Post by gseidel on Dynamic target position tracking CODESYS Forge talk (Post)
Hi kporter, a more direct way would be to use SMC_FollowPosition to write the set positions directly to the servo drive. This FB has reacts on changes of the fSetPosition on each call, without a need for a rising edge on Execute. See https://content.helpme-codesys.com/en/libs/SM3_Basic/Current/SM3_Basic/POUs/Movement/Direct/SMC_FollowPosition.html. Best regards, Georg
Last updated: 2025-09-08

Post by kio123 on SysFileOpen not working CODESYS Forge talk (Post)
I have exactly the same problem and tried entering “ForceIecFilePath=0” in the file “CODESYSControl.cfg” ([SysFile]). Unfortunately, this was unsuccessful. Can anyone help in the meantime, e.g., with some sample code or with the FAQ that TimvH refers to above (link no longer works)? Many thanks and best regards
Last updated: 2025-09-15

Post by blitz on Latch alarm variables from the PLC runtime CODESYS Forge talk (Post)
Hi, I have a question. Does anyone know a way to change latch alarm variables from the PLC runtime? In the help there is a method described: https://content.helpme-codesys.com/en/libs/AlarmManager/Current/Interfaces/pou-IAlarm3/SetLatchVarValue.html but I don’t know how to use it correctly.
Last updated: 2025-09-23

Post by cer-wa on Not able to connect multiple profinet encoder in codesys Linux ARM64 CODESYS Forge talk (Post)
Hello, currently im working with a RevPi connect 5 on a codesys project. Up until now I was having a blast because things were going really smooth but for like almost a day im kind of stuck on the integration of multiple profinet sensors into my project. This is kind of a bummer because that should be an easy thing to do. What I tried so far was to create and additional ethernet adapter where I then tried to connect my devices. in the beginning I tried to connect the devices directly which was not working because I could assign the IP-adress only to the ethernet adapter and not to the devices but the device was found in the device repository (this gets important in the second part) So what I tried next was to setup a PN-Controller and connect my devices subsequently to the Controller. Sadly now the devices wont show up in the device repository anymore. To me its not clear why this is happening. And the worst thing is: I went ahead and setup a device completely like I would want to have it in the project and when I then click on scan devices I can even find the device. But it can not be added to project for whatever reason eventhough im 100% certain that the gsdml file is the correct one. Can anyone help me with this. Like I said this seems like an easy thing to do and its taking me way longer than expected already. The only thing that came to my mind why this might not work is because I have codesys license which only allows one profinet instance. Could that be the case? The error message seems then pretty unfit but ok. I will be grateful for every advice. Thanks in advance! Best regards!
Last updated: 2025-09-25

Post by pernockham on Gateway in China - "Gateway not connected" CODESYS Forge talk (Post)
Gateway and runtime (Control for linux SL) on a debian linux. Thanks for your check. Good to know. I will probably travel there in about a months time so that will give me better possibility for further testing. (on a side note, I dont get mail-updates on forum-subscriptions, need to check the topics manually)
Last updated: 2025-09-26

Post by jy77812 on Visualization XY Charter Question CODESYS Forge talk (Post)
Hello. I'm using Visualization XY Chart, and when I mark a circle through XY position data, a blue line is displayed in the circle with a red circle. At this time, can't I set the blue line not to be seen in the circle? Currently, whenever XY position is drawn, the line follows.
Last updated: 2025-10-02

Post by dogulas on numeric text box control CODESYS Forge talk (Post)
Ok, this is how I made a numeric text field: use a Text Field properties -> Texts -> Text := %f (or %d or whatever you need) properties -> Text variables -> Text variable := (your numeric variable) properties -> Input configuration -> OnMouseDown -> Configure: Write Variable Input type := VisuDialogs.Numpad Use another variable (your numeric variable) Min val Max val etc. Please tell me there is an easier way to do this.
Last updated: 2025-10-02

Post by jzhvymetal77 on Special Chars in Visualizationfor QR code string CODESYS Forge talk (Post)
Ok, I got UTF-8 encoding working by encoding the full block character using [16#E2, 16#96, 16#88], which corresponds to U+2588 "█". Moving forward, I’ll use this for creating a QR code with Version 10-M (byte mode). This version allows up to 213 characters to be encoded.
Last updated: 2025-10-04

Post by e13740e on Сalling the context menu from the keyboard CODESYS Forge talk (Post)
Hello. I have a question for you, perhaps you have an answer to it. Regarding calling the Context menu from the keyboard in Devices, specifically calling the context menu window from the keyboard via an assigned combination. Goal: to have the ability to navigationally add internal Objects (Methods, Properties) to Function Blocks from the keyboard without using the mouse. The Codesys environment interface does not allow Windows access to this via Shift+F10. Externally (outside the Codesys environment), the hotkey call for the context menu (Shift+F10) from the keyboard works in various environments, but at the same time, in Codesys it does not (it doesn't work). I have already tried various options on my own to achieve this (but unsuccessfully): Tools\Customize\Keyboard\Objects (the set combination does not give the desired result) Tools\Customize\Keyboard\Objects... (the set combination is extremely useful as it provides access to adding objects directly to Devices but does not provide the ability to add an internal object (Method/Property) to a Function Block). Thank you in advance for your help!!! P.S. I have already started trying to implement a script-based solution to call the context menu via AutoHotkey - by relocating the mouse cursor to the area of the navigational selection with a subsequent call of the context menu on it and relocating the mouse cursor back to its initial position. And in order not to "reinvent the wheel," I am writing this request to you!!!
Last updated: 2025-10-05

Post by e13740e on Сalling the context menu from the keyboard CODESYS Forge talk (Post)
Hello. I have a question for you, perhaps you have an answer to it. Regarding calling the Context menu from the keyboard in Devices, specifically calling the context menu window from the keyboard via an assigned combination. Goal: to have the ability to navigationally add internal Objects (Methods, Properties) to Function Blocks from the keyboard without using the mouse. The Codesys environment interface does not allow Windows access to this via Shift+F10. Externally (outside the Codesys environment), the hotkey call for the context menu (Shift+F10) from the keyboard works in various environments, but at the same time, in Codesys it does not (it doesn't work). I have already tried various options on my own to achieve this (but unsuccessfully): Tools\Customize\Keyboard\Objects (the set combination does not give the desired result) Tools\Customize\Keyboard\Objects... (the set combination is extremely useful as it provides access to adding objects directly to Devices but does not provide the ability to add an internal object (Method/Property) to a Function Block). Thank you in advance for your help!!! P.S. I have already started trying to implement a script-based solution to call the context menu via AutoHotkey - by relocating the mouse cursor to the area of the navigational selection with a subsequent call of the context menu on it and relocating the mouse cursor back to its initial position. And in order not to "reinvent the wheel," I am writing this request to you!!!
Last updated: 2025-10-05

Post by snhatton on How to write a for loop in ladder? CODESYS Forge talk (Post)
Hi there, little late to the party, but you could also use the ST block for in-line ST code and implement a for loop as you normally would. ST Block is super handy if you just need a small amount of in-line structured text code without creating a new POU. Hope this helps!
Last updated: 2025-10-06

Post by rene2 on How can you get the active frame index from a frame CODESYS Forge talk (Post)
I think I struggle with the same issue. I tried the currentVisu variable but this is the active Visualisation. I have a dialog with a frame with frame configuration like in the picture. I would like to use the index te be used to make a button look like it's pressed/selected.
Last updated: 2025-10-14

Post by open on How to create a stopwatch? CODESYS Forge talk (Post)
Hi @ph0010421 and @Ton, Is it possible to program a stopwatch to measure a system running time when it is turn on, and pause when the system is turn off. I tried your examples when stopped, the elapsed time will then be calculated, but i need the time to be continuously counting. Warmest regards,
Last updated: 2023-12-11

Post by snhatton on OPC UA: How to change NodeId ?! CODESYS Forge talk (Post)
You can change the node id by adding the following to /etc/CODESYSControl.cfg: [CmpOPCUAProviderIecVarAccess] CustomNodeName=MyPLC123 Then restart the runtime and the new Node name will appear with the connection. I don't know if it's possible to remove the |var| from the name. I hope this helps!
Last updated: 2023-12-11

Post by nz-dave on Bool turning on in case stament in wrong state? CODESYS Forge talk (Post)
pretty sure its not. ive done a cross reference and only have one write that sets it to true. Only way i can stop it is to remove the function block call from the main pou that is running said case. its got me stumped:/
Last updated: 2023-12-16

Post by reinier-geers on SM3 motion project CODESYS Forge talk (Post)
Hi, i try to setup a softmotion programm. Controller version 15. Ethercat, When is scan Devices then it install's the drives. 4.11 . Somehowe they have a vesion 16 libary. I tried to install new but stil problems. I tried version 19. Then i get a Visu version problem. What can i do ? Why are ther always problems with a new version ?
Last updated: 2023-12-18

Post by ph0010421 on TCP/IP client CODESYS Forge talk (Post)
Hello TCIS_Send needs to be longer than 4 bytes because idata is 28 bytes long. There may be other ways, but I would make a UNION with string/array of bytes. Write your STRING into the AsString part then copy the AsBytes part into TCIS_Send (Elements [3] to [30]) then 252 would be in [31] (I've assumed the idata is always the same length)
Last updated: 2023-12-19

Post by user0815 on Web Socket Client SL -Bibliothek Fehler CODESYS Forge talk (Post)
Es sind keine exceptions im Log. Ein warning (no runtime license - running in demo mode(~2 hours) und der eine Fehler. Also bevor ich probiere was zusenden. Nach dem senden kommen zwei Ausnahmen dazu. Das Bild mit den Ausnahmen packe ich mal oben zu den anderen
Last updated: 2023-12-19

Post by ulad on SPI Communication CODESYS Forge talk (Post)
Hello. I created a project that uses SPI. This project is working well. I can see with an oscilloscope that the SPI pins are actually changing. But when I resave this project in the IDE and open it later in the system, I see a constant error. What do I need to fix? What am I doing wrong? Thank you.
Last updated: 2023-12-23

Post by svn123 on In Simulation Mode, logic is not executing CODESYS Forge talk (Post)
I stopped the simulation and tried to rebuild. "Cloned Task0.task0. Priority already in use" error was shown after rebuilding. I used Build-Clean All option and rebuilt again. Now the logic started working. But I am not still sure what caused the error in first place. If somebody knows about this error, please enlighten me. Thanks svn
Last updated: 2023-12-25

Post by dhumphries on Execution Order of Function Blocks CODESYS Forge talk (Post)
Function blocks in a SFC are executed left to right, top to bottom, instructions in ST are executed from left to right top to bottom as well. I think you are asking about the execution of POUs although you use the name function block, I believe POUs are executed in the order they are shown under the main task.
Last updated: 2023-12-28

Post by dhumphries on IO link on IFM AL133x only single digital input on a channel CODESYS Forge talk (Post)
Try changing the port mode to digital input for each port you want to have 2 inputs in the connection settings for the device. I've successfully used ports for inputs on an AL1920 this way, I think the procedure should be the same for an AL1332.
Last updated: 2023-12-30

Post by martinlithlith on Raspberry Pi: List of available drivers / libraries CODESYS Forge talk (Post)
Hi! I'm still on the hunt for drivers for example TCA9548 and a list or somewhere where all devices for raspberry is gathered. as this post is quite old I'm hoping/gussing that there is somewhere where work after 2021 is gathered? Or has the raspberry part if the community slowed down on creating device drivers?
Last updated: 2023-12-31

Post by patrick on Version 3.5.19.40 probleme bei FUN mit _to_ im Name CODESYS Forge talk (Post)
Ich bin leider auch über den Fehler gestolpert, aber selbst in Version 3.5.19.50 ist dieser noch enthalten. Bis 3.5.19.20 kann ich meine Programme noch nutzen. Ab 3.5.19.30 ist der Fehler anscheinend vorhanden. Ich habe leider auch schon einen Haufen Programme mit meiner Library erstellt, somit wäre ein umbenennen nur mit sehr viel aufwand möglich.
Last updated: 2024-01-02

Post by peter-skokanek on Rpi install runtime licence on SP13 CODESYS Forge talk (Post)
Hi, I have an older project which has been running for years. Unfortunately I have to replace current Raspberry. I repplaced it by new rpi 3 with newest 32 bit Raspberry OS. I oredered a new runtime licence. When I try to activate it, the connection to target is interrupted immediatelly after press next button in the last step of instalation.
Last updated: 2024-01-08