Search talk: read file using

 
<< < 1 .. 87 88 89 90 91 .. 96 > >> (Page 89 of 96)

Post by rmaas on Fieldbus has lost synchronicity CODESYS Forge talk (Post)
Hi, On a gantry system with 2 axis i am getting the following error: SMC_DI_FIELDBUS_LOST_SYNCRONICITY This happens random, sometimes it happens every 5 minutes and sometimes no error for 2 hours... The Setup: - Using codesys 3.5 SP20 with all latest libs... - Kontron AL Pi-Tron CM4 with Preempt realtime patch (Raspberry Pi 4) - Codesys runtime 4.11.0.0 (single core) - CODESYS Control for Raspberry Pi SL licensed - Softmotion + CNC + Robotics licensed - 2x Leadshine EL8-EC400 servo drives - Axis group for a 2-axis T-Gantry Ethercat network wiring: Ethercat master softmotion -> Beckhoff EK1100 -> Servo drive #1 -> Servo drive #2 Ethercat Cycle time = 4ms Max Jitter = 140~150 What i have tried so far: - changed the sync offset from 20% to 30% - changed ethercat task priority from 1 to 0 Running tasks: - Ethercat tast: Prio = 0, Interval = 4ms - Main task: Prio = 1, Interval = 8ms - Visu task: Prio = 31, Interval = 100ms - Softmotion planning task: Prio = 15, Freewheeling - 3 other default tasks that were created by AC_Persist Motion fb's are called in the ethercat task... Does anyone have an idea how to fix this? Any help is greatly appreciated!
Last updated: 2024-04-11

Post by salvadegianluca on How to use TON inside an FB that is instanced within a Visu page CODESYS Forge talk (Post)
Hi everyone; I'm building a project in which the drag of the mouse over some controls (or the click event) changes the background color of the control items; this change of color is made with an FB that assignes a color code to the background with MUX command based on the value of an enumerator, this part is perfectly working but, when I'm using a touchpanel instead of a web visu (controlled by a mouse) I get into some issues as it seems that the touch operations are not triggering the MouseEnter and MouseLeave properties as it's done with the mouse.... For this reason I'm trying to add a TON to my FB and, if the enum that changes color remains at the same state for more then 3s I'm automatically resetting it to it's "0" so the item gets back the not selected color. Anyhow it looks like the TON function from library is not working in these FB that are instanced in the various visualizations, as instead they do if I create some instances within the POUS. Anyone has ideas of how to make them work?
Last updated: 2024-04-15

Post by salvadegianluca on How to use TON inside an FB that is instanced within a Visu page CODESYS Forge talk (Post)
Hi everyone; I'm building a project in which the drag of the mouse over some controls (or the click event) changes the background color of the control items; this change of color is made with an FB that assignes a color code to the background with MUX command based on the value of an enumerator, this part is perfectly working but, when I'm using a touchpanel instead of a web visu (controlled by a mouse) I get into some issues as it seems that the touch operations are not triggering the MouseEnter and MouseLeave properties as it's done with the mouse.... For this reason I'm trying to add a TON to my FB and, if the enum that changes color remains at the same state for more then 3s I'm automatically resetting it to it's "0" so the item gets back the not selected color. Anyhow it looks like the TON function from library is not working in these FB that are instanced in the various visualizations, as instead they do if I create some instances within the POUS. Anyone has ideas of how to make them work?
Last updated: 2024-04-15

Post by k2saki on CNC / G01 Speed is very slow (or go-stop motion) in Continuous short segment . CODESYS Forge talk (Post)
I'm using CAD/CAM that outputs GCode with G01 many short segments from NURBS Curve, only X-Y axis. But CODESYS CNC motion seems much slower ( or stop-go motion ) in simulation mode than F-Value (I checked value from SMC_Interpolator - dVel ). In GCode G01, F value is F500, but movement is very slow, actual speed (dVel) is between 0 to 30 back and forth. I think very old CNC can move like that, but nowadays, a lot of CNC can move smoothly to process free curve ( somethimes option switch ) I tried to use G51 Dxx but I got the same result. My questions are 1) How do I improve CODESYS CNC motion in this case ? 2) How can I graph the sampling from dVel of SMC_Interpolate in CODESYS? From my GCode N2006 G01 X1.4364 Y-14.6847 F500 N2007 G01 X1.6759 Y-14.6768 N2008 G01 X1.9152 Y-14.6486 N2009 G01 X2.1547 Y-14.6400 N2010 G01 X2.3943 Y-14.6090 N2011 G01 X2.6336 Y-14.6002 N2012 G01 X2.8732 Y-14.5716 N2013 G01 X3.1127 Y-14.5634 N2014 G01 X3.3520 Y-14.5410 N2015 G01 X3.5915 Y-14.5336 N2016 G01 X3.8308 Y-14.5307 ... Thansk.
Last updated: 2024-04-29

Post by timvh on License problem gateway CODESYS Forge talk (Post)
What we are trying to explain is that, yes CODESYS creates the software, but Epis decides how they implement it on their hardware, which runtime version they use and they decide which functionality they support. So it is always a combination of the two. What CODESYS provides is a runtime with options for e.g. visualization or softmotion. Epis could add this softmotion license as default to their controller, but if they don't then CODESYS provides another option with a single license in a "Wibu CodeMeter" container. Eventhough the feature exists, Epis has to add this "CodeMeter" software on their controller to be able to access the licenses in the container. We don't know if they did this. Then finally it depends on what type of runtime is on this controller and which license Epis is using. So if they have an OEM license (not an application based license), then most likely you will need the Softmotion license (not a number of axis). See https://store.codesys.com/en/codesys-softmotion-sl-bundle.html. But to be sure if this is supported by the Epis controller, you must ask Epis.
Last updated: 2024-04-30

Post by kblundy on Change the Opening Position of the Dialog using VU.FbOpenDialog CODESYS Forge talk (Post)
I hope the community can help me with this. I need to use the Visu Utils FbOpenDialog to control the opening and closing of a dialog. I have the Opening and Closing working, but I can’t get the dialogue's position to be controlled. The code looks like this: PROGRAM OPEN_DIALOG VAR xOpenLatchSettingDialog : BOOL; TopLeftDialog : VisuStructPoint ; fbOpenLatchSettingsDialog : VU.FbOpenDialog ; END_VAR IF xOpenLatchSettingDialog THEN xOpenLatchSettingDialog:= FALSE ; TopLeftDialog.iX := 100; TopLeftDialog.iY := 23; fbOpenLatchSettingsDialog(sDialogName := 'visu_AlarmLatchSettings', xExecute := xOpenLatchSettingDialog , xModal := TRUE, itfClientFilter := VU.Globals.OnlyTargetVisu, pTopLeftPosition := ADR(TopLeftDialog)); CloseVisuDialog(sDialogName:= 'visu_AlarmLatchSettings'); ELSE xOpenLatchSettingDialog:= TRUE ; IF fbOpenLatchSettingsDialog.xError THEN xOpenLatchSettingDialog := FALSE; END_IF END_IF I can't seem to work out a way to make the values in TopLeftDialog.iX and TopleftDialog.iY be passed correctly in the call and for it to change the position of the dialogue box. The code is compiled, but the position has not been changed. Any guidance or suggestions for revising this code would be incredibly valuable. Your insights could be the key to solving this issue.
Last updated: 2024-05-05

Post by tama00 on GPIOs not running with Raspberry Pi 4 (and SPI connection) CODESYS Forge talk (Post)
Hello everyone, I have a working SPI connection (with transferExt) between a Raspberry master with Codesys and an ESP32 slave. I would also like to use a few GPIO pins. Is there a problem with using SPI AND GPIOs? Environment: Raspberry Pi 4+ with Raspian from Oct 23 Codesys V3.4 SP19 Patch 5 with Runtime Version 4.10.0.0 Device: GPIOs B+/Pi2 My problem: The status is displayed as “GPIOs : not running”. And also during mapping the message “The bus is not running. The values shown are perhaps not actual”. However, the variable changes that I make in my program are displayed under “Current Value”. In the Logic Analyzer, the pin toggles during transmission with small intervals of +-4us (seems to be a cyclical disorder, but I don't know where exactly it could be coming from). This applies to pins that I actually use (output) but also to the other GPIOs (not used). With GPIO 4, the line remains permanently high. Attached is a screenshot from the Logic Analyzer. Channel 1,3,5 were GPIO pin 26, 22, 17 Would be very grateful for help. Best regards
Last updated: 2024-05-06

Post by nikgind on Codesys Communication Manger - Required information model version exists in the model repository but is not found CODESYS Forge talk (Post)
Hi I am trying to import a custom information model that I created using UA Modeler. I have only added two new methods and two new object types. It is possible to add the information model to the Communication Manager and the two new object types are shown in the Information Model tab. After compiling i get the following error: Communication Manager [Device: PLC Logic: Application]: The information model http://opcfoundation.org/UA/ is required by http://yourorganisation.org/Bsp_3.1/ with a minimal publication date from 15.12.2023 but the device has only a model from 15.09.2021 installed. Probably the information model from 15.09.2021 is missing in the information model repository. The error message does not make sense to me. Should it not be “Probably the information model from 15/12/2023 is missing in the information model repository”? Anyway I have installed the information model from 15/12/2023 but not from 15/09/2021. Which makes the error message even stranger.
Last updated: 2024-06-09

Post by fajean on CODESYS control on RPi starts, shortly runs, then exits CODESYS Forge talk (Post)
I have a Raspberry Pi 4 we have been using for years to run CODESYS for development purposes. I recently have had to re-install the OS (Raspberry OS lite). The only change to the default configuration is not creating the "pi" user during install. I (apparently successfully) installed the 4.10.0.0 control on the Raspberry Pi. We have licences on a dongle. I am able to start the control. systemctl status shows it as running for a little while (exactly, precisely 30 seconds as per my tests, every time), then it becomes exited. I can restart the control, and the same thing happens again. Every time. In the brief moments it is running, I can log in to the PLC. Working fast and restarting the control many times, I have been able to configure users. I have been able to download my application. I have been able to run the application, and stop on a breakpoint. I have been able to connect with the licence manager and confirm the dongle is detected and licences are listed as OK. I see nothing wrong until the service just exits. I have found nothing in the logs. It is like the runtime just terminates with no error code or message after exactly 30 seconds. Any help would be appreciated.
Last updated: 2024-06-13

Post by jonasz on Deploy LicenseServer for Linux SL CODESYS Forge talk (Post)
So here's how: I manually installed the following packages: codemeter-lite_8.30.6885.501_amd64.deb codesyslicenseserver_licenseserver_4.18.0.0_all.deb codesyswbmbase_wbmbase_4.18.0.0_all.deb codesyswbmlicensing_wbmlicensing_4.18.0.0_all.deb Of course, the license server appeared immediately. Trying to install it again using Install in the Deploy tab, the same error appears. Of course, the information that such a server is already installed is also there. Configuring PLC, S_PLC, EDGE, and SAFE_TIMER_PROVIDER went smoothly, and basically everything works. I wrote a simple program for S_PLC. I'm loading the programs into PLC and S_PLC. When loading the program into S_PLC, a message appears stating that there is no connection to the S_PLC controller. Timeout error. Restart the controller, attempt to load, and see the above. After changing the cycle time for S_PLC to 50ms, the problem no longer occurs. My question, besides the difficulty of installation for a new user, is what causes the cycle time for S_PLC to be so long, and how can I fix it?
Last updated: 2025-11-14

Post by baott569 on CODESYS OPC UA Security: HMI Client Not Receiving Server Certificate CODESYS Forge talk (Post)
Hello everyone, I am currently using OPC UA in CODESYS with the security mode BASIC256SHA256 – Signed and Encrypted. The OPC UA Server is running on an RTE CX device, and the HMI is running on another computer. I have reviewed many CODESYS documents and successfully established communication when the security mode is set to None with Anonymous login. However, when security is enabled, the server does not provide its certificate for the CODESYS HMI client to trust. Interestingly, the client can send its certificate to the server, and UAExpert works normally, but the CODESYS HMI client does not receive the server certificate. Can anyone help clarify what I might be missing? I have been stuck on this issue for three days. If I missed or misconfigured any step, please let me know. I believe I am stuck at step 15 in the following CODESYS guide: Encrypting the Communication of a Data Source OPC UA Client https://content.helpme-codesys.com/en/CODESYS%20Communication/_cds_encrypt_communication_data_sources_opc_ua_client.html Thank you very much.
Last updated: 2026-01-06

Post by tjacks on Opc UA Data Source Client Browse Error in Codesys HMI CODESYS Forge talk (Post)
Codesys V3.5 SP21 Patch 3 Codesys HMI 3.5.21.30 I'm trying to connect to an OPC UA server on a Kuka robot controller using Codesys HMI's data source manager. I get through the login phase and the client browses most of the data structure on the server but errors out toward the end with a generic: Error while browsing the client, Failed with service result: BadUnexpectedError. If I complete the data source setup and try to update variables, I get the attached stack trace for the error. I've tried several different endpoint and security options. Most get me through the login but all error out while browsing. UA Expert happily connects and browses with the same configuration. I've connected this same version of Codesys to TwinCAT OPC UA servers and Siemens PLC OPC UA servers. Any ideas on what may be causing the generic BadUnexpectedError during OPC UA server browse?
Last updated: 2025-11-17

Post by animesh on SoftPLC (CODESYS Control x86 RTE V3 x64) OPC UA binds only to 127.0.0.1 — Not binding to LAN IP CODESYS Forge talk (Post)
Hello everyone, I am facing a persistent issue with the OPC UA Server on Advantech Soft PLC with hard realtime for Win64 (V3_5_2010_3) and need help from the community. Device Information Name: Advantech Control x86 RTE V3 x64 Vendor: Advantech Co., Ltd. Categories: PLCs Version: 3.5.20.10 Description: Advantech Soft PLC with hard realtime for Win64 (V3_5_2010_3) Problem Summary The OPC UA Server works perfectly when accessed via: opc.tcp://localhost:4842 opc.tcp://<hostname>:4842</hostname> But it does NOT work when using the LAN IP: opc.tcp://192.168.0.XX:4842 In UAExpert I get: Discovery FindServers on opc.tcp://192.168.0.XX:4842 failed (BadCommunicationError) Port is LISTENING in windows Firewall.. Tried with turning off the firewall completely. System Information Windows 10 x64 Advantech CODESYS RTE Soft-PLC (hard real-time) Network IP: 192.168.0.XX Hostname: WINDOWS-XXXXX Need your Support
Last updated: 2025-11-24

Post by jv-certhon on Io driver Scan functionality CODESYS Forge talk (Post)
Hello, Codesys IDE is 3.5.21.30 IoDrvBase is: 3.5.17.8 I am working on implementing Codesys on our I/O product line, using the IO driver examples, and the Linux UDS socket approach. I have sucessfully created an implemetation where I have a Device with mutiple slots, on which I can plug modules. These modules represent our IO modules, and communication is successful. (For this question the assumtion can be made that Codesys commucates with 1 'master' device, which handles further communcation with the IO modules. For the next part of the question it can be assumed that the Master device has a list of which modules are attached/available) I'm now trying to implement the 'Scan for Devices...' feature, but I'm completetly lost on what to do once the IoDrvScanModules method is called in my IoDrvFB. I'm guessing that the ppConnectorList has to be filled with the found devices, but I have no idea if that is the correct approach. And Codesys is not triggering my breakpoints in the method, which makes things more difficult. I hope someone could provide some examples or guidance on what steps I should take to implement the scan feature. Thanks in advance.
Last updated: 2025-11-26

Post by baott569 on CODESYS OPC UA Security: HMI Client Not Receiving Server Certificate CODESYS Forge talk (Post)
Hello everyone, I am currently using OPC UA in CODESYS with the security mode BASIC256SHA256 – Signed and Encrypted. The OPC UA Server is running on an RTE CX device, and the HMI is running on another computer. I have reviewed many CODESYS documents and successfully established communication when the security mode is set to None with Anonymous login. However, when security is enabled, the server does not provide its certificate for the CODESYS HMI client to trust. Interestingly, the client can send its certificate to the server, and UAExpert works normally, but the CODESYS HMI client does not receive the server certificate. Can anyone help clarify what I might be missing? I have been stuck on this issue for three days. If I missed or misconfigured any step, please let me know. I believe I am stuck at step 15 in the following CODESYS guide: Encrypting the Communication of a Data Source OPC UA Client https://content.helpme-codesys.com/en/CODESYS%20Communication/_cds_encrypt_communication_data_sources_opc_ua_client.html Thank you very much.
Last updated: 2026-01-06

Post by mrkm-dic on CODESYS: Combining Master Redundancy with EtherCAT Ring Topology – Is it Supported? CODESYS Forge talk (Post)
Hello, I would like to ask whether it is technically supported (and practically achievable) to combine CODESYS Master Redundancy with EtherCAT ring (loop) redundancy in the same system. System setup CODESYS version: CODESYS 3.5.21.40 CODESYS Control SL for Weidmuller u-OS-4.12.2.0 Controllers (Masters): Weidmuller UC20-M4000 ×2, configured as Active / Standby using CODESYS redundancy EtherCAT Slaves: Weidmuller UR20-FBC-EC ×3, supporting EtherCAT ring / line break detection Topology: EtherCAT ring (loop) Main question Is it officially supported to use: ・CODESYS PLC/Master redundancy (Active/Standby) and ・EtherCAT ring topology (for cable redundancy) at the same time? Expected behavior Our expectation is: ・When the Active PLC fails, the Standby PLC becomes Active ・The Standby PLC then takes over the role of EtherCAT Master ・EtherCAT communication is re-established ・I/O control continues after reinitialization (a short interruption is acceptable; no strict bumpless requirement) We do not expect completely seamless / zero-cycle switchover, but we want to understand: ・Whether this combination is supported by design ・Or whether there are known limitations or restrictions when EtherCAT ring mode is used together with Master redundancy Clarification At this stage, the question is mainly about feasibility and support, not about a specific error message yet. Any official guidance, limitations, or real-world experience would be greatly appreciated. Thank you in advance.
Last updated: 4 days ago

Post by elizaduke92 on Temu Coupon Code 70% Off [acu639380] October 2024 CODESYS Forge talk (Post)
Are you ready to save big with the Temu coupon code 70% off? This incredible offer allows you to explore an array of products at unbeatable prices, making your shopping experience more enjoyable. The acu639380 Temu coupon code is designed to maximize benefits for shoppers in the USA, Canada, and European nations. Whether you’re a new user or a seasoned shopper, this code opens the door to exceptional savings. Looking for the latest deals? Our Temu coupon code 2024 for existing customers and the Temu 70% discount coupon can help you find fantastic bargains, ensuring you never miss a great deal. Dive into this article to discover how to make the most of these amazing offers! What Is The Temu Coupon Code 70% Off? The Temu coupon 70% off is a fantastic opportunity for both new and existing customers to enjoy significant discounts on a wide range of products. By utilizing the 70% off Temu coupon code, you can unlock remarkable savings on your purchases. Here are the key benefits of using the acu639380 coupon code: Up to 70% off for new users: Enjoy an incredible discount on your first purchase, making it easy to try Temu's extensive product selection. 70% extra off for existing users: Loyal customers can also take advantage of this offer, ensuring everyone benefits from amazing discounts. Flat $100 off for new Temu users: Kickstart your shopping journey with a generous $100 discount, providing even more value. $100 coupon pack for multiple uses: With this feature, you can spread your savings over several purchases, maximizing the use of your coupon. $100 flat discount for new Temu customers: This significant savings opportunity makes it easier for new users to explore Temu's offerings. Extra $100 off promo code for existing customers: Returning users will love the added savings, making it worthwhile to continue shopping at Temu. $100 coupon for USA/Canada/European users: This code is designed specifically to cater to shoppers in these regions, enhancing their shopping experience. Temu Coupon Code 70% Off For New Users New users have a unique advantage when they use our coupon code on the Temu app. The Temu coupon 70% off offers an excellent chance to make your first purchase without breaking the bank. Here’s what new users can gain with the acu639380 code: Flat 70% discount for new users: This fantastic offer means your first order is significantly reduced, helping you save more. $100 coupon bundle for new customers: Enjoy a special bundle that amplifies your shopping experience right from the start. Up to $100 coupon bundle for multiple use: Use this bundle across various products, making your shopping more flexible. Free shipping to 68 countries: New users can benefit from free shipping, ensuring that your items arrive without extra charges. Extra 40% off on any purchase for first-time users: Combine this with your first-order discount to save even more. How To Redeem The Temu 70% Off Coupon Code For New Customers? Using the Temu 70% off coupon code is simple! Follow these steps to redeem your Temu 70 off coupon code: Download the Temu App: Install the app on your device or visit the Temu website. Create an Account: Sign up as a new user to access exclusive deals. Browse Products: Shop for your desired items and add them to your cart. Enter Coupon Code: On the checkout page, input acu639380 in the designated coupon code field. Enjoy Your Savings: Review your order and complete your purchase with the applied discount! Temu Coupon Code 70% Off For Existing Users Existing users are also in for a treat with the acu639380 coupon code on the Temu app. The Temu 70 off coupon code allows loyal customers to continue enjoying great savings. Here are the perks available for existing users: 70% discount for existing Temu users: This fantastic offer ensures that returning customers still receive significant discounts. A $100 coupon bundle for multiple purchases: Ideal for those who love to shop frequently, this bundle helps maximize savings over time. Free gift with express shipping all over the USA/Canada: Enjoy a surprise gift with your order, plus quick delivery options. Extra 30% off on top of existing discount: Stack your savings for an even better deal on your purchases. Free shipping to 68 countries: Just like new users, existing customers benefit from free shipping, enhancing their shopping experience. How To Use The Temu Coupon Code 70% Off For Existing Customers? Redeeming your Temu coupon code 70 off as an existing customer is straightforward! Here’s how to use the Temu discount code for existing users: Log in to Your Account: Access your Temu account on the app or website. Shop Your Favorite Products: Browse the extensive catalog and add items to your cart. Go to Checkout: When ready to purchase, proceed to the checkout page. Enter the Coupon Code: In the coupon code box, enter acu639380 to apply your discount. Complete Your Order: Finalize your order with the applied savings, and enjoy your purchase! How To Find The Temu Coupon Code 70% Off? Finding the Temu coupon code 70% off first order is easy! One of the best ways to get verified and tested coupons is by signing up for the Temu newsletter. Additionally, keep an eye on Temu’s social media pages for the latest promotions and discounts. You can also find the latest and working Temu coupon codes by visiting trusted coupon sites that offer regular updates on available deals. How Temu 70% Off Coupons Work? The Temu coupon code 70% off first time user works by providing significant discounts on your purchases. When you enter the coupon code at checkout, it reduces the total amount, allowing you to enjoy remarkable savings. This system is designed to incentivize both new and existing customers to shop more frequently. Each code offers different benefits, making it a versatile option for everyone. How To Earn 70% Off Coupons In Temu As A New Customer? You can easily earn the Temu coupon code 70% off by taking advantage of promotional offers available to new users. By signing up for an account and subscribing to their newsletter, you’ll receive exclusive access to discounts like the Temu 70 off coupon code first order. This approach not only helps you save on your initial purchase but also keeps you informed about ongoing deals and promotions tailored for new shoppers. What Are The Advantages Of Using Temu 70% Off Coupons? The Temu 70% off coupon code legit is not just about discounts; it’s a gateway to an enhanced shopping experience. Here’s a quick look at the advantages of using our coupon code on the Temu app and website: A 70% discount on the first order. A $100 coupon bundle for multiple uses. A 70% discount on popular items. 70% off for existing Temu customers. Up to 70% off in selected items. A free gift for new users. Free delivery to 68 countries. Temu Free Gift And Special Discount For New And Existing Users Using our Temu 70% off coupon code unlocks a treasure trove of benefits for both new and existing users. Here’s how the 70% off Temu coupon code can elevate your shopping experience: 70% discount for first order: New users can take advantage of this incredible offer right away. Extra 30% off on any item: Maximize your savings with additional discounts. Free gift for new Temu users: Enjoy a special surprise alongside your first purchase. Up to 70% discount on any item on the Temu app: Shop across categories and find amazing deals. Free gift with free shipping in 68 countries including the USA and UK: Enjoy seamless shopping with added perks. Pros And Cons Of Using Temu Coupon Code 70% Off When considering the Temu coupon 70% off code, it’s essential to weigh the pros and cons: Pros Significant savings on your first order. Multiple uses for loyal customers. Free shipping to various countries. Access to exclusive offers and bundles. Free gifts for new and returning users. Cons Coupons may have restrictions on certain items. Some promotions might expire quickly. Limited availability for specific geographical locations. Terms And Conditions Of The Temu 70% Off Coupon Code In 2024 Understanding the Temu coupon code 70% off free shipping conditions is crucial for maximizing your savings. Here are the important terms: The coupon code doesn’t have any expiration date, so you can use it anytime. Valid for both new and existing users in 68 countries worldwide. No minimum purchase requirements for using our Temu coupon code. Certain items may be excluded from the discount. Final Note In conclusion, the Temu coupon code 70% off is your ticket to amazing savings on a wide variety of products. Whether you’re a new or existing customer, there’s something for everyone with this fantastic offer. Don’t miss out on the incredible savings opportunities provided by the Temu 70% off coupon—start shopping today and enjoy all the benefits that come with it! FAQs Of Temu 70% Off Coupon 1. Can I use the Temu coupon code more than once? Yes, the Temu coupon code 70% off can be used multiple times depending on the specific terms associated with your account. How long is the coupon valid? The Temu coupon code 70% off does not have an expiration date, allowing you to use it whenever you want. Is free shipping included with the coupon? Yes, the coupon allows for free shipping to 68 countries, enhancing your shopping experience. Are there any exclusions for the coupon? Certain items may be excluded from the discount; please check the terms before applying the coupon. How can I find the latest Temu coupons? You can sign up for the Temu newsletter or follow their social media for updates on the latest offers and promotions.
Last updated: 2024-10-26

Post by svenkaro on Codesyscontrol.service stoppt nach 30s CODESYS Forge talk (Post)
Hallo nano, anbei das Logfile ;********* ;<loggername>codesyscontrol.log</loggername> ;<logoptions> ; <enable>1</enable> ; <type>normal</type> ; <timestamp>rtc high resolution</timestamp> ; <deactivatable>0</deactivatable> ; <dump>always</dump> ; <filter>0x0000000f<filter> ; <maxentries>100000</maxentries> ; <maxfiles>1</maxfiles> ; <maxfilesize>1000000</maxfilesize> ;</filter></filter></logoptions> ;<entries> ;Timestamp, CmpId, ClassId, ErrorId, InfoId, InfoText ;ClassId: LOG_INFO =1 ;ClassId: LOG_WARNING =2 ;ClassId: LOG_ERROR =4 ;ClassId: LOG_EXCEPTION =8 ;ClassId: LOG_DEBUG =16 ;ClassId: LOG_PRINTF =32 ;ClassId: LOG_COM =64 ;</entries> ;********* 2024-06-20T06:07:12.085Z, 0x0000013d, 16, 0, 0, OpenCpusetCpusEffective: using core(s) "0-3" from /sys/fs/cgroup/cpuset.cpus.effective 2024-06-20T06:07:12.085Z, 0x00000109, 16, 0, 0, SysModuleLoad: libCmpBACnet.so: 0x92ae530 2024-06-20T06:07:12.085Z, 0x00000109, 16, 0, 0, SysModuleLoad: libCmpBACnet2.so: 0x92af008 2024-06-20T06:07:12.085Z, 0x00000109, 16, 0, 0, SysModuleLoad: libCmpPLCHandler.so: 0x92afb08 2024-06-20T06:07:12.085Z, 0x00000109, 16, 0, 0, SysModuleLoad: libCmpGwClient.so: 0x92affe8 2024-06-20T06:07:12.085Z, 0x00000109, 16, 0, 0, SysModuleLoad: libCmpXMLParser.so: 0x92b04c0 2024-06-20T06:07:12.085Z, 0x00000109, 16, 0, 0, SysModuleLoad: libCmpGwClientCommDrvTcp.so: 0x92b09a0 2024-06-20T06:07:12.086Z, 0x00000013, 1, 0, 0, <logoptions> 2024-06-20T06:07:12.086Z, 0x00000013, 1, 0, 0, <benable>1</benable> 2024-06-20T06:07:12.086Z, 0x00000013, 1, 0, 0, <type>normal</type> 2024-06-20T06:07:12.086Z, 0x00000013, 1, 0, 0, <timestamp>rtc high resolution</timestamp> 2024-06-20T06:07:12.086Z, 0x00000013, 1, 0, 0, <disableable>0</disableable> 2024-06-20T06:07:12.086Z, 0x00000013, 1, 0, 0, <filter>0x0000000f</filter> 2024-06-20T06:07:12.086Z, 0x00000013, 1, 0, 0, <maxentries>100000</maxentries> 2024-06-20T06:07:12.086Z, 0x00000013, 1, 0, 0, <maxfiles>1</maxfiles> 2024-06-20T06:07:12.086Z, 0x00000013, 1, 0, 0, <maxfilesize>1000000</maxfilesize> 2024-06-20T06:07:12.086Z, 0x00000013, 1, 0, 0, </logoptions> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>CM</cmp>, <id>0x00000001</id> <ver>3.5.19.61</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>CmpMemPool</cmp>, <id>0x0000001e</id> <ver>3.5.19.60</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>CmpLog</cmp>, <id>0x00000013</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>CmpSettings</cmp>, <id>0x0000001a</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysFile</cmp>, <id>0x00000104</id> <ver>3.5.19.50</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>CmpMemGC</cmp>, <id>0x0000001f</id> <ver>3.5.19.20</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysCom</cmp>, <id>0x00000100</id> <ver>3.5.19.10</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysCpuHandling</cmp>, <id>0x00000101</id> <ver>3.5.19.20</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysCpuMultiCore</cmp>, <id>0x0000013d</id> <ver>3.5.19.20</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysCrypto</cmp>, <id>0x00000141</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysDir</cmp>, <id>0x0000011b</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysEthernet</cmp>, <id>0x0000011c</id> <ver>3.5.19.20</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysEvent</cmp>, <id>0x00000102</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysExcept</cmp>, <id>0x00000103</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysInternalLib</cmp>, <id>0x00000107</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysMem</cmp>, <id>0x00000108</id> <ver>3.5.19.50</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysModule</cmp>, <id>0x00000109</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysMsgQ</cmp>, <id>0x0000010a</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysMutex</cmp>, <id>0x0000013a</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysOut</cmp>, <id>0x0000010b</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysProcess</cmp>, <id>0x0000010e</id> <ver>3.5.19.50</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysSem</cmp>, <id>0x0000010f</id> <ver>3.5.19.10</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysSemCount</cmp>, <id>0x00000139</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysSemProcess</cmp>, <id>0x00000119</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysShm</cmp>, <id>0x00000110</id> <ver>3.5.19.50</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysSocket</cmp>, <id>0x00000111</id> <ver>3.5.19.30</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysTarget</cmp>, <id>0x00000112</id> <ver>3.5.19.61</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysTask</cmp>, <id>0x00000114</id> <ver>3.5.19.10</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysTime</cmp>, <id>0x00000115</id> <ver>3.5.19.10</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysTimeRtc</cmp>, <id>0x00000127</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, System: <cmp>SysTimer</cmp>, <id>0x00000116</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpAlarmManager</cmp>, <id>0x0000007c</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpApp</cmp>, <id>0x00000002</id> <ver>3.5.19.60</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpAppBP</cmp>, <id>0x00000073</id> <ver>3.5.19.20</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpAppForce</cmp>, <id>0x00000074</id> <ver>3.5.19.20</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpAsyncMgr</cmp>, <id>0x0000005f</id> <ver>3.5.19.20</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpAuditLog</cmp>, <id>0x000000a1</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpBinTagUtil</cmp>, <id>0x00000004</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpBinTagUtilIec</cmp>, <id>0x0000005c</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpBitmapPool</cmp>, <id>0x00000050</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpBlkDrvTcp</cmp>, <id>0x00000030</id> <ver>3.5.19.50</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpBlkDrvUdp</cmp>, <id>0x00000007</id> <ver>3.5.19.30</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAAAsyncMan</cmp>, <id>0x00004007</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAABehaviourModel</cmp>, <id>0x00004015</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAACallback</cmp>, <id>0x00004001</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAACanL2</cmp>, <id>0x00004004</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAADTUtil</cmp>, <id>0x00004013</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAAFile</cmp>, <id>0x00004008</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAAMemBlockMan</cmp>, <id>0x00004003</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAANetBaseServices</cmp>, <id>0x00004018</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAARealTimeClock</cmp>, <id>0x00004014</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAASdoClient</cmp>, <id>0x00004011</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAASdoServer</cmp>, <id>0x00004017</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAASegBufferMan</cmp>, <id>0x00004019</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAASerialCom</cmp>, <id>0x00004012</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAAStorage</cmp>, <id>0x0000007e</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAATick</cmp>, <id>0x00004009</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAATickUtil</cmp>, <id>0x00004010</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAATimer</cmp>, <id>0x00004016</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCAATypes</cmp>, <id>0x00004006</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpChannelClient</cmp>, <id>0x00000008</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpChannelClientIec</cmp>, <id>0x0000005d</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpChannelMgr</cmp>, <id>0x00000009</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpChannelServer</cmp>, <id>0x0000000a</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCharDevice</cmp>, <id>0x00000300</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpChecksum</cmp>, <id>0x0000000b</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCodeMeter</cmp>, <id>0x0000007a</id> <ver>3.5.19.50</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCommunicationLib</cmp>, <id>0x0000000c</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCoreDump</cmp>, <id>0x00000083</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpCryptMD5</cmp>, <id>0x0000006a</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpDevice</cmp>, <id>0x0000000e</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpDynamicText</cmp>, <id>0x00000051</id> <ver>3.5.19.30</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpEL6751CanDrv</cmp>, <id>0x00005f0b</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpEventMgr</cmp>, <id>0x0000005b</id> <ver>3.5.19.30</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpEventMgrUnixBackend</cmp>, <id>0x000000a4</id> <ver>4.11.0.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpFileTransfer</cmp>, <id>0x0000005e</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpIecStringUtils</cmp>, <id>0x0000007f</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpIecTask</cmp>, <id>0x00000011</id> <ver>3.5.19.30</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpIecVarAccess</cmp>, <id>0x00000060</id> <ver>3.5.19.30</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpIoDrvIec</cmp>, <id>0x0000005a</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpIoMgr</cmp>, <id>0x00000012</id> <ver>3.5.19.30</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpKnxStack</cmp>, <id>0x0000004d</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpLinuxInterrupt</cmp>, <id>0x000000a2</id> <ver>3.5.17.10</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpLinuxRTDiag</cmp>, <id>0x000000a7</id> <ver>4.11.0.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpMonitor2</cmp>, <id>0x00000032</id> <ver>3.5.19.20</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpNameServiceClient</cmp>, <id>0x00000015</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpNameServiceClientIec</cmp>, <id>0x0000011d</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpNameServiceServer</cmp>, <id>0x00000016</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpOPCUAClient</cmp>, <id>0x00000096</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpOPCUAProviderIecVarAccess</cmp>, <id>0x00000126</id> <ver>3.5.19.50</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpOPCUAServer</cmp>, <id>0x00000124</id> <ver>3.5.19.30</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpOPCUAStack</cmp>, <id>0x0000008d</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpOpenSSL</cmp>, <id>0x00000033</id> <ver>3.5.19.61</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpPlcShellLinux</cmp>, <id>0x00000128</id> <ver>4.11.0.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpPlcShellLinuxBackend</cmp>, <id>0x000000a5</id> <ver>4.11.0.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpRasPi</cmp>, <id>0x00000089</id> <ver>4.11.0.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpRedundancy</cmp>, <id>0x00000129</id> <ver>3.5.19.30</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpRedundancyConnectionIP</cmp>, <id>0x0000ff03</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpRetain</cmp>, <id>0x00000017</id> <ver>3.5.19.50</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpRouter</cmp>, <id>0x00000018</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpRunStopSwitch</cmp>, <id>0x000000a6</id> <ver>4.11.0.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpSchedule</cmp>, <id>0x00000019</id> <ver>3.5.19.50</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpSecureChannel</cmp>, <id>0x00000090</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpSecurityManager</cmp>, <id>0x0000008e</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpSessionInformation</cmp>, <id>0x00000097</id> <ver>3.5.19.20</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpSocketCanDrv</cmp>, <id>0x00005f0d</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpSocketUnix</cmp>, <id>0x000000a3</id> <ver>4.11.0.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpSrv</cmp>, <id>0x0000001c</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpTraceMgr</cmp>, <id>0x00000070</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpUserDBFile</cmp>, <id>0x00000098</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpUserGroupsDBFile</cmp>, <id>0x00000099</id> <ver>3.5.19.50</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpUserMgr</cmp>, <id>0x00000061</id> <ver>3.5.19.50</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpUserObjectsDBFile</cmp>, <id>0x0000009c</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpVisuHandler</cmp>, <id>0x00000054</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpVisuServer</cmp>, <id>0x00000057</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpWebServer</cmp>, <id>0x00000071</id> <ver>3.5.19.30</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, <cmp>CmpWebServerHandlerV3</cmp>, <id>0x00000072</id> <ver>3.5.19.10</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, Dynamic: <cmp>CmpBACnet</cmp>, <id>0x00000400</id> <ver>3.5.19.50</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, Dynamic: <cmp>CmpBACnet2</cmp>, <id>0x00000401</id> <ver>3.5.19.10</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, Dynamic: <cmp>CmpPLCHandler</cmp>, <id>0x0000002a</id> <ver>3.5.19.61</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, Dynamic: <cmp>CmpGwClient</cmp>, <id>0x00000021</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, Dynamic: <cmp>CmpXMLParser</cmp>, <id>0x00000058</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.086Z, 0x00000001, 1, 0, 10, Dynamic: <cmp>CmpGwClientCommDrvTcp</cmp>, <id>0x00000022</id> <ver>3.5.19.0</ver> 2024-06-20T06:07:12.125Z, 0x0000013d, 1, 0, 4, MultiCore support: [activated], all cores are used 2024-06-20T06:07:12.125Z, 0x0000013d, 1, 0, 4, Number of available cores: 4 2024-06-20T06:07:12.134Z, 0x00000401, 2, 0, 0, !!!! Warning: component CmpBACnet loaded already 2024-06-20T06:07:12.184Z, 0x00000007, 1, 0, 6, Network interface: <ipaddress>10.94.25.39</ipaddress>, subnetmask <subnetmask>255.255.255.0</subnetmask> 2024-06-20T06:07:12.184Z, 0x00000018, 1, 0, 4, Network interface <interface>ether 2</interface> at router <instance>0</instance> registered 2024-06-20T06:07:12.185Z, 0x00000009, 1, 0, 2, Running as network server 2024-06-20T06:07:12.185Z, 0x00000009, 1, 0, 1, Running as network client 2024-06-20T06:07:12.186Z, 0x0000000a, 1, 0, 0, <numofchannels>4</numofchannels> channels available, each of the size <buffersize>100000</buffersize> Bytes 2024-06-20T06:07:12.254Z, 0x00000400, 1, 0, 0, CmpBACnet 1024 BACstack information 2024-06-20T06:07:12.254Z, 0x00000400, 1, 0, 0, version = 15.0.1.1 2024-06-20T06:07:12.254Z, 0x00000400, 1, 0, 0, __BYTE_ORDER = 1234 2024-06-20T06:07:12.254Z, 0x00000400, 1, 0, 0, TARGET_IEEE_FP_FORMAT = 1 2024-06-20T06:07:12.254Z, 0x00000400, 1, 0, 0, TARGET_FP_BIG_ENDIAN = 0 2024-06-20T06:07:12.254Z, 0x00000400, 1, 0, 0, TARGET_DP_BIG_ENDIAN = 0 2024-06-20T06:07:12.254Z, 0x00000400, 1, 0, 0, TARGET_INTEGRAL_BIG_ENDIAN = 0 2024-06-20T06:07:12.254Z, 0x00000400, 1, 0, 0, TARGET_USED_ALIGNMENT = 4 2024-06-20T06:07:12.254Z, 0x00000401, 1, 0, 0, CmpBACnet2 1025 BACstack information 2024-06-20T06:07:12.254Z, 0x00000401, 1, 0, 0, version = 25.1.5.1 2024-06-20T06:07:12.254Z, 0x00000401, 1, 0, 0, __BYTE_ORDER = 1234 2024-06-20T06:07:12.254Z, 0x00000401, 1, 0, 0, TARGET_IEEE_FP_FORMAT = 1 2024-06-20T06:07:12.254Z, 0x00000401, 1, 0, 0, TARGET_FP_BIG_ENDIAN = 0 2024-06-20T06:07:12.254Z, 0x00000401, 1, 0, 0, TARGET_DP_BIG_ENDIAN = 0 2024-06-20T06:07:12.254Z, 0x00000401, 1, 0, 0, TARGET_INTEGRAL_BIG_ENDIAN = 0 2024-06-20T06:07:12.254Z, 0x00000401, 1, 0, 0, TARGET_MCU_USED_ALIGNMENT = 4 2024-06-20T06:07:12.261Z, 0x00000129, 1, 0, 0, Debug Messages not activated 2024-06-20T06:07:12.262Z, 0x0000ff03, 1, 0, 0, Read connection settings... 2024-06-20T06:07:12.266Z, 0x00000030, 1, 0, 6, Local network address: <ipaddress>10.94.25.39</ipaddress> 2024-06-20T06:07:12.266Z, 0x00000018, 1, 0, 4, Network interface <interface>BlkDrvTcp</interface> at router <instance>1</instance> registered 2024-06-20T06:07:12.272Z, 0x00000124, 1, 0, 0, No certificate for the OPC UA server available. 2024-06-20T06:07:12.272Z, 0x00000124, 1, 0, 0, Security policy allows plain text communication. Secure communication is deactivated. 2024-06-20T06:07:12.272Z, 0x00000124, 1, 0, 0, ********** 2024-06-20T06:07:12.272Z, 0x00000124, 1, 0, 0, OPC UA Server Started: 2024-06-20T06:07:12.272Z, 0x00000124, 1, 0, 0, Hostname: raspberrypi, Port: 4840 2024-06-20T06:07:12.272Z, 0x00000124, 1, 0, 0, URL: opc.tcp://raspberrypi:4840 2024-06-20T06:07:12.272Z, 0x00000124, 1, 0, 0, Loopbackadapter activated. 2024-06-20T06:07:12.272Z, 0x00000124, 1, 0, 0, All available networkadapters are used. 2024-06-20T06:07:12.272Z, 0x00000124, 1, 0, 0, Multithreading activated. 3 workers used. 2024-06-20T06:07:12.272Z, 0x00000124, 1, 0, 0, ************ 2024-06-20T06:07:12.286Z, 0x00000124, 1, 0, 0, Provider 'CODESYS_DefaultProvider' (version 0x305131e) registered at the OPC UA server. 2024-06-20T06:07:12.287Z, 0x000000a6, 1, 0, 0, Not able to read file of Run/Stop switch. Functionality of component disabled 2024-06-20T06:07:12.306Z, 0x00000001, 1, 0, 0, ========================================================================= 2024-06-20T06:07:12.306Z, 0x00000001, 1, 0, 4, CODESYS Control for Raspberry Pi MC SL 2024-06-20T06:07:12.306Z, 0x00000001, 1, 0, 4, OS=Linux, CPU=ARM, Arch=32Bit, Coding=C 2024-06-20T06:07:12.306Z, 0x00000001, 1, 0, 6, <version>3.5.19.61</version> <builddate>Feb 22 2024</builddate> 2024-06-20T06:07:12.306Z, 0x00000001, 1, 0, 5, Copyright CODESYS Development GmbH 2024-06-20T06:07:12.306Z, 0x00000001, 1, 0, 0, ========================================================================= 2024-06-20T06:07:12.308Z, 0x00000124, 1, 0, 0, Provider 'AddressSpaceFragment Provider' (version 0x3051332) registered at the OPC UA server. 2024-06-20T06:07:12.309Z, 0x00000124, 1, 0, 0, Provider 'OPC UA for IEC-61131-3' (version 0x3051332) registered at the OPC UA server. 2024-06-20T06:07:12.309Z, 0x00000124, 1, 0, 0, Provider 'AlarmManager' (version 0x3051332) registered at the OPC UA server. 2024-06-20T06:07:12.321Z, 0x00000018, 1, 0, 1, Setting router <instance>0</instance> address to (0027) 2024-06-20T06:07:12.321Z, 0x00000018, 1, 0, 1, Setting router <instance>1</instance> address to (2ddc:0a5e:1927) 2024-06-20T06:07:12.332Z, 0x00000001, 1, 0, 34, CODESYS Control ready 2024-06-20T06:07:12.333Z, 0x00000001, 2, 0, 0, !!!! Warning: no runtime license - running in demo mode(~2 hours) Wäre der Zeitraum nicht nur 30s könnte ich das beenden auf Grund der letzten Zeile nachvollziehen. Hoffe Du hast eine Idee, vielen Dank.
Last updated: 2024-06-20

Post by mubeta on Some 'pathetic' errors in SoftMotion program CODESYS Forge talk (Post)
Yes, this is the error the sometimes show up. What make me crazy is the fact that it happens randomly and not each times. I know very well where the problem is, in wich one program row it's located. For each actions of the state machine I have all events recorded with log on text file. it is not problematic for me to find the application point of the fault, but I need to understand why occasionally and for no apparent reason, switching the state machine and thus changing the motion FB, sends the axis into failure (but only occasionally). For example, one case that is often problematic is the execution of the Axis Halt instruction. When, after a MoveAbosulte instruction this returns the event as 'done' and indeed the axis is in standstill, the state machine first sets the move instruction to FALSE, and the next cycle sets the Halt request to TRUE. Some of the time everything works out fine. Occasionally, however, in this exchange, the axis goes into fault, also losing the OPERATIONAL state. Meanwhile, I would like to understand why the motion FB instances must still be called even after the Execute is set to FALSE, especially in view of the fact that the next instruction is programmed to abort the previous one, with BufferMode set to 'Aborting'. All these unnecessary FB calls are an unnecessary overhead on the CPU anyway. Is there any precise rule about when to cease calling the various instances? (It should precisely be the 'done' status that says this one has finished its work).
Last updated: 2024-07-18

Post by cer-wa on Not able to connect multiple profinet encoder in codesys Linux ARM64 CODESYS Forge talk (Post)
Hello, currently im working with a RevPi connect 5 on a codesys project. Up until now I was having a blast because things were going really smooth but for like almost a day im kind of stuck on the integration of multiple profinet sensors into my project. This is kind of a bummer because that should be an easy thing to do. What I tried so far was to create and additional ethernet adapter where I then tried to connect my devices. in the beginning I tried to connect the devices directly which was not working because I could assign the IP-adress only to the ethernet adapter and not to the devices but the device was found in the device repository (this gets important in the second part) So what I tried next was to setup a PN-Controller and connect my devices subsequently to the Controller. Sadly now the devices wont show up in the device repository anymore. To me its not clear why this is happening. And the worst thing is: I went ahead and setup a device completely like I would want to have it in the project and when I then click on scan devices I can even find the device. But it can not be added to project for whatever reason eventhough im 100% certain that the gsdml file is the correct one. Can anyone help me with this. Like I said this seems like an easy thing to do and its taking me way longer than expected already. The only thing that came to my mind why this might not work is because I have codesys license which only allows one profinet instance. Could that be the case? The error message seems then pretty unfit but ok. I will be grateful for every advice. Thanks in advance! Best regards!
Last updated: 2025-09-25

Post by jst69 on Python script: Launch Codesys, Execute Script, Exit Codesys CODESYS Forge talk (Post)
Dear all: Question about scripting: I am creating a .NET program that is supposed to Open codesys, open template project, export a bunch of pou, then exit codesys. Launch works, Open project works, Export works, But how do i tell codesys to close itself? I can tell windows to terminate codesys, but i would prefer to do it properly. from __future__ import print_function import sys import System proj = projects.primary # We're interested in POU nodes: POUGuid = Guid("6f9dac99-8de1-4efc-8465-68ac443b7d08") # We collect all POU nodes in that list. pous = [] # From the parent node on, we recursively add POU nodes: def CollectPous(node): if node.type == POUGuid: pous.append(node) else: for child in node.get_children(): CollectPous(child) # Now we collect all the leaf nodes. for node in proj.get_children(): CollectPous(node) # We print everything just to know what's going on. for i in pous: print("found: ", i.type, i.guid, i.get_name()) # And now we export the files. for candidate in pous: # We create a list of objects to export: # The object itsself objects = [candidate] # And sub-objects (POUs can have actions, properties, ...) objects.extend(candidate.get_children()) # And the parent folders. parent = candidate.parent while ((not parent.is_root) and parent.is_folder): objects.append(parent) parent = parent.parent # Create an unique file name: if len(sys.argv) == 1: filename = "parent\\%s.export" % (candidate.get_name()) else: filename = "%s\\%s.export" % (sys.argv[1],candidate.get_name()) # print some user information print("exporting ", len(objects), " objects to: ", filename) # and actually export the project. proj.export_xml(objects, filename) proj.close() print ("script finished.") System.exit(0) // Dont work .NET: public static void Export(string path,string proj) { if (checkSettings()) { var p = new System.Diagnostics.Process(); p.StartInfo.FileName = Properties.Settings.Default.CSVersion +"\\CODESYS\\Common\\CODESYS.exe"; p.StartInfo.Arguments = " --Profile=" + qoute(Properties.Settings.Default.CSProfile) + " --culture=en" + " --project=" + qoute(path + "\\" + proj) + " --runscript=" + Properties.Settings.Default.LastOpenProjectPath + "\\INPUT_DATA\\SCRIPT\\Export.py" + " --scriptargs:" + qoute(path) ; p.StartInfo.RedirectStandardOutput = true; p.StartInfo.UseShellExecute = false; p.StartInfo.CreateNoWindow = false; p.Start(); p.StandardOutput.ReadToEnd(); p.CloseMainWindow(); p.Close(); } }
Last updated: 2024-01-16

Post by umdee on Error when monitoring LAD programs CODESYS Forge talk (Post)
I get the following error when monitoring my program (see attached screenshots): "Unhandled exception has occured in your application. If you click Continue, the application will ignore this error and attempt to continue. If you click Quit, the application will close immediately. Value cannot be null. Parameter name: source. And the details say: See the end of this message for details on invoking just-in-time (JIT) debugging instead of this dialog box. ** Exception Text ** System.ArgumentNullException: Value cannot be null. Parameter name: source at System.Linq.Enumerable.Any[TSource] (IEnumerable1 source, Func2 predicate) at _3S.CoDeSys.NWLEditor.NWLTextCell.OnPaintCellLayer(PaintEventArgs e) at _3S.CoDeSys.Controls.Controls.GfxEdControl.PaintCellCellLayer(PaintEventArgs e, GfxCell cell) at _3S.CoDeSys.Controls.Controls.GfxEdControl.PaintCellCellLayer(PaintEventArgs e, GfxCell cell) at _3S.CoDeSys.Controls.Controls.GfxEdControl.PaintCellCellLayer(PaintEventArgs e, GfxCell cell) at _3S.CoDeSys.Controls.Controls.GfxEdControl.OnPaint(PaintEventArgs e) at System.Windows.Forms.Control.PaintWithErrorHandling(PaintEventArgs e, Int16 layer) at System.Windows.Forms.Control.WmPaint(Message& m) at System.Windows.Forms.Control.WndProc(Message& m) at System.Windows.Forms.UserControl.WndProc(Message& m) at _3S.CoDeSys.Controls.Controls.GfxEdControl.WndProc(Message& m) at System.Windows.Forms.NativeWindow.Callback(IntPtr hWnd, Int32 msg, IntPtr wparam, IntPtr lparam) ** Loaded Assemblies ** (3000 lines of assemblies) ** JIT Debugging ** To enable just-in-time (JIT) debugging, the .config file for this application or computer (machine.config) must have the jitDebugging value set in the system.windows.forms section. The application must also be compiled with debugging enabled. For example: <configuration> <system.windows.forms jitdebugging="true"> </system.windows.forms></configuration> When JIT debugging is enabled, any unhandled exception will be sent to the JIT debugger registered on the computer rather than be handled by this dialog box The windows show red X's where the networks should be. Any advice on how to fix this? Additional Information PLC used: Wago 750-8212, Firmware FW26 Startup profile: CODESYS V3.5 SP19 Patch 5 OS version: Microsoft Windows NT 10.0.22631.0 .NET version: 4.0.30319.42000 Full Version info attached as .txt
Last updated: 2024-03-17

Post by martinlithlith on Device User Logon and No device is responding.. Pi4b codesys 3.5 SP19 2 + (64-bit) CODESYS Forge talk (Post)
Hi! Im slowly starting to loose it and i need som help! After a few night of reading up and testing i´m still stuck as a rock and you guys and girls are my last resort for this project. Basic facts; Win 11 Codesys 3.5 SP19 2 + (64-bit) Raspberry pi 4 model b 2 gb Raspian release 11 aarch64 What keeps me up late at night; Username and Password when trying to connect to device and device only beeing connectable for a few seconds. Some of the things I have tried; Username and passord; Credientials from the raspberry Administrator Administrator admin admin Admin Admin administrator administrator Usernames and passwords that I sometimes use (this was a longshot i know, but i was running out of ideas and energy). :) Epand filesystem, activating i2c, spi, 1-wire I can start the gateway and start the runtime. I cant install the edgearm64, arm64 runtime package eventhough I guess i should, i get code [ERROR] Error output: dpkg: error processing archive /tmp/codesysedge_edgearm64_4.8.0.0_arm64.deb (--install): [ERROR] Error output: package architecture (arm64) does not match system (armhf) [ERROR] Error output: Errors were encountered while processing: [ERROR] Error output: /tmp/codesysedge_edgearm64_4.8.0.0_arm64.deb code as a respons. I have tried to Reset Origin Device - no change. I have tried to remove the /etc/CODESYSControl_User.cfg [CmpUserMgr] but i could not find it and i was not sure if i should add it instead but i did not want to mess somthing up. I have tried to create a second gateway with the specific ip if the pi, that did not help. Could it be that i´m currently connected to the pi through WIFI? I can ping the pi and I can connect and control it through VNC. When i scan to select gateway target (scan edge gateway) i find 17-21 devices but can find the pi throug the mac adress. I started of trying to use the "CODESYS Control for Raspberry Pi SL" (I have a license sience earlier) as i read somewhere that this could be used on a Pi4 as well but now i´m trying with the MC SL, no changes, same problem. Right now - gateway version 4.8.0.0 (edgearmHF, armhf), Runtime Package 4.5.0.0 (raspberry, armhf). Any sugestions are very welcome! As mentioned above, theese are some of the things that i have tried/done - but i have been going at this for a while. Best, Martin
Last updated: 2023-09-10

Post by jzhvymetal77 on IecVarAccessLibrary.IBaseTreeNode methon CODESYS Forge talk (Post)
I had this code working in a previous version of CoDeSys to read variables from a GVL that were added to the Symbol configuration. The problem now is that when I get the _IBaseTreeNode_Parent, it returns a valid interface, but none of the methods or properties work. If you monitor the _IBaseTreeNode in the watch window, it does show the correct child count. However, it fails at step 30, where the child count incorrectly returns zero. In the image, you can see that the watch window displays the correct value that the property should return. Attached is the full project code. FUNCTION_BLOCK Symbols_TO_STR VAR_INPUT i_sPath : STRING(255); i_diIndexChild : DINT; i_diIndexComponent : DINT; END_VAR VAR_OUTPUT q_diChildCount : DINT; q_diComponentCount : DINT; q_sName : STRING(255); q_sValue : STRING(255); q_sType : STRING(80); q_sErrorResult : STRING(80); END_VAR VAR uiStepCopy : UINT; uiStep : UINT; uiStepProcessCopy : UINT; uiStepProcess : UINT; _IBase : IecVarAccessLibrary.IBase; _pIIecVarAccess5 : POINTER TO IecVarAccessLibrary.IIecVarAccess5; _IIecVarAccess5 : IecVarAccessLibrary.IIecVarAccess5; _RTS_IEC_RESULT : IecVarAccessLibrary.RTS_IEC_RESULT; _udiResult : UDINT; _VariableInformationStruct : IecVarAccessLibrary.VariableInformationStruct; _IBaseTreeNode_Parent : IecVarAccessLibrary.IBaseTreeNode; _IBaseTreeNode_Child : IecVarAccessLibrary.IBaseTreeNode; _ITypeDesc_Child : IecVarAccessLibrary.ITypeDesc; _TypeDescAsUnion_Child : IecVarAccessLibrary.TypeDescAsUnion; _arIBaseTreeNode_Child : ARRAY[0..20] OF IecVarAccessLibrary.IBaseTreeNode; _TypeClass_Child : IecVarAccessLibrary.IBaseLibrary.TypeClass; _psSymbolName_Child : POINTER TO STRING; _sSymbolName_Child : STRING(255); _IBaseTreeNode_Component : REFERENCE TO IecVarAccessLibrary.IBaseTreeNode; _TypeClass_Component : IecVarAccessLibrary.IBaseLibrary.TypeClass; _ByteAddress_Component : __XWORD; _ByteOffset_Component : __XWORD; _sArrayIndexName_Component : STRING(20); _diArrayIndexCalc_Component : DINT; _diArrayIndexValue_Component: DINT; _psSymbolName_Component : POINTER TO STRING; _sSymbolName_Component : STRING(255); END_VAR uiStepCopy:=uiStep; uiStepProcessCopy:=uiStepProcess; CASE uiStep OF 10: // GET IBASE FROM CURRENT APP _IBase:= IecVarAccessLibrary.IecVarAccGetFirstInterface2(0); IF _IBase<>0 THEN uiStep:=20; ELSE q_sErrorResult:=CONCAT(UINT_TO_STRING(uiStep), ': IecVarAccGetFirstInterface2'); uiStep:=9000; END_IF 20: //QueryInterface IIecVarAccess5 from IBASE _pIIecVarAccess5 := _IBase.QueryInterface(IecVarAccessLibrary.ITFID_IIecVarAccess5, ADR(_RTS_IEC_RESULT)); IF _pIIecVarAccess5<>0 AND _RTS_IEC_RESULT=0 THEN _IIecVarAccess5 := _pIIecVarAccess5^; uiStep:=30; ELSE q_sErrorResult:=CONCAT(UINT_TO_STRING(uiStep), ': QueryInterface_IIecVarAccess5'); uiStep:=9000; END_IF 30: // Get IBaseTreeNode_Parent _IBaseTreeNode_Parent := _IIecVarAccess5.VarAccGetNode3(ADR(i_sPath), ADR(_VariableInformationStruct), ADR(_RTS_IEC_RESULT)); IF _IBaseTreeNode_Parent<>0 AND _RTS_IEC_RESULT=0 THEN q_diChildCount:=_IBaseTreeNode_Parent.ChildCount; uiStep:=40; ELSE q_sErrorResult:=CONCAT(UINT_TO_STRING(uiStep), ': IBaseTreeNode_Parent'); uiStep:=9000; END_IF 40: // Get IBaseTreeNod_Child IF(q_diChildCount-1>=i_diIndexChild AND i_diIndexChild >=0) THEN _IBaseTreeNode_Child := _IBaseTreeNode_Parent.GetChild(i_diIndexChild); IF _IBaseTreeNode_Child<>0 THEN uiStep:=50; ELSE q_sErrorResult:=CONCAT(UINT_TO_STRING(uiStep), ': IBaseTreeNode_Parent'); uiStep:=9000; END_IF ELSE q_sErrorResult:=CONCAT(UINT_TO_STRING(uiStep), ': i_diIndexChild OutBounds'); uiStep:=9000; END_IF
Last updated: 2025-08-20

Post by jackbrady on Function Blocks and arrays of function blocks CODESYS Forge talk (Post)
Hello, I am new to Codesys and PLC programming in general (please go easy ha!) I'm not looking for code to be written for me just some help and pointing in the right direction. I am writing some code to send commands to a relay based on input values (to put it simply). Quite basic stuff. I have wrote a function block that takes a global variable (Open_command:BOOL) and outputs to another global variable (Opened : BOOL). The function block is simulating a device so I'll eventually get the globals from that. I now need to create multiple versions of this function block/ device (lets say 100) but I need each iteration of that function block to reference it's own relevant global variable. I think that the best way of doing this would be to use arrays, although I could be wrong. I am aware that for up to 100 instances I could very well manually assign everything but that seems rather time consuming and I want a fancier way of doing it. Here is a very basic example of what I am looking to do, please note I have not written this in proper code it's just to show what I mean. Global Variables V[0-100] int Open_command [0-100] Bool Opened [0-100] Bool Function Block var input x : BOOL Var output y : BOOL if x then y = TRUE ELSE y = FALSE The input to my function block will be Open_command, output will be Opened Example code. If V[x] > 10 then Open_command [x] = TRUE ELSE Open_command [x] = FALSE (So when V1 goes above 10 I need Open_command1 = TRUE therefore initiating FB1 output. V2 > 10, open_command2 = True > FB2 output V3 > 10, open_command3 = True > FB3 output ... ... ) What I can't seem to figure out is how to tie all this together, I have read through the codesys documentation and if anything it has confused me more! ha. Apologies for the poorly written post but hopefully you understand what I am trying to get at. Thanks, Jack
Last updated: 2024-02-14

<< < 1 .. 87 88 89 90 91 .. 96 > >> (Page 89 of 96)