Post by eschwellinger on Identifier 'IoDrvGPIO' not defined
CODESYS Forge
talk
(Post)
it is just a precompiler error, login an start the application. Works.This will be fixed hopefully to next version.
Last updated: 2024-04-10
Post by joshskellig on Publish a JSON payload via MQTT Publish (using IIot Libraries)
CODESYS Forge
talk
(Post)
Thanks for the help! Everything now works as expected.
Last updated: 2024-04-10
Post by joshskellig on Publish a JSON payload via MQTT Publish (using IIot Libraries)
CODESYS Forge
talk
(Post)
Thanks for the help! Everything now works as expected.
Last updated: 2024-04-10
IIoT Library Payload Limit
CODESYS Forge
talk
(Thread)
IIoT Library Payload Limit
Last updated: 2024-04-11
AWS IoT core CODESYS
CODESYS Forge
talk
(Thread)
AWS IoT core CODESYS
Last updated: 2024-04-10
Post by mmpl on AWS IoT core CODESYS
CODESYS Forge
talk
(Post)
It is looks like there is problem with your JASON conversion. If you share picture of your payload conversion will give more information.
Last updated: 2024-04-10
Post by eschwellinger on Problem retain values Weidmuller UC20-WL2000
CODESYS Forge
talk
(Post)
I would recommend to check the plc log to have more detailed information.
Last updated: 2024-04-11
Post by rmaas on Fieldbus has lost synchronicity
CODESYS Forge
talk
(Post)
Hi, On a gantry system with 2 axis i am getting the following error: SMC_DI_FIELDBUS_LOST_SYNCRONICITY This happens random, sometimes it happens every 5 minutes and sometimes no error for 2 hours... The Setup: - Using codesys 3.5 SP20 with all latest libs... - Kontron AL Pi-Tron CM4 with Preempt realtime patch (Raspberry Pi 4) - Codesys runtime 4.11.0.0 (single core) - CODESYS Control for Raspberry Pi SL licensed - Softmotion + CNC + Robotics licensed - 2x Leadshine EL8-EC400 servo drives - Axis group for a 2-axis T-Gantry Ethercat network wiring: Ethercat master softmotion -> Beckhoff EK1100 -> Servo drive #1 -> Servo drive #2 Ethercat Cycle time = 4ms Max Jitter = 140~150 What i have tried so far: - changed the sync offset from 20% to 30% - changed ethercat task priority from 1 to 0 Running tasks: - Ethercat tast: Prio = 0, Interval = 4ms - Main task: Prio = 1, Interval = 8ms - Visu task: Prio = 31, Interval = 100ms - Softmotion planning task: Prio = 15, Freewheeling - 3 other default tasks that were created by AC_Persist Motion fb's are called in the ethercat task... Does anyone have an idea how to fix this? Any help is greatly appreciated!
Last updated: 2024-04-11
Post by dkugler on build (F11) / generate code using a python script file
CODESYS Forge
talk
(Post)
thank you very much! I found the generate_code methode, but struggled with the primary and active_application. With this expample I will be able to play around. If the code generation takes a minute or more I often switch to other programs and don't notify the process is finished. So now I'll get an alert and will switch back immediately. My next little project will be, to beep different if there are errors and a seperate script to do the download incl. the user management data base without stopping at the dialogs asking for onlinechange/complete download and overwriting an existing database and as goody, play a beep/sound again.
Last updated: 2024-04-11
Post by rossanoparis on RevPi CONNECT+, CODESYS, EtherCAT master "Filedbus lost synchronicity"
CODESYS Forge
talk
(Post)
Hello @rmaas I assume, you've already verified and tuned everything regarding the EtherCAT network. In my case the problem was due to a wrong core assignement. I suggest to not use the core #0 for your EtherCAT task. The OS realtime patch, which is present on RevPi OS, uses the core #0 for its porpouses and it mustn't be used by any other task which requires realtime and deterministic features. regards Rossano
Last updated: 2024-04-11
Post by tk096 on Fieldbus has lost synchronicity
CODESYS Forge
talk
(Post)
Hi, a few suggestions on how to tackle the problem: - it might help to increase the cycle time of the ethercat task - increase the value of the ethercat parameter DCInSyncWindow (https://content.helpme-codesys.com/en/libs/IODrvEtherCATDriver/Current/pou-IoDrvEtherCAT/DCInSyncWindow.html) (see attached image) - enable FrameAtTaskStart (https://content.helpme-codesys.com/en/libs/IODrvEtherCATDriver/Current/pou-IoDrvEtherCAT/FrameAtTaskStart.html) in the ethercat master (see attached image) - if the drives can handle the synchronization problems, checking of the synchronization can be deactivated using SMC_Set_ETC_DCSyncSupervision (https://content.helpme-codesys.com/en/libs/SM3_Drive_ETC/Current/SMC_Set_ETC_DCSyncSupervision.html).
Last updated: 2024-04-11
RevPi CONNECT+, CODESYS, EtherCAT master "Filedbus lost synchronicity"
CODESYS Forge
talk
(Thread)
RevPi CONNECT+, CODESYS, EtherCAT master "Filedbus lost synchronicity"
Last updated: 2024-04-11
build (F11) / generate code using a python script file
CODESYS Forge
talk
(Thread)
build (F11) / generate code using a python script file
Last updated: 2024-04-11
Post by rmaas on RevPi CONNECT+, CODESYS, EtherCAT master "Filedbus lost synchronicity"
CODESYS Forge
talk
(Post)
Hi Rossano, Did you ever find a solution to this issue? It seems i am facing the same issue but i do not use OPCUA... Best Regards, Rinie Maas
Last updated: 2024-04-11
Post by eschwellinger on Problem mit control runtime V3 und profinet
CODESYS Forge
talk
(Post)
Hallo Tim, man hat halt einfach mit der Control Win - keine wirkliche harte Echzeit. Man müsste den Fehler genauer analysieren + ich denke er müsste den Slave wieder an den Busholen oder fällt ads ganze Netzwerk aus? Welche Versionen genau sind im Einsatz? Ist das halbwegs aktuell (PN 4.4.0.0?) Grüße Edwin
Last updated: 2024-04-11
Post by flavinhofh on Beaglebone Black OPC-UA Server
CODESYS Forge
talk
(Post)
ah ok, I will keep trying, I already removed all security from the Server side. I'm new on codesys and I don't know yet how to implement the certificates, but I will find out and also try. thanks for your reply.
Last updated: 2024-04-11
Post by tim-roelant on Problem mit control runtime V3 und profinet
CODESYS Forge
talk
(Post)
Hallo Edwin, meinst du das der control-win nicht wie SPS verwendet werden kann? Das program ist klein, und realtime brauch ich gar nicht, Es gibt im bus einem Turck inselstation mit 16 ein und ausgange, und ein MTS linearencoder, womit wir teile messen und abschneiden. Die cycluszeit reist auch nicht aus. Processorleisung bleibt unter 20%. Es geht mir darum das der profinet master in fehler geht, und nicht mehr seine telnehmer erkannen kann. Es kan passieren nach 10 minuten, aber auch nach 5 tage. Nur ein kaltstart bringt die bus wieder am laufen. (kein reconnect mochlich, auch die bus scannen functioniert nicht mehr) Wann ich aber ein ipscan durchfure mit Angryip auf der rechner sind alle telnehmer da. Ich habe noch eine andere application mit die gleiche anwendung, aber wo ein raspberry pi die SPS rolle spielt, und das functioniert einwandfrei. Soll ich fielleicht das OS von Rechenr nach linux umrusten? Der operator ist im moment sehr unzufrieden mit die "upgrade" von maschine... :-( lg Tim
Last updated: 2024-04-11
Post by tim-roelant on Problem mit control runtime V3 und profinet
CODESYS Forge
talk
(Post)
Hallo Edwin, meinst du das der control-win nicht wie SPS verwendet werden kann? Das program ist klein, und realtime brauch ich gar nicht, Es gibt im bus einem Turck inselstation mit 16 ein und ausgange, und ein MTS linearencoder, womit wir teile messen und abschneiden. Die cycluszeit reist auch nicht aus. Processorleisung bleibt unter 20%. Es geht mir darum das der profinet master in fehler geht, und nicht mehr seine telnehmer erkannen kann. Es kan passieren nach 10 minuten, aber auch nach 5 tage. Nur ein kaltstart bringt die bus wieder am laufen. (kein reconnect mochlich, auch die bus scannen functioniert nicht mehr) Wann ich aber ein ipscan durchfure mit Angryip auf der rechner sind alle telnehmer da. Ich habe noch eine andere application mit die gleiche anwendung, aber wo ein raspberry pi die SPS rolle spielt, und das functioniert einwandfrei. Soll ich fielleicht das OS von Rechenr nach linux umrusten? Der operator ist im moment sehr unzufrieden mit die "upgrade" von maschine... :-( lg Tim
Last updated: 2024-04-11
Post by reinier-geers on License problem gateway
CODESYS Forge
talk
(Post)
It doesnt see the dongel on my computer
Last updated: 2024-04-11
Post by thomaspfrimmer on Can't import enums OnlineChangeOption / ResetOption
CODESYS Forge
talk
(Post)
Hello Jusito, Can you share your final code, please ? I tried to implement a similar feature (going online, doing the reset and the start). But I get a timeout on the reset/start when I'm testing the script. If you got something working, I would appreciate to see it.
Last updated: 2024-04-11
Can't import enums OnlineChangeOption / ResetOption
CODESYS Forge
talk
(Thread)
Can't import enums OnlineChangeOption / ResetOption
Last updated: 2024-04-11
Post by tim-roelant on Problem mit control runtime V3 und profinet
CODESYS Forge
talk
(Post)
Wann ich ein scan mache bekomme ich keine teilnehmer, mit ein ipscan sind alle da. Die version von Ethernet & Profinet master ist 4.3.1 (oder muss ich besser codesys actualisieren nach letzten stand?
Last updated: 2024-04-11
Post by idir93dz on Identifier 'IoDrvGPIO' not defined
CODESYS Forge
talk
(Post)
Thanks a lot.
Last updated: 2024-04-11
Problem mit control runtime V3 und profinet
CODESYS Forge
talk
(Thread)
Problem mit control runtime V3 und profinet
Last updated: 2024-04-11
Identifier 'IoDrvGPIO' not defined
CODESYS Forge
talk
(Thread)
Identifier 'IoDrvGPIO' not defined
Last updated: 2024-04-11