Post by sturmghost on Visualization using methods and cyclic ST-calls CODESYS Forge talk (Post)
Im looking for a way to implement ST-code into the visualization element without creating a helper POU or method in my device/application tree. Like visualization properties are evaluated at each VISU_TASK cycle I want to be able to create own ST code which interacts with the visualization interface variables. To be more specific I want to have a property which executes user defined ST-code at each VISU_TASK cycle exactly like its already possible for Input Configuration on various mouse and dialog events. Also a property for initialization (so only executed once) and a timed property would be nice. With the situation right now I'll have to create a POU function which handles the ST-code and misuse a property, like the text variable, to execute this POU function at each VISU_TASK cycle. Or does it exist and I don't know it?
Last updated: 2023-10-02

Post by ryusoup on JSONByteArrayWriter problem? CODESYS Forge talk (Post)
Hello, I am trying to implement a FB to make JSON formatted WSTRING type message using JSON Utilities 1.9.0.0 included in the IIoT library. In my case, I want to set some objects or arrays and set values to them later. But when I wrote as the sample below, // init builder builder(pJsonData:=pJsonData, diRootObj=>diRootObj); // set the 1st key to root diKey1 := builder.SetKeyWithArray(wsKey:="key1", diParentIndex:=diRootObj, eError=>eError); // set a value to the 1st key wsValue:="value01"; builder.SetValue(Value:=wsValue, diParentIndex:=diKey1, eError=>eError); // set the 2nd key to root diKey2 := builder.SetKeyWithArray(wsKey:="key2", diParentIndex:=diRootObj, eError=>eError); // set a value to the 2nd key wsValue:="value02"; builder.SetValue(Value:=wsValue, diParentIndex:=diKey2, eError=>eError); // set a value to the 1st key again wsValue:="value03"; builder.SetValue(Value:=wsValue, diParentIndex:=diKey1, eError=>eError); // set a value to the 2nd key again wsValue:="value04"; builder.SetValue(Value:=wsValue, diParentIndex:=diKey2, eError=>eError); // write build result writer(xExecute:=TRUE, pwData:=ADR(wsResult), udiSize:=SIZEOF(wsResult), xAsyncMode:=FALSE, jsonData:=pJsonData^); the result was: { "key1": ["value01"], "key2": ["value02", "value03", "value04"] } while my expection was: { "key1": ["value01", "value03"], "key2": ["value02", "value04"] } Inspecting pJsonData^, JSONData itself seems to be ok, so I believe the issue is something caused by the writer FB. Does anyone know how to fix it? Thanks,
Last updated: 2023-10-04

Post by captaincookie on increase default string length in queue CODESYS Forge talk (Post)
Hello, I'm using Codesys V3.5 SP18 Patch 4. In the ElementCollectionExample Project from Codesys, I test the SimpleQueueExample in a Control Win V3 x64 environment. I try to add a string of 95 characters length to a queue. The default length of strings is defined as 80 characters. In the initialization of a string variable, it is possible to increase the length by the definition of e.g. STRING(1000). But when I write the string defined like this to the queue, only 80 characters are written to it and the rest is missing. I think the default length is still set in the queue definition, so it is necessary to change this, isn't it? Is there any option to increase the default length of strings in the queue? Attached you can find the used project. Thanks in advance. If any information are missing or my description unclear please let me know.
Last updated: 2023-10-05

Post by toffeebonbon on EL7041-0052 - does it run with EL7041 SoftMotion? CODESYS Forge talk (Post)
Good morning everyone. In my setup I am trying to use a couple of EL7041-0052 (the EL7041 variant without terminals for an encoder) to run stepper motors without feedback. When using the softmotion drivers for the EL7041 (Rev22 and Rev24, even selecting external feedback type doesn't work) the device log shows warnings for the corresponding hardware: "SDO write error 0x1 -> 0x8012:0x08 eError 0x1 AbortCode 0x6090011". 0x8012:0x08 is the register for the Feedback Type. My best guess was setting the the register value in the start parameters to zero, but the result is the same. What else can I try to get the hardware to work? I have screenshots attatched showing the running fieldbus and the log messages. EDIT: One clarification: the "device log" that shows the error is the PLC, not the ethercat terminal. The log of the terminal itself shows neither errors nor warnings. BR Robert
Last updated: 2023-11-29

Post by grant32 on RAMP_REAL FB is retaining my output value when i try to re use the FB CODESYS Forge talk (Post)
Hello, I'm relatively new to PLC programming. I am trying to creat a ramp down function, I have an example here of what I am using. I can get the function to work, the issue is that the OUT (variable3) value is being held by the FB so after I use it once it no longer works. In this example i set variable3 to 100 and the rest is as seen, over the course of a minute it ramped down to 10 (as desired). But when I deenergize TEST_START, set variable3 back to 100, and then re-energize TEST_START it immediately jumps back to the previously held value 10. The reset on this block just pauses the function and holds the last OUT. In my case I will need the function to start OUT at a set value, ramp down to the IN (variable2) value, and then accept a new OUT value to ramp down next time the block is energized. Hopefully this made sense, if anyone has any advice that would be awesome!
Last updated: 2024-07-29

Post by programmierer on Implementing UDP Communication CODESYS Forge talk (Post)
Hello everyone, I hope you can help me with my problem. I am new to programming and am currently working with a WAGO controller in our lab, which controls a heat pump. My goal is to send the electrical power of the heat pump (Pel_WP) via a UDP connection to a specific IP address. I am using Codesys version 2.3 and following the guide I found here: https://forge.codesys.com/forum/de/396/genmed-Konfiguration%20der%20UDP%20Kommunikation%20Cosesys%20S7.pdf. I have adapted the guide to suit my needs. The data sending works since I can force the reception value Pel_WP and the data is sent accordingly. However, I am having trouble with the receiving part. The reception value is not being correctly received, and the diSocket variable shows -1. The connection between the heat pump and the WAGO controller seems to be set up correctly, as the heat pump is listed under the communication parameters with the correct IP address. I have also attached images to provide a better view of the setup. I would greatly appreciate any support or suggestions for a solution. Thank you in advance!
Last updated: 2024-08-02

Post by paulorb on STRUCT AT %MW1000 CODESYS Forge talk (Post)
Hi I am trying to use STRUCT to parse commands from Modbus/TCP, Modbus client will fill the bytes related to a specific command (type, parameters), then PLC (Codesys) will access the command parameters. A STRUCT will simplify a lot the process of parsing the data, so I don't need to parse byte per byte, address will be mapped to a struct and I can use it for parsing the data. From what I understood, the compiler does not allow me to specify the location of the struct for a %MW register. VAR_COMMAND AT %MW1002: structGenericModbusCommand; This will throw: Bad declaration, use '%ML' for 'structGenericModbusCommand' variable But If I change it to %ML, when you go online you see that it is actually allocating the struct in another memory address. When we go online, on GVL we can see: VAR_COMMAND. structGenericModbusCommand %ML1002 commandType COMMANDTYPE %MB8016 ... %MB8020 I am not specifying a pointer or a reference it is a struct type, why is it mapping to a %MW location (random one). How can I control where it is mapping to? I need a consistent way to map STRUCT to specific modbus address. Is it possible? Thanks, Paulo Note I am using a Codesys OEM: Schneider Machine Expert Logic Builder (M241)
Last updated: 2024-08-13

Post by dogulas on OPC UA C# client connecting to OPC UA CODESYS server CODESYS Forge talk (Post)
Noob alert! I’m just getting my feet wet with CODESYS. I have a “Hello World” project in the CODESYS IDE. I’m using the Win SoftPLC on the same computer. I’ve added a Communication Manager under the Application node. Under that is “OPC UA Server -> IEC Symbol Publishing 01”. I also added “OPC_UA_Symbols -> Information Model”. I’m not sure I need the second thing. I was grasping at straws. I also set up several dummy symbols in the IEC Symbol Publishing 01 node. In my C# application, I am trying to get an instance of EndpointDescription from CoreClientUtils.SelectEndpoint(“opc.tcp://localhost:1217/Gateway-1”, useSecurity: false, 15000). I wasn’t sure about the “Gateway-1”. I found that in the CODESYS IDE under the project -> Communication Settings. When I execute the previous method call in C#, I get: “BadSecureChannelClosed”. I have no idea what that means. Any pointers to documentation are welcome.
Last updated: 2024-08-16

Post by ruobian on Analog Input Delay Timer CODESYS Forge talk (Post)
Hello there, I am new here and in programming. I need help with the basics. I am trying to do what I mentioned in the title. I have an analog input. So I have a real or integer data type value. I want to delay it. TON and TOF only work with bool. I think there is a function block that has two inputs, 1 for real or int and 1 for bool. And if bool is true, it will give the output as real or int. I don't know but I need something like this. Actually, it is not exactly like that. In other words, it will not show the real value at the input at the output after a certain period of time. I want it to show the real value from 2 seconds ago continuously. The purpose of doing this is to compare the real value I received with the value from 2 seconds ago and find out whether it went up or down. I am using only FBD. Please help me with this. Thanks in advance.
Last updated: 2024-08-20

Post by mondinmr on First IO address of a CAADiagDeviceDefault. CODESYS Forge talk (Post)
I have a device CAADiagDeviceDefault: IoConfig_Globals.Axis_A In our library, we perform introspection of the Etc_SlaveDiag. In that case, we have connectors, and by searching for them by address, I can find them in the IO mapping using the offset and size provided by EtherCAT. However, a Lenze i700 drive, instead of placing the IO mapping in the Etc_SlaveDiag device, places it in a sub-device CAADiagDeviceDefault. So, when I perform introspection, I cannot find the IO correspondences. Yet, in the CAADiagDeviceDefault, I do not find the connectors and cannot do the matching. Is there a way with a pointer or reference to a CAADiagDeviceDefault to obtain the address of the first input and the address of the first output? This is because we have our own motion library with many EtherCAT devices that automatically configure the mappings, but I can't manage to do so with the Lenze i700.
Last updated: 2024-08-22

Post by karel-bas on Loosing connection to emulation running on Linux CODESYS Forge talk (Post)
Hello, I am trying to emulate my code but for some reason my Codesys IDE keeps loosing connection to the emulator. I am constantly pinging virtual machine on which its running and its running fine, but codesys refuses to reconect to it, and is not able to rediscover it. Codesys 3.5 SP20 Patch 1 I have linux installed like image in attachment.(using version 4.12) Linux VM is set up to use up to 4 cores and 8gb of ram, with nothing else runing on it. I dont have a license so I am aware that the emulation shouldnt run for more then 120 minutes I am able to, login, get sysinfo, reboot etc from codesys IDE for certain period of time (5minutes) then my connection gets lost, sometimes I can login again, but sometimes i have to reboot the VM. Any suggestions what might be the issue ?
Last updated: 2024-09-19

Post by lbartik on J1939 TX/RX PDU1 CODESYS Forge talk (Post)
Is it possible to transmit a PDU1 PGN using the J1939 manager and local device? What if I need to transmit a PGN RQST via 0xEA00 (PGN 59904)? How would I do this P2P (Destination < 0xFF) or broadcast (Destination 0xFF)? I don't think this is possible for any destination type. I don't think it's possible to receive broadcast PDU1 messages either. For example, an address claim PGN 60928 (0x18EEFF80) is addressed to all nodes (0xFF) and not any specific local device so it will be filtered out. These are major oversights in the IoDrvJ1939 library to not support every PDU1 RX/TX scenario. IoDrvJ1939 supported scenario: 1. Receive (RX) PDU1 (P2P) destination-specific (PDU-specific < 255) to local device with matching address IoDrvJ1939 unsupported scenarios: 1. Receive (RX) PDU1 (P2P) global (PDU-specific = 255) 2. Transmit (TX) PDU1 (P2P) global (PDU-specific = 255) 3. Transmit (TX) PDU1 (P2P) destination-specific (PDU-specific < 255)
Last updated: 2024-09-23

Post by codesysbeginner on Eaton XC303 - USB Mounting / Trend manager CODESYS Forge talk (Post)
Hi, For a project I am using the trendmanager functionality, I changed the placeholder filepath to which the SQL database is saved to: home/disk_usb, $trend$. Which only works as long as the usb was mounted to the PLC at boot. However, I'd like to be able to switch the USB's out if they break or for data analysis. However when a new (or the same) USB is plugged back in the shortcut doens't exist on the device anymore. Also in the device directory under root/mnt/ a new folder appears SDB1 in addition to SDA1 to which the Trendmanager was originally writing. The SDA1 folder is empty/unreachable while the new SDB1 folder has the contents of the USB drive. I tried disabling the trendmanger while unplugging the USB's however this doesn't work. My question, how do I make it so that when I plug a USB drive back in, it will be mounted to SDA1 instead of SDB1? Kind Regards
Last updated: 2024-10-09

Post by z870623 on About CPU Loading CODESYS Forge talk (Post)
I am running a runtime environment on an ARM A35 dual-core processor (1.5GHz) and have encountered some issues. The CPU load (both CPU0 and CPU1) occasionally spikes above 50% before returning to normal, and this happens around 2-3 times per minute. At the same time, I’ve noticed that the Max Cycle Time in the Codesys monitoring screen shows much worse performance compared to the A53 (1.2GHz), with nearly double the cycle time. The optimizations I have made so far are as follows: Set the CPU to performance mode. Isolated CPUs: CPU0 is dedicated to running Linux services and the runtime itself, while CPU1 runs the EtherCAT task and the MainTask. Despite CPU1 only running these two tasks, the utilization still increases above 50%, which I find unreasonable. Additionally, I performed tests using cyclictest both without and with the runtime running. The performance is shown in the following image: From the results, I believe the CPU performance should be fine, but I am unsure why the monitoring results are not as expected. The testing outcomes should ideally be as close as possible to the cyclictest results. Does anyone have related solutions to this issue?
Last updated: 2024-10-14

Post by etienneneu on loading delay with the option "check client animations and overlay of native elements" CODESYS Forge talk (Post)
Hey NicolaG_89, thanks for the tip. But I have seen in the developer tools of the Webclient that a multiple fetching of the image and script data occurs when changing frames (HTTP code 304 NOT Modified), although these are already in the clients cache, which leads to unnecessary loading of resources from the web server. This behavior can also be found if the option “Support client animations and overlay of native elements” is deactivated, but this does not lead to such long delays. I had already tested loading all Visu elements so that everything was fetched once before they could be used. But that didn't help either. To prevent this behavior (permanent fetching), I have used a different way of switching the Visu elements in the VisuDemo Project, which also uses HTML5 control elements. I implemented this with the visibility of entire Visu elements. As a result, it only has to be fetched once and does not have to be fetched again when reloading. But I am still unsure about this implementation if the scope of the visualization becomes larger, as the Codesys visualization documentation advises against using many invisible elements. Best regards Etienne
Last updated: 2024-11-19

Post by bertcom on STRING conversions to DWORD CODESYS Forge talk (Post)
Good afternoon. I want to communicate with a Domino Industrial Printer using its Codenet protocol. The printer wants a series of Hexadecimal characters with no spaces or '00' characters. Because of that i chose the option to make the prefix and subfix for my code in a string. I have variable data in another string. With a complete program of a lot of CONCAT functions i eventually get the format of code that the printer accepts ( tested it with the hercules tool). Hercules String : 1B4F513030311B7532626C61636B04 The problem is : Codesys adds automatically 'code' to the code to show it is a string. Codesys string : '1B4F513030311B7532626C61636B04' The printer does not understand this. My idea is to convert the string datatype to an LWORD. I have no idea how to do this. I random types in STRING_TO_DWORD, as return i get 0. That didn't worked. Also on internet the explenations around string converting in codesys are very limited. If there in anyone who can explain me how to do it, i would appreciate it a lot ! Thank you!
Last updated: 2025-01-29

Post by timvh on Device diagnosis ( EtherCAT IO card ) CODESYS Forge talk (Post)
You can get the state by just using the name of your node (same name as in device tree): VAR etcState: IoDrvEthercatDriverLib.ETC_SLAVE_STATE; END_VAR etcState := EJ1100.wState; Alternatively, you can iterate through the device tree to get the status of all (Ethercat) nodes. See here an example (no guarantee it works, just give as suggestion): PROGRAM P_IO_State VAR CONSTANT uiMAX_NR_OF_TERMINALS : UINT := 100; END_VAR VAR // general device diagnosis // can only be used when the Device - PLC Settings - Advanced settings - enable diagnosis for devices is enabled // this will add the DED library coupler: DED.INode; terminal: DED.INode; aDeviceState: ARRAY[0..uiMAX_NR_OF_TERMINALS - 1] OF DED.DEVICE_STATE; uiTerminalCount : UINT; uiIndex : UINT; // for each terminal check if it implements device diagnostics xQueryResult: BOOL; itfDevice : DED.IDevice2; xDiagAvailable: BOOL; eError: DED.ERROR; xEverythingOK: BOOL; END_VAR uiTerminalCount := 0; // start at the top of the device tree with the first EtherCAT coupler coupler := EtherCAT_Master.FirstChildNode; WHILE coupler <> 0 DO // for each coupler that is found start at the first terminal terminal := coupler.FirstChildNode; WHILE terminal <> 0 AND uiTerminalCount < uiMAX_NR_OF_TERMINALS - 1 DO // for each terminal that is found get the status through the device diagnosis interface xQueryResult := __QUERYINTERFACE(terminal, itfDevice); IF xQueryResult THEN aDeviceState[uiTerminalCount] := itfDevice.GetDeviceState(xDiagnosisInfoAvailable => xDiagAvailable, eError => eError); uiTerminalCount := uiTerminalCount + 1; END_IF terminal := terminal.NextSiblingNode; END_WHILE coupler := coupler.NextSiblingNode; END_WHILE uiIndex := 0; xEverythingOK := TRUE; WHILE uiIndex < uiTerminalCount DO IF aDeviceState[uiIndex] <> DED.DEVICE_STATE.RUNNING THEN xEverythingOK := FALSE; EXIT; END_IF uiIndex := uiIndex + 1; END_WHILE
Last updated: 2025-02-06

Post by ojz0r on Assignment Efficiency - Repetitive Assignment vs IF statement CODESYS Forge talk (Post)
Its important that you know the difference between the two. Example 1: Coils[0] := Coils[0] OR (Buttons[0] AND Sensors[0] > 6); In this case the statements will be evaluated every scan and result in either true or false for Coils[0]. Example 2: IF NOT Coils[0] AND Buttons[0] AND (Sensors[0] > 6) THEN Coils[0] := TRUE; END_IF In this example Coils[0] will latch the result in a true evaluation, if you want it to behave the same way as example 1 then you need to do it like example 3 below: IF NOT Coils[0] AND Buttons[0] AND (Sensors[0] > 6) THEN Coils[0] := TRUE; ELSE Coils[0] := FALSE; END_IF However back to the real question. There is no problem using either example 1 or example 3, if im not requiring a latch i usually go with example 1 as it is more compact.
Last updated: 2025-03-07

Post by pikebuster on Help for a newbie CODESYS Forge talk (Post)
Can somebody help me with this? I have problem with the button! This task must be solved using Sequential Function Chart (SFC), IEC 61131-3. TASK Create an SFC program to control a traffic light at an intersection. Description: You will program a traffic light that has three phases: Green, Yellow, and Red. The traffic light must follow these rules: Green light is on for 10 seconds. Yellow light is on for 3 seconds. Red light is on for 10 seconds. If the pedestrian button is pressed, the system must keep the red light on for 20 seconds during the next cycle. After the pedestrian has “crossed,” the system should return to its normal cycle. Basic Steps: Initialization: Start by setting the traffic light to Red. Green Phase: After 10 seconds, switch to Green. Yellow Phase: After 10 seconds in the Green phase, switch to Yellow. Red Phase: After 3 seconds in the Yellow phase, switch back to Red. Loop: Repeat the cycle. Use, for example, lamp symbols in the visualization module to simulate the traffic light. You may also add a simple pedestrian light if desired.
Last updated: 2025-03-11

Post by nz-dave on MC_HOMING CODESYS Forge talk (Post)
Hi Just new to motion and i am building my own 3axis cnc cutter using servo drives. i have every thing working quite well apart from mc_home. when executed (r_trig) it stops immediately and i get fb_wasnt_called_during_motion. if i execute the mc_home fb with a toggle it just runs and runs for a while then errors out. what im unsure of is the way mc_home works. from what i understand it changes the drive mode to 6 (homing) and should then run of the drive homing settings. once origin sensor is made then homing would stop and mc_home.done is true. and the position on the fb is where i what the new home position (zero) to be? or do i feed mc_readposition to that input? so i would think its the settings in the drive that aren't quite right. but i believe they are all correct. has any one got any info to steer me in the right direction? Cheers
Last updated: 2025-04-04

Post by jschu on Dynamical scaling of bar graph without the bar itself CODESYS Forge talk (Post)
Hi there, Task: dynamical changing the scaling of an bar graph, linear scaling whitout showing the bar only the scaling values and Lines for Main and partial steps. Define 4 Limits for Hi and LO Values with different colors Option 1 : use the bar graph whitout showing the actual bar whitout showing the bar, only the scaling values and lines for main and partial steps. Then what to do with the 4 Limits ? I could use 4 moveable Rectangles with the start and end value fo the areas but then the whoel bargraph must be transparent. Best way would be if only the scale ist possible to show as it is possible for the Meter 180° but this option does not exist for the bargraph. Option 2 : user defined HMTL5 Widgets wich may be some allreay has created or where is a dome for using this kind of html5 widget. The expanse for use html is in my eyes to big and gives more option for errors. Have some one experience in this topic or a hint how to do it the easiest way? Thanks for your help.
Last updated: 2025-05-15

Post by astutoski on No Motion with SM3_RaspiStepper (GPIO 23/24 Show No Pulses) CODESYS Forge talk (Post)
Hi everyone, I’m completely new to CODESYS and have been teaching myself. And i Want to control an Axis using SM3RaspiStepper. Following the example on the RaspiStepper home page, I set up an axis through a POU and tied the SMC_StartupDrive (Visu) template to my axis instance (sud). Unfortunately, the motor never moves and I don’t see any pulses on the PULSE pin (GPIO 23). Hardware -Raspberry Pi 4 B -Nema 17 stepper motor -A4988 stepper driver (EN pin permanently tied to GND) Software / Runtime -CODESYS 3.5 SP21 Patch 1 – Raspberry Pi runtime (demo) -SoftMotion in demo mode -Package: SM3_RaspiStepper 0.0.0.6 Axis parameters: Pulse pin GPIO 23 Direction pin GPIO 24 Enable pin 0 (unused) Disable pin 0 (unused) Whether I start the axis from the visualization template or through Online Config Mode, the motor never spins. In Online Config Mode I press Power → the state changes from Standstill to Discrete_Motion, but the motor shaft is still locked and no step pulses appear on GPIO 23 (checked with a scope). I can provide screenshots of the Visualization, PLC logs, or wiring pictures if that helps. Any ideas on what I might be missing? Happy to provide screenshots, project files, or scope captures if that helps. Thanks in advance!
Last updated: 2025-06-25

Post by westcountryewe on Displaying a Target Web Page on WebVisu CODESYS Forge talk (Post)
I have a main PLC with my CODESYS project on, including Web Visu. I also have a second device used for pump monitoring, all of this is displayed on a seperate HMI. I am looking at displaying the pump monitoring HMI on WebVisu so that I can solely use 1 HMI rather than having two. I can project the pump monitoring HMI into Chrome, and log in and it works fine. When I'm using the Web Browser element in Web Visu, enter my URL (device IP) it shows me the web page, but doesn't show me all of it. It uses parts of JavaScript for the login authenticiation and various other widgets. Similarly, I cannot get Youtube or Google to display on WebVisu either (possibily because of the same reason). Does anybody have any tips on how I can display the likes of Youtube or Google onto WebVisu so I can view it on my 7inch HMI (I suspect that if I can get Youtube or Google to work, then I will also be able to get my pump montitoring web page to work too).
Last updated: 2025-07-09

Post by jakubmphoenix on EtherCAT Master on RaspberryPi with EtherCAT Slave on Beckhoff CODESYS Forge talk (Post)
Hello everyone, I’m currently working on setting up an EtherCAT Master using CODESYS on a Raspberry Pi, and I’ve run into some issues I could use help with. Project Setup: EtherCAT Master: Raspberry Pi with CODESYS Control for Raspberry Pi 64 SL installed EtherCAT Slave: Beckhoff CX5130 with EK1200 coupler I/O Module: EL2008 License Module: EL6070-0033 I’ve installed the required CODESYS packages and the Linux gateway on the Raspberry Pi. In my project, I added the EtherCAT Master with the appropriate port settings and scanned for devices. The CX5130 shows up as a slave, but communication fails—I'm getting error messages and can't access the outputs. Specifically: The EL2008 output module isn’t recognized properly in CODESYS. There’s no option to communicate with it through the CX5130. I’ve tried connecting via both the Raspberry Pi’s built-in Ethernet port and an external network card. I've attached screenshots showing the errors I get in CODESYS and the devices detected via TwinCAT for reference. Any help or suggestions would be greatly appreciated! Thanks in advance! EMERGENCY FROM DEVICE 1001 ERROR CODE 16#A000 Error register 16#02 Error field: 16#02 Error field : 16#0E 16#04 16#00 16#04 16#00
Last updated: 2025-07-16

Post by pouyavakili on Execute Codesys Tests with python CODESYS Forge talk (Post)
❓ Issue: TestManager Not Available in Python Script (AttributeError) 🙏 Question: Why does project.get_testmanager() not work in scripting, even though Test Manager is installed and licensed, and the script runs in GUI mode? Is there a way to ensure the Test Manager interface is loaded or accessible from the scripting environment? 🧠 Summary: I'm trying to automate test execution using the CODESYS scripting engine (Python) via a script that opens a project, builds the application, and runs tests from a TestRepository.xml. Although the Test Manager works manually in the IDE, it fails when accessed via script with the following error: AttributeError: 'ScriptObject' object has no attribute 'testmanager' 🧪 Test Setup: CODESYS version: 3.5.21.10 Test Manager: Installed and licensed (works in the IDE manually) Project: Contains a test repository, which can be executed via the GUI Script execution method: powershell Start-Process -FilePath "C:\Program Files\CODESYS 3.5.21.10\CODESYS\Common\CODESYS.exe" ` -ArgumentList @( '--profile="CODESYS V3.5 SP21 Patch 1"', '--runscript="C:\Scripts\run_tests.py"' ) -Wait 📜 Script Summary: python project = projects.open(project_path) application = project.active_application application.build() This fails: testmanager = project.get_testmanager() ❗ Problem: Calling project.get_testmanager() or application.testmanager throws an AttributeError, even though the same project and test repository work in the GUI.
Last updated: 2025-07-23