Search talk: Object reference not set to an instance of an object

 
<< < 1 .. 123 124 125 126 127 .. 313 > >> (Page 125 of 313)

Post by codesysjupiter on Could not be resolved - Library error CODESYS Forge talk (Post)
I tried. but not work.
Last updated: 2024-04-13

Codesys installation package fails because not signed CODESYS Forge talk (Thread)
Codesys installation package fails because not signed
Last updated: 2024-04-18

GPIOs not running with Raspberry Pi 4 (and SPI connection) CODESYS Forge talk (Thread)
GPIOs not running with Raspberry Pi 4 (and SPI connection)
Last updated: 2024-05-06

Codemeter log error: API Error 200 (ENTRY NOT FOUND) occurred! CODESYS Forge talk (Thread)
Codemeter log error: API Error 200 (ENTRY NOT FOUND) occurred!
Last updated: 2024-05-08

Licensing info not available (WAGO PFC200 + Codesys V3) CODESYS Forge talk (Thread)
Licensing info not available (WAGO PFC200 + Codesys V3)
Last updated: 2024-06-10

C0077 on one machine but not another CODESYS Forge talk (Thread)
C0077 on one machine but not another
Last updated: 2024-06-11

Tripod rotary coordinate is not correct with right hand rule CODESYS Forge talk (Thread)
Tripod rotary coordinate is not correct with right hand rule
Last updated: 2024-06-23

CODESYS OPC UA Security: HMI Client Not Receiving Server Certificate CODESYS Forge talk (Thread)
CODESYS OPC UA Security: HMI Client Not Receiving Server Certificate
Last updated: 2026-01-06

CODESYS OPC UA Security: HMI Client Not Receiving Server Certificate CODESYS Forge talk (Thread)
CODESYS OPC UA Security: HMI Client Not Receiving Server Certificate
Last updated: 2026-01-06

Axis directions in CNC editor not using right-hand rule? CODESYS Forge talk (Thread)
Axis directions in CNC editor not using right-hand rule?
Last updated: 2026-01-08

"Distributed clocks are not synchronized, Rea time problem on hardware" ? CODESYS Forge talk (Thread)
"Distributed clocks are not synchronized, Rea time problem on hardware" ?
Last updated: 2026-01-09

Smooth path is not working with SMC_NCInterpreter CODESYS Forge talk (Thread)
Smooth path is not working with SMC_NCInterpreter
Last updated: 2026-03-27

Codesys 3.5.21.3 add Library search not work CODESYS Forge talk (Thread)
Codesys 3.5.21.3 add Library search not work
Last updated: 2026-05-26

Persistence Manager does not save alphabetically first value CODESYS Forge talk (Thread)
Persistence Manager does not save alphabetically first value
Last updated: 2026-08-12

The selected container ... does not fit your ticket CODESYS Forge talk (Thread)
The selected container ... does not fit your ticket
Last updated: 2026-02-07

Post by eschwellinger on Persistence Manager Backup CODESYS Forge talk (Post)
you need at them moment a download once (for the configuration files generated including addresses) then stop the plc - exchange the persistence file ( without the config file) This will be improved to 3.5.18.6 and 3.5.20.0. (possible then to generate offline bootproject including full persistenmanager files) - this is if you have not 100% the same bootapplication on the devices. In case you copy the whole Application (PLCLogic) directory it should work out of the box - but only with 100% same bootprojects as mentioned above. By the CODESYS Automation Server would help solve this too.
Last updated: 2023-10-19

Post by esther on subdevicesCollapsed attribute in deviceDescriptor CODESYS Forge talk (Post)
I was trying to use subdevicesCollapsed attribute in device descriptor in order to not expand the subdevices when a new device with subdevices is inserted in the device tree. I use this as follows:<fixed subdevicescollapsed="true">. But it seems it doesn`t work. I am ussing Codesys v3.5 SP16 Patch4. Is anything wrong with this? Or am I mistaken with the use of this attirbute?</fixed>
Last updated: 2025-10-01

Post by josephbourgeois on Tracking out product CODESYS Forge talk (Post)
Hi everyone! I synchronize the operation of the tripod and the conveyor. I have a problem with the product tracking algorithm on the conveyor (PCS_1). Sometimes I need to stop tracking a product on command without completing the operation. I do this using MC_GroupStop. But when I need to start moving in WCS again (using fb movelinearabsolute), I get a tripod kinematics error - SMC_CP_INVALID_ORIENTATION (Invalid orientation (non-orthonormal matrix or non-unit quaternion, internal error)). MC_ResetGroup does not help. What could be the problem? Has anyone encountered this?
Last updated: 2024-02-05

Post by josephbourgeois on tracking out product CODESYS Forge talk (Post)
Hi everyone! I synchronize the operation of the tripod and the conveyor. I have a problem with the product tracking algorithm on the conveyor (PCS_1). Sometimes I need to stop tracking a product on command without completing the operation. I do this using MC_GroupStop. But when I need to start moving in WCS again (using fb movelinearabsolute), I get a tripod kinematics error - SMC_CP_INVALID_ORIENTATION (Invalid orientation (non-orthonormal matrix or non-unit quaternion, internal error)). MC_ResetGroup does not help. What could be the problem? Has anyone encountered this?
Last updated: 2024-02-05

Post by andrej on POU - Access to runtime CODESYS Forge talk (Post)
Hello all, when creating a POU, the Codesys IDE allows the setting "Enable System Call" (in the Settings, Property -> Build), see picture. The name suggest, that runtime functionalities i.e. functions of codesyscontrol such as "stop plc" etc. can be directly called. I tried various approches without success, the following does, unsurprisingly not work. FUNCTION accessRTE: BOOL; ****************************** codesyscontrol.stop(); Can you please tell me how I can make a system call to codesyscontrol from a POU. Or could you provide me with a use case for this setting. Many thanks for your feedback and kind regards Andrej
Last updated: 2024-03-02

Post by hjohnson123 on Automatically selecting a visualization element CODESYS Forge talk (Post)
I'm looking to automatically select a text field element in my visualization. I'm not sure if this is possible, as I don't know how to get the data on specific elements. I am wanting automatic selection of the text field, as I am using a keyboard-input barcode scanner, which should always input the barcode into the text field whenever a barcode is scanned. Does anyone know if this can be done?
Last updated: 2024-05-21

Post by rabaggett on No Visu on RasPi CODESYS Forge talk (Post)
Hello, I have been having trouble getting a visualization to show up on the RasPi. I have previously used both WAGO touchscreen and Windows ControlWin and had no trouble. The visu does not show on the Raspi screen on start of the program and attempts to view in a browser both on the Raspi (Chromium) and from my laptop (Brave,Chrome,Firefox) running Codesys development fail. The visu shows correctly in Codesys development when online. (Win 11) The control code that is active is operating correctly. Raspi Codesys runtime is licensed. What am I missing? Thanks!
Last updated: 2024-06-20

Post by davidf on Error trying to activate the demo Git licence CODESYS Forge talk (Post)
The CodeMeter Control Center log shows the following: 2024-10-11 21:02:13: Entry (6000437:8747) not found - Event WB0200 (ENTRY NOT FOUND), Request IP-Address local(IPV4) (SID 0xc079 / 0x00) with StationShare Mode 2024-10-11 21:02:13: API Error 200 (ENTRY NOT FOUND) occurred!
Last updated: 2024-10-11

Post by daniel on SysFileOpen not working CODESYS Forge talk (Post)
Hello, I have the same problem now with 3.5.20 Patch 3. Normally it works if I ad in CODESYSControl.cfg: [SysFile] ForceIecFilePath=0 (This told me codesys last time) I try to use the placeholders but without success. Something special is that the Files are not in C:. The Plc Configuration Path is not as usual C:\ProgrammData\CODESYS\CODESYSControlRTEV3\, it's E:\Control.
Last updated: 2024-10-23

Post by s1ack on Request a dark mode for CODESYS CODESYS Forge talk (Post)
and other colors have to be licensed? Introducing Code-Based Licensing Code Basic S: White text w/ grey background (ST only) Code Basic M: White text w/ dark gray background (ST Only) Code Basic L: White test w/ black background (ST Only) Code Standard S: 2 Colors of light syntax highlight colors w/ black background. (ST Only) Code Standard M: 4 Colors of light syntax highlight colors w/ black background. (ST only) Code Standard L: 6 Colors of light syntax highlight colors w/ black background. (ST only) Code Performance S: 2 Colors of light syntax highlight colors w/ user definable background. (Entire IDE) Code Performance M: 4 Colors of light syntax highlight colors w/ user definable background. (Entire IDE) Code Performance L: 6 Colors of light syntax highlight colors w/ user definable background. (Entire IDE) You get the gist... I used to be a big fan of CoDeSys. Recent re-entry after 5 years away, not so much.
Last updated: 2024-11-15

<< < 1 .. 123 124 125 126 127 .. 313 > >> (Page 125 of 313)

Showing results of 7802

Sort by relevance or date