Post by cer-wa on Not able to connect multiple profinet encoder in codesys Linux ARM64
CODESYS Forge
talk
(Post)
Hello, currently im working with a RevPi connect 5 on a codesys project. Up until now I was having a blast because things were going really smooth but for like almost a day im kind of stuck on the integration of multiple profinet sensors into my project. This is kind of a bummer because that should be an easy thing to do. What I tried so far was to create and additional ethernet adapter where I then tried to connect my devices. in the beginning I tried to connect the devices directly which was not working because I could assign the IP-adress only to the ethernet adapter and not to the devices but the device was found in the device repository (this gets important in the second part) So what I tried next was to setup a PN-Controller and connect my devices subsequently to the Controller. Sadly now the devices wont show up in the device repository anymore. To me its not clear why this is happening. And the worst thing is: I went ahead and setup a device completely like I would want to have it in the project and when I then click on scan devices I can even find the device. But it can not be added to project for whatever reason eventhough im 100% certain that the gsdml file is the correct one. Can anyone help me with this. Like I said this seems like an easy thing to do and its taking me way longer than expected already. The only thing that came to my mind why this might not work is because I have codesys license which only allows one profinet instance. Could that be the case? The error message seems then pretty unfit but ok. I will be grateful for every advice. Thanks in advance! Best regards!
Last updated: 2025-09-25
Post by jickisticki on Witch library?
CODESYS Forge
talk
(Post)
Crafting my Fellowship Personal Statement was like weaving the threads of my aspirations into a tapestry of words. Each sentence became a brushstroke, painting a vivid portrait of my journey and ambitions. Beyond being just a document, it became a mirror reflecting the depth of my experiences. Like a conductor guiding an orchestra, my personal statement was composed to resonate with my unique voice. In the realm of specialized opportunities, this statement serves as a compass, guiding me toward the next chapter of my professional growth. With each word, I felt the guidance of mentors shaping my story into an eloquent narrative.
Last updated: 2023-08-17
Post by martin-k on Beispieldateien finden / Inhalt der Packages
CODESYS Forge
talk
(Post)
Hallo, ich habe https://store.codesys.com/de/codesys-in-building-automation-examples.html runtergeladen und mit dem Installer und Adminrechten installiert. Jedoch finde ich auf C: keine *.project* Dateien. Kann mir jemand erklären wie ich an die Examples dran komme? Auch von Wago habe ich Packages bekommen in denen Beispiele enthalten sind. Auch hier finde ich nix. (Googel habe ich gefragt. Aber mit den Stichworten kommen viele Treffer die alle nicht hilfreich waren.) In der Hilfe von Codesys habe ich natürlich auch gesucht, aber auch hier nichts erklärendes gefunden. Angeblich findet sich was in C:\Programme\CODESYS 3.5.19.40\CODESYS\Projects oder auch unter C:\Users\BENUZTERNAME\CODESYS Examples Aber wie geschrieben finde ich auf C:\ nix was ein Beispiel wäre. Wäre echt super wenn mir jemand einen Hinweis geben könnte. Danke im Vorraus, Martin
Last updated: 2023-11-16
Post by wbj0t on Raspberry Pi CM4. CoDeSyS files corrupted after hard reset.
CODESYS Forge
talk
(Post)
Hello everyone. Raspberry Pi CM4 after some 1 week of work was hard reset mannualy several times and after these hard resets User Management file was missed (when click login button, enter login/password, error: User Management File missed). Also programm can not open file via SysFile library, but this file exists and size of him is 0 bytes, but must be more any way (I keep some kind of archive via this lib). What happens, how files corrupted? Where do I need try to find this error of the codesys or system whole? In the log files of codesys nothing interesting about this happens. Thanks for reading Is this enough hold PlcLogic and SysFileMap.cfg as reserve copy in another place for restoring the programm? And how automate restoring actions if programm files corrupted?
Last updated: 2024-09-16
Post by janber0206 on Adding PLC to the List view resolves in Unknown Error
CODESYS Forge
talk
(Post)
Problem Solved The Problem was within the Usermanagment. There should be 6 files for the Usermanagment in /var/opt/codesys/ .UserMgmtDB.csv .UserMgmRightstDB.csv .GroupDatabase.csv .UserDatabase.csv_ .GroupDatabase.csv_ .UserDatabase.csv The file .UserMgmtDB.csv was missing. I moved the other files in a savefolder. Full Step by step instructions stop the runtime with sudo /etc/init.d/codesyscontrol stop rename the following files on the PI: (or save them and then delete them) in this directory: /var/opt/codesys/ .UserMgmtDB.csv .UserMgmRightstDB.csv .GroupDatabase.csv .UserDatabase.csv_ .GroupDatabase.csv_ .UserDatabase.csv then restart the Runtime: sudo /etc/init.d/codesyscontrol start now reconnect the PLC via the Automation Server - here you will be asked to create a new CODESYS user password, The user management files deleted above are then created again (in /var/opt/codesys/ on the PI).
Last updated: 2025-02-24
Post by struccc on Multiple applications on one device sharing variables.
CODESYS Forge
talk
(Post)
I don't exactly recall where (I think some release notes), but I read the information that this multiple application / sub application feature is to be discontinued. Please, correct me, if I'm not right about this I am a bit sad about that - I was using that feature with more or less success. However I understand the reason behind the change: it introduces huge complexity, especially when dealing with multicore and safety support... AS I understand, it's to be replaced with the new virtual plc architecture, and standard ways for synchronizing / sharing data... So, for now the "Add application" context menu item was removed, but behind the scene it is still supported... Hint: if you still want to experiment with it, might try copy-paste things within the PLCLogic tree...
Last updated: 2025-02-28
Post by beginner on ERROR: Demo mode for SoftMotion Basic expired. Feature stopped!
CODESYS Forge
talk
(Post)
Hello. Please help me. Sometimes SoftMotion starts in demo mode and stops working after 2 hours. When I check with the license manager, it is recognized normally. I checked the log. After changing online or logging in with a download, the message "**** ERROR: Demo mode for SoftMotion Basic started. Will expire and stop!" was left. Even if you change online or log in with a download, this phenomenon may not occur. Please tell me how to solve this problem. Thank you in advance. Codesys Ver 3.5.20.0 SM3 Basic SoftMotion Ver 4.16.0.0 ※This text was translated using a translator.
Last updated: 2025-03-25
Post by agentcousto on [Bug report] Issue with Importing XML Files Containing "POINTER TO" Variables in Codesys Platform Plugins Versions 2.7 and 2.8
CODESYS Forge
talk
(Post)
Hello, I have developed a Python script that I run to import XML files into my project. For this, I use the Python function import_xml(). Everything was working fine when I was using Codesys platform plugins version 2.6.1.2320, but since I upgraded to versions 2.7 and even 2.8, some files are no longer imported correctly. After some research, I identified that all the files containing variables of the type "POINTER TO" are affected. I have attached a screenshot of the error I am encountering. Do you know about this bug? Do you plan to fix it?
Last updated: 2025-03-26
Post by rossanoparis on Internal Error (ARM): Unsupported conversion! With new version v3.5 SP21
CODESYS Forge
talk
(Post)
I have updated CODESYS development tool to the version v3.5 SP21 (64bit) The previous version was v3.5.20.40 Compiling an existing application with the new evelopment tool I get the following error. kunbusiodrvrevpibridge, 1.4.1.0 (kunbus gmbh): IoDrvScanModules [IoDrvRevPiBridge](Line 51, Column 1 (Impl)): Internal Error (ARM): Unsupported conversion! This error was not reported in the previous compiler version and is now highlighted in a third-party library, which I cannot change or modify. The error is due to the following conversion: m_udiError := TO_UDINT(excCode); . The excCode variable is a system type, declared as shown below, and should be converted to a UDINT excCode : __SYSTEM.ExceptionCode; m_udiError: UDINT; . I would appreciate it if someone could provide feedback on this issue.
Last updated: 2025-04-15
Post by alsiddhartha on TextList name error (fake)
CODESYS Forge
talk
(Post)
Hello, I’m developing a program and for some reason I got this error: C0193: Name '2,Recipe #2GVL' is no valid identifier I was creating a combo box and creating a TextList for my recipe. I couldn't find where the error was, until in the combo box properties in the 'Text List' property in the options it gives me to select, I found '2,Recipe #2' to be able to select (I never created a list with this name) and I can't find a way to delete that option or I can't find where that list is. I tried to delete the TextLists, delete the combo box, to clean the project, but the error still there. How can I delete this option (2,Recipe #2)? Or how can I fix this error?** Thank you.
Last updated: 2025-06-19
Post by jzhvymetal77 on IecVarAccessLibrary.IBaseTreeNode methon
CODESYS Forge
talk
(Post)
I got this code working again. 3S/CoDeSys, your level of obfuscation and lack of documentation turns a simple task into a monumental complex challenge. The issue was that at some point the IecVarAccessLibrary changed and no longer allowed using IBaseTreeNode to retrieve a child or the number of children. The attached code has been updated to use IIecVarAccess6.VarAccBrowseGetChildByIndex instead. The code was also cleaned up but is still a work in progress. The current example only works one layer deep. This means native data types, arrays, and single-layer structures are supported. However, structure arrays and nested structures are not yet supported.
Last updated: 2025-08-25
Post by preimesbergert on Raspberry Pi 4 B HW 1.5 Codesys control 4.10.0 stopps after a few seconds
CODESYS Forge
talk
(Post)
Wanted to play a bit with a raspberry Pi 4 Model B HW 1.5 and Codesys. Regardless of the image (tried 32bit / 64bit version from Raspberry Pi Imager) and with all tested Codesys Control versions (4.2.0, 4.8.0, 4.10.0) and regardless if single core / multicore / 64 bit variant, always is the runtime stopped after about 30sec with the nice message: ooops... this runtime was built for RASPBERRYPI. Hardware version or firmware version not supported! (-7, 0x00000BB8, 0xFFFFFFFB) Whats wrong with it?!?!? I read a lot about the issue in topics from 2020-2021 but it always was stated with new Codesys control version issue will be fixed (4.4 for example) but still it is there.
Last updated: 2023-12-21
Post by preimesbergert on Raspberry Pi 4 B HW 1.5 Codesys control 4.10.0 stopps after a few seconds
CODESYS Forge
talk
(Post)
Wanted to play a bit with a raspberry Pi 4 Model B HW 1.5 and Codesys. Regardless of the image (tried 32bit / 64bit version from Raspberry Pi Imager) and with all tested Codesys Control versions (4.2.0, 4.8.0, 4.10.0) and regardless if single core / multicore / 64 bit variant, always is the runtime stopped after about 30sec with the nice message: ooops... this runtime was built for RASPBERRYPI. Hardware version or firmware version not supported! (-7, 0x00000BB8, 0xFFFFFFFB) Whats wrong with it?!?!? I read a lot about the issue in topics from 2020-2021 but it always was stated with new Codesys control version issue will be fixed (4.4 for example) but still it is there.
Last updated: 2023-12-21
Post by sebastian-hk on Codesys auf einen Cortex M4 lauffähig machen
CODESYS Forge
talk
(Post)
Hallo, wir spielen mit dem Gedanken, Codesys auf einen AT SAM E54 Xplained Pro lauffähig zu machen. dieser besitzt einen Atmel ATSAME54P20A mit einem Cortex M4. Meine Fragen hierbei: Was muss portiert werden, wenn die Zielhardware momentan noch nicht unterstützt wird? Gibt es ggf. Anleitungen, um die Laufzeit auf solch einen Controller zu bringen? Muss hierbei ein eigener Interpreter entwickelt werden, der den compilierten Code "übersetzt"? Wie lauffähig ist der rübergespielte Code, gibt es irgendwelche Einschränkungen bei der Programmierung in Codesys? (Verwendung von bestimmten Datentypen nicht möglich?) Was für Lizenzen werden für den Controller benötigt? Vielen Dank im Voraus Sebastian
Last updated: 2024-01-03
Post by ewi04 on Recipe Manager - RecipeManCommands, load & write wrong values, Bug?
CODESYS Forge
talk
(Post)
Hello, according to Codesys, the problem should be solved with version 4.3.0.0. After the update to version 4.3.0.0 I had the problem that the recipes weren’t saved correctly, but loading was okay. Return to the version 4.2.0.0 didn’t change the behavior. Strange… So I uninstalled the update, cleaned the project and built it new. The known behavior of version 4.2.0.0 was back. Update to version 4.3.0.0, clean and build it new, it works. Even with version 4.2.0.0. Strange, but okay. Notice: ManCommands.LoadRecipe() no longer writes into the PLC. Just as it should be. As of now, I can use the new version.
Last updated: 2024-01-05
Post by eschwellinger on Zielsystem stimmt nicht mit dem verbundenen Gerät überein
CODESYS Forge
talk
(Post)
na ja es gibt halt einfach die Möglichkeiten: 1. Man installiert Raspberry PI OS 32Bit -> dann geht PI SL und PI MC Multicore als Target 2. Man installiert Raspberry PI OS 64Bit dann muss es PI64Bit sein falls der Übersetzungsfehler nicht in einer Bibliothek ist (die du vielleicht nicht ändern kannst) https://faq.codesys.com/pages/viewpage.action?pageId=128253958 Hier der Hinweis was man tun muss das dein IEC Code für 32Bit als auch 64Bit Targets funktioniert Also entweder zurück auf Raspberry PI OS 32 Bit: nur zur Info noch was im Config file steht für welche Plattform/Produkt [CmpRasPi] Architecture=aarch64 (-> 64Bit PI) oder Architecture=armv7l (-> PI MC Multicore) oder Architecture=armv6l (-> PI SL Single Core)
Last updated: 2024-03-11
Post by mp9876 on Device User Logon
CODESYS Forge
talk
(Post)
Following up on the invalid user authentication on the target Not 100% sure what the problem was but following my post I managed to create an administrator level user. Then my next issue was that I could not connect to the device. I might have flipped the device from a 64 bit version to a 32 bit version so I did UPDATE DEVICE back to the 64 bit version; still could not connect somehow. Then I did two things at the same time that fixed my problem: Wiped the Codesys Control Win 64 bit version and installed the 32 bit version Installed latest Codesys Control Win V3.5 SP20 (released today) I wish I knew which one of these actions fixed the problem but at least the problem is solved. Hoping this post may help someone one day
Last updated: 2024-03-19
Post by reinier-geers on License problem gateway
CODESYS Forge
talk
(Post)
Epis doesnt want Softmotion. I thought it was about the price. If it was possible it would be working already and i dont need an extra licence. Thats the problem of codesys. The software is running but hangs on its license. Epis made it posible to see the stick. I can see the license. Softmotion is there from 3.5.14.Xx Like is said And Motion control is alrady posible 15 year ago. And i only need a Sync of 2 drives. I want a good solution not a refund. Dont point to the manufacturer. The software is made by 3s not by epis .
Last updated: 2024-04-29
Post by salvadegianluca on SysPlcCtrl23 and C0338: The library 'cmperrors interfaces, 3.5.5.0 (system)' is supported just in 32 bit applications
CODESYS Forge
talk
(Post)
Good afternoon to everyone; I'm stuck with this error and I don't know how to get out from it... I tried several time googling for alternative systems to control the PLC applications and resets but without success. I would like to realize the possibility to reset the CPU and to start/stop the applications as it was possible with the SysPlcCtrl23, but this library is no longer supported in 64 bit systems and it seems due to the cmperrors interfaces sub library that was included in the above said one. Someone found a work around for this issue?
Last updated: 2024-06-14
Post by salvadegianluca on SysPlcCtrl23 and C0338: The library 'cmperrors interfaces, 3.5.5.0 (system)' is supported just in 32 bit applications
CODESYS Forge
talk
(Post)
Good afternoon to everyone; I'm stuck with this error and I don't know how to get out from it... I tried several time googling for alternative systems to control the PLC applications and resets but without success. I would like to realize the possibility to reset the CPU and to start/stop the applications as it was possible with the SysPlcCtrl23, but this library is no longer supported in 64 bit systems and it seems due to the cmperrors interfaces sub library that was included in the above said one. Someone found a work around for this issue?
Last updated: 2024-06-14
Post by salvadegianluca on SysPlcCtrl23 and C0338: The library 'cmperrors interfaces, 3.5.5.0 (system)' is supported just in 32 bit applications
CODESYS Forge
talk
(Post)
Good afternoon to everyone; I'm stuck with this error and I don't know how to get out from it... I tried several time googling for alternative systems to control the PLC applications and resets but without success. I would like to realize the possibility to reset the CPU and to start/stop the applications as it was possible with the SysPlcCtrl23, but this library is no longer supported in 64 bit systems and it seems due to the cmperrors interfaces sub library that was included in the above said one. Someone found a work around for this issue?
Last updated: 2024-06-14
Post by salvadegianluca on SysPlcCtrl23 and C0338: The library 'cmperrors interfaces, 3.5.5.0 (system)' is supported just in 32 bit applications
CODESYS Forge
talk
(Post)
Good afternoon to everyone; I'm stuck with this error and I don't know how to get out from it... I tried several time googling for alternative systems to control the PLC applications and resets but without success. I would like to realize the possibility to reset the CPU and to start/stop the applications as it was possible with the SysPlcCtrl23, but this library is no longer supported in 64 bit systems and it seems due to the cmperrors interfaces sub library that was included in the above said one. Someone found a work around for this issue?
Last updated: 2024-06-14
Post by salvadegianluca on SysPlcCtrl23 and C0338: The library 'cmperrors interfaces, 3.5.5.0 (system)' is supported just in 32 bit applications
CODESYS Forge
talk
(Post)
Good afternoon to everyone; I'm stuck with this error and I don't know how to get out from it... I tried several time googling for alternative systems to control the PLC applications and resets but without success. I would like to realize the possibility to reset the CPU and to start/stop the applications as it was possible with the SysPlcCtrl23, but this library is no longer supported in 64 bit systems and it seems due to the cmperrors interfaces sub library that was included in the above said one. Someone found a work around for this issue?
Last updated: 2024-06-14
Post by salvadegianluca on SysPlcCtrl23 and C0338: The library 'cmperrors interfaces, 3.5.5.0 (system)' is supported just in 32 bit applications
CODESYS Forge
talk
(Post)
Good afternoon to everyone; I'm stuck with this error and I don't know how to get out from it... I tried several time googling for alternative systems to control the PLC applications and resets but without success. I would like to realize the possibility to reset the CPU and to start/stop the applications as it was possible with the SysPlcCtrl23, but this library is no longer supported in 64 bit systems and it seems due to the cmperrors interfaces sub library that was included in the above said one. Someone found a work around for this issue?
Last updated: 2024-06-14
Post by pernockham on Unable to deploy "Control for Linux SL 4.18.0.0"
CODESYS Forge
talk
(Post)
The option to update "Control for Linux SL" is not shown in the "deploy control SL tool", I can see and update the gateway but not the control (3.5.21 SP4). Has the way to update control SL changed? In the process of fault finding I removed the control SL entirely from my target, then I had to revert to version 3.5.21.0 SP 1 to re-install "Control SL 4.17.0.0". So I thought it was just a matter of using SP1 to update also to 4.18.0.0, but after installing the files for 4.18.0.0 in the SP1-version, the behavior was identical to SP4, ie no Control for Linux SL shown in the deploy tool.. See screenshots.