Post by jari-koivuluoma on Problem trying Net Base Services 3.5.15.0 TCP connection
CODESYS Forge
talk
(Post)
I have a need to send messages between 2 PLCs and I cant use network variables (because of size limit) so I tried writing this simple test program. This seems to work fine. I can send messages back and forth when a first "Start server" and then "Connect client". See the attached image. However, if I disconnect the client by setting ClientConnect to false and try to re-connect then the TCP_Client just gives me TIMEOUT error. When I stop and start the server again, then Im able to reconnect. How is this supposed to work? Why reconnecting wont work. There is not other way of disconnecting the client than setting xEnable of the TCP_Client to false. This is just a testing program and I will try it on 2 seperate devices once this works. PROGRAM PLC_PRG VAR CONSTANT mySize : UDINT := 255; END_VAR VAR Server: NBS.TCP_Server; ServerIpStr: STRING := '127.0.0.1'; ServerIP: NBS.IP_ADDR; ServerPort: UINT := 50000; ServerConnection: NBS.TCP_Connection; Client: NBS.TCP_Client; ServerRead: NBS.TCP_Read; ServerWrite: NBS.TCP_Write; ServerSend: STRING(mySize); ServerReceive: STRING(mySize); ServerConnect: BOOL; bServerSend: BOOL; IP: NBS.INADDR; ConnectedClientIP: STRING; ClientPort: UINT := 50000; ClientIpStr: STRING := '192.168.1.49'; ClientIP: NBS.IP_ADDR; ClientRead: NBS.TCP_Read; ClientWrite: NBS.TCP_Write; ClientSend: STRING(mySize); ClientReceive: STRING(mySize); ClientConnect: BOOL; bClientSend: BOOL; Error: BOOL; Message: BOOL; END_VAR // Server ServerIP.sAddr := ServerIpStr; Server( ipAddr := ServerIP, uiPort := ServerPort ); ServerConnection( xEnable := Server.xEnable, hServer := Server.hServer, ); IP := ServerConnection.IPAddress; ConnectedClientIP := F_Concat7( BYTE_TO_STRING(IP.S_un_b.s_b1),'.', BYTE_TO_STRING(IP.S_un_b.s_b2),'.', BYTE_TO_STRING(IP.S_un_b.s_b3),'.', BYTE_TO_STRING(IP.S_un_b.s_b4)); ServerRead( xEnable := ServerConnection.xActive, hConnection := ServerConnection.hConnection, szSize := SIZEOF(ServerReceive), pData := ADR(ServerReceive) ); IF ServerRead.xReady AND ServerRead.szCount > 0 THEN Message := TRUE; END_IF IF ServerRead.eError > 0 THEN Error := TRUE; END_IF ServerWrite( xExecute := ServerConnection.xActive AND bServerSend, hConnection := ServerConnection.hConnection, szSize := LEN(ServerSend)+1, pData := ADR(ServerSend) ); IF ServerWrite.xDone THEN bServerSend := FALSE; END_IF IF ServerWrite.eError > 0 THEN Error := TRUE; END_IF // Client ClientIP.sAddr := ClientIpStr; Client( xEnable := ClientConnect, ipAddr := ClientIP, uiPort := ServerPort, udiTimeOut := 10000000 ); ClientRead( xEnable := Client.xActive, hConnection := Client.hConnection, szSize := SIZEOF(ClientReceive), pData := ADR(ClientReceive) ); IF ClientRead.xReady AND ClientRead.szCount > 0 THEN Message := TRUE; END_IF IF ClientRead.eError > 0 THEN Error := TRUE; END_IF ClientWrite( xExecute := Client.xActive AND bClientSend, hConnection := Client.hConnection, szSize := LEN(ClientSend)+1, pData := ADR(ClientSend) ); IF ClientWrite.xDone THEN bClientSend := FALSE; END_IF IF ClientWrite.eError > 0 THEN Error := TRUE; END_IF
Last updated: 2024-10-03
Post by wollvieh on Display minutes as hours & minutes
CODESYS Forge
talk
(Post)
Here a code for an Operation Counter with : days,hours,minutes,seconds as an example, maybe it points you the right direction ? FUNCTION_BLOCK OperationDayHour VAR_INPUT IN : BOOL; // Betrieb Takt : BOOL; // 1Hz Systemtakt END_VAR VAR_OUTPUT BetrTag : UDINT; // Ausgabe Betriebstage Betrstd : UDINT; // Ausgabe Betriebsstunden Betrmin : UDINT; // Ausgabe Betriebsminuten Betrsec : UDINT; // Ausgabe Betriebsekunden BetrString : STRING; // Ausgabe als String END_VAR VAR ///Erkennung Taktflanke Flanke: R_TRIG; END_VAR VAR_IN_OUT BetrsecAbsolut: UDINT; //Ein/Ausgangsvariable Betriebssekunden RETAIN !!! END_VAR Flanke(CLK:= Takt, Q=> ); (*Erkennung Taktflanke*) IF (IN AND Flanke.Q) THEN (*Sekunden hochzΓ€hlen*) BetrsecAbsolut := BetrsecAbsolut + 1; END_IF Betrsec := BetrsecAbsolut MOD 60; Betrmin := ( BetrsecAbsolut / 60) MOD 60; Betrstd := ( BetrsecAbsolut / 60 / 60 ) MOD 24; BetrTag := ( BetrsecAbsolut / 60 / 60 /24 ); BetrString := RIGHT ( UDINT_TO_STRING( BetrTag + 100000),5); BetrString := CONCAT (BetrString, 'd_'); BetrString := CONCAT (BetrString,RIGHT ( UDINT_TO_STRING( Betrstd + 100000),5)); BetrString := CONCAT (BetrString, 'h_'); BetrString := CONCAT (BetrString, RIGHT ( UDINT_TO_STRING( Betrmin + 100),2)); BetrString := CONCAT (BetrString, 'm_'); BetrString := CONCAT (BetrString, RIGHT ( UDINT_TO_STRING( Betrsec + 100),2)); BetrString := CONCAT (BetrString, 's');
Last updated: 2024-05-27
How to use matlab to send parameters to codesys
CODESYS Forge
talk
(Thread)
How to use matlab to send parameters to codesys
Last updated: 2018-10-10
VAR_IN_OUT, POINTER TO and REFERENCE TO
CODESYS Forge
talk
(Thread)
VAR_IN_OUT, POINTER TO and REFERENCE TO
Last updated: 2021-11-16
Unable to connect to this device
CODESYS Forge
talk
(Thread)
Unable to connect to this device
Last updated: 2024-06-28
Post by gustavocsw on MQTT memory leak problem
CODESYS Forge
talk
(Post)
Hello everyone, I'm using the IoT Library to implement the MQTT communication with my local broker server in order to publish and subscribe at specifics topics to share and consume information about my application. But, it seems that are occurring some memory leak problem in a "high" frequency (more than 10 Hz) subscribe process. I follow the same method as in IoT Lib exemples, and at first looks perfect but my PLC was rebooting frequently and when I check its memory usage that was increasing as fast as the subscribe massage was sent. I'm using a WEG PLC410 and a WEG PLC500, and this error occurred in both of them (including in CODESYS Control Win x64). The application sends to the system a message JSON with the float payload Ex. {"data" : 0.8500}, but this happens with a INT, or BOL as well. I use the follow code in my application to find the value: //FindFirstValueByKey VARs PROGRAM JSON_VELO VAR //------Setting the JSON Subscriber to Set the Relay Value jsonDataVelo : JSON.JSONData; jsonByteArrayReaderVelo : JSON.JSONByteArrayReader; xST1okVelo : BOOL; FindFirstValueByKeyVelo : JSON.FindFirstValueByKey; jsonElementVelo : JSON.JSONElement; xDoneReaderVelo : BOOL; xDoneFindVelo : BOOL; //STRING and WSTRING for Subscribe the massage sPayloadJsonVelo : STRING := 'opa'; psPayloadJsonVelo : POINTER TO BYTE := ADR(sPayloadJsonVelo); //wsPayloadJsonRelaySet : WSTRING := "opa"; wsPayloadJsonVelo : WSTRING := STRING_TO_WSTRING('opa'); pwsPayloadJsonVelo : POINTER TO WORD := ADR(wsPayloadJsonVelo); lrVelo : LREAL; xKeepAliveVelo : BOOL; xSetVelo : BOOL; RSSet : RS; LIMPAR : STRING; //Find the msg end sFindVelo : STRING := '}'; psFindVelo : POINTER TO STRING := ADR(sFindVelo); iLenVelo : INT; iSizeVelo : INT := 12; udiContMsg : UDINT; END_VAR // FindFirstValueByKey CODE // Relay Set configuration xSetVelo := MQTT_SUBSCRIBER.RSVelo.Q1; IF xSetVelo THEN xKeepAliveVelo := TRUE; END_IF IF xKeepAliveVelo THEN udiContMsg := udiContMsg + 1; iLenVelo := TO_INT(StrLenA(psPayloadJsonVelo)); iSizeVelo := iLenVelo - TO_INT(MQTT_SUBSCRIBER.udiPayloadSizeVelo); StrDeleteA(psPayloadJsonVelo,iSizeVelo,iLenVelo); wsPayloadJsonVelo := STRING_TO_WSTRING(sPayloadJsonVelo); pwsPayloadJsonVelo := ADR(wsPayloadJsonVelo); //MQTT.ConvertUTF8toUTF16(sourceStart:= ADR(sPayloadJsonVelo), targetStart:= ADR(wsPayloadJsonVelo), dwTargetBufferSize:= TAM, bStrictConversion:= 1); //Reset jsonByteArrayReader jsonByteArrayReaderVelo ( xExecute := TRUE, pwData := pwsPayloadJsonVelo, jsonData := jsonDataVelo, xDone => xDoneReaderVelo ); FindFirstValueByKeyVelo( xExecute := xDoneReaderVelo, wsKey := "data", diStartIndex:= 0, jsonData := jsonDataVelo, jsonElement => jsonElementVelo, xDone => xDoneFindVelo ); IF xDoneFindVelo THEN lrVelo := jsonElementVelo.value.lrValue; //Reset jsonByteArrayReader jsonByteArrayReaderVelo ( xExecute := FALSE, pwData := pwsPayloadJsonVelo, jsonData := jsonDataVelo, xDone => xDoneReaderVelo ); FindFirstValueByKeyVelo( xExecute := FALSE, wsKey := "data", diStartIndex:= 1, jsonData := jsonDataVelo, jsonElement => jsonElementVelo, xDone => xDoneFindVelo ); xKeepAliveVelo := FALSE; GVL.xSetVeloRead := TRUE; END_IF END_IF And this to subscribe at the topic: //SUBSCRIBE VAR: //----------------- Subscribe Velocity ----------------------- MQTTSubscribeVelo : MQTT.MQTTSubscribe;//Variable MQTTSubscriber block -X - function-X wsTopicSubscribeVelo : WSTRING(1024) := "CORE/odometry/GET/data/simp"; // Topic to publish a message sSubscribeMassageVelo : STRING; udiPayloadSizeVelo : UDINT; xSDoneVelo : BOOL; xSErrorVelo : BOOL; xReceiveVelo : BOOL; eSTypeVelo : MQTT.MQTT_ERROR; eSMQTTErrorVelo : MQTT.MQTT_ERROR; RSVelo : RS; udiCont : UDINT; //SUBSCRIBE CODE: MQTTSubscribeVelo( xEnable:= MQTT_CLIENT.xConnection_Broker AND NOT xSErrorVelo AND NOT JSON_VELO.xKeepAliveVelo, pbPayload:= JSON_VELO.psPayloadJsonVelo, udiMaxPayloadSize:= SIZEOF(JSON_VELO.sPayloadJsonVelo), udiPayloadSize => udiPayloadSizeVelo, mqttClient:= MQTT_CLIENT.ClientMQTT, wsTopicFilter:=wsTopicSubscribeVelo, xDone => xSDoneVelo, xError=> xSErrorVelo, xReceived => xReceiveVelo, eMQTTError=> eSMQTTErrorVelo ); RSVelo(SET := xReceiveVelo, RESET1 := JSON_VELO.xKeepAliveVelo);
Last updated: 2024-09-09
Post by duvanmoreno24 on Modbus writing on value change
CODESYS Forge
talk
(Post)
Yes, I tried to do what you put in the first code. However, I have a problem with that and that is that the inputs must be declared with the type. I have many data types running in my code (real, int, uint, bool) and I can't put them in the same function, another thing is that I need to instantiate that function for everything I want to write to the slave. You put a for to 200 but it means that it has to be the same data type and inside the array, but I want to get them individually. I'm struggling to do it in a good and efficient way like wago's E-cockpit does. in the first screenshot you can see, you simply type in value, change the package of things you want to write in value change and it does everything by itself automatically, without comparing any old and new values and even less having the need to activate a bool. , it is perfect.
Last updated: 2024-04-03
I want to convert a WORD to a hex string like 15.432 to '3C48'
CODESYS Forge
talk
(Thread)
I want to convert a WORD to a hex string like 15.432 to '3C48'
Last updated: 2024-04-19
How to allow a user to handle certificates without access to sourcecode?
CODESYS Forge
talk
(Thread)
How to allow a user to handle certificates without access to sourcecode?
Last updated: 2024-08-07
how to add module to raspberry pi
CODESYS Forge
talk
(Thread)
how to add module to raspberry pi
Last updated: 2020-11-24
how to set custom from/to timestamp in Trend
CODESYS Forge
talk
(Thread)
how to set custom from/to timestamp in Trend
Last updated: 2020-03-31
Unable to connect to git remotes through Codesys.
CODESYS Forge
talk
(Thread)
Unable to connect to git remotes through Codesys.
Last updated: 2023-11-10
Codesys to Android App to Cloud Database
CODESYS Forge
talk
(Thread)
Codesys to Android App to Cloud Database
Last updated: 2022-03-10
How to map to values in CAN BUS
CODESYS Forge
talk
(Thread)
How to map to values in CAN BUS
Last updated: 2021-04-29
Using Codesys WebClinet to talk to Sensibo API
CODESYS Forge
talk
(Thread)
Using Codesys WebClinet to talk to Sensibo API
Last updated: 2021-07-20
How to add a VFD to Codesys
CODESYS Forge
talk
(Thread)
How to add a VFD to Codesys
Last updated: 2023-05-12
How to convert Function block diagram to Structured text
CODESYS Forge
talk
(Thread)
How to convert Function block diagram to Structured text
Last updated: 2015-05-04
How to save sensor values ββto a file
CODESYS Forge
talk
(Thread)
How to save sensor values ββto a file
Last updated: 2023-02-22
HMI will not connect to PLC to display visu.
CODESYS Forge
talk
(Thread)
HMI will not connect to PLC to display visu.
Last updated: 2020-02-28
how to Connect CodeSys to many devices?
CODESYS Forge
talk
(Thread)
how to Connect CodeSys to many devices?
Last updated: 2017-08-16
how to communicate codesys to other PLC
CODESYS Forge
talk
(Thread)
how to communicate codesys to other PLC
Last updated: 2011-07-06
Not able to connect to Codesys Gateway on locl machine...
CODESYS Forge
talk
(Thread)
Not able to connect to Codesys Gateway on locl machine...
Last updated: 2021-03-12
how to Connect CodeSys to many devices ?
CODESYS Forge
talk
(Thread)
how to Connect CodeSys to many devices ?
Last updated: 2017-08-17
Connect to telnet server. Where to start?
CODESYS Forge
talk
(Thread)
Connect to telnet server. Where to start?
Last updated: 2022-06-23
Unable to generate chm due to Pi library warning... [solved]
CODESYS Forge
talk
(Thread)
Unable to generate chm due to Pi library warning... [solved]
Last updated: 2018-01-29
To search for an exact phrase, put it in quotes. Example: "getting started docs"