Wago PLC Crashing and Cant Reconnect
CODESYS Forge
talk
(Thread)
Wago PLC Crashing and Cant Reconnect
Last updated: 2024-07-30
Post by binilraj on wago 750-841
CODESYS Forge
talk
(Post)
Hi all, Can this WAGO 750-831 be programmed by codesys v2.3? or do i need to use any other versions?.
Last updated: 2024-07-31
Post by binilraj on wago 750-841
CODESYS Forge
talk
(Post)
Hi all, Can this WAGO 750-831 be programmed by codesys v2.3? or do i need to use any other versions?.
Last updated: 2024-07-31
wago 750-841
CODESYS Forge
talk
(Thread)
wago 750-841
Last updated: 2024-07-31
Generate FBs from source
CODESYS Forge
talk
(Thread)
Generate FBs from source
Last updated: 2024-07-31
Post by askic on Generate FBs from source
CODESYS Forge
talk
(Post)
Hello, I'm coming from Siemens (TIA) world and currently learning Codesys. I'd like to know if there is an option to add external txt file with ST code for creation of a function block and then use this file as a source file from which FB will be generated? For example, in TIA, there is an option add external source file to the project structure and then use option "Generate blocks from source". This would create a FB. Does Codesys have something similar? This external source file would look like this: FUNCTION_BLOCK Scaling VAR_INPUT x, k, n : REAL; END_VAR VAR_OUTPUT y : REAL; END_VAR VAR END_VAR y := k*x+n; END_FUNCTION_BLOCK
Last updated: 2024-07-31
Post by hazarath on How extract JSONElement containing Array data
CODESYS Forge
talk
(Post)
I want to extract each element of an Array. Can someone help me with this. When I use JSONElementToString (part of JSON Utilities SL), I am seeing output as "ARRAY" instead of actual data. Here is the JSON content that I want to read : { "value1Unit": { "units": "M" }, "data": { "stepSize": 300.23, "points": [6,8] } } I would like to read each item of the element "points" i.e. 6 and 8. Here is the code I used, // Reading the content as JSON reader ( xExecute := execute , pwData := ADR ( converted_value ), jsonData := jsonDataStorage ); // Get the JSON Element jsonDataStorage.FindFirstValueByKey( wsKey := fidKeyVar, diStartIndex := searchElem, jsonElement => jsonElement ); JSON.JSONElementToString ( element := jsonElement , wsResult := valueWstring ); The content of the output of valueWstring is shown as "ARRAY" instead of the array items i.e. 6 and 8 Please can someone help me.
Last updated: 2024-07-30
POU Private variables
CODESYS Forge
talk
(Thread)
POU Private variables
Last updated: 2024-07-31
Post by stuartjr on POU Private variables
CODESYS Forge
talk
(Post)
Pretty sure I know the answer, but thought I would ask just in case. Is there a way to set variables declared in a POU to private so that they can not be accessed from other POUs. I tried using the library pragma, but that just stops the variables being displayed in the selection tree. My compiler version is 2.3.9.62 if that's relevant, and I'm using an ABB AC500 V2 PLC. Cheers
Last updated: 2024-07-31
Post by jnoyau on Visualisaion while in simulation
CODESYS Forge
talk
(Post)
Hi all, Im new to Codesys 3.5, and am in the process fo making a visualisation i'd eventually export towards a Wago device. The issue I'm having currently is that when I compile and connect to the simulated program, my simulation won't launch. On the Visualisation tab, all I get is a text message (where previously there was my prepared visualisation) that says "The visualisation awaits a connection. Start the application" One thing to note: I work with Codesys 3.5 in french, so this is a rough translation. And a second: I'm not getting any errors nor warnings about the visualisation tab itself upon compiling Is there a step i'm missing after launching my simulation? Or would it be some really specific issue caused by the way I've set up my program? Thanks, J
Last updated: 2024-07-31
Post by dawidr on Best practices for querying multiple MODBUS devices
CODESYS Forge
talk
(Post)
Hi! What are the best practices for querying multiple Modbus devices? Single PRG or maybe multiple PRG (so basically multiple thread) per each Modbus device. In my current implementation I'm using single PRG and I'm utilizing FbMbMasterMultiQuerySerial and WagoAppPlcModbus.FbDigitalTwinMbSlaveDevice in eCockpit with PFC200. I've the timer with 2 seconds delay there and it was working fine for single device. But now I have three Modbus devices and for two of them I need to run 2/3 queries to get data from all registers. I noticed that the delays for getting the data from the Modbus devices is much bigger right now.
Last updated: 2024-07-31
Best practices for querying multiple MODBUS devices
CODESYS Forge
talk
(Thread)
Best practices for querying multiple MODBUS devices
Last updated: 2024-07-31
Post by jmfernandes on OpenDir always in error
CODESYS Forge
talk
(Post)
Hello I'm trying to use DirOpen to access a directory where then I can read/list the files inside. But I can't list any files because DirOpen.xError is always true. In eError the message is this: " ERROR_UNKNOWN Local library error ID (0: no error; 5101: time out)**** " I have in the file explorer the path 'C:\CodesysTest\Aluminium' and to make sure I also created in the plc a folder to 'prj/Recipes/Aluminium'. I tried using the different paths, but in both it happens the same thing.Inside the folder Aluminium there is two csv files, that I want to list. I added in the library manager CAA Files and CAA Types. I am using the example of https://content.helpme-codesys.com/en/libs/CAA%20File/Current/Examples.html#directory but not matter what I do, I can't get the list the names of the files. What am I missing?
Last updated: 2024-07-31
Post by timvh on OpenDir always in error
CODESYS Forge
talk
(Post)
With new runtimes, the access outside the runtime folder is protected. See: https://forge.codesys.com/forge/talk/Engineering/thread/3da9ded84e/
Last updated: 2024-07-31
Post by jmfernandes on OpenDir always in error
CODESYS Forge
talk
(Post)
Hello just to give more feedback the error I get is "ERROR_UNKNOWN :represents raw value of 5110" in File.DirOpen. The xDone never gets true, and I never get the listing of files (csv files in this case). In the hDir i get the value of 0 for a DWord!?
Last updated: 2024-07-31
Post by jmfernandes on OpenDir always in error
CODESYS Forge
talk
(Post)
Thanks for the answer Tim. I am using the codesys version 3.5 SP16, is this also affected or only after version 19? But now at leastI know that is an acess problem to the file and not something else. Unfortunately the link you posted on 2023 are now dead, but I will investigate!
Last updated: 2024-08-01
Post by dantheman on Connecting to SoftPLC Only Works By Turning Off Modbus Ethernet Port
CODESYS Forge
talk
(Post)
I've also noticed that when I turn off "enp1s0", suddenly the source IP for the ModbusTCP changes to that of "enp2s0", which is what makes sense to me. When I turn it back on, the source IP remains that of "enp2s0".
Last updated: 2024-08-01
Post by dantheman on Connecting to SoftPLC Only Works By Turning Off Modbus Ethernet Port
CODESYS Forge
talk
(Post)
I have an IPC with 2 ethernet ports and 1 Wi-Fi. I'm using ModbusTCP with the ethernet port named "enp2s0" connected to my remote I/O. This works fine when testing with Python and also works with CODESYS, but CODESYS is only able to scan for the Linux SoftPLC when I turn off the "enp2s0" interface. In other words, I can't get online with the IDE if I want my ModbusTCP comms to run with CODESYS. I'm using a Linux SoftPLC that has the following entry in CODESYSControl.cfg, hoping that this will allow me to connect with "enp1s0" or "wlp3s0", and leave "enp2s0" for field comms, but this seems to only make the source IP of the ModbusTCP comms to be bound to "enp2s0". That last point is the case only if I don't restart the service, but if I do restart the service after changing the config file, the source IP for the ModbusTCP comms then becomes the one for "enp1s0", which is very confusing to me: [SysSocket] Adapter.0.Name="enp2s0" Adapter.0.EnableSetIpAndMask=1 On the device list, I only have "enp2s0" given as the ethernet device that has the ModbusTCP master & slave beneath it, shown in Screenshot 1. On the IPC, I can ping the ModbusTCP client (remote I/O) from "enp2s0", and I've attached a Wireshark capture of running ModbusTCP from the CODESYS runtime as Screenshot 2, 3 & 4 (again, I can't get online when this is running, I have to turn off "enp2s0" to connect even when it's idle and I don't have an active TCP session with my Python tests). Like I explained above, the source IP is "enp1s0", even though the ethernet device on the project is "enp2s0". I was lucky to catch the red message that showed the source IP that makes sense to me (the one for "enp2s0"), but for some reason that connection was reset and I never saw that packet again. I've also tried this with Auto-reconnect both enabled & disabled, for the ModbusTCP Master device. I also have to turn off "enp1s0" and then turn it on, just so that I can have the ModbusTCP comms running from "enp2s0" (which is not intuitive in any way to me, I'd love some help understanding that phenomenon as well) in the weird manner that I've described above. I would be very appreciative if someone can help me figure out this pickle. I'd love to just connect to CODESYS through my Wi-Fi interface and leave my ethernet ports for field comms.
Last updated: 2024-08-01
Post by jmfernandes on OpenDir always in error
CODESYS Forge
talk
(Post)
Well I created a user as Admin, gave access rigths to the file but still can't read the files in the plc it gives the same error. I guess is something to do with plc itself.
Last updated: 2024-08-01
OpenDir always in error
CODESYS Forge
talk
(Thread)
OpenDir always in error
Last updated: 2024-08-01
Number of Connections to Modbus TCP Slave
CODESYS Forge
talk
(Thread)
Number of Connections to Modbus TCP Slave
Last updated: 2024-08-01
Post by wagomikep on Number of Connections to Modbus TCP Slave
CODESYS Forge
talk
(Post)
Hello, Is there a maximum number of Masters that can connect to a Modbus Slave that is configured in the device tree? Is this limited by the CODESYS IDE, or the manufactures hardware and CPU load? Thank you,
Last updated: 2024-08-01
Post by wagomikep on Number of Connections to Modbus TCP Slave
CODESYS Forge
talk
(Post)
Hello, Is there a maximum number of Masters that can connect to a Modbus Slave that is configured in the device tree? Is this limited by the CODESYS IDE, or the manufactures hardware and CPU load? Thank you,
Last updated: 2024-08-01
Post by wagomikep on Number of Connections to Modbus TCP Slave
CODESYS Forge
talk
(Post)
Hello, Is there a maximum number of Masters that can connect to a Modbus Slave that is configured in the device tree? Is this limited by the CODESYS IDE, or the manufactures hardware and CPU load? Thank you,
Last updated: 2024-08-01
Number of Connections to Modbus TCP Slave
CODESYS Forge
talk
(Thread)
Number of Connections to Modbus TCP Slave
Last updated: 2024-08-01
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND
or OR
.