Post by trusty-squire on CNC - How to manipulate SMC_GeoInfo objects CODESYS Forge talk (Post)
Sometimes you just need to pose a question on a forum and re-read it to get clarity. pGeoInfo := SMC_GetObj(poq:=ADR(fbCncInterpreter.poqDataOut), n:=1); This won't work, I'm providing a pointer to a pointer, as poqDataOut is already a pointer! I just need to remove the ADR() and it works. pGeoInfo := SMC_GetObj(poq:=fbCncInterpreter.poqDataOut, n:=1);
Last updated: 2024-07-26

Post by tomast on Communication PLC with HMI - how to send DUT via NVL. CODESYS Forge talk (Post)
Hi everyone, I am working with project where i have DUT wihth struct. I would like to fill this data trough a form on HMI. I use NVL to communicate and i would like to know how is it possible to do this? Thanks for all your advice in advance.
Last updated: 2024-08-23

Post by kobrakaister on Migration from ISaGRAF to CODESYS CODESYS Forge talk (Post)
Hello everyone, I need to migrate my existing automation projects from ISaGRAF to CODESYS, and I'm looking for guidance and the best tools and strategies to ensure a smooth transition. Are there any reliable software tools or plugins that can help the conversion? What strategies should I adopt to maintain project integrity? Thank you for the help you can provide! Mat
Last updated: 2024-10-03

Post by rafaelbrito on Integration C Code CODESYS Forge talk (Post)
I tried to use C code in the library that I have been developing in the project, but without success. I tried to use the CODESYS Control SL Extension Package to generate XXXdep.h and XXXltf.h, but without success. Do you have a better example of how to generate these files and how to compile them?
Last updated: 2024-12-03

Post by winki on Not Possible to connect using control SL CODESYS Forge talk (Post)
Hello, I used to connect into my gateway using control SL tool 4.13, (it was called Update Linux.) I formated my computer, so today I install the new version of codesys and all package. Now I am not able to connect to my PLC using control SL. It says, check the status. Normally it used to worked perfectly before that.
Last updated: 2025-01-07

Post by timvh on Library ENUM text representation in visualization CODESYS Forge talk (Post)
Probably the enum from the library doesn't have text support. In that case you need to add your own TextList to the application. In the rectangle you should use the property "dynamic text" to link this object to the textlist which you have created yourself and then link the text index to your enum variable.
Last updated: 2025-01-09

Post by trusty-squire on Help with __SYSTEM.VAR_INFO CODESYS Forge talk (Post)
Not knowing exactly what you want to accomplish, you can try to use VAR_INPUT MyVar: POINTER TO BOOL; END_VAR MyVar contains the address of your referenced variable, and MyVar^ dereferences it allowing you to access the value. If this doesn't meet your needs, could you add more detail on what you are trying to accomplish?
Last updated: 2025-01-26

Post by jeffersonhui on SP20 Visualization Element Dynamic Colors CODESYS Forge talk (Post)
I am using Codesys SP20 patch 5 and in a visualization element, the "Color variables" section does not have a section to set up dynamic color values linked to variables. In a previous version (SP18), I get the option to add variables for Normal & Alarm state colors. Does anyone know how to get the dynamic color variables to work?
Last updated: 2025-02-19

Post by kevinm on Attaching Trace variable to Frame Configuration Variable CODESYS Forge talk (Post)
Is it possible to show a variable from a Frame Configuration in a Trace on that Visualization? I want to pass the FB for an AXIS_REF_ETC_SoE_Standard to the visualization and display live axis data in the visualization. However, I cannot find a way to use a Frame Configuration variable in the Trace Configuration dialog.
Last updated: 2025-04-04

Post by aniket-b on How to protect library project? CODESYS Forge talk (Post)
I have library projects which has few function blocks. I have assigned security to each FB. I want to protect them and user can only be able to use it without viewing the code inside. What kind of file I should send to user? Is it compiled library file?
Last updated: 2024-01-22

Post by dhumphries on WAGO PLC 200 750-8216 Ethernet connection to Codesys 3.5 CODESYS Forge talk (Post)
make sure the PLC and the programming PC have IP addresses that are on the same subnet, you'll have to know the default address of the PLC or you may need to connect to it with a special cable and use a software tool to set the IP address.
Last updated: 2024-02-06

Post by i-campbell on Not able to see input data coming from eip adapter on codesys CODESYS Forge talk (Post)
Hello, I think you can try to change the Connection from Multicast to Point to Point. Please also make sure your windows firewall is allowing the correct UDP ports inbound for ethernet IP. You might also need to increase the RPI, so it times out slower.
Last updated: 2024-03-07

Post by fless on How to change bHiresMode CODESYS Forge talk (Post)
you need to set the increments to 10 (the screenshot shows 10000 hex = 65536). all the turn settings to 1. and the application units to 366. But usually you use the resolver resolution per motor turn. Insert the gear ratios (1:1 for no gear) and the last field you put the circumference of your drive wheel.
Last updated: 2024-03-12

Post by riku on Download CODESYS Scripting package CODESYS Forge talk (Post)
Hey there! Is it possible to download the "CODESYS Scripting" package outside of the "CODESYS Installer"? Or is there a alternative way to download the python files for the scripting engine? I want to setup a test environment to write test scripts and therefore want to have those python scripts for e.g. autocompletion. Thanks in advance!
Last updated: 2024-03-16

Post by thewizard8 on Raspberry PI4 Serial Port CODESYS Forge talk (Post)
Hi All, I finally figured out how to solve it. The only away that I got it to work was to define parity to None on modbus configuration, and now works like a charm. Just for the record I'm using the GPIO port pins (8,10) and a RS485 to ttl shield that you can find online. Thanks all for the support! Regards Ricardo
Last updated: 2024-03-19

Post by jinlee on V3.5 SP19 patch 2. Out of retain memory CODESYS Forge talk (Post)
Hi guys, I am quite new Codesys. Be patient to me. I am having a problem now. Please refer to the attached photo. Is there a way to increase the memory ? If no, what is the way to solve this problem ? My retain variable list is in one place. Please refer to the attached photo. Thank you very much.
Last updated: 2024-03-20

Post by saugat10 on I have errors while building the project CODESYS Forge talk (Post)
I have some errors as you can see in the picture when i build the project. I have not been able to trace back to the error and i have no idea where to look at to fix this issue. What is GVL_Io? Is it related to some library?
Last updated: 2024-04-10

Post by tomas111 on Black background when loading webvisu CODESYS Forge talk (Post)
Tell me, are there ways to remove the white background from the page loading? I want to change it to a black background. I think there are options with changing /home/codesys_root/PlcLogic/visu/webvisu.htm Perhaps you have already encountered a similar situation. I hope to find the answer to my question.
Last updated: 2024-04-17

Post by fjgonzalez on Timer On Vijeo CODESYS Forge talk (Post)
Hi. I'm trying to show in Vijeo Designer a timer countdown. But I want to display the data in hour, minutes and seconds. I tried to change the data by converting in the Machine Expert but not able to succeed. Can you help me to find a solution? Regards, FG
Last updated: 2024-05-07

Post by mascara on CloseTargetVisu CODESYS Forge talk (Post)
I need to add a button to the Visualization to close it. And create a shortcut on the Windows desktop to reopen the Visualization. This is necessary to configure, for example, a local IP address. Is this possible? What command closes the Visualization? Which program opens Visualization? System: Win10 Codesys: Control RTE V3 x64 Program: Codesys V3.5 SP20 Using only a touchscreen monitor, without keyboard and mouse.
Last updated: 2026-03-11

Post by reinier-geers on Virtual Api to vieuw what im sending CODESYS Forge talk (Post)
Hi. Is there a website to test my webclient ? When i do a web api test on internet it works. But with codesys ill get an error. So is there a website to tests what im sending ? or a way to look in to the Codeys FB Webclient ?
Last updated: 2026-04-05

Post by reinier-geers on Virtual Api to vieuw what im sending CODESYS Forge talk (Post)
Hi. Is there a website to test my webclient ? When i do a web api test on internet it works. But with codesys ill get an error. So is there a website to tests what im sending ? or a way to look in to the Codeys FB Webclient ?
Last updated: 2026-04-05

Post by otbeka on CAA File Handling: "Read only" error CODESYS Forge talk (Post)
Hi, On CODESYS V3.5.19.50 I am using the latest 3S File Access library (CAA File & CAA Types) to save and retrieve configuration data from the User Data section of an SD card, via file called config.txt. The application reads the file to memory once upon initialisation, and then the only other operation is overwriting the file with the updated configuration whenever the user changes the settings. An issue is ocurring, seemingly randomly, where the config.txt file, and all surrounding directories, cannot be written to by the unit, returning a READ_ONLY_CAA error upon file open. This sometimes does not clear even after power-cycling the PLC several times, yet checking the file permissions with ls -l shows normal read, write, and execute access. I am wondering if this is caused by the PLC itself or by an issue in my application. I have included my CAA File handler function block (SD_Card_Bin(FB).txt) and any associated types/calls below: TYPE ConfigData : STRUCT Config : ARRAY[0..256] OF STRING(64); NumberOfStrings : UDINT; END_STRUCT END_TYPE TYPE Buffer : STRUCT Data : ARRAY[0..SIZEOF(ConfigData)] OF BYTE; DataLength : UDINT; END_STRUCT END_TYPE A case within my MAIN PRG: mode.WriteConfigDataToFile: VisuElems.CURRENTVISU := 'Screen_Write'; IF xModeHasChanged THEN iErrorCount := 0; iRoute := 0; END_IF CASE iRoute OF 0: inBuffer := ConfigData_To_Buffer(GVL.UnitData); xConfigError := FALSE; xDataConfigured := FALSE; iRoute := 1; 1 : //Read Data from Card SD_Card_Bin.strFileName :=FileName; SD_Card_Bin.iFileOperation := 2; SD_Card_Bin(xExecute :=TRUE, WriteBuffer := inBuffer, xDone =>xDataConfigured, xError=>xConfigError, strErrorCodes=>strError); IF xDataConfigured THEN SD_Card_Bin(xExecute :=FALSE); IF xConfigError THEN iRoute := 32767; ELSE iRoute :=100; END_IF END_IF 100: // The end bCurMode := mode.DisplayProcessVariables; 32767: // Config error iErrorCount := iErrorCount + 1; IF iErrorCount > 2 THEN // Repeats 3 times, if no progress abandons and returns error bCurMode := mode.WriteError; ELSE iRoute := 0; // Try again END_IF END_CASE I'd like to rule out my application as the cause of this bug - help via comments or criticism would be greatly appreciated.
Last updated: 2025-03-19

Post by lorenzo-pisoni on SysProcessExecuteCommand CODESYS Forge talk (Post)
Hello, I'm encountering an issue with the Sysprocess library while attempting to execute commands to transfer a file from a NAS to my PLC. Currently, I'm trying to test a simple "reboot" command, but it doesn't work as demonstrated in this video: https://youtu.be/77c7Af5xRhE?si=uFZdB6fTNQitzWMQ. I'm using CODESYS V3.5 SP18 Patch 4 (3.5.18.40). From other sources, I've learned that to enable the PLC to execute commands, I need to add the following line to the file CODESYSControl_User.txt: [SysProcess] Command=AllowAll However, the issue I'm facing is that this file doesn't exist on my CPU. I have full SSH access and can see all files, but only CODESYSControl.txt is present. Adding the command to CODESYSControl.txt hasn't resolved the problem.
Last updated: 2024-07-11

Post by bjarne-pagaard on Global Variables CODESYS Forge talk (Post)
Old thread, I know - but it still has good answers. I would like to add a bit of info to it, as I was having a problem that lead me to this thread, but didn't give an exact answer. I am porting a project to a different PLC architecture. (Wago PFC300) A GVL named 'GVL' in the POUs section of my project was shadowed by a PLC-specific library in the Application->Library Manager. So all the existing references in the device specific code to 'GVL.something' would not resolve. Right-clicking the GVL in the code and 'Go to definition' would point me to the library in the Application Library Manager. All I had to do from there, was right-click the library, and set the property 'Only allow qualified access to all identifiers' in the library.
Last updated: 2025-04-11