Post by dhumphries on How to determine code size CODESYS Forge talk (Post)
I'm trying to determine which Codesys Control license I need, the Control Standard S has all the features I think I'll need, but the code size is limited to 3mb, I created a simple program with only 1 line of ladder logic and a simple visualization with a button and an indicator. When I generate code I get some messages, one indicates that the total allocated memory size for code and data is 2.1mb. Is this metric the correct size of the code? I question the size because it exceeds the allowable code size for the Basic S and Basic M licenses and consumes 2/3 of the available memory for the Basic L or Standard S license. What tool can I use to estimate the size of code as it relates to the runtime license limit?
Last updated: 2024-04-05

Post by dkugler on build (F11) / generate code using a python script file CODESYS Forge talk (Post)
thank you very much! I found the generate_code methode, but struggled with the primary and active_application. With this expample I will be able to play around. If the code generation takes a minute or more I often switch to other programs and don't notify the process is finished. So now I'll get an alert and will switch back immediately. My next little project will be, to beep different if there are errors and a seperate script to do the download incl. the user management data base without stopping at the dialogs asking for onlinechange/complete download and overwriting an existing database and as goody, play a beep/sound again.
Last updated: 2024-04-11

Post by valenting on Can't use new licensing with Raspberry Pi CODESYS Forge talk (Post)
Hi, I'm using Codesys control for Raspberry Pi in the latest version (4.11.0.0) When I try to install a license with the new application-based licensing, I have an error "returncode 403046401" (using codesys SP18) I updated to codesys SP20, and now I get the following error: "The selected conainer [0]: SN=..., Version=1.18, Chip=0, Rev=0 does not fit to your ticket. Please select a suitable one." The license I'm trying to install is a Codesys Control Basic L license, with a Codesys Visualization L option, according to the needs of my application. What can I do to activate my license ?
Last updated: 2024-04-22

Post by reinier-geers on License problem gateway CODESYS Forge talk (Post)
16.4 Epis What has it to do with the manufacture? It just a licence more not. So basicly the idee of codesys sucks. 3s acts like its posible to add a license. And then it depence on the manufacturer. Why ?? Its a computer !! has nothing to do with the manufacturer. Most dont what a basic licence because they have to pay for that. 3s is the problem not the manufacture of the hardware. Its like the licence of the raspberry pi. HMI is not working. Sorry you get a refund. Why suggest that its possible wen its not !!. It cost me a lot of time. Who pays my time. Why do i have to pay for somting thats not working.
Last updated: 2024-04-26

Post by jonasz on Discontinuity of A/B/C axis movement. CODESYS Forge talk (Post)
Hi, My problem was related to the behavior of the modulo axis, but maybe you will find something useful from what I write. The solution lies in path processing. Codesys offers a G-code analysis tool. Insert a CNC object into the project. The CNC settings object will be added automatically. By inserting appropriate processing modules into the CNC settings object and parameterizing them, you can test the behavior of the axis. When the effect is satisfactory, remember to add the module from CNC settings in the correct order in the processing path. Each CNC machine case is different. You need to spend some time to get your design tailored like an Armani suit. Good luck.
Last updated: 2024-05-09

Post by westcountryewe on Persistence Variables missing and DO NOT retain from Persistence Channel when using Boot Application CODESYS Forge talk (Post)
We've been experiencing an issue through SP18, SP19 and now SP20 where the Persistence Variables do not retain if we upload our program via a Boot Application. If we use the exact same program, and perform a Direct Upload via the Laptop and Ethernet connection, the Persistence Variables work exactly as expected. I have submitted 2 bug support tickets but I haven't had a response back from Codesys. Has anybody experienced the same issues and discovered a workaround? We have a requirement to utilise the Boot Application method because of logistical restrictions of being able to get out to every site, so at the moment it's a bit restriction.
Last updated: 2024-05-15

Post by fugtwad on Automation Builder V2.5 EtherCAT CM579 Master Scan for devices - >No gateway selected CODESYS Forge talk (Post)
ABB Automation Builder v2.5.0.22 Premium CodeSys 2.3.9.62 Running on Win 10 VM x64 Goal: I have an EtherCAT topology issue which normally a "Scan for devices.." on the EtherCAT master would shed some light on. Issue: Upon trying such I get a "No gateway selected" error. Question: How might I point the the "scanner" at a gateway? What is working: Gateway is running in system tray. I can go online to PLC. A scan from the "Diagnostics live" tab of the EtherCAT master gives slave status. What I have tried: Restarting gateway in system tray. Exiting system tray gateway and reloading it. Turning off firewall. Contacting ABB support multiple times. Any help appreciated.
Last updated: 2024-05-20

Post by stewnguth on New License not working. CODESYS Forge talk (Post)
Hey there, I am pretty new to the codesys space, but I got a codesys control basic M license for my raspberry pi that isntalled with no problem yesterday. Today, I went to install the visualization M locense as well because I went over the variable limit and am getting a "servernotfound" error in codesys when attempting to activate. I also tried to follow the advice in some other threads and install using a license request file on the web interface but am getting a message saying "An internal error occured" when attempting to install the license. Can anyone help me get this up and running? Thanks for your time.
Last updated: 2024-05-23

Post by jaspergain on Non-existing identifiers CODESYS Forge talk (Post)
Hello, I got a bit of a weird issue going on which is kind of annoying. So recently we switched a lot of Modbus IO to EtherCAT, as we were having issues with stability. All works fine, which is great. But sometimes when I change the program I get errors claiming that identifiers are not defined. Meaning I can't go online. See the picture below. I believe this is because some of these identifiers were used with Modbus, and they weren't properly removed/deleted? A clean all temporary fixes the issue, but it comes back again after a while of changing the code, and building. Any way to fix these non-existing required identifiers, or even find out where they are required? Thanks for the help in advance. Jasper.
Last updated: 2024-05-29

Post by kronlundo on Licensing info not available (WAGO PFC200 + Codesys V3) CODESYS Forge talk (Post)
Hi! We're using a WAGO PFC200 for several projects towards the energy sector, and recently upgraded to CODESYS V3. We have the "IEC 60870-5-104 Server" package in a test program, and it works well with the package in DEMO mode. However, when we acquired a license for the "IEC 60870-5-104 Server" package and tried to add the license on the PFC200 through the license manager, we get an error (see attached file). It seems like there is no CmContainer on the device, does anyone have an idea on how to fix this? We've also contacted WAGO on this issue a while back with no feedback yet.
Last updated: 2024-06-10

Post by jens on Modbus tcp - channel CODESYS Forge talk (Post)
Help wanted This is the first time i'm doing a Modbus Tcp project. I have some VLT with a extension module MCA-122. i'm currently unable to write to the VLT slave, but i can read from status word parameter=1603 and address := 16029 where the address is calculated from parameter is ((id x 10)-1). in the manual the functions that are supported are 3 hex, 6 hex, 10 hex, b hex and 11 hex. read holdin registers, write single register, write multiple registers, get comm. event counter, report slave id. i'm only using the Modbus Slave Channel is this wrong when trying to write to the vlt ?
Last updated: 2024-06-13

Post by salvadegianluca on SysPlcCtrl23 and C0338: The library 'cmperrors interfaces, 3.5.5.0 (system)' is supported just in 32 bit applications CODESYS Forge talk (Post)
Good afternoon to everyone; I'm stuck with this error and I don't know how to get out from it... I tried several time googling for alternative systems to control the PLC applications and resets but without success. I would like to realize the possibility to reset the CPU and to start/stop the applications as it was possible with the SysPlcCtrl23, but this library is no longer supported in 64 bit systems and it seems due to the cmperrors interfaces sub library that was included in the above said one. Someone found a work around for this issue?
Last updated: 2024-06-14

Post by salvadegianluca on SysPlcCtrl23 and C0338: The library 'cmperrors interfaces, 3.5.5.0 (system)' is supported just in 32 bit applications CODESYS Forge talk (Post)
Good afternoon to everyone; I'm stuck with this error and I don't know how to get out from it... I tried several time googling for alternative systems to control the PLC applications and resets but without success. I would like to realize the possibility to reset the CPU and to start/stop the applications as it was possible with the SysPlcCtrl23, but this library is no longer supported in 64 bit systems and it seems due to the cmperrors interfaces sub library that was included in the above said one. Someone found a work around for this issue?
Last updated: 2024-06-14

Post by salvadegianluca on SysPlcCtrl23 and C0338: The library 'cmperrors interfaces, 3.5.5.0 (system)' is supported just in 32 bit applications CODESYS Forge talk (Post)
Good afternoon to everyone; I'm stuck with this error and I don't know how to get out from it... I tried several time googling for alternative systems to control the PLC applications and resets but without success. I would like to realize the possibility to reset the CPU and to start/stop the applications as it was possible with the SysPlcCtrl23, but this library is no longer supported in 64 bit systems and it seems due to the cmperrors interfaces sub library that was included in the above said one. Someone found a work around for this issue?
Last updated: 2024-06-14

Post by salvadegianluca on SysPlcCtrl23 and C0338: The library 'cmperrors interfaces, 3.5.5.0 (system)' is supported just in 32 bit applications CODESYS Forge talk (Post)
Good afternoon to everyone; I'm stuck with this error and I don't know how to get out from it... I tried several time googling for alternative systems to control the PLC applications and resets but without success. I would like to realize the possibility to reset the CPU and to start/stop the applications as it was possible with the SysPlcCtrl23, but this library is no longer supported in 64 bit systems and it seems due to the cmperrors interfaces sub library that was included in the above said one. Someone found a work around for this issue?
Last updated: 2024-06-14

Post by salvadegianluca on SysPlcCtrl23 and C0338: The library 'cmperrors interfaces, 3.5.5.0 (system)' is supported just in 32 bit applications CODESYS Forge talk (Post)
Good afternoon to everyone; I'm stuck with this error and I don't know how to get out from it... I tried several time googling for alternative systems to control the PLC applications and resets but without success. I would like to realize the possibility to reset the CPU and to start/stop the applications as it was possible with the SysPlcCtrl23, but this library is no longer supported in 64 bit systems and it seems due to the cmperrors interfaces sub library that was included in the above said one. Someone found a work around for this issue?
Last updated: 2024-06-14

Post by salvadegianluca on SysPlcCtrl23 and C0338: The library 'cmperrors interfaces, 3.5.5.0 (system)' is supported just in 32 bit applications CODESYS Forge talk (Post)
Good afternoon to everyone; I'm stuck with this error and I don't know how to get out from it... I tried several time googling for alternative systems to control the PLC applications and resets but without success. I would like to realize the possibility to reset the CPU and to start/stop the applications as it was possible with the SysPlcCtrl23, but this library is no longer supported in 64 bit systems and it seems due to the cmperrors interfaces sub library that was included in the above said one. Someone found a work around for this issue?
Last updated: 2024-06-14

Post by tayhim on WAGO HMI Device not found CODESYS Forge talk (Post)
Hello, I'm trying to connect with a Wago TP600 HMI but without success. I'm using codysis 3.5 SP19 patch 7 (SP20 block all the time) and the official wago package is installed. However, when I scan and select my device, I get a message saying that the device doesn't match the project's device object with the possibility to update the device (as shown in the attached picture). however, after choosing to update i got a message that the device is not found. I've tried with a new empty project but the same results. do you have any ideas? Thanks.
Last updated: 2024-06-25

Post by uluking on CodeSys2.3 Modbus 64-Bit Double Read Problem CODESYS Forge talk (Post)
Hi everyone, I would appreciate your help with a problem I've been working on for a few days but haven't been able to resolve. I am reading data from a Siemens PAC3220 energy analyzer using Modbus with Wago-8202. However, the device's energy indices are given as doubles. Since a double variable is 64-bit, it is not possible to read it directly. I have been struggling for days, I have written many conversion functions but I have not been able to get results. I would appreciate your help. I read 4 word variables and processed them. I am converting them according to IEEE-754, but I can't seem to read the correct data. I would appreciate your help.
Last updated: 2025-10-27

Post by uluking on CodeSys2.3 Modbus 64-Bit Double Read Problem CODESYS Forge talk (Post)
Hi everyone, I would appreciate your help with a problem I've been working on for a few days but haven't been able to resolve. I am reading data from a Siemens PAC3220 energy analyzer using Modbus with Wago-8202. However, the device's energy indices are given as doubles. Since a double variable is 64-bit, it is not possible to read it directly. I have been struggling for days, I have written many conversion functions but I have not been able to get results. I would appreciate your help. I read 4 word variables and processed them. I am converting them according to IEEE-754, but I can't seem to read the correct data. I would appreciate your help.
Last updated: 2025-10-27

Post by msegon on OPC UA Client failed to connect CODESYS Forge talk (Post)
Hi everyone, I would appreciate your help with a problem I've been working on for a few days but haven't been able to resolve. I'm trying to read data from Tridium Niagara 4.15 OPC UA Server, but I get the error BadCertificateInvalid. As far as I understand, you need to add a CA certificate somewhere to establish a secure connection, but I don't know where. 2025-10-27T09:06:43.247Z, 0x0000008d, 4, 0, 0, * ERROR: OpcUa_Channel_BeginConnect: Cannot create secure channel without certificates! 2025-10-27T09:06:43.247Z, 0x00001090, 4, 0, 0, * ERROR: Datasource: Error Failed (268468242) in state Connecting I tried communicating without encryption, but it doesn't find the point. Has anyone managed to establish encrypted OPC UA communication?
Last updated: 2025-10-28

Post by mr-ege on Error: C0138: No matching 'FB_Init' method found for instantiation of VisuClientObjectMgr CODESYS Forge talk (Post)
Hi all! I'm trying to learn PLC Programing. Today I was making a simple PLC program, as you can see. When I compile the program without the visualization, there are no errors. However, when I add the visualization and then compile it, I get this error. I don’t know how to solve the problem. I have tried the following solutions: rebooting the PC and updating the software. Error Code: C0138: No matching 'FB_Init' method found for instantiation of VisuClientObjectMgr Compile complete -- 1 errors, 0 warnings Build complete -- 1 errors, 0 warnings : No download possible Version: CODESYS V3.5 SP21 Patch 3
Last updated: 2025-11-25

Post by tali on Configuration of disabled/deactivated visu elements CODESYS Forge talk (Post)
would be great to have such fucntionality. Sometimes it is not clear for user which elemetns are blocked and which are not - the greyed out eleemtns are not so different for low resolution / low quality screeens. What I have in my mind as well is to have a possibility to detect the visu Element clicked on and get its Access Rights. If it is blocked/deactivated, the dialog can be rised with INFO 'please login first with proper rights'. It is possible now to have a Mose event Handler ( Examples -> EventHandler) and rise the dialog out of ST (Exapmpals -> ST Dialogs). I am struggling still with getting the separate Visu Element under the mouse and its structure info
Last updated: 2025-12-05

Post by pernockham on Trend legend naming and access/config to/of trend/legend-variables CODESYS Forge talk (Post)
Trying the web-version of trend-data. This seems to be a impressive tool, but I lack/cant find a number of what I would think are important parts. There does not seem to be a way to get away from the dot.notated variable naming in the legend.. A developer might want the dot-notation but an end-customer will surely not. For instance I want to display 12 temperatures, instead of t1, t2 etc.. they will be named. gvl_io.unit[1].trend.temps.t1_a gvl_io.unit[1].trend.temps.t1_b gvl_io.unit[1].trend.temps.t1_c gvl_io.unit[1].trend.temps.t2_a .. gvl_io.unit[1].trend.temps.t4_b.. gvl_io.unit[1].trend.temps.t4_c.. Quite a lot of unnecessary text/data taking space from the actual trend => Is there a way to access/interface the legend-data programmatically so I can change the presentation/naming?
Last updated: 2025-12-16

Post by gseidel on Can't get SMC_SmoothPath to work CODESYS Forge talk (Post)
Hi bertus, I cannot see any problem in the code you posted. Just some ideas: What is the value of D_ANGLE_TOL? - Do you need the assignment bAbort := NOT bDecoder? Does it help to leave it out? Any errors (e.g. SMC_SmoothPath.Error/ErrorID) or PLC log messages? What if you comment out SMC_SmoothMerge and SMC_LimtiDynamics, is corner smoothing still not working? Is bDecode written from a different task (e.g. visu)? Then I would recommend to assign to a local variable (bDecodeLocal := bDecode) and use that for all FBs. Otherwise, FBs might see different values of bDecode in a single cycle, which will cause problems. Regards, Georg
Last updated: 2025-12-17