Post by eschwellinger on Unable to deploy "Control for Linux SL 4.18.0.0" CODESYS Forge talk (Post)
Hi could you check if this really exists in 4.19.0.0 deploy tool? In your case architecture is missing- see my configuration
Last updated: 2026-02-17

Post by kunal-pinetics on USB Communication for IP Configuration & Application Update – STM32H Series PLC CODESYS Forge talk (Post)
Hello everyone, I am currently working on a PLC device based on the STM32H series MCU, running CODESYS. At the moment, I can: Change the Ethernet IP address Update/download the PLC application via Ethernet without any issues. However, I would like to implement the same functionality over USB (or Serial via USB) instead of Ethernet. My goals are: Change the device’s Ethernet IP address via USB Download/update the PLC application via USB communication Possibly use USB as a service/programming interface The hardware platform is based on STM32H series, and I am looking for guidance on: Whether CODESYS supports USB device communication for runtime download If a custom USB CDC (Virtual COM Port) implementation is required Whether a specific CODESYS runtime configuration is needed If a bootloader approach is recommended for application updates via USB If anyone has experience implementing USB communication for runtime download or device configuration on an STM32-based PLC, I would really appreciate your guidance. Thank you in advance for your help.
Last updated: 2026-02-26

Post by akneer on HMI über Webbrowser CODESYS Forge talk (Post)
Beispiel: IF bShutdownPC THEN bShutdownPC := FALSE; // LINUX SysProcess_Implementation.SysProcessExecuteCommand( pszComand:='shutdown -h 0', pResult := ADR(udiError)); // WINDOWS SysProcess_Implementation.SysProcessExecuteCommand( pszComand:='shutdown.exe -s -t 05', pResult := ADR(udiError)); END_IF
Last updated: 2026-03-04

Post by fpawlak on How to register own component - CMAddComponent() or CMAddComponent2() CODESYS Forge talk (Post)
Hi, so really oneone has no idea which way is correct one? Or maybe both are okey if they work for me?
Last updated: 2026-03-13

Post by pernockham on Gateway in China - "Gateway not connected" CODESYS Forge talk (Post)
Finally sorted (unit in China). The problem was related to dns-setting of the gateway/host. Connection (also inside china) tested/works.
Last updated: 2026-03-18

Post by thomasrek31 on Textfield display problem CODESYS Forge talk (Post)
Hello, have you found a solution? It seems I have the same problem as you. I can't remove the overlay, otherwise certain functions stop working.
Last updated: 2026-03-23

Post by thomasrek31 on Textfield display problem CODESYS Forge talk (Post)
Hello, have you found a solution? It seems I have the same problem as you. I can't remove the overlay, otherwise certain functions stop working
Last updated: 2026-03-23

Post by ulvis on CAA 3.5.16 TLS configuration - certificate CODESYS Forge talk (Post)
Hi, did yo have any luck with this? I am facing the same challenge. Using a WinCTRLx64 but I get AccessViolation error in my CmpTlsCreateContext() call.
Last updated: 2026-03-23

Post by lukasz on Unresolved reference when trying to upload to Codesys Runtime V3 CODESYS Forge talk (Post)
Hello! I'm working with Codesys SP21 Patch 4. The project builds without any errors. When trying to upload my project to Codesys Runtime V3 x64 I get a lot of Unresolved Reference errors, all with FU- at the start and then -CLOSELAYER2, -GETBUSINFO, -GETFRAME etc. I also get a error pop-up that I should 'update device' in the project but it's not specified to which version or anything useful really.There's also not much to choose from. When I check Runtime version in the systray I get 3.5.21.40 and it's the same as I have set up in the project as the device. All information I get is that it should be clear from the errors but no useful information is provided in the errors. Do I need to install some library? I checked other posts and for different reference error and this was the answer. Thanks in advance!
Last updated: 2026-03-25

Post by nulltrace on How change Unity-ID in TCP Modbus Slave CODESYS Forge talk (Post)
Hey Husarz, thanks for your Message, now i understand your Problem, also able to reproduce that. Pls. give me a Short Time to Check some stuff on this, i'll come back to this Topic with news ASAP. Greetings
Last updated: 2026-04-03

Post by struland on Sysfile Konfiguration CODESYS Forge talk (Post)
Bei mir half: [SysFile] IecFilePath=/mnt/sdcard Allerdings ist es kein Raspi. Den Ordner, der gelesen werden soll mal auf korrekte Zugriffsrechte prüfen. Im Falle das SELinux aktiv ist mit ls -lZ, ansonsten ls -al
Last updated: 2026-04-13

Post by struland on Sysfile Konfiguration CODESYS Forge talk (Post)
Bei mir half: [SysFile] IecFilePath=/mnt/sdcard Allerdings ist es kein Raspi. Den Ordner, der gelesen werden soll mal auf korrekte Zugriffsrechte prüfen. Im Falle das SELinux aktiv ist mit ls -lZ, ansonsten ls -al
Last updated: 2026-04-13

Post by nulltrace on How change Unity-ID in TCP Modbus Slave CODESYS Forge talk (Post)
Hey, I also waiting for feedback from Mr. Schwellinger @eschwellinger, please send me an answer, i would appreciate it. The clue is, i know the solution, but have to check if it's allowed to share.
Last updated: 2026-04-14

Post by reinier-geers on Resize and position Numpad/Keypad CODESYS Forge talk (Post)
HI, I download the scale dialog. But cant find were i can Set the size of the dialogs. only the position. I want the diolog bigger
Last updated: 2026-04-15

Post by husarz17 on How change Unity-ID in TCP Modbus Slave CODESYS Forge talk (Post)
Good to know there's a solution to this problem. I hope you'll be able to share it with me. I can't wait to hear about it.
Last updated: 2026-04-20

Post by malie on Issue with library updates CODESYS Forge talk (Post)
Hello, i got the same problem, but on my site it started with version 3.5.21, with version 3.5.19.7 it worked like a charm. How get the old behavior back? Or how to reload the librarys in an open project/library manually?
Last updated: 2026-04-24

Post by reinier-geers on Network variable stops sending CODESYS Forge talk (Post)
What version. 20.5 ? ive got also problems wiyth that version. Online change, it hangs itself after one hour. Then one project can problems. Ive change display with 21.0 . At home i turned on the 20.5 display. After 1 hour i goes to stop.
Last updated: 2026-05-06

Post by alex-n on Problem with keeping up the distance between two axes CODESYS Forge talk (Post)
We use Inovance AC802 as PLC, IS810N Drive, library 4.10, connection via Ethercat and no any suprise at work.
Last updated: 2026-06-02

Whether You’re New to Nursing or a Seasoned Pro, Grasping the Basics of NURS FPX 4055 Assessment 1 Offers Many Benefits CODESYS Forge talk (Thread)
Whether You’re New to Nursing or a Seasoned Pro, Grasping the Basics of NURS FPX 4055 Assessment 1 Offers Many Benefits
Last updated: 2026-06-13

Post by eschwellinger on Linux ARM64 Deploy Fail - Index out of range CODESYS Forge talk (Post)
Which Deploy Tool version is installed? the ssh login does work? If yes could we get a screenshot of the device information see my example:
Last updated: 6 days ago

Post by arj3090 on Linux ARM64 Deploy Fail - Index out of range CODESYS Forge talk (Post)
I used Tools->Deploy Control SL in the IDE that I downloaded yesterday. So I assume it is the latest version. I did a manual install using SSH and it works.
Last updated: 6 days ago

Post by patrik on Wish: CODESYSControl.cfg - again CODESYS Forge talk (Post)
Really good post. I hope that it gets seen by CoDeSys staff. I often find the documentation lacking when it comes to using CoDeSys in more complex ways. If using standard "basic PLC functionality", then it's fine and functions are documented in a sufficient way. Once you go outside of that bubble then I find the documentation not enough. CODESYSControl.cfg is a good example of this. And why isn't more of this integrated in the IDE. like changing port of the webserver. Why is it hidden in this file and not accessible through the IDE. It feels like a layer of complexity purposely left in so you don't change it if you don't know what you are doing. Like the argument is if you have the know-how to find the file you have the know-how to edit it. I find the documentation lacking when it comes to more complex libraries too. Like the element collections library. there is parameters I still don't quite know what they do. I can't find any documentation about them. There is an example project to download from CoDeSys so you can see how you are supposed to set your factories up. I leave some parameters like it is in the example. Should I? I don't know. Does it work. Yes. But I could perhaps create memory leaks if I get something wrong and I don't see that until way later. In the create method of your element factory you have a function called __vfinit and you just have to accept that it works. Why can't I get insight in what it does through documentation? Don't CoDeSys want us to know how these work so we can't use them to accidentally break something? I find the error logging lacking too. I've had the CoDeSys service crash but it doesn't say why. I've seen windows noticing the crash but no error code was sent or error message. Also in my current issue where the application fails to start after power outage. I can see in the log that it fails to load retain in the application as one log entry and application failing to start as another. But why? Why does loading the retain fail? give me more information! Is it just a skill issue with me? I don't know. If it is then I'd still want CoDeSys to step up their game when it comes to documentation. I'm sorry if a lot of frustration comes though in this post. I really like the product and what I can do with it compared to other PLC brands.
Last updated: 2024-11-21

Post by steven-schalm on Github Actions CI/CD tasks - development topic CODESYS Forge talk (Post)
hello kevinrn, I've been looking for a solution to the CI/CD issue for a long time. Briefly about me... I am 32 and software architect for Codesys V3 and fullstack dev for web (VueJS, NestJS) in a small company in Erfurt (Germany). https://www.rex-at.de/. Through my web part, we already have CI/CD running well via GitLab (YAML-based configuration file (.gitlab-ci.yml), which defines which pipelines and jobs are executed when certain events occur) with everything you know. Stages for npm packages - prepare (GitVersion, npm install or whatever) - build (vite, tsc or whatever) - testing (vitest, jest or whatever) - deploy (npm packages) And similar for monorepo's or backend services (in NestJS) as DockerImages. For Codesys we have been building an OOP framework for years (~50 libraries now), which is currently managed via SVN and a specially written Svn-Watcher (in Python) gets commits and runs and builds everything together and deploys it to an FTP server and network drive. Why do we still have SVN? Because we are unfortunately still tied to the safety integration of Codesys and can therefore only go to SP15 at most with our controller/Eckelmann. But soon there will be an update and there will be no more obstacles to using Git. Hence my questions: 1. the basic idea is to run a local Windows Runner on some machine? 2. install Codesys on the machine where the runner is running? 3. powershell & python scripts are then used to execute builds (compile, build, sign libraries) & deploys? 4. can the Github action also be used in GitLab? ChatGPT has already told me that it's not the same, but it doesn't hurt to ask. Do you have any ideas on this? Greetings :D
Last updated: 2024-08-20

Post by fmon on Modbus : dis- / re-connect cable: modbus does not re-start CODESYS Forge talk (Post)
Hello, I am using codesys Modbus TCP client (4.4.0.0) to communicate with a python modbus server (package pyModbusTCP). I first start my python server on the distant machine. After a fresh codesys compilation, a plc connection/transfer and a PLC run, the modbus connection is OK. Every time in this context the connection is created correctly. When I shut down the server, the modbus connection falls, that is normal. When I restart the python server, impossible to recreate the modbus connexion. With the client autoreconnection, I see on my server that the client tries to connect but unsuccesfully. I have the following message : DEBUG:pyModbusTCP.server:accept new connection from ClientInfo(address='192.168.1.20', port=33476) DEBUG:pyModbusTCP.server:Exception during request handling: NetworkError('recv return null') I tried to stop the codesys client and to restart it with these commands : Modbus_TCP_Client.xStop := True; // Or False Modbus_TCP_Client.Enable := True; // Or False Modbus_TCP_Server.Enable := True; // Or False I tried to confirm the error manually to force reconnection with: Modbus_TCP_Server_Motors.xConfirmError := TRUE; I tried also this command to STOP/RESET/START client and server (codesys side) but nothing happens : status_client := Modbus_TCP_Client.SetCommunicationState(eRequestedState := DED.DEVICE_TRANSITION_STATE.STOP); // .RESET & .START The answer of this function when executed is "status_client = NOT_SUPPORTED" It seems that is a socket problem, but I do not understand if it is on the client or server side. I tried a modbus simulator called "ananas.exe" and the result is the same. Impossible to get a modbus reconnection. What is different at the first connection and at a reconnection attempt ? Thanks for your help
Last updated: 2025-03-14

Post by gilad on CODESYS SoftMotion Generic DSP402 on WAGO PFC200 + Festo CMMT-AS: MC_Power stays Busy, Controlword remains 0 CODESYS Forge talk (Post)
Hello, I am trying to connect a Festo CMMT-AS-C4-3A-MP-S1 servo drive to a WAGO PFC200 (750-8210) using EtherCAT and CODESYS SoftMotion. Hardware PLC: WAGO PFC200 750-8210 Drive: Festo CMMT-AS-C4-3A-MP-S1 Communication: EtherCAT CODESYS version: Device description version 6.3.1.1 Drive firmware: 36.10.3 Current Status EtherCAT communication is working correctly: EtherCAT master = Running Drive detected and operational PDO input and output mapping is active Statusword, position and velocity are updating correctly Current PDO mapping: Outputs: 6040 Controlword -> %QW0 6060 Modes of operation -> %QB2 607A Target position -> %QD1 60FF Target velocity -> %QD3 Inputs: 6041 Statusword -> %IW2 6061 Modes of operation display -> %IB6 6064 Position actual value -> %ID2 606C Velocity actual value -> %ID3 SoftMotion Axis I added a SoftMotion CiA402 axis under the EtherCAT slave: Axis type: SM_Drive_GenericDSP402 Axis communication state: operational (100) No SoftMotion mapping errors anymore Problem MC_Power is executed with: Enable = TRUE bRegulatorOn = TRUE bDriveStart = TRUE but: Status = FALSE Busy = TRUE Error = FALSE ErrorID = SMC_NO_ERROR The axis remains in: SMC_AXIS_STATE.power_off DSP402 state = SWITCH_ON_DISABLED The most important observation: Statusword = 32784 (0x8010) Controlword (%QW0) remains 0 all the time SoftMotion never writes 6, 7, or 15 to the Controlword. Additional Information The axis status page reports: "The license is missing or invalid. The PLC runs in demo mode." I am not sure whether: The missing SoftMotion license prevents Controlword generation completely. The axis is still not correctly connected to the EtherCAT slave despite operational communication. There is an additional CiA402 configuration step required for the Festo CMMT-AS drive. Has anyone successfully used a Festo CMMT-AS MP drive with CODESYS SoftMotion Generic DSP402 on a WAGO PFC200? Any suggestions on what should be checked next would be greatly appreciated.
Last updated: 2026-06-24