cmpTraceMgr - store trace for later loading.
CODESYS Forge
talk
(Thread)
cmpTraceMgr - store trace for later loading.
Last updated: 2020-06-22
Best way to save data for later analysis!
CODESYS Forge
talk
(Thread)
Best way to save data for later analysis!
Last updated: 2015-06-22
Post by codesysdave on Using globals without a prefix (bMyTag vs GVL.bMyTag)
CODESYS Forge
talk
(Post)
Over 5 years later, you helped me tremendously. Thanks. And great kitty picture.
Last updated: 2024-06-04
Post by dkugler on Calculate Time Between Two Events Using RTC
CODESYS Forge
talk
(Post)
a few seconds later with google search... https://stackoverflow.com/a/61986234 SYS_TIME is definitely an ABB AC500 specific function, included in library SysInt_AC500_V10.lib.
Last updated: 2024-08-14
Post by ulad on SPI Communication
CODESYS Forge
talk
(Post)
Hello. I created a project that uses SPI. This project is working well. I can see with an oscilloscope that the SPI pins are actually changing. But when I resave this project in the IDE and open it later in the system, I see a constant error. What do I need to fix? What am I doing wrong? Thank you.
Last updated: 2023-12-23
Post by dav3 on Exception auf Raspberry, CMCommCycleTask Tainted
CODESYS Forge
talk
(Post)
Hello, I don't really know what my problem was, but it's working for me at the moment. All i did was to change my code because of some REAL_TO_INT conversions, like i wrote above. And later a complete new Pi setup (because of 64x support with 4.10.0.0 now).
Last updated: 2024-02-16
Post by durstloescher on Library Documentation DocScripting
CODESYS Forge
talk
(Post)
Hi, I am currently creating a documentation for our library with DocScripting. In the process, I noticed that Visu images are created before the merge and transform, i.e. "screenshots" of the different Visus. Unfortunately, these are not used in the later process (Merge/Transform). Is there a way to set it up so that they are found in the html file?
Last updated: 2024-02-19
Post by lbartik on MPC predictive control
CODESYS Forge
talk
(Post)
Would this work? https://www.mathworks.com/hardware-support/codesys.html I'm also interested in real-world MPC and have no idea where to start. There is an exciting Python library that is also beyond my grasp: https://www.do-mpc.com/en/latest/index.html Step 1, get PhD(s). Step 2, get job in aerospace/robotics. Step 3, return 15 years later to share this knowledge?
Last updated: 2024-10-19
Post by mozed on Connection to device closed
CODESYS Forge
talk
(Post)
Hello, Exulting the command /opt/CoDeSysControl/Files/run restart debug I get this response from the linux terminal:(ScreenShot1 to ScreenShot7) When I try to reconnect via codesys this line appears at the linux terminal level:(ScreenShot8) A few seconds later, the error window appears on Codesys.(ScreenShot9) I see that following the command /opt/CoDeSysControl/Files/run restart debug there are errors, are they the problem? Sincerely,
Last updated: 2023-08-24
Post by sachem on SysFileGetTime problem
CODESYS Forge
talk
(Post)
Good morning. I'm working with a Weidmuller controller using Codesys. My project use OPC-UA to communicate an application in my pc with the controller. Yesterday, I installed the license of the controller and test it, and the communication works perfect. I use the communication with anonymous login, and works fine. But, hours later, the anonymous login don't work, and the controller only allows connection via OPC with username and password. Someone know why this happend? Thanks
Last updated: 2024-04-09
Post by mozed on Connection to device closed
CODESYS Forge
talk
(Post)
Hello I am using an OpusA3 with version 3.5 SP17 Patch 3 as part of a project. I had no real problem before I encountered a problem that blocked me. The detection of the OpusA3 from Codesys is done correctly. The gateway is well configured and if I ping the gateway or the OpusA3 I receive the response correctly. The problem is that when I try to connect, the Opus screen freezes and a few moments later Codesys displays an error message ("connection to device closed"). I tried to change PC, to update the runtime, to change OpusA3 but the problem remains the same. I'm a little lost knowing that before it worked without problem. I went back to a previous version of the project (where it worked correctly) but the message still appears. Do you have any clues to solve the problem? Sincerely,
Last updated: 2023-08-23
Post by muhq on Profinet connection to Siemens CP343-1 Lean (IO-Device/Slave)
CODESYS Forge
talk
(Post)
Hi, I am quite new to Codesys and I try to do a Profinet connection to an Siemens PLC (315-2DP) with CP343-1 Lean Modul. I already configured the Siemens PLC, exported the GSDML. Then I added a new project in Codesys, added following moduls: - Ethernet - PN_Controller - Imported Profinet Device via GSDML importer When I start the programm everything looks fine but I always get the message "Stopped Profinet" and no data is available This is only for a small test. Therefore I start to do that on a Windows 10 with Development System. Later I will try to realize this on Raspberry. Ethernet Adapter is configured (192.168.1.1 / 24) Firewall deactivated WinPCap is installed S7-Station seems to be found ('fuadazenzitest') Can please somebody help me?
Last updated: 2023-08-26
Post by tomgr on Codesys 3.5.19 Control Win x64 - network adapter for EtherCAT master not working
CODESYS Forge
talk
(Post)
Hi guys I am trying to run on my laptop Codesys 3.5.19 Control Win x64 where I created a EtherCAT master. I have defined the controler, specified network adapter (my docking station) and everything worked as expected. Later I needed to test it on site (without docking station) so I changed the network adapter by EC master to my laptop network card. After that it shows "Network adapter opened" but no device can be found by scanning and in LOG is saying "SysEthernet: packet could not be sent, error code: -1". Same error with USB network card, but if I switch back to docking station, all is working again... Any idea what I'm doing wrong?
Last updated: 2023-11-22
Post by jegerjon on Testing of Codesys program
CODESYS Forge
talk
(Post)
I have a simulation function that toggle xSimActive. I map all IO variables to "IO GVLs" when xSimActive=0. I map IO corresponding SimIO GVL to "IO GVLs" when xSimActive=1. Then I write code for the simulation program that runs when xSimActive=1. Typically increase flow corresponding to pump speed, simulate tankfilling corresponding to flow and so on. I made a FC that require a correct code to activate simulation to avoid unintended activation by service dept. When comissioned remove any possibility to activate simulation. Super when officetesting and supporting service dept. + cheap as it requires no additional equipment, and it is easier to support customer later on in the life cycle as you can test proposed changes without setting up a testlab.
Last updated: 2023-12-07
Post by jegerjon on Testing of Codesys program
CODESYS Forge
talk
(Post)
I have a simulation function that toggle xSimActive. I map all IO variables to "IO GVLs" when xSimActive=0. I map IO corresponding SimIO GVL to "IO GVLs" when xSimActive=1. Then I write code for the simulation program that runs when xSimActive=1. Typically increase flow corresponding to pump speed, simulate tankfilling corresponding to flow and so on. I made a FC that require a correct code to activate simulation to avoid unintended activation by service dept. When comissioned remove any possibility to activate simulation. Super when officetesting and supporting service dept. + cheap as it requires no additional equipment, and it is easier to support customer later on in the life cycle as you can test proposed changes without setting up a testlab.
Last updated: 2023-12-07
Post by yang123 on EtherCAT Can't reconnect to servo drive
CODESYS Forge
talk
(Post)
I am using Ethercat Master 4.6.0.0 and have use the automatic restart slaves feature. But we found of after the Ethercat communication normal and slave drive power-off and power-on the slave can't reconnect sucess. The PLC Log show the drive was al status "6#34 : Invalid DC Timeout Error" and its was reconnection sucess first but seconced later the drive will show the "16#2C : Fatal Sync error" and then drive will can't reconnection. Other slave are reconnect sucess which was link after the can't reconnect's drive the drive was OMRON R88D-1SN
Last updated: 2024-01-23
Post by timvh on CODESYS V3.5 SP15 Patch 2 won't open
CODESYS Forge
talk
(Post)
This is almost always related to previously working with an additonal monitor. If you have placed CODESYS on that monitor, later start your laptop again and open CODESYS without that monitor, then Windows still places it in the previous position, but then it is not visible. So the solution by cehermanstad can be used to move it to the main screen to make it visible again. PS, another way to move it, is by pressing SHIFT and then right-click on the icon in the task bar, then select move. You can then move it with the arrow keys or your mouse.
Last updated: 2024-02-27
Post by xabier on BUG CODESYS-NO WORK AUTOMATICALLY RESTARSLAVES
CODESYS Forge
talk
(Post)
I detect a Bug of Codesys....NO WORK AUTOMATICALLY RESTARSLAVES. I explain the secuence: I have click in my project the option AUTOMATICALLY RESTARSLAVES In the moment start my Ipc, the network ethercat start correctly I disconnect the wire of my first slave and later connect again the wire..(see the screen Bug Codesys restart slave1) NO work the restart automatic slaves...and is not possible execute of FB MC_REset beacuause appear this error (see the screen Bug Codesys restart slave2) The only way for resolver this problem is execute the FB SMC3ReinitDrive I replay the same with PLC BECKHOFF in Twincat3 and I havent this problem...In the moment connect the wire again in the slave the comunication of ehterCat restart and the slave comunication again with out problem
Last updated: 2024-11-07
Post by george32 on CSV file and string manipulation.
CODESYS Forge
talk
(Post)
Dear folks, I think I have a rather simple question but I could not find the right answer to my question: I have made with Excel a CSV file where I would like to have some general data regarding my program variables. I have made an program what let me read the file. The string I am currently get is at follows: 'IP_Adres;192.168.45.12$R$NPort_number;2000$R$NCycle_time;43$R$NStart_Standard_IO;20$R$N' Now I want to split the string in multiple part, which I later would connect to the right variable. By Google and experimenting I have reached to the following code for the first part of the splitting proces: // Splitting the BOM of the string: Received_string := FileReadString; IF LEFT(STR:=New_string,3)= '' THEN Received_string_without_BOM :=RIGHT(STR:= Received_string,SIZE:= (LEN(STR:= Received_string))-3); END_IF //Splitting the remaining string in part for later declaration. WHILE index = 0 DO index_split_part := FIND(STR1:= Received_string_without_BOM,STR2:= '$R$N'); Part_of_String[index]:=LEFT(STR:=Received_string_without_BOM, SIZE:= index_split_part); index := index + 1; END_WHILE However in the splitting proces I could not understand what is really happening. I understand that the Find() function returns the first value the $R$N in the Received_string_without_BOM. This would mean that the index_split_part := 23 I|P| _ |A |d|r|e|s|;|1_|9 |2 |. |1 |6 |8 |. |4 |5 |. |1 |2 |$ |R |$ |N |P | 1|2| 3 |4 |5|6|7|0|9|10|11|12|13|14|15|16|17|18|19|20|21|22|23|24|25|26|27| So the next part is to read the first 23 characters of the Received_string_without_BOM with the LEFT() function. I expected that the outcome the following was: 'IP_Adres;192.168.45.12$'. However the outcome is: 'IP_Adres;192.168.45.12$R'. I do not understand where the R after the $ sign comes from, because its place is 24 so it would not be added to the part_of the_string[index]. If I hard coded value 24 for the size it gives me the following return: 'IP_Adres;192.168.45.12$R$N'. I would expect everything till the R but the code adds the $N also to the string. I hope someone could explain to my what I am seeing wrong in my point of view? With kind regards, George
Last updated: 2024-09-27
Post by ryusoup on JSONByteArrayWriter problem?
CODESYS Forge
talk
(Post)
Hello, I am trying to implement a FB to make JSON formatted WSTRING type message using JSON Utilities 1.9.0.0 included in the IIoT library. In my case, I want to set some objects or arrays and set values to them later. But when I wrote as the sample below, // init builder builder(pJsonData:=pJsonData, diRootObj=>diRootObj); // set the 1st key to root diKey1 := builder.SetKeyWithArray(wsKey:="key1", diParentIndex:=diRootObj, eError=>eError); // set a value to the 1st key wsValue:="value01"; builder.SetValue(Value:=wsValue, diParentIndex:=diKey1, eError=>eError); // set the 2nd key to root diKey2 := builder.SetKeyWithArray(wsKey:="key2", diParentIndex:=diRootObj, eError=>eError); // set a value to the 2nd key wsValue:="value02"; builder.SetValue(Value:=wsValue, diParentIndex:=diKey2, eError=>eError); // set a value to the 1st key again wsValue:="value03"; builder.SetValue(Value:=wsValue, diParentIndex:=diKey1, eError=>eError); // set a value to the 2nd key again wsValue:="value04"; builder.SetValue(Value:=wsValue, diParentIndex:=diKey2, eError=>eError); // write build result writer(xExecute:=TRUE, pwData:=ADR(wsResult), udiSize:=SIZEOF(wsResult), xAsyncMode:=FALSE, jsonData:=pJsonData^); the result was: { "key1": ["value01"], "key2": ["value02", "value03", "value04"] } while my expection was: { "key1": ["value01", "value03"], "key2": ["value02", "value04"] } Inspecting pJsonData^, JSONData itself seems to be ok, so I believe the issue is something caused by the writer FB. Does anyone know how to fix it? Thanks,
Last updated: 2023-10-04
Post by acc00 on Main Task cycle too long leading to PLC Fail
CODESYS Forge
talk
(Post)
I have 2 Wago PFC200 PLC, running with Runtime SP19 Patch 5, with the Redundant application. The PLC communicates as Modbus Master with at this moment 15 Modbus Slaves -later there will be 28 in total- (Drives, Power management units,...). These devices are connected in 2 rings (1 ring of Drives, 1 ring of Power Management units), with 2 Managed Moxa Switches being part of the ring. Each PLC is connected to one of these switches. The issue I'm encountering is that the Cycle time of the Active PLC goes very high when I'm closing the Drive ring (simulating an issue on one Cabinet supply, resulting in that one Drive shut down, which can happen on field quite often). As a result of this long cycle, the PLC fails and goes to Exception, and the Passive PLC does not take control of the system. A normal cycle is around 30ms for the Main task, and a few ms for the Ethercat task. When I monitor with Profiler, I see that in this Maximum Cycle, the main Task is only taking 13ms, so I'm not sure where the PLC is hanging for so long. Is the remaining cycle time the Redundant management/sync or something else? Thank you in advance.
Last updated: 2024-03-08
Post by reinier-geers on License problem gateway
CODESYS Forge
talk
(Post)
The hole setup is made by 3s. So its a comination of one not two. If Epis decide not to support extra licence whats then the funtion of providing an option with a single license ?? So the idee by 3s has a flod. Epis change the system to add the Stick. I send controller inc stick to Epis. On my software i can see the stick. An then you tel me i need a other license to use an license ?? Makes completly no sense. Codesys should be flexible but is not. I tried Delta. But has no HMI and has its own Codesys ?? Why ?? Then i tried Crist. The block there own system by a password. But dont know the password and cant switch it off. At the end the want me to pay for support to solve ther own made problem. So i send it al back. The extra license is adviced by 3s . Now a few month later still no working solution.
Last updated: 2024-05-01
Post by bjarne-pagaard on Communication between applications on same device/controller/runtime (Win RTE 3.5.20.20)
CODESYS Forge
talk
(Post)
Thanks for this - I have now been looking in to just having an extra (non-RTE) runtime on the same machine, as you suggest. I will probably proceed this way. Even though it still seems very odd to me, that variable exchange to a different runtime is easier than between applications on the same controller. There will be some fun with the licensing, it seems. Does anyone know if it is possible to specify which license container/specific license the runtime is going to use at runtime. Let's say I have two available licenses with different resources available, for example one license allows multicore and multiple EtherCAT channels, but not many visu tags (for the RTE). Another with less resources but a lot of visu tags (for the Visu controller). Let's say the program in one of the controllers could be fully licensed by either of the two available licenses, but picks the 'largest' first. A bit later, the larger application starts, but is left with the smaller license.. How can I make sure that the 2 runtimes select the right license at startup?
Last updated: 2024-10-01
Post by mainak on Opaque NodeId in the OPC UA server
CODESYS Forge
talk
(Post)
Hello all, I am using the OPC UA server with my custom information model. I have used the communication manager to add my information model under my application and created instances from OPC UA types. I see that the created instances in the OPC UA server has some opaque nodeid (attached screenshot) and I want to change that. Therefore I have the following questions: 1. Is there a way to configure the NodeIds of instances in the OPC UA server? I tried to edit it using the UaExpert client but got error "BadNotWriteable". is it possible to configure it somewhere so that the nodeids can be changed using an external client? 2. Is there a way to define the rule for creating instance nodeids within the codesys IDE? 3. Is it possible to create the instances before e.g. using a modelling tool like UaModeler and import them as part of the information model and use them later? Using the communication manager, I can only create instances from types. I couldn't find a way to map my existing instances to plc tags from my application. It would be nice if someone could help me with these issues. Thanks in advance. :)
Last updated: 2024-10-19
Post by koerbejm on Probleme beim aktivieren von Lizenzen
CODESYS Forge
talk
(Post)
Liebe Codesys-Gemeinde, ich habe folgendes Problem und bitte um Hilfe: Um eine auf meinem dem Raspberry Pi laufende Steuerung ohne große Mühe duplizieren zu können, habe ich mir ein Image der SD Karte mit Win32 Diskimager erstellt. Dieses konnte ich bisher ohne weitere Probleme auf eine weitere Micro-SD karte ausrollen. Anschließend habe ich mich via Putty auf den PI geschaltet, die vorherige Lizenz (die ja für den vorheringen PI zulässig war) gelöscht über - sudo su - rm -r /var/opt/codesys/cmact_licenses/ - reboot Um dann via Codesys 3.5 SP16 Patch 4 eine neue Lizenznummer ">>Tools>Lizenzmanager>Lizenz aktivieren" zu aktivieren und das wars. Durch die Umstellung des Lizensierungsverfahrens klappt diese Variante nun nicht mehr. Ich habe mir neue Lizenzen von Codesys gekauf, doch sobald ich diese in die Ticket-ID eintrage und aktivieren möchte bekomme ich folgende Fehlermeldung: ReturnCode: 403046401, An internal error has occured. Please try it again later. (siehe Bild im Anhang "Fehler_Codesys3.5V16.png") Ich habe dann meine Codesys-Version auf Version 3.5 SP20 geupdated und das selbe versucht mit dem Resultat, dass ich nun folgende Fehlermeldung erhalte: "Der ausgewählte Container "...." paßt nicht zu Ihrem Ticket. Bitte wählen Sie einen passenden aus." --> Siehe Bild im Anhang "Fehler_Codesys3.5V120.png" Was genau kann/muss ich tun, damit ich einfach wie bisher meine Steuerungen duplizieren kann? Verwendete Hardware: Raspberry Pi 3 Model B+ Verwendete Lizenz: Codesys Control Basic L Viele Grüße und Danke, Jan
Last updated: 2024-10-23
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND
or OR
.