Post by totorovic on IO-LINK Package - new license model
CODESYS Forge
talk
(Post)
Thank you for your answer. Finally I don't confirm that it used to work before. It seems that the IO-link Package is needed is you want to configure the network, but you don't need it if you use generic IO-link devices.
Last updated: 2024-06-06
Post by strannik on SoftMotion SML
CODESYS Forge
talk
(Post)
I use SoftMotion Light libraries in my CodeSys 3.5 project. Activated the license. But probably not all the actions were completed. In the configuration of the axes A message that the driver is running in demo mode. Please tell me what complete actions need to be performed. Thanks
Last updated: 2024-07-06
Post by damian177 on Problem with downloading OPC UA tags by Data Source Manager
CODESYS Forge
talk
(Post)
In my OPC UA Server is about 12 thousands tags. Can by possible that downloading tags from OPC UA Server lasts a long time , and when expires about 2 hours (demo license time) that downloading freezes ?
Last updated: 2024-09-04
Post by paulpotat on Can't open license manager with raspberry CM4
CODESYS Forge
talk
(Post)
Do someone have any information on this topic ? We tried several different CM4 boards without success, and we cannot install the licenses we bought anymore... Isn't CodeSys supposed to support CM4 Raspberry pi ?
Last updated: 2024-10-15
Post by yannickasselin on The selected container ... does not fit your ticket
CODESYS Forge
talk
(Post)
Not sure this will help you but I had the same issue and was able to activate the license on a Windows PC using the Web Depot in a web browser. https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_installing_license.html
Last updated: 2025-01-08
Post by trusty-squire on Codesys Licenses - How to reload them after updating the Raspberry Pi OS
CODESYS Forge
talk
(Post)
https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_cmd_license_manager.html Search the help page above for "Return License". Should be what you're looking for.
Last updated: 2025-03-16
Post by sachem on Problem retain values Weidmuller UC20-WL2000
CODESYS Forge
talk
(Post)
Good afternoon. I am working with a weidmuller uc20-wl2000 controller, using a codesys license. We made a ladder code to control a process, and it works well, but we want some variables to remain stored even when the controller is turned off. We tried to use retain variables, but at the time of loading the program, when we went offline from the controller, the program was deleted, it did not remain in the controller, and in the same way if we turned off the controller. In addition to this, when we tried to program it again, the program would not stay loaded and began to present errors with the opc-ua communication. What could be causing this problem? How can we maintain the values of the variables without damaging the program or affecting the controller? thank you
Last updated: 2024-04-10
Post by r-niedermayer on Issue with WebVisu on Raspberry PI
CODESYS Forge
talk
(Post)
Regarding to your application: When clicking in the web visualization, the boolean variable will be tapped for both buttons. The LED in the web visualization lights up as long as the variable is true The used variables should come from the GVL, ad/or thePLC_Prg. We see no difference or problem in both projects: You have created a visuelement Push button a a tapper, that is supposed to control the variable in this way as expected. This is also reflected (switching Bool from false to true) in the program code, as well as in the (GVL declared) variables. Wherever the misunderstanding comes from: no, this is not memory or license related. Our best guess: it is probably more of an applicative/conceptual implementation.
Last updated: 2024-04-11
Post by rossanoparis on After un upgrade of "CODESYS Control for Raspberry Pi MC SL" from v4.7 to v4.9 SysFileOpen function stopped working
CODESYS Forge
talk
(Post)
For those who will step on this thread. Everything is fine, I had only to increase by 1 my place holders number. For sure the system is occupying the number 1 without being declared ... Below the modification I made to get my code working. [SysFile] PlaceholderFilePath.2=/home/pi/hpca/bin, $hpcabin$ PlaceholderFilePath.3=/home/pi/hpca/cfg, $hpcacfg$ PlaceholderFilePath.4=/home/pi/hpca/logs, $hpcalogs$ PlaceholderFilePath.5=/home/pi/hpca/resources, $hpcares$
Last updated: 2023-08-22
Post by rcaponi on Codesys 3.5 SP19 Patch 4. Trace context menu does not work
CODESYS Forge
talk
(Post)
Hello, I'm using the new Codesys 3.5 SP19 Patch 4 version with CODESYS Control for Raspberry Pi MC SL v4.8. Compared to the Codesys 3.5 SP19 Patch 1 version, the context menu on a Trace object no longer works. So I can no longer run the Downloader Trace command. Do any options need to be enabled with the new version? Best regards Roberto Caponi
Last updated: 2023-10-24
Post by timvh on Management of a PLC network from a remote station
CODESYS Forge
talk
(Post)
Maybe the CODESYS HMI is a good solution. https://store.codesys.com/en/codesys-hmi-sl-bundle.html Run this on the remote main control station. In the HMI application you can add the data source manager and to this manager you can add Data sources. A data source has a reference to the PLC you want to connect to and can get access to the variables of the PLC application. You can then use these variables in the visualization of the HMI application.
Last updated: 2023-12-04
Post by dhumphries on Control for Linux SL on Ubuntu Core
CODESYS Forge
talk
(Post)
Try using a password instead of a public key to log into the controller. I have a video showing how to do this on a default installation of Ubuntu server, it should work the same for Ubuntu Core. https://youtu.be/rj0dOhgnGjs?si=352PmveEP7JXZnO- I sign in to the controller at about 6:40 in the video. I have never tried to remove the public key and revert to signing in using a password, but it looks pretty straightforward https://askubuntu.com/questions/745423/how-to-turn-off-password-less-login-for-ssh
Last updated: 2024-02-28
Post by schnepper on Error building Extension SDK Linux code
CODESYS Forge
talk
(Post)
I'm installed the CODESYS Control for Linux SL package and am trying to use the Extension API to call a simple C function. When I get to the step to run "make all" on the Linux machine, I get the error: build interface header: out/CmpFirstTestItf.h from CmpFirstTestItf.m4 ERROR: This functionname does not contain _cext (this is mandatory, see help for details): DEF_API(void',CDECL',external_struct__fb_init',(external_struct_fb_init_struct *p)',1,0x1F77E075,0x00000001) Why does "Generate Runtime System Files" create a function that does not have cext in the name? What am I missing?
Last updated: 2024-04-01
Post by rabaggett on CODESYS control for Raspberry Pi 64 SL errors
CODESYS Forge
talk
(Post)
Update: I started over. I saved progress at each step. all compiled zero errors, zero warnings. Pre-processor messages remain, but I can make progress. Until I try to re- load the project file in Codesys. Re-loaded files error as above when compiled, even though they compiled error-free immediately before saving. Is my installation borked? (Not easy to re-install due to IT madness...)
Last updated: 2024-05-03
Post by trusty-squire on How to adapt Codesys Control SL to custom board
CODESYS Forge
talk
(Post)
For general usage, these links might help you out. If you are looking at using I2C interfaces, examples from the Raspberry Pi will probably be useful, even if your board isn't a Raspberry Pi. https://content.helpme-codesys.com/en/CODESYS%20Examples/_ex_rts_serial_com.html https://content.helpme-codesys.com/en/CODESYS%20Examples/_ex_raspberry.html If you're developing your own drivers, I can't help you there, although the link you provided will help. If you drill in deeper, the I2C page for example shows function block and method usage, etc. Good luck!
Last updated: 2024-08-09
Post by davidbo on RPI can system operation like rm in a shell have an impact on a Task cycle time
CODESYS Forge
talk
(Post)
CODESYS Control for Raspberry Pi MC SL v4.4.0.0 CANopen_Manager 4.2.0.0 I did not call rm directly from my TASK-i2c, it was trough the attached python script. It is not always a problem happens, but sometimes a rm takes a long time. I reduced the amount of calls to logi2c.py but I don't understand why TASK-i2c sometimes can cause problems for TASK-CAN
Last updated: 2024-09-27
Post by davidbo on RPI can system operation like rm in a shell have an impact on a Task cycle time
CODESYS Forge
talk
(Post)
CODESYS Control for Raspberry Pi MC SL v4.4.0.0 CANopen_Manager 4.2.0.0 I did not call rm directly from my TASK-i2c, it was trough the attached python script. It is not always a problem happens, but sometimes a rm takes a long time. I reduced the amount of calls to logi2c.py but I don't understand why TASK-i2c sometimes can cause problems for TASK-CAN
Last updated: 2024-09-27
Post by winki on Modbus TCP & RTU with Control for Linux SL
CODESYS Forge
talk
(Post)
Hello, Today I am able to test ma industrial computer in my test bench. I am able to do all the configuration throught my VPN, 100% remote. I can see the gateway & the Virtual PLC. Now I would like to do some Modbus TCP Client & Modbus RS485. But I am lost due to docker ! When I go to modbus TCP it only gave me the docker network, but not my eth0 & eth01 When I go to modbus rtu, how can I create the link between Com number & my /dev/ttyRS485 Loic,
Last updated: 2024-10-23
Post by mascara on TouchScreen does not work in Webvisualization.
CODESYS Forge
talk
(Post)
I am configuring a Lenovo M900 computer with CODESYS Control RTE SL 3.5.20.30. I use an Aoc E2272pwut LED 21.5 monitor. The touchscreen works perfectly in the Windows 10 PRO environment but does not work in the WebVisualization environment (Window opened at PLC startup). Does anyone know if it is necessary to configure any drivers in Win RTE? I am at your disposal for any questions. Thank you.
Last updated: 2024-11-11
Post by jeroenaero on CodeSys Raspberry pi I2C driver not found
CODESYS Forge
talk
(Post)
Finnaly i get it working. There was a line in the file that set the ADS1015 chip in /boot/firmware/config.txt which i removed and after that the ADS1115 has a green turning circle and i got values. i created a new component so it fits our ADS1015. see screenshot. It works also with Codesys Control for Raspberry Pi 64 SL after adding the ULINT_TO_UDINT conversion in the library. i think the chip was all the time in use by the Raspberry pi itself. Thanks for your help!
Last updated: 2024-11-12
Post by jvfred on CodesysHMI.exe: Start Error
CODESYS Forge
talk
(Post)
I have used Codesys HMI SL on several projects. Today I turned my PC on to start building another project and received the following error message when I tried to start my device: "CodesysHMI.exe: Start Error One of the following licenses is required: CodeMeter 101597:13 Failure reason: CmContainer Entry not found, Error 200 CodeMeterAct 5000304:13 Failure reasons: CmContainer Entry not found, Error 200" I have tried reloading HMI SL and even updated to the current version with no success. I am using HMI SL version V3.5.20.10. Any help would be greatly appreciated.
Last updated: 2024-11-01
Post by jvfred on CodesysHMI.exe: Start Error
CODESYS Forge
talk
(Post)
I have used Codesys HMI SL on several projects. Today I turned my PC on to start building another project and received the following error message when I tried to start my device: "CodesysHMI.exe: Start Error One of the following licenses is required: CodeMeter 101597:13 Failure reason: CmContainer Entry not found, Error 200 CodeMeterAct 5000304:13 Failure reasons: CmContainer Entry not found, Error 200" I have tried reloading HMI SL and even updated to the current version with no success. I am using HMI SL version V3.5.20.10. Any help would be greatly appreciated.
Last updated: 2024-11-01
Post by rossanoparis on After un upgrade of "CODESYS Control for Raspberry Pi MC SL" from v4.7 to v4.9 SysFileOpen function stopped working
CODESYS Forge
talk
(Post)
Hello at all. After un upgrade of "CODESYS Control for Raspberry Pi MC SL" from v4.7 to v4.9 SysFileOpen function stopped working. I'm not able to read or write files from the PLC application. Before this upgrade all worked fine. I've read this thread [ https://forge.codesys.com/forge/talk/Engineering/thread/3da9ded84e/ ] Despite I followed that indications I couldn't get my code working again. Perhaps I'm missing something or I didn't understand how to use placeholders at all. Is there a different syntax to use for "SysFileOpen" in order to use placeholders? Thanks in advance for your help. Information Compiler: CODESYS V3.5 SP19 Patch 2 Runtime: codesyscontrol 4.9.0 HW: KUNBUS RevPi Connect S Below the paths I want to access (The entire CODESYSControl_User.cfg file is attached) [SysFile] PlaceholderFilePath.1=/home/pi/hpca/bin, $hpcabin$ PlaceholderFilePath.2=/home/pi/hpca/cfg, $hpcacfg$ PlaceholderFilePath.3=/home/pi/hpca/logs, $hpcalogs$ PlaceholderFilePath.4=/home/pi/hpca/resources, $hpcares$
Last updated: 2023-08-22
Post by fizzy-bubblech on 3.5 P20 hangs - no response
CODESYS Forge
talk
(Post)
Colleagues, i have the same problems. At the current time, I have to use the new version of the Codesys (3.5.20.10) + Control for Linux SL 4.11.0.0, but it works unstable : theree are a lot of freezes and not-respondings. I tested this on different projects: those that were created in the current version of the project, and those that were migrated from other versions of the development environment. Compiling a project without connecting to a controller is fast enough. The first downloading of the code into the controller, too. But as soon as you need to make edits and download a new code problems begin. Codesys "freezes" at the "Generation code" stage for 15-20 minutes. And only after that time loads the code into the controller. Previously, we used version 3.5.17.60 + Control for Linux SL 4.7.0.0. The process took 1-2 minutes. Do you have any ideas how can i fix it? I will be grateful for your answers.
Last updated: 2024-06-27
Post by peterkcontrols on Codesys Network driver install for Codesys Control RTE x64
CODESYS Forge
talk
(Post)
Hello I am trying to download my project onto my Codesys Control RTE x64 soft PLC. and I have had an issue when downloading. [FATAL ERROR] Unresolved reference: 'SYSETHERNETADAPTEROPEN' [FATAL ERROR] Unresolved reference: 'SYSETHERNETADAPTERCLOSE' [FATAL ERROR] Unresolved reference: 'GETNUMBEROFADAPTERS' [FATAL ERROR] Unresolved reference: 'GETADAPTERINFO' [FATAL ERROR] Unresolved reference: 'SYSETHERNETIPFRAMERECEIVE' [FATAL ERROR] Unresolved reference: 'SYSETHERNETETHFRAMESEND' [FATAL ERROR] Unresolved reference: 'SYSETHERNETETHFRAMERECEIVE' [FATAL ERROR] Unresolved reference: 'SYSETHERNETIPFRAMESEND' [FATAL ERROR] Unresolved reference: 'SYSETHERNETFRAMERELEASE' Looking on the forum I have found other people had to install the network driver, which I have done following this youtube video by codesysGroup: https://youtu.be/10oj4wABaKc?si=664l83JXUGQSDlAe I have added the network driver, please see attached image. I have checked my BIOS to make sure my secure boot status is disabled, see attached image. when I go to component manager, the drop down menu doesnt have the new network adapter, see attached image. I have not yet purchased or installed any licenses is that what I am missing? What other reason is there that I can't download to the runtime. Thanks
Last updated: 2025-03-18