codesys3 data logger
CODESYS Forge
talk
(Thread)
codesys3 data logger
Last updated: 2023-02-01
String Data Logger
CODESYS Forge
talk
(Thread)
String Data Logger
Last updated: 2021-12-14
codesys - array, data logger
CODESYS Forge
talk
(Thread)
codesys - array, data logger
Last updated: 2022-07-19
csv data logger stops working after 30 minutes
CODESYS Forge
talk
(Thread)
csv data logger stops working after 30 minutes
Last updated: 2022-08-17
CoDeSys - Logger
CODESYS Forge
talk
(Thread)
CoDeSys - Logger
Last updated: 2010-02-23
Logger in ms
CODESYS Forge
talk
(Thread)
Logger in ms
Last updated: 2024-03-16
Post by francescoc on Logger in ms
CODESYS Forge
talk
(Post)
Hi, I cannot find any documentation regarding the codesys configuration file. I modified this part to have log files saved to disk: [CmpLog] Logger.0.Name=LOGS/PlcLog Logger.0.Filter=0xFFFFFFFF Logger.0.Enable=1 Logger.0.MaxEntries=20000 Logger.0.MaxFileSize=5000 Logger.0.MaxFiles=10 Logger.0.Backend.0.ClassId=0x0000010B ;sends logger messages to SysOut Logger.0.Backend.1.ClassId=0x00000104 ;writes logger messages in a file Logger.0.Backend.2.ClassId=0x00000135 ;sends logger messages as UDP syslog Logger.0.Type=0x314;Set the timestamp to RTC ;Logger.1.Name=/tmp/CommLog ;Logger.1.Enable=1 I need to have milliseconds in the timestamp as well. What value should I use instead of 0x314? Is there any documentation regarding this file? Thank you
Last updated: 2024-03-16
Post by eschwellinger on Edge Gateway online, but PLC is not online
CODESYS Forge
talk
(Post)
we need some logfiles from the edge gateway /etc/Gateway.cfg [CmpLog] CmpEdgeGateway.Filter=0xFFFFFFFF Logger.0.Name=/tmp/codesysedge.log Logger.0.Filter=0x0000000F Logger.0.Enable=1 Logger.0.MaxEntries=100000 Logger.0.MaxFileSize=5000000 Logger.0.MaxFiles=1 Logger.0.Backend.0.ClassId=0x00000104 ;writes logger messages in a file Logger.0.Type=0x314 ;Set the timestamp to RTC and does the scan via Automation Server show the plc?
Last updated: 2024-01-09
Post by felipemsgarcia on Edge Gateway online, but PLC is not online
CODESYS Forge
talk
(Post)
Hi Edwin, The PLC is already in the automation server so nothing happens when I scan the network, however the PLC show offline (not connected). Please see logs below. [CmpLog] Logger.0.Name=codesysedge.log Logger.0.Filter=0x0000000F Logger.0.Enable=1 Logger.0.MaxEntries=100000 Logger.0.MaxFileSize=1000000 Logger.0.MaxFiles=1 Logger.0.Backend.0.ClassId=0x00000104 ;writes logger messages in a file Logger.0.Type=0x314 ;Set the timestamp to RTC Thank you!
Last updated: 2024-01-09
Saving UINT data collected as String data to MMC
CODESYS Forge
talk
(Thread)
Saving UINT data collected as String data to MMC
Last updated: 2007-08-17
Data Source Manager with CODESYS Symbolic data source
CODESYS Forge
talk
(Thread)
Data Source Manager with CODESYS Symbolic data source
Last updated: 2021-03-23
Post by solve-it on SysFileOpenAsync
CODESYS Forge
talk
(Post)
Just realized that it is the /dev/input/js0 file. Don't think this is a prob either. Found the ConfigFile. Where and how to add /dev/input/js0? raspberry [SysFile] FilePath.1=/etc/, 3S.dat PlcLogicPrefix=1 [SysTarget] TargetVersionMask=0 TargetVersionCompatibilityMask=0xFFFF0000 [CmpLog] Logger.0.Name=/tmp/codesyscontrol.log Logger.0.Filter=0x0000000F Logger.0.Enable=1 Logger.0.MaxEntries=1000 Logger.0.MaxFileSize=1000000 Logger.0.MaxFiles=1 Logger.0.Backend.0.ClassId=0x00000104 ;writes logger messages in a file Logger.0.Type=0x314 ;Set the timestamp to RTC [CmpSettings] FileReference.0=SysFileMap.cfg, SysFileMap FileReference.1=/etc/CODESYSControl_User.cfg [SysExcept] Linux.DisableFpuOverflowException=1 Linux.DisableFpuUnderflowException=1 Linux.DisableFpuInvalidOperationException=1 [CmpWebServer] ConnectionType=0 [CmpOpenSSL] WebServer.Cert=server.cer WebServer.PrivateKey=server.key WebServer.CipherList=HIGH [SysMem] Linux.Memlock=0 [CmpCodeMeter] InitLicenseFile.0=3SLicense.wbb [SysEthernet] Linux.ProtocolFilter=3 [CmpSchedule] ProcessorLoad.Enable=1 ProcessorLoad.Maximum=95 ProcessorLoad.Interval=5000 DisableOmittedCycleWatchdog=1 [CmpUserMgr] AsymmetricAuthKey=6873d655ac1f166f3743feea42d2f3dd1b39ae40 [CmpSecureChannel] CertificateHash=09fd8d52be4ddd45a709bc9c95e2aa093b3f5695 [SysSocket] Adapter.0.Name="eth0" Adapter.0.EnableSetIpMask=1 ;raspberry [ComponentManager] ;Component.1=CmpGateway ;Component.2=CmpGwCommDrvTcp ;Component.3=CmpGwCommDrvShm [SysCom] ;Linux.Devicefile=/dev/ttyS [CmpBlkDrvCom] ;Com.0.Name=MyCom ;Com.0.Baudrate=115200 ;Com.0.Port=3 ;Com.0.EnableAutoAddressing=1 [SysProcess] Command.0=shutdown [CmpApp] Bootproject.RetainMismatch.Init=1 ;Application.1=Application ;Application.1=Application ;Application.1=Application Application.1=Application [CmpRasPi] Architecture=armv6l [CmpRedundancyConnectionIP] [CmpRedundancy] [CmpSrv] [IoDrvEtherCAT]
Last updated: 2024-07-16
Post by eschwellinger on The application does not exist on "device"
CODESYS Forge
talk
(Post)
please check the plc logger for more details
Last updated: 2024-12-17
Data consistency between tasks
CODESYS Forge
talk
(Thread)
Data consistency between tasks
Last updated: 2013-12-27
General Data Transmission
CODESYS Forge
talk
(Thread)
General Data Transmission
Last updated: 2012-08-05
Retentive data
CODESYS Forge
talk
(Thread)
Retentive data
Last updated: 2019-11-08
Data Conversion
CODESYS Forge
talk
(Thread)
Data Conversion
Last updated: 2012-08-20
Trend data format
CODESYS Forge
talk
(Thread)
Trend data format
Last updated: 2011-11-01
Data conversion
CODESYS Forge
talk
(Thread)
Data conversion
Last updated: 2020-11-19
UXINT Pseudo data type
CODESYS Forge
talk
(Thread)
UXINT Pseudo data type
Last updated: 2021-05-26
Saving application data
CODESYS Forge
talk
(Thread)
Saving application data
Last updated: 2017-09-01
Saving data in powerfail
CODESYS Forge
talk
(Thread)
Saving data in powerfail
Last updated: 2021-11-10
RFID data filtering
CODESYS Forge
talk
(Thread)
RFID data filtering
Last updated: 2015-08-03
Test Manager Data Passing
CODESYS Forge
talk
(Thread)
Test Manager Data Passing
Last updated: 2013-10-30
Any data type
CODESYS Forge
talk
(Thread)
Any data type
Last updated: 2019-03-21
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND
or OR
.