Post by macros8 on Translation - How to get text as reference in Frames translated?
CODESYS Forge
talk
(Post)
Hi, thanks for the link. Maybe I create elements in incorrect way. I always use Interface Editor to create variables which are used inside element (see pics). After that I place element in my visu and use Reference property to link variable or set the value. In that case the value of string is not transferred to general text list for translation as I mentioned before. Do I have to all properties which influence behavior of my element create in Frame configuration instead? What´s the difference to the Interface editor? Thanks a lot. M.
Last updated: 2024-01-02
Post by jdjennings1962 on Trouble accessing Math functions in OSCAT library
CODESYS Forge
talk
(Post)
Hi all, I am trying to utilize the ARRAY_SDV standard deviation function, part of the Math group in the OSCAT library downloaded from the CODESYS store. My Codesys version is 3.5.19.10. When I add the OSCAT to my Library, it shows a subset of the library (Standard) as fully installed and signed (see pic). However, the Math functions are not in this Standard group. The Math functions I need can be viewed as source code in the full OSCAT_BASIC, though this the symbol next to this library suggests it is source only and not fully installed. When I try to declare an instance of the ARRAY_SDV function in a program, it is not known. I have tried reinstalling and Building . . . Any help would be greatly appreciated. Jeff
Last updated: 2024-01-06
Post by alexgooi on Function Blocks and arrays of function blocks
CODESYS Forge
talk
(Post)
Hi Jack, I think you have to look at a FB in a different way. A Function block (Class) can contain its own data. In other words don't define loose data in your GVL, but define a instance of a FB (Object) in your GVL: Example: Function_Block Basic_Class VAR_INPUT Open_Command: BOOL; END_VAR VAR_OUTPUT Opened: BOOL; END_VAR if Open_Command then Opened := TRUE; ELSE Opened := FALSE; END_IF Global Variables Objects: ARRAY[1..100] OF Basic_Class; //Here you ar defining you objects END_VAR In your code you can directly acces the data and couple it to the IO: GVL.Objects[1].Open_Command := %IX0.0; %QX0.0 := GVL.Objects[1].Opened; //To call the code itself use: GVL.Objects[1](); If you want to take this a step further you are also able to add methods and properties to the FB/Class end thereby creating a OOIP program
Last updated: 2024-02-15
Post by khaledkhalil on Import OPC UA model to Codesys
CODESYS Forge
talk
(Post)
I have added a models in SiOME which a software to design nodes and add instances. and created a resultant xml file. I tried to import the xml file to Codesys through OPC UA information model Repository the problem i don't know how to view my objects which i have designed. and map it to my PLC to make viewable on my server UaExpert. I watched the tutorial video https://youtu.be/aJhzN3Uk-Do?feature=shared. But it only give you how to add the Information model, and my resultant model doesn't have information type. So how in Codesys i can view a model which i have designed in SiOME and mapped my instances (Objects, Variable or methods) with my Variables in PLC I saw people do it in Tia Portal or other Software, but i have no clue how to do it on CODESYS
Last updated: 2024-03-12
Post by ph0010421 on Stepper Drive with Ethercat
CODESYS Forge
talk
(Post)
Hello That's certainly CiA402. I'll attach a part of the manual for my servos, but the state diagram should be the same at yours. To be sure, get one from your manufacturer. Look at the bits in the StatusWord to see where you are in the diagram, then twiddle the bits in the ControlWord to get you to the next step. Then there are other bits in the StatusWord to tell you 'InPosition' and things like that. From the screenshot, as it mentions only 'PositionProfile' the driver will create the motion profile. So you need to put a target position in here - there should be profile velocity somewhere? Possibly, you need to write these with SDO's? At the minimum, you need to write a value to 0x6081, 0x6083 and 0x6084 (velocity, accel, decel)
Last updated: 2024-03-22
Post by tecnocons on Trouble Writing Files to External Paths in CODESYS
CODESYS Forge
talk
(Post)
Hello everyone, I'm encountering an issue in CODESYS regarding writing files to external paths. Despite correctly configuring the placeholder in the CODESYSControl_User.cfg file to allow access to an external folder, CODESYS doesn't seem to write any files, and no errors are reported. The issue on the older versions was absent with no placeholders. I've checked the operating system permissions, and they seem to be in order, but the issue remains. Has anyone faced a similar situation or has any suggestions on how I might resolve this problem? Any help would be greatly appreciated. Thank you in advance for your support. I'm using raspberry PI as a logger. RPI3 Buster Codesys 32bit SL V4.11 Codesys Win64 3.5.20 [SysFile] PlaceholderFilePath.1=/home/pi/scan, $SCAN$
Last updated: 2024-04-09
Post by damian177 on CM4S GPIO's in Codesys
CODESYS Forge
talk
(Post)
Hi, I am running my application on device based on Compute Module 4S (Cortex-A72 (ARMv8) 64-bit ). On this device I installed RPi Runtime in 4.11.0.0 version. In my project I use device: Codesys Control for Raspberry Pi 64SL and my project works, but I actually do not have acces to all GPIO's , because GPIOs Compute Module is available only in 3.5.16.0 version and it doesn't work. Properly work GPIOs B+/Pi2 but using this device I do not have acces to all GPIO's in CM4S. Anyone of can tell me how add GPIOs Compute Module 4.11.0.0 to my project ?
Last updated: 2024-05-28
Post by alez on CANopen safety , SRDO error behavior
CODESYS Forge
talk
(Post)
I have a project in which there is a Safety device in CANopen, and the PLC interfaces with it as Master. I would like to understand if it is possible to set the behavior in case one of the SRDOs that I receive from the slave is no longer received. From what I have seen, if the SRDOs are not received, the CANopen safety status becomes "Not in progress" and the mapped variables freeze at the last value detected. I want to understand if it was possible to set the variables connected to the SRDOs to take a default value (e.g. zero) in the event of a CANOpen error during reception.
Last updated: 2024-07-15
Post by damian177 on Problem with downloading OPC UA tags by Data Source Manager
CODESYS Forge
talk
(Post)
Hi, In Codesys V3.5 SP20, using Data Source Manager I am trying to connect to the OPC UA server and receive tags from it. The connection is ok, but the Codesys have a problem with downloading Tags group. The window (downloadingTags.jpg in attachement) never stop. After waiting for a while, I disconnect the connection and only the Server group remains downloaded, with OPC UA server diagnostic data (and this is read in Codesys). Of course, I tried connected via another OPC UA client : UaExpert , and everything works as it should, all tags are downloaded (Uaexpert.jpg screen). Has anyone on the forum encountered the OPC UA client configuration in Codesys? Is it possible to manually request the appropriate tags from the OPC server for reading in Codesys?
Last updated: 2024-09-03
Post by pierre on difference between stub file and source file in scriptengine
CODESYS Forge
talk
(Post)
I included the stub files of scriptengine (codesys python api) in a directory scriptengine of a project. I tried to include librarymanager like that: from scriptengine import librarymanager visual studio code detected an error. It said librarmanager could not be found. Indeed in the stub file, this was library_manager. But if I change it in my code, the plugin doesn t work anymore. I found an easy solution to this problem. I ve just changed the copied stub files.(library_manager -> librarymanager) But I think it would be better if you update it yourself in the future.
Last updated: 2024-09-20
Post by pierre on difference between stub file and source file in scriptengine
CODESYS Forge
talk
(Post)
I included the stub files of scriptengine (codesys python api) in a directory scriptengine of a project. I tried to include librarymanager like that: from scriptengine import librarymanager visual studio code detected an error. It said librarmanager could not be found. Indeed in the stub file, this was library_manager. But if I change it in my code, the plugin doesn t work anymore. I found an easy solution to this problem. I ve just changed the copied stub files.(library_manager -> librarymanager) But I think it would be better if you update it yourself in the future.
Last updated: 2024-09-20
Post by thn-power on How to change OPC NodeId IdentifierType
CODESYS Forge
talk
(Post)
Hi Yet another OPC UA question. When setting up a OPC server using "Communcation manager" (Symbol set and information model) in Codesys the NodeId is always given as "opaque" type. At least when browsing using UAExpert. Other standard OPC objects use numeric (or string) identifier, but for some reason my variables seems to get opaque/binary type. See attached photo. How can I change this? I can't see that this is a parameter in the CodesysControl.cfg. Can this be specified in the information model nodeset? And is it possible to specify the exact numeric or string NodeId for each instance? And on a related topic, is there a way to export the OPC server nodeId's with variable name so that it can be imported in a OPC Client? The .xml files in the project folder does not seem to contain the NodeId.
Last updated: 2024-09-20
Post by andrebrandt on FB string and naming
CODESYS Forge
talk
(Post)
Hi Tim. Not quite correct. What i'd like, is when you place the FB in prog, i choose a block NTC10k, and name this RT401. What i'm trying to do, is to get the name RT401 automaticly into the FB, so i can put this into the string i pass in a struct. So in var in POU, i saw this a place i could do this, RT401: NTC10k(Tag:='RT401'), but i can't get this to work. I shurly must have had something like this in FB: FUNCTION_BLOCK NTC10k String TAG But it's here where I'm stuck...
Last updated: 2024-09-30
Post by timvh on Modbus TCP & RTU with Control for Linux SL
CODESYS Forge
talk
(Post)
RS485 doesn't seem very logical to use in VPLC's in my opinion. I also don't know if this is supported.... But for TCP/IP, I think you still need to configure the Nic settings. See the attached png. In my case enp6s0. When changing this setting, restart the VPLC. What is really nice, is that you don't have to configure the IP address setting in Linux. By setting the Nic to a certain IP address in the CODESYS instance configuration, this is automatically done for you. I only tested this with EtherCAT, but I guess this works the same for Modbus TCP/IP.
Last updated: 2024-10-23
Post by xabier on BUG CODESYS-NO WORK AUTOMATICALLY RESTARSLAVES
CODESYS Forge
talk
(Post)
I detect a Bug of Codesys....NO WORK AUTOMATICALLY RESTARSLAVES. I explain the secuence: I have click in my project the option AUTOMATICALLY RESTARSLAVES In the moment start my Ipc, the network ethercat start correctly I disconnect the wire of my first slave and later connect again the wire..(see the screen Bug Codesys restart slave1) NO work the restart automatic slaves...and is not possible execute of FB MC_REset beacuause appear this error (see the screen Bug Codesys restart slave2) The only way for resolver this problem is execute the FB SMC3ReinitDrive I replay the same with PLC BECKHOFF in Twincat3 and I havent this problem...In the moment connect the wire again in the slave the comunication of ehterCat restart and the slave comunication again with out problem
Last updated: 2024-11-07
Post by paulg on RasPi CAA Serial example - unexpected behavior during debug
CODESYS Forge
talk
(Post)
I've trimmed down the CAA Serial Codesys example to only listen on one port but, when stepping through the Case structure in debug mode, it jumps out of the structure during a specific point in every scan (I'll point it out below after describing the setup and listing the code). I'm using a Pi 4 Model B, and I have an Arduino Nano Every plugged in via USB which is streaming the following serial message at 1 Hz: Time since opening connection: 1 s Time since opening connection: 2 s ...and so on. The Pi shows the Nano at /dev/ttyACM0 so I edited CODESYSControl_User.cfg to read: Linux.Devicefile=/dev/ttyACM The code in my PLC_PRG is (ignore some of the comments, I hadn't deleted them out from the original example): PROGRAM PLC_PRG VAR xStartTest : BOOL:= TRUE; iState : INT; xTestDone : BOOL;(* True, when the test was done succesfully *) (* Settings to communicate with the COM Port *) aCom1Params : ARRAY [1..7] OF COM.PARAMETER; como1 : COM.Open; comc1 : COM.Close; comw1 : COM.Write; comr1 : COM.Read; //sWrite : STRING := 'Test String!'; sRead : STRING(25); szRead : CAA.SIZE; xCom1OpenError : BOOL; xCom1CloseError : BOOL; xCom1WriteError : BOOL; xCom1ReadError : BOOL; END_VAR //This example shows the communication of two COM Ports with each other. //The first one writes a string of characters, which is read by the second one. //After successful execution, the two COM Ports are closed and the test is done. IF xStartTest THEN CASE iState OF 0: //The parameters are set for the COM Port aCom1Params[1].udiParameterId := COM.CAA_Parameter_Constants.udiPort; aCom1Params[1].udiValue := 1; // the correct Port should be adapted aCom1Params[2].udiParameterId := COM.CAA_Parameter_Constants.udiBaudrate; aCom1Params[2].udiValue := 115200; aCom1Params[3].udiParameterId := COM.CAA_Parameter_Constants.udiParity; aCom1Params[3].udiValue := INT_TO_UDINT(COM.PARITY.NONE); aCom1Params[4].udiParameterId := COM.CAA_Parameter_Constants.udiStopBits; aCom1Params[4].udiValue := INT_TO_UDINT(COM.STOPBIT.ONESTOPBIT); aCom1Params[5].udiParameterId := COM.CAA_Parameter_Constants.udiTimeout; aCom1Params[5].udiValue := 0; aCom1Params[6].udiParameterId := COM.CAA_Parameter_Constants.udiByteSize; aCom1Params[6].udiValue := 8; aCom1Params[7].udiParameterId := COM.CAA_Parameter_Constants.udiBinary; aCom1Params[7].udiValue := 0; //The first Port is opened with the given parameters como1(xExecute := TRUE, usiListLength:=SIZEOF(aCom1Params)/SIZEOF(COM.PARAMETER),pParameterList:= ADR(aCom1Params)); IF como1.xError THEN xCom1OpenError := TRUE; iState := 1000; END_IF //After a successful opening, the next state is reached IF como1.xDone THEN iState := 15; END_IF 15: // the reading process is started comr1(xExecute := TRUE,hCom:= como1.hCom, pBuffer:= ADR(sRead), szBuffer:= SIZEOF(sRead)); IF comr1.xError THEN xCom1ReadError := TRUE; END_IF //After completion the size of the written bytes are saved IF comr1.xDone OR comr1.xError THEN szRead := comr1.szSize; iState := 20; END_IF 20: // If everything was successful the ports are closed and the handles are released comc1(xExecute := TRUE,hCom:= como1.hCom); IF comc1.xError THEN xCom1CloseError := TRUE; END_IF IF comc1.xDone OR comc1.xError THEN iState := 25; END_IF 25: // The first port is closed and the used handle released xTestDone := TRUE; xStartTest := FALSE; iState := 0; como1(xExecute := FALSE); comw1(xExecute := FALSE); comc1(xExecute := FALSE); ELSE iState := 0; END_CASE END_IF I realize as I write this that the .udiPort should be 0 and not 1, but that shouldn't be causing the issue I'm seeing. I'm forcing xStartTest:=TRUE every scan so that I can step into each line and observe what's happening. What I see is that the port parameters are set and the port is opened with no errors, but the code jumps out of the case structure to the last line every time it reaches (and I step into) the iState:=15 line (at the end of the iState:=0 block). So every scan cycle it goes through the block for iState=0 and jumps out at the same spot. I'm a little new to PLC programming so I may be misunderstanding the flow, but shouldn't this case structure keep moving down in the same scan? If it only handles one case per scan, why doesn't the value of iState persist? Thanks! Update: I restarted the Codesys control today and I was then able to see an error for como1.eError of "WRONG_PARAMETER". I tried doing some digging and another post made me think I should add another line to CODESYSControl_User.cfg, so I now have: [SysCom] Linux.Devicefile=/dev/ttyACM portnum := COM.SysCom.SYS_COMPORT1 So now when I set .udiPort to 1, I get "NO_ERROR" but I also don't read anything from the port (i.e. szRead = 0 always). If I try setting the port to 0 (which I'm confused about, because I added a COMPORT1 line but the device shows on the Pi as ACM0), I get the "WRONG_PARAMETER" error again. Is there an easier way to troubleshoot the Pi and view what ports the Codesys runtime is actually able to see while the Pi is running?
Last updated: 2024-06-06
Post by raghusingh77 on Get $100 EVERY TIME USE THIS COUPON CODE OF ACU934948 TEMU
CODESYS Forge
talk
(Post)
Temu has quickly established itself as a leading online shopping platform, offering customers a wide array of products at unbeatable prices. As we move through 2024, shoppers can take advantage of exciting promotions, including the $100 off coupon code [ACU934948]. This article will guide you through how to maximize your savings with this code and other fantastic offers available on Temu. Exclusive Discounts for New Users For those who are new to Temu, the platform offers an enticing 30% discount on orders over $39. By using the coupon code [ACU934948], first-time users can enjoy this immediate savings opportunity. Additionally, new users can benefit from a special promotion that provides up to 75% off their first purchase. This makes it an ideal time for newcomers to explore Temu's extensive inventory while enjoying significant discounts. Massive October Promotions October 2024 is shaping up to be a month filled with incredible deals on Temu. Shoppers can access discounts of up to 90% off select items when using the coupon code [ACU934948]. This promotion is part of Temu's strategy to attract both new and returning customers during the busy shopping season. Flat Discounts and Bundle Offers The $100 off coupon code [ACU934948] stands out as a valuable offer, providing a flat discount that enhances the overall value of your purchases. This coupon is applicable not only for new users but also for existing customers, ensuring that everyone can benefit from substantial savings. Furthermore, Temu has introduced bundle offers that combine this $100 discount with additional promotions, allowing customers to save up to 70% on select products. Temu Rewards Program for Loyal Customers Temu values its loyal customers through its comprehensive Rewards Program, which offers exclusive deals and discounts. By using the coupon code [ACU934948], existing customers can enjoy additional benefits, including potential cash-back offers. For example, eligible purchases may yield up to 25% cash back, making it even more rewarding to shop at Temu. How to Redeem Your Coupons Using Temu's coupon codes is straightforward: Browse Products: Start by exploring Temu’s extensive range of items. Add to Cart: Once you find what you like, add it to your shopping cart. Apply the Coupon Code: At checkout, enter the coupon code [ACU934948] in the designated field and click "Apply." Complete Your Purchase: Review your discounted total before finalizing your order. Tips for Maximizing Savings Redeem Temu Coupon Code [ACU934948]. TEMU COUPON $100 OFF [ACU934948] TEMU COUPON $100 OFF FOR EXISTING CUSTOMERS [ACU934948] TEMU COUPON $100 OFF FIRST ORDER [ACU934948] TEMU COUPON $100 OFF REDDIT [ACU934948] TEMU COUPON $100 OFF FOR EXISTING CUSTOMERS REDDIT [ACU934948] TEMU COUPON $100 OFF NEW USER [ACU934948] TEMU COUPON $100 OFF FOR EXISTING CUSTOMERS 2024 [ACU934948] TEMU COUPON $100 OFF CODE [ACU934948] TEMU COUPON $100 OFF FIRST ORDER FREE SHIPPING [ACU934948] TEMU COUPON $100 OFF FOR EXISTING CUSTOMERS FREE SHIPPING USA [ACU934948] TEMU COUPON $100 OFF HOW DOES IT WORK [ACU934948] TEMU COUPON $100 OFF FOR EXISTING CUSTOMERS CANADA [ACU934948] TEMU COUPON $100 OFF 2024 [ACU934948] TEMU COUPON $100 OFF FOR NEW CUSTOMERS [ACU934948] TEMU COUPON $100 OFF CANADA [ACU934948] TEMU COUPON $100 OFF FOR EXISTING CUSTOMERS FIRST ORDER [ACU934948] TEMU 100 OFF COUPON BUNDLE [ACU934948] 100 COUPON CODES [ACU934948] 1 BUCKS TO PHP [ACU934948] IS THERE A COUPON IN THE PHILIPPINES [ACU934948] 100 BUCKS TO PHP [ACU934948] TEMU $100 OFF COUPON [ACU934948] TEMU $100 OFF CODE [ACU934948] TEMU 100 VALUE COUPON BUNDLE [ACU934948] TEMU COUPON $100 OFF FOR EXISTING CUSTOMERS FREE SHIPPING [ACU934948] TEMU 100 OFF COUPON CODE LEGIT [ACU934948] TEMU 100 OFF COUPON CODE REDDIT [ACU934948] TEMU 100 OFF COUPON CODE FOR EXISTING USERS [ACU934948] TEMU 100 OFF COUPON CODE UK [ACU934948] TEMU COUPON CODE $100 OFF FREE SHIPPING [ACU934948] TEMU COUPON CODES 100 PERCENT OFF [ACU934948] WHAT IS A HIGH COUPON RATE [ACU934948] HOW TO CALCULATE COUPON RATE WITHOUT COUPON PAYMENT [ACU934948] WHAT IS THE COUPON RATE [ACU934948] HOW TO CALCULATE COUPON VALUE [ACU934948] USING COUPONS AND REBATES TO LOWER THE PRICE OF AN ITEM IS AN EXAMPLE OF [ACU934948] TEMU 100 DOLLAR OFF COUPON [ACU934948] DOMINOS COUPON CODE 100 OFF [ACU934948] DOMINO'S 100 RS OFF COUPON CODE [ACU934948] TEMU COUPON $100 OFF EXISTING CUSTOMERS [ACU934948] WHAT IS 10 OFF 100 DOLLARS [ACU934948] 100 OFF PROMO CODE [ACU934948] 1 CASHBACK ON 100 DOLLARS [ACU934948] IS TEMU 100 OFF COUPON LEGIT [ACU934948] TEMU COUPON $100 OFF [ACU934948] TEMU COUPON $100 OFF LEGIT [ACU934948] Temu Coupon Code $100 OFF [ACU934948] Stacking Discounts: While you cannot apply multiple coupon codes in one transaction, ensure you're using the most beneficial code available. Lightning Deals: Keep an eye out for limited-time "Lightning Deals," which often feature discounts of up to 80%. Free Shipping Offers: Temu provides free standard shipping on all orders, enhancing the value of your purchases. Conclusion With its competitive pricing and generous promotional offers like the $100 off coupon code [ACU934948], Temu is an excellent choice for savvy shoppers looking for great deals. Whether you are a new user eager to explore or an existing customer ready to reap rewards, Temu provides ample opportunities to save significantly on your purchases. Don't miss out—redeem your coupons today and enjoy an exceptional shopping experience filled with incredible value
Last updated: 2024-10-26
Post by raghusingh77 on Get $100 Off Temu Coupon Code [ACU934948] | + 30% Discount
CODESYS Forge
talk
(Post)
Your Guide to Temu Coupon Code [ACU934948] In the ever-evolving world of online shopping, Temu has emerged as a frontrunner, offering customers substantial discounts and promotions. As we approach the end of 2024, Temu is rolling out some impressive deals, including a $100 off coupon code [ACU934948] that can significantly enhance your shopping experience. This article will explore how to maximize your savings with this code and other exciting offers available on the platform. Exclusive Discounts for New Users For those new to Temu, the platform offers a 30% discount on your first order simply by using the coupon code [ACU934948]. This introductory offer makes it easy for first-time users to explore Temu's extensive inventory while enjoying immediate savings. Additionally, new users can benefit from an even more generous offer of up to 75% off their first purchase when they redeem this coupon. Massive October Promotions October 2024 is shaping up to be an exciting month for shoppers on Temu. With the coupon code [ACU934948], customers can access discounts of up to 90% off selected items. This promotion is part of Temu's strategy to attract new customers and reward loyal ones during this busy shopping season. Flat Discounts and Bundle Offers The standout feature of the $100 off coupon code [ACU934948] is its applicability across various orders, providing a flat discount that enhances the overall value of your purchases. This coupon is not just limited to new users; existing customers can also take advantage of this offer. Furthermore, Temu has introduced bundle offers that combine this $100 discount with additional savings, allowing customers to save up to 70% on select products. Temu Rewards Program for Loyal Customers Temu values its existing customers through a robust Rewards Program that offers exclusive deals and discounts. By using the coupon code [ACU934948], loyal shoppers can enjoy additional benefits, including potential cash-back offers. For instance, eligible purchases may yield up to 25% cash back, making it even more rewarding to shop at Temu. How to Redeem Your Coupons Using Temu's coupon codes is straightforward: Browse Products: Start by exploring Temu’s extensive range of items. Add to Cart: Once you find what you like, add it to your shopping cart. Apply the Coupon Code: At checkout, enter the coupon code [ACU934948] in the designated field and click "Apply." Complete Your Purchase: Review your discounted total before finalizing your order. Tips for Maximizing Savings Stacking Discounts: While you cannot apply multiple coupon codes in one transaction, ensure you're using the most beneficial code available. Lightning Deals: Keep an eye out for limited-time "Lightning Deals," which often feature discounts of up to 80%. Free Shipping Offers: Temu provides free standard shipping on all orders, enhancing the value of your purchases. Conclusion With its competitive pricing and generous promotional offers like the $100 off coupon code [ACU934948], Temu is an excellent choice for savvy shoppers looking for great deals. Whether you are a new user eager to explore or an existing customer ready to reap rewards, Temu provides ample opportunities to save significantly on your purchases. Don't miss out—redeem your coupons today and enjoy an exceptional shopping experience filled with incredible value
Last updated: 2024-10-26
Post by jackbrady on Function Blocks and arrays of function blocks
CODESYS Forge
talk
(Post)
Hello, I am new to Codesys and PLC programming in general (please go easy ha!) I'm not looking for code to be written for me just some help and pointing in the right direction. I am writing some code to send commands to a relay based on input values (to put it simply). Quite basic stuff. I have wrote a function block that takes a global variable (Open_command:BOOL) and outputs to another global variable (Opened : BOOL). The function block is simulating a device so I'll eventually get the globals from that. I now need to create multiple versions of this function block/ device (lets say 100) but I need each iteration of that function block to reference it's own relevant global variable. I think that the best way of doing this would be to use arrays, although I could be wrong. I am aware that for up to 100 instances I could very well manually assign everything but that seems rather time consuming and I want a fancier way of doing it. Here is a very basic example of what I am looking to do, please note I have not written this in proper code it's just to show what I mean. Global Variables V[0-100] int Open_command [0-100] Bool Opened [0-100] Bool Function Block var input x : BOOL Var output y : BOOL if x then y = TRUE ELSE y = FALSE The input to my function block will be Open_command, output will be Opened Example code. If V[x] > 10 then Open_command [x] = TRUE ELSE Open_command [x] = FALSE (So when V1 goes above 10 I need Open_command1 = TRUE therefore initiating FB1 output. V2 > 10, open_command2 = True > FB2 output V3 > 10, open_command3 = True > FB3 output ... ... ) What I can't seem to figure out is how to tie all this together, I have read through the codesys documentation and if anything it has confused me more! ha. Apologies for the poorly written post but hopefully you understand what I am trying to get at. Thanks, Jack
Last updated: 2024-02-14
Post by imdatatas on MC_CamIn did not work properly with SMC_FreeEncoder on SoftMotion 4.17.0.0
CODESYS Forge
talk
(Post)
Hello, I am facing a problem with the new Softmotion 4.17.0.0 version. Has anyone encountered a similar problem, what is the solution? I would be happy if you could share it. Problem description: -- "SMC_FreeEncoder" encoder axis is the master, -- The motor of the servo driver on the EtherCAT bus is the slave axis. -- When the MC_CamIn block executed, the InSync output is activated. However, although the master encoder axis position value changes, there is no movement in the slave servo axis! Test steps: 1-) EtherCAT servo axis installed, configured and motion test was performed with MC_Jog. No problem. 2-) Softmotion general axis pool > SMC_FreeEncoder was added and pulse amount configuration was performed. No problem. 3-) Incremental encoder actual count value was transferred to the "SMC_FreeEncoder.diEncoderPosition" variable as DINT under the ethercat task in every cycle and the encoder axis position value was observed. No problem. 4-) A simple CAM table with a 1:1 ratio was created under the project tree. (For example: Simply, when the encoder rotates 1 turn, the motor will rotate 1 turn.) 5-) The SMC_FreeEncoder axis enabled with MC_Power and brought to the StandStill state. 6-) The MC_CamTableSelect block was run with default input values ​​(all absolute) and only the Cam table name was specified. The Done output was seen successfully. No problem. 7-) The MC_CamIn block was activated with default input values ​​(absolute) and only the master encoder axis name, slave servo axis name, CamTableID input pins was specified and then "Execute" input set to TRUE. 8-) The InSync output information of the MC_CamIn block observed as TRUE. However, although the encoder axis value changed, the position value of the slave axis did not change at all, it did not move. It always remained at 0.0mm. 9-) When I repeated the same steps above, only changing the master axis to SM_Drive_Virtual instead of FreeEncoder and gave movement to the virtual axis, this time the slave axis moved successfully. However, when the same steps and operations are performed with the same IDE just downgrade SoftMotion version from 4.17.0.0 to 4.10.0.0, everything works normally and without problems as expected in MC_CamIn block with FreeEncoder master. (By the way, The used IDE version is Codesys V3.5 SP20patch3.) Best Regards Imdat
Last updated: 2024-11-11
Post by ofey on Codesys Soft PLC OPC UA server
CODESYS Forge
talk
(Post)
Hi! I'm sorry if this has been asked before. I have tried looking up previous topics regaring this, but even though I'm following tutorials and other posts I cant seem to get this to work consistently. I actually got the connection established on a test project after some trial and error. I only got it to work with the "Anonymous login". But after i deleted the test project and tried to get the same thing to work on another project I cant get it to work anymore. What I'm trying to do: Set up and OPC UA Server using CODESYS with the free soft PLC. I then try to connect to the OPC UA Server with the program "UaExpert". What happens: I get the error Error "'BadUserAccessDenied' was returned during ActivateSession". What I have done in CODESYS: - Added the object "Symbol configuration" and checked some test variables - Checked "Support OPC UA features - In "Communication settings -> device -> Change runtime security policy" I have checked "Allow anonymous login" What I have done in UAExpert: - Found the OPC UA server under "local". (It is showing two servers though, I do not know why. It showed the same when it worked yesterday). Se attachment - Checked "Anonymous" under "Authentication settings in the OPC UA server. I'm new to CODESYS, so it could be something elementary wrong in my settings. Maybe something in the user settings in CODESYS regarding user rights or something?
Last updated: 2023-09-14
Post by captaincookie on increase default string length in queue
CODESYS Forge
talk
(Post)
Hello, I'm using Codesys V3.5 SP18 Patch 4. In the ElementCollectionExample Project from Codesys, I test the SimpleQueueExample in a Control Win V3 x64 environment. I try to add a string of 95 characters length to a queue. The default length of strings is defined as 80 characters. In the initialization of a string variable, it is possible to increase the length by the definition of e.g. STRING(1000). But when I write the string defined like this to the queue, only 80 characters are written to it and the rest is missing. I think the default length is still set in the queue definition, so it is necessary to change this, isn't it? Is there any option to increase the default length of strings in the queue? Attached you can find the used project. Thanks in advance. If any information are missing or my description unclear please let me know.
Last updated: 2023-10-05
Post by edepalos on Text list from sd card
CODESYS Forge
talk
(Post)
Hi guys, I have a textlist in my project which is working just as expected in a drop down list. I would like to move this text list to a sd card and access it from there, because I want to ease the editing of the contents of this textlist. I'm imagining a solution like the operator shuts down the plant, takes the sd card out, edits the textlist on the card with a windows machines notepad, then reinserts the card in the PLC and restarts the plant, having the new content of the textlist populating the dropdown list. I'm sorry that I'm asking you to spoonfeed me, but I did not find anything straightforward to do this... I saw in the Project>Project settings>Visualisation a relative path thingy, but I have the plant in operation and I would not like to make 100 trial and errors right now... I'm also not interested in SysLib file read commands and stuff, I would just like to access the file from the cards part, I don't want to replace its contents dynamically or such... nor I have language files or recipes... Thank You in advance! Br, Ede
Last updated: 2024-01-16
Post by duvanmoreno24 on Modbus writing on value change
CODESYS Forge
talk
(Post)
Yes, I tried to do what you put in the first code. However, I have a problem with that and that is that the inputs must be declared with the type. I have many data types running in my code (real, int, uint, bool) and I can't put them in the same function, another thing is that I need to instantiate that function for everything I want to write to the slave. You put a for to 200 but it means that it has to be the same data type and inside the array, but I want to get them individually. I'm struggling to do it in a good and efficient way like wago's E-cockpit does. in the first screenshot you can see, you simply type in value, change the package of things you want to write in value change and it does everything by itself automatically, without comparing any old and new values and even less having the need to activate a bool. , it is perfect.
Last updated: 2024-04-03
Post by rmaas on Strange Behavior on Raspberry Pi
CODESYS Forge
talk
(Post)
Hello, what you are seeing is not strange behavior. The problem is that everyting is happening in the same program cycle. After the variable Stepnumber is changed from 10 to 20 for example then you want the program to wait with the next EQ until the next program cycle. Else every EQ will be be true because in every line the variable Stepnumber is increased. When the program arrives (still in the same cycle) at the line with the timer, the Stepnumber has been increased to 30 in the meantime and the timer will allway be ON because even though the variable is written to 10 in this line in the next cycle it starts with 10 and will be 30 again before reaching the timer in line 8. Not very good at explaining stuff but i hope you get the problem. See screenshot below for an example of one way you could solve this...
Last updated: 2024-06-18
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND
or OR
.