Post by llewv123 on Codesys Control for RPi and Waveshare AD/DA hat
CODESYS Forge
talk
(Post)
Good day, I am attempting to use a Waveshare AD/DA precision HAT with RPi 4B+, using Codesys Control for Rpi. The waveshare hat uses SPI. I am successfully using the RPi GPIO (inputs and outputs) but do not know how to access the AD/DA channels. Any help would be appreciated.
Last updated: 2025-08-04
Post by timvh on Sysfile inuts
CODESYS Forge
talk
(Post)
To prevent ambiguous use of this enumeration value. Let's say another ENUM is available in your project or in another library which has an enumeration value AM_WRITE, then it is not clear which AM_WRITE you want to assign. By this qualified access to the SysFile.AM_WRITE, it is completely clear for the compiler.
Last updated: 2024-01-14
Post by francescoc on Access to the path *** is denied
CODESYS Forge
talk
(Post)
Hello, I encountered similar problems, and it appears they were linked to certain add-ons. Resolving this issue turned out to be quite complex. However, we managed to find a solution by downgrading both the "CODESYS Communication" and "CODESYS Recipes" components via the CODESYS Installer, accessible under the "Tools" section.
Last updated: 2024-02-12
Post by jdjennings1962 on Is there any support for I2C on Raspberry Pi?
CODESYS Forge
talk
(Post)
Hello, our team is able to use Raspberry Pi on CODESYS, but we purchased two peripherals that utilize I2C and we cannot figure out how to access these devices in CODESYS. But they are working using Python. Does anyone have a suggestion or an existing library that might help support this? Thank you, Jeff
Last updated: 2024-02-29
Post by timvh on Limiting Memory Access of an Array to Within its Bounds
CODESYS Forge
talk
(Post)
Add the object "POU for Implicit Checks" to your application, then select "Bounds check". This will create a function which is automatically called each time an array is write accessed. In the function you can handle "out of bounds" situations. By default it will be limited to its lower or upper bound.
Last updated: 2024-03-06
Post by yannickasselin on Linux ARM64 SL, GPIO Access
CODESYS Forge
talk
(Post)
A bit of work but maybe possible to make your own driver using "CODESYS Control SL Extension Package". Look at the "ExternalIoDrv" example. It is installed in "C:\Program Files\CODESYS 3.5.20.0\CODESYS\CODESYS Control SL Extension Package" when you install the "CODESYS Control for Linux SL".
Last updated: 2024-05-08
Post by talhaali on Can't read Alarm Class from Alarm Storage
CODESYS Forge
talk
(Post)
Hi, I am trying to access active alarms in code(As alarm count variable updates only when we go to to alarm table frame in visualization). I wrote following code but it is not working: VAR iCountActiveAlarms : INT; parritfActiveAlarms : POINTER TO ARRAY[0..0] OF IAlarm; itfAlarmManagerClientAll : IAlarmManagerClient; END_VAR AlarmManager.g_AlarmHandler.GetActiveAlarms( itfAlarmManagerClient :=itfAlarmManagerClientAll, iCountActiveAlarms => iCountActiveAlarms, parritfActiveAlarms => parritfActiveAlarms); The Value is always 0. Please help.
Last updated: 2024-06-06
Post by talhaali on Can't read Alarm Class from Alarm Storage
CODESYS Forge
talk
(Post)
Hi, I am trying to access active alarms in code(As alarm count variable updates only when we go to to alarm table frame in visualization). I wrote following code but it is not working: VAR iCountActiveAlarms : INT; parritfActiveAlarms : POINTER TO ARRAY[0..0] OF IAlarm; itfAlarmManagerClientAll : IAlarmManagerClient; END_VAR AlarmManager.g_AlarmHandler.GetActiveAlarms( itfAlarmManagerClient :=itfAlarmManagerClientAll, iCountActiveAlarms => iCountActiveAlarms, parritfActiveAlarms => parritfActiveAlarms); The Value is always 0. Please help.
Last updated: 2024-06-06
Post by talhaali on Can't read Alarm Class from Alarm Storage
CODESYS Forge
talk
(Post)
Hi, I am trying to access active alarms in code(As alarm count variable updates only when we go to to alarm table frame in visualization). I wrote following code but it is not working: VAR iCountActiveAlarms : INT; parritfActiveAlarms : POINTER TO ARRAY[0..0] OF IAlarm; itfAlarmManagerClientAll : IAlarmManagerClient; END_VAR AlarmManager.g_AlarmHandler.GetActiveAlarms( itfAlarmManagerClient :=itfAlarmManagerClientAll, iCountActiveAlarms => iCountActiveAlarms, parritfActiveAlarms => parritfActiveAlarms); The Value is always 0. Please help.
Last updated: 2024-06-06
Post by talhaali on Alarm Manager:
CODESYS Forge
talk
(Post)
Hi, I am trying to access active alarms in code(As alarm count variable updates only when we go to to alarm table frame in visualization). I wrote following code but it is not working: VAR iCountActiveAlarms : INT; parritfActiveAlarms : POINTER TO ARRAY[0..0] OF IAlarm; itfAlarmManagerClientAll : IAlarmManagerClient; END_VAR AlarmManager.g_AlarmHandler.GetActiveAlarms( itfAlarmManagerClient :=itfAlarmManagerClientAll, iCountActiveAlarms => iCountActiveAlarms, parritfActiveAlarms => parritfActiveAlarms); The Value is always 0. Please help.
Last updated: 2024-06-06
Post by talhaali on Alarm Table Issues
CODESYS Forge
talk
(Post)
Hi, I am trying to access active alarms in code(As alarm count variable updates only when we go to to alarm table frame in visualization). I wrote following code but it is not working: VAR iCountActiveAlarms : INT; parritfActiveAlarms : POINTER TO ARRAY[0..0] OF IAlarm; itfAlarmManagerClientAll : IAlarmManagerClient; END_VAR AlarmManager.g_AlarmHandler.GetActiveAlarms( itfAlarmManagerClient :=itfAlarmManagerClientAll, iCountActiveAlarms => iCountActiveAlarms, parritfActiveAlarms => parritfActiveAlarms); The Value is always 0. Please help.
Last updated: 2024-06-06
Post by talhaali on Alarm status in logic
CODESYS Forge
talk
(Post)
Hi, I am trying to access active alarms in code(As alarm count variable updates only when we go to to alarm table frame in visualization). I wrote following code but it is not working: VAR iCountActiveAlarms : INT; parritfActiveAlarms : POINTER TO ARRAY[0..0] OF IAlarm; itfAlarmManagerClientAll : IAlarmManagerClient; END_VAR AlarmManager.g_AlarmHandler.GetActiveAlarms( itfAlarmManagerClient :=itfAlarmManagerClientAll, iCountActiveAlarms => iCountActiveAlarms, parritfActiveAlarms => parritfActiveAlarms); The Value is always 0. Please help.
Last updated: 2024-06-06
Post by andreag0 on How to access to variable value through symbolic string name
CODESYS Forge
talk
(Post)
Hello, anyone know how to get valiable value using a symbolic string name? For example: - send string to runtime using TCP/IP contains "GVL.TestINT" and get back the value. I need function that will translate the string to symbolic variable. Thank you. Andrea
Last updated: 2024-06-13
Post by nano on How to access to variable value through symbolic string name
CODESYS Forge
talk
(Post)
this is not easily. From Point of SL-Licenses Codesys didnt provide the informations how to do. We created an own CDS-Component for that Behaviour. This Informations are available for OEM, if you are an OEM you can find the Informations in the RTS-Documentation.
Last updated: 2024-06-14
Post by eschwellinger on Same program to more than one PLC
CODESYS Forge
talk
(Post)
just open http://localhost:8080 in Chromium then it will show the webvisu ( sure you need to this in your CODESYS Application)
Last updated: 2023-08-24
Post by marekxc on Error C0521 - unknow compiler
CODESYS Forge
talk
(Post)
Select in tree "DEVICE", right-click and select "Update Device" Select "Library manager" and Change the version of the Library (down manualy). Samoetimes "Try reload Library". If you open a project version 3.5.19 in version 3.5.16, there are difficulties.
Last updated: 2023-09-02
Post by sedoerr on Check For Open Dialogs On Client
CODESYS Forge
talk
(Post)
You need to create a function around this function to check the dialogs you use in your program. That's the way i have done it.
Last updated: 2023-09-26
Post by sedoerr on Check For Open Dialogs On Client
CODESYS Forge
talk
(Post)
FUNCTION CheckDialogOpen : BOOL VAR_INPUT sDialogName : STRING; END_VAR VAR pstClientData : POINTER TO VisuElems.VisuStructClientData; itfDialogManager : VisuElems.IDialogManager; itfMyDialog : VisuElems.IVisualisationDialog; END_VAR VisuElems.g_ClientManager.BeginIteration(); WHILE (pstClientData := VisuElems.VisuElemBase.g_ClientManager.GetNextClient()) <> 0 DO itfDialogManager := VisuElems.g_VisuManager.GetDialogManager(); itfMyDialog := itfDialogManager.GetDialog(sDialogName); CheckDialogOpen := VisuDialogs.VisuDlgUtil_IsDialogOpen(itfMyDialog,pstClientData,itfDialogManager); IF CheckDialogOpen THEN EXIT; END_IF END_WHILE
Last updated: 2023-09-26
Post by gurke258 on EL2911
CODESYS Forge
talk
(Post)
Hello, sorry to open this again. I can't find the right ESI for EL1918 as Safety PLC.. I only have the one without safety PLC. I look on Beckhoff website but i didnt found it. Can anyone help me? EDIT: I found it :)
Last updated: 2023-10-12
Post by open on How to create a stopwatch?
CODESYS Forge
talk
(Post)
Hi, how to create a stopwatch when start is pressed, timer will start counting and stop is pressed, timer will stop counting in structured text?
Last updated: 2023-12-07
Post by j-page on I have errors while building the project
CODESYS Forge
talk
(Post)
I am also suffering from the same problem. The "Clear All" in the build clears the error once, but when I open the project again, the same error occurs again. Can someone please help me?
Last updated: 2024-07-11
Post by robert-o on Converting hex bytes to float
CODESYS Forge
talk
(Post)
Try OSCAT_BASIC and Function DW_TO_REAL. DWORD_OF_BYTE my although help. The Lib is open and free. It is not necessary to add this Lib, you can use/copy the source code just to get an idea.
Last updated: 2024-08-05
Post by andreiot40 on Step motor ECT60 Ethercat in codesys 3.5
CODESYS Forge
talk
(Post)
Thanks for your response. for Master in log i have : no slaves found, Interface could not be opened, could not open network adapters. Status : Not running FOR ETC60 There is nothing !!!
Last updated: 2024-08-15
Post by open on (no subject)
CODESYS Forge
talk
(Post)
Hello, I want my button to be attached image ON_Good when variable true but however when i copied the visualization object into a new visualization screen it become attached image ON_Bad. Anyone know how to make it attached image ON_Good? Warmest regards,
Last updated: 2024-09-03
Post by timvh on CoDeSys 3.5 SP20 "No Offline Help installed"
CODESYS Forge
talk
(Post)
Open the CODESYS Installer (from the menu Tools). Go to Browse. Search for: help ... Select the CODESYS Offline Help which you would like to install. (probably you have to close CODESYS to install it and reopen it after installation).
Last updated: 2024-10-01
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.