Search talk: data and time

 
<< < 1 .. 85 86 87 88 89 .. 186 > >> (Page 87 of 186)

Post by mondinmr on Patched Wine packages for Ubuntu and CODESYS 3.5 CODESYS Forge talk (Post)
I have now published Ubuntu amd64 packages of my patched Wine build for CODESYS, targeting Ubuntu 22.04, 24.04, 26.04 and 26.10. The packages are based on Wine 11.20 and include all five compatibility patches covering NCrypt, thread suspension, security tokens, service tokens and local WMI marshalling. Both 32-bit and 64-bit Windows applications are supported through WoW64. In my working environment, CODESYS 3.5 SP21 successfully compiled and went online with a very complex project containing hundreds of thousands of lines of code and extensive use of polymorphism. PPA and installation All four binary builds have completed successfully and are now published and available through APT. Wine ADV for CODESYS PPA sudo add-apt-repository ppa:mondinmr/wine-adv sudo apt update sudo apt install wine-adv The runtime installs under /opt/wine-adv and provides dedicated commands, allowing it to coexist with your existing Wine installation. For example, to launch CODESYS from an existing dedicated prefix: WINEPREFIX="$HOME/.wine.codesys" wine-adv \ 'C:\Program Files\CODESYS 3.5.21.30\CODESYS\Common\CODESYS.exe' Adjust the executable path to match your installed version. Use the same WINEPREFIX when running the CODESYS installer or installing its prerequisites. The package contains the patched Wine runtime. CODESYS and its required Microsoft .NET components must be installed separately inside the prefix. Source code, patches and packaging are available on the project page. This is an experimental community build. Feedback and test results from other users are welcome! CODESYS Installer and CodeMeter licensing are also working in my setup. For CodeMeter, I use the native Linux CodeMeter runtime, while the Windows applications run under the patched Wine build.
Last updated: 2026-10-31

Post by toby on Ethercat Servo Setup CODESYS Forge talk (Post)
Hi Everyone, I have a simple project with a single servo, but its my first time using Codesys and motion, so I'm a little confused and lost, I've tried to read the tutorial online, but I'm not having much luck sorry. Can I please ask for some pointers. I have a ComfilePi HMI (Raspberry Pi) communicating to a Omron R88D-1SN08H-ECT amplifier. Please see the attached project file (which is better for sharing, the project file, or a archive?). This file was simply for testing the motion of the servo before anything else is tested with it. The project simply rotates the servo 1 rotation when called for, but the speed can vary based on user input. Nothing much fancy. As yet, I haven't had any servo movement, no errors on the amplifier display. How do I link the motion FBs to the physical drive? Thank you very much for any help you can offer. I'm sorry if I'm doing something very stupid or basic and getting it wrong. Have a good day. Toby
Last updated: 2023-09-20

Post by oi18ct on ARM SL Development Board Recommendation CODESYS Forge talk (Post)
Hello codesys forum, My company is looking at developing a solution with Codesys ARM SL. The requirements will not tax the capabilities of Codesys. I would like to buy an AMR 7 or 8 Dev Board for experimenting. I am looking for a recommendation as I have minimal experience with Linux. Any input from the forum would be most appreciated as the hardware requirements as provided by Codesys for ARM SL seem pretty minimal (basically a arm7 or 8 with Debian is all). Our needs are small in scale- something like 8 digital inputs, 6 digital outputs, 2 analog inputs and 1 analog output. A small gui will be published via web visualization for external display (no local display). Communications with ModbusTCP and uart/RS485. It may be necessary to access i2c and make c or python calls to some existing code that is pretty small. Something like the EMCraft STM32MP1 SOM Starter Kit or Octavo Systems OSD32MP1-RED development board? Ideally something that has a path to a SoM for production. Kontron appears to have some interesting options too. Just having a hard time deciding where to start. Thanks in advance... LC
Last updated: 2023-11-11

Post by mikek10 on Ethernet/IP 4.6.0 causing exceptions? CODESYS Forge talk (Post)
Hi, I have a project currently in development, it has a number of Ethernet/IP devices (18 adapter devices with Codesys as scanner, another scanner device with codesys as adapter). This has been stable whilst on factory floor for several months (though prior to that I did have some Ethernet/IP issues which were resolved by adjusting RPI rates). Today I tried updating to Ethernet /IP 4.6.0 from 4.5.1, subsequent to this I had 2 exceptions in a 2 hour period, I reverted to 4.5.1 and have had no further exceptions. Note I do have a device (Zebra printer) that frequently times out and reconnects, this does not seem to cause any issues in operation and does not cause any exceptions with 4.5.1. I believe the root cause of this is on the Zebra side, however there does not seem to be any adjustment I can make to prevent the time outs. Information from device log is in screenshot attached.
Last updated: 2024-06-27

Post by karel-bas on Loosing connection to emulation running on Linux CODESYS Forge talk (Post)
Hello, I am trying to emulate my code but for some reason my Codesys IDE keeps loosing connection to the emulator. I am constantly pinging virtual machine on which its running and its running fine, but codesys refuses to reconect to it, and is not able to rediscover it. Codesys 3.5 SP20 Patch 1 I have linux installed like image in attachment.(using version 4.12) Linux VM is set up to use up to 4 cores and 8gb of ram, with nothing else runing on it. I dont have a license so I am aware that the emulation shouldnt run for more then 120 minutes I am able to, login, get sysinfo, reboot etc from codesys IDE for certain period of time (5minutes) then my connection gets lost, sometimes I can login again, but sometimes i have to reboot the VM. Any suggestions what might be the issue ?
Last updated: 2024-09-19

Post by kurtk on dynamic modbus devices CODESYS Forge talk (Post)
I am CODESYS neophyte getting my wheels on. My goal is to re-platform an existing PLC application written in 61131 ST I've got the majority of the code/variables in a compilable form - excluding all the IO and comms nuances I am not sure whether this the right forum An important functionality which I implemented on the other platform was totally dynamic modbus devices... Most configurations I have come across impose static MB configs in which all configured devices MUST be present and functional... I have monkeyed around with MB enough to know that herding a half dozen MB cats into a working config can be tricky. I just do them one at a time and dynamically turn them on/off in whatever combination is convenient with ID, IP, baud, parity etc being runtime tweakable. I am totally curious whether this is possible with codesys, or whether its device configuration corrals one into a static cage which requires re-building the code to support flexible variations. Best regards
Last updated: 2025-08-19

Post by kurtk on runtime dynamic modbus devices CODESYS Forge talk (Post)
I am CODESYS neophyte getting my wheels on. My goal is to re-platform an existing PLC application written in 61131 ST I've got the majority of the code/variables in a compilable form - excluding all the IO and comms nuances I am not sure whether this the right forum An important functionality which I implemented on the other platform was totally dynamic modbus devices... Most configurations I have come across impose static MB configs in which all configured devices MUST be present and functional... I have monkeyed around with MB enough to know that herding a half dozen MB cats into a working config can be tricky. I just do them one at a time and dynamically turn them on/off in whatever combination is convenient with ID, IP, baud, parity etc being runtime tweakable. I am totally curious whether this is possible with codesys, or whether its device configuration corrals one into a static cage which requires re-building the code to support flexible variations. Best regards
Last updated: 2025-08-19

Post by mrkm-dic on CODESYS: Combining Master Redundancy with EtherCAT Ring Topology – Is it Supported? CODESYS Forge talk (Post)
Hello, I would like to ask whether it is technically supported (and practically achievable) to combine CODESYS Master Redundancy with EtherCAT ring (loop) redundancy in the same system. System setup CODESYS version: CODESYS 3.5.21.40 CODESYS Control SL for Weidmuller u-OS-4.12.2.0 Controllers (Masters): Weidmuller UC20-M4000 ×2, configured as Active / Standby using CODESYS redundancy EtherCAT Slaves: Weidmuller UR20-FBC-EC ×3, supporting EtherCAT ring / line break detection Topology: EtherCAT ring (loop) Main question Is it officially supported to use: ・CODESYS PLC/Master redundancy (Active/Standby) and ・EtherCAT ring topology (for cable redundancy) at the same time? Expected behavior Our expectation is: ・When the Active PLC fails, the Standby PLC becomes Active ・The Standby PLC then takes over the role of EtherCAT Master ・EtherCAT communication is re-established ・I/O control continues after reinitialization (a short interruption is acceptable; no strict bumpless requirement) We do not expect completely seamless / zero-cycle switchover, but we want to understand: ・Whether this combination is supported by design ・Or whether there are known limitations or restrictions when EtherCAT ring mode is used together with Master redundancy Clarification At this stage, the question is mainly about feasibility and support, not about a specific error message yet. Any official guidance, limitations, or real-world experience would be greatly appreciated. Thank you in advance.
Last updated: 2026-02-05

Post by damian177 on Codesys and SMS in RPi CODESYS Forge talk (Post)
Hi, I try use IIoT library to send and receive SMS by Raspbery PI and Codesys. I installed IIoT package and added the SMS library, But something is wrong, when I init communication it doesn't work, When I sniffer my communication (AT commands) beetwen RS232 RaspberryPi and my GSM modem I have only below commands: AT+CMEE=1 OK AT+CPIN? +CPIN: READY Anyone have idea what can be wrong ?
Last updated: 2023-09-28

Post by tehthoams on Find Function: Object reference not set to an instance of an object. CODESYS Forge talk (Post)
Hey, Sorry this isn't super helpful, but i had this problem once and was able to resolve it. I can't recall how I solved it and whether it was a problem with my codesys installation or the project itself. If it is the codesys installation, make sure all your required libraries and plugins are installed and available. compare with a colleagues installation if possible. I vaguely recall saving a copy of my project and deleting things one by one until the error went away...
Last updated: 2023-10-30

Post by tehthoams on Find Function: Object reference not set to an instance of an object. CODESYS Forge talk (Post)
Hey, Sorry this isn't super helpful, but i had this problem once and was able to resolve it. I can't recall how I solved it and whether it was a problem with my codesys installation or the project itself. If it is the codesys installation, make sure all your required libraries and plugins are installed and available. compare with a colleagues installation if possible. I vaguely recall saving a copy of my project and deleting things one by one until the error went away...
Last updated: 2023-10-30

Post by wayne-riesterer on Assignment Efficiency - Repetitive Assignment vs IF statement CODESYS Forge talk (Post)
Hello Can anyone see any problems with constant assignment as in the following statement: Coils[0] := Coils[0] OR (Buttons[0] AND Sensors[0] > 6); Rather than using the more verbose and vertically-larger: IF NOT Coils[0] AND Buttons[0] AND (Sensors[0] > 6) THEN Coils[0] := TRUE; END_IF Also, is the test expression short-circuited in the latter case? In other words, will the runtime move on after it sees Coils[0] = FALSE AND? Thanks
Last updated: 2025-03-07

Post by otdeveloper on IEC 61499 CODESYS Forge talk (Post)
It is being worked on by many companies and its even-driven function blocks seem like a natural evolution of the object oriented industrial programming I have seen Gary Pratt (author of the Book of CODESYS and much more) so expertly implement and explain. I would expect CODESYS to have this front and center on their sights and, if they do not, I would be very interested in learning why.
Last updated: 2024-02-09

Post by pbitalc on Customize Users and groups Visualization in UserMgmtConfig CODESYS Forge talk (Post)
Hi, I have the user situation represented in the image and I would like CustomerAdmin to only be able to modify/add/delete users relating to the CustomerUser group and nothing else. How can I do? It would be enough not to display the users belonging to the SuperAdmin, Technician1 and Technician2 groups and also the related groups in the UserMgmtConfig dialog box. Can anyone help me? I use Codesys 3.5.16 Thanks!
Last updated: 2024-02-29

Post by sachem on SysFileGetTime problem CODESYS Forge talk (Post)
Good morning. I'm working with a Weidmuller controller using Codesys. My project use OPC-UA to communicate an application in my pc with the controller. Yesterday, I installed the license of the controller and test it, and the communication works perfect. I use the communication with anonymous login, and works fine. But, hours later, the anonymous login don't work, and the controller only allows connection via OPC with username and password. Someone know why this happend? Thanks
Last updated: 2024-04-09

Post by valenting on Problem with Licenced Software Metrics CODESYS Forge talk (Post)
Hi, I tried with another project, using codesys SP20 with the latest visualization installed, I can install the application on my device but it doesn't work I get an exception "invalid license metrics" and the app won't run See attached the metrics in project and allowed by license, and the logs What am I supposed to do ? Everything is in the newest version and the values are lower than allowed and nothing works...
Last updated: 2024-04-26

Post by srinidhi on Pilz PBRT Robot with CoDeSys CODESYS Forge talk (Post)
If anyone here are working with robots and using Codesys to control it and implement tasks, Please let me know. I am currently in my Master thesis and i need some advice on this. We have Pilz Robot with Codesys and I am trying to proceed with certain tasks but have no documentation for it. Would be helpful if anyone of you can suggest and help connect with the right people.
Last updated: 2026-05-10

<< < 1 .. 85 86 87 88 89 .. 186 > >> (Page 87 of 186)

Showing results of 4636

Sort by relevance or date