODESYS V3. We have the "IEC 60870-5-104 Server" package in a test program, and it works well with the package in DEMO mode. However, when we acquired a license for the "IEC 60870-5-104 Server" package and tried to add the license on the PFC200 through the license manager, we get an error (see attached file). It seems like there is no CmContainer on the device, does anyone have an idea on how to fix this? We've also contacted WAGO on this issue a while back with no feedback yet.
Last updated: 2024-06-10
Post by thn-power on How to change OPC NodeId IdentifierType
CODESYS Forge
talk
(Post)
Hi Yet another OPC UA question. When setting up a OPC server using "Communcation manager" (Symbol set and information model) in Codesys the NodeId is always given as "opaque" type. At least when browsing using UAExpert. Other standard OPC objects use numeric (or string) identifier, but for some reason my variables seems to get opaque/binary type. See attached photo. How can I change this? I can't see that this is a parameter in the CodesysControl.cfg. Can this be specified in the information model nodeset? And is it possible to specify the exact numeric or string NodeId for each instance? And on a related topic, is there a way to export the OPC server nodeId's with variable name so that it can be imported in a OPC Client? The .xml files in the project folder does not seem to contain the NodeId.
Last updated: 2024-09-20
Post by timvh on Communication between applications on same device/controller/runtime (Win RTE 3.5.20.20)
CODESYS Forge
talk
(Post)
If you have a Windows system (RTE), then why not run the CODESYS HMI as separate controller. This could easily be moved to another PC if required. In the HMI you could also still use the Symbolic Var access as part of the Data Source Manager, although maybe OPC is the preferred way to make it more future proof. Or what about the Remote Target Visu. Then you can reduce the load of the main controller, while still only having to create one application including Visualization. This is now also supported for Linux systems. See: https://content.helpme-codesys.com/en/CODESYS%20Control/_rtsl_target_visu_for_linux.html https://content.helpme-codesys.com/en/CODESYS%20Visualization/_visu_execute_remote_target_visu.html
Last updated: 2024-09-28
Post by timvh on Visuutils FbOpenDialog(Extended) not open Dialog from POUs
CODESYS Forge
talk
(Post)
I had a similar situation recently where this didn't work, but read to the end to see the solution. The reason is that CODESYS only downloads visualisations (dialogs) if they are part of the project or linked to the project. In your case the dialog is not loaded onto the controller. But the solution is pretty simple: Double click on the Visualization Manager in your application. Select the Tab "Visualizations". Here you can see that your dialog is not "checked". Do this manually and load your project on the controller. Then your code should be able to open the dialog, because now it exists on the controller.
Last updated: 2024-09-28
Post by etienneneu on loading delay with the option "check client animations and overlay of native elements"
CODESYS Forge
talk
(Post)
Hello guys, I have the following problem with the Codesys visualization (4.6.0) and Codesys V3.5.20.20. I would like to use my own HTML5 elements for my visualization. To do this, I have to select the option “Support client animations and overlay of native elements” in the visualization manager. But with the selection of this option, the visu has a massive loading delay when changing frame content. This happens even if I have not even added HTML5 elements. However, if this option is deactivated, then changing the content of the frames works without any problems, it loads instantly. I have already tried to change various refresh rates but without success. Have any of you experienced this and been able to fix it?
Last updated: 2024-10-30
Post by vformanek on No source code available for profinet library
CODESYS Forge
talk
(Post)
Hello, I have been using CODESYS for a while and after updating to version 3.5.18.50 the code randomly stops with this fault. Why is that ? I have tried to locate the fault in the Call Stack but I dont know what to do now... I have updated the projects properly for the version I am using. This fault started happening after like 14 days of using the new version of CODESYS.
Last updated: 2023-08-23
Post by martinlithlith on Relay board / relays for raspberry pi 3 b+
CODESYS Forge
talk
(Post)
hi! im planning a project on a raspberry with Codesys. For this I'll need a number of relays to control heating and fans, all a max of 24v and about 2a. How would i know if the board / relays i buy will be working with Codesys? Does every hat work or does it need a library/driver? is there a list of drivers/libraries created? as this is a hobby project all tips on a relay board or single boards that works with codesys and not to expensive are very welcome.
Last updated: 2023-09-03
Post by timvh on When Keyboard Key is in Hold, then Webvisu is extreme slow and latent
CODESYS Forge
talk
(Post)
I'm not really sure what you are trying to do, but maybe you are referring to using the CmpCharDevice library? When you "open" the connection to a device, you can pass flags. What helped me is to set the non-blocking flag. I'm not sure if this is what you are referring to, but maybe it helps: dFlags: DINT := CmpCharDevice.ACCESS_MODE.O_RDONLY + DINT#4000; // see details for flags: http://linux.die.net/man/2/open, + DINT#4000 is for non-blocking hDevice := CmpCharDevice.CDOpen(szFilename, dFlags, Result);
Last updated: 2023-09-20
Post by andrax on Mux I2C
CODESYS Forge
talk
(Post)
the TCA9548a does not work in Codesys. In Pyton this is only queried once and in Codesys cyclically. Of course you can also insert a terminating resistor in each port, then you should have no problems. I use this one: https://botland.de/8-bit-multiplexer/12723-qwiic-mux-breakout-8-kanal-modul-mit-i2c-multiplexer-tca9548a-sparkfun-bob-16784-5904422341428.html You can simply set the library to the latest version. You do not need Oscat. Do you need an example project for the BMP280?
Last updated: 2024-01-02
Post by andrax on Mux I2C
CODESYS Forge
talk
(Post)
the TCA9548a does not work in Codesys. In Pyton this is only queried once and in Codesys cyclically. Of course you can also insert a terminating resistor in each port, then you should have no problems. I use this one: https://botland.de/8-bit-multiplexer/12723-qwiic-mux-breakout-8-kanal-modul-mit-i2c-multiplexer-tca9548a-sparkfun-bob-16784-5904422341428.html You can simply set the library to the latest version. You do not need Oscat. Do you need an example project for the BMP280?
Last updated: 2024-01-02
Post by usacodesysuser on How to connect serial devices ?
CODESYS Forge
talk
(Post)
@eschwellinger do you have any examples of using a USB barcode scanner? I have read through the forums here and I am unable to find how to get the barcode data to populate in a text field without having to first click into the text field to activate it. Is there a library that allows you to access the barcode data? I am really new to this in general any help is greatly appreciated, hopefully you have a pretty clear example
Last updated: 2024-01-06
Post by haydermsalih on OSCAT Network LIBRARY: FTP_CLIENT
CODESYS Forge
talk
(Post)
Hello I am using FTP_CLIENT to donwnload/Upload a text or CSV file from FTP server. UpLoading from PLC to FTP server is working without any problem but when I try to download from FTP server I get an error. The FTP_CLIENT Block allows me to add URL but I do not where I can specify the direcory to save the downloaded file... is there anyone has an experience with downloading from FTP server using FTP_CLIENT block. Thanks in advance Hayder
Last updated: 2024-01-24
Post by miodusy on File transfer via visu and codesys automation server
CODESYS Forge
talk
(Post)
I have a problem with the file transfer library. Namely, it does not work via the codesys server. (error 5; overtime, and visualization resets). They operate mostly in local chains. I tested different browsers and VPN from the router. It works everywhere, except through access from the codesys automation server. The client, having many machines under one account, prefers to keep it that way rather than use an individual VPN just to download a backup. Does anyone have an idea what the problem is? Sylwester M.
Last updated: 2024-03-07
Post by androidzz on Json Builder problem?
CODESYS Forge
talk
(Post)
Dear reader, I am using the codesys JSON utilities SL, 1.9.0.0 library. And then specifically the FB JSONBuilder. I need to create a main object with at least 2 objects in it. The first object is no problem, but I cannot insert the second object into the main object. See attached my code and the result I get. I am assuming that I am doing something wrong with the parent index but have tried a lot and can't get it done. Kind regards, Rob
Last updated: 2024-03-11
Post by gregorpl on Tosibox With EATON XV300
CODESYS Forge
talk
(Post)
HEllo, I need to connect with PLC XV300 , the problem is for me not simple. The PLC have remote control by Tosibox VPN tunel. I can see the screen from PLC, but i also want to se Input and Output the PLC . I try to scan the network by useing tosibox Gateway but its not working. Where i should looking the problem ? DO i need added special library ?
Last updated: 2024-03-12
Post by k4zz on Continuous Build Server
CODESYS Forge
talk
(Post)
Hallo Martin, Thank you so much for the Code example. It works really fine for .porject Types. However, I encountered a challenge when attempting to apply it to .library Types. I also tried the option to "Perform static analysis automatically after compilation" # get Project values myProject = projects.primary # Creates an active application app = myProject.active_application # build Application and run static code analysis app.generate_code() Could you please offer any insights into why this might be occurring?
Last updated: 2024-03-15
Post by k4zz on Statisch Code Analyse ausführen via Python
CODESYS Forge
talk
(Post)
Derzeit arbeite ich daran, statische Codeanalyse in unsere (CI/CD)-Pipeline zu integrieren. Konkret habe ich die statische Codeanalyse erfolgreich für .project-Typen durchgeführt, und sie funktioniert einwandfrei. Allerdings habe ich Schwierigkeiten bei der Ausführung derselben für .library-Typen festgestellt. Hierbei habe ich zwei Methoden ausprobiert: system.commands["staticanalysis", "run"].execute() # get Project values myProject = projects.primary # Creates an active application app = myProject.active_application # build Application and run static code analysis app.generate_code()
Last updated: 2024-03-18
Post by k4zz on Scripting static code analysis
CODESYS Forge
talk
(Post)
Currently, I am working on integrating static code analysis into our CI/CD pipeline. Specifically, I have successfully performed static code analysis for .project types, and it works flawlessly. However, I have encountered difficulties in executing the same for .library types. In this regard, I have tried two methods: system.commands["staticanalysis", "run"].execute() # get Project values myProject = projects.primary # Creates an active application app = myProject.active_application # build Application and run static code analysis app.generate_code() your help is greatly appreciated.
Last updated: 2024-03-18
Post by dagsupport on CAA SerialCOM - hCom Reset max value 1023
CODESYS Forge
talk
(Post)
Hi everybody We are currently working on a project with an RS232 serial COM interface and using the CAA SerialCOM library. We have it working fine reading and writing data, although we have found an issue we cannot resolve and any suggestions would be helpful. We have noticed that after a while the RS232 stops working. We have tracked this down to the HANDLE hCom keeps increasing and when this reaches 1023 the COM returns an unknown error "5003". Is there a way to reset this hCom reference? Thanks Richard