Post by jami on Reading multiple lines from csv file
CODESYS Forge
talk
(Post)
Hello, i am trying to read multiple lines from csv file with caa file library and oscat. I have wrote 7 lines in the csv with separation '$R$L'. In my "extracting values" part I check line feeds and chars. After that I convert my buffer to string with oscat but I'm only able to read the first line from the csv. No matter if I even change start position where I start converting the buffer, I only get the first line. Here's my code for the reading and extracting value parts: 4: (*Reading the file*) fileread.hFile := filehandle; fileread.pBuffer := ADR(buffer); filesize1:=SIZEOF (buffer); fileread.szbuffer:=filesize1; fileread.udiTimeOut := 100000; fileread(xExecute := TRUE); IF fileRead.xDone THEN iFilesize:=TO_INT(fileread.szSize); writestate:=3; fileRead.xExecute := FALSE; END_IF 5: (*Extracting values*) //here i check the number of line feeds and chars. It works WHILE i < ifilesize DO c:=buffer[i]; IF c= 10 THEN IF lineindex<=99 THEN lineIndex := lineIndex + 1; END_IF ELSIF c <> 13 THEN IF charIndex <= 1000 THEN charIndex := charIndex + 1; END_IF END_IF i := i + 1; END_WHILE // Here i convert the buffer to string and transfer it to filelines:ARRAY[0..99] of string[254]. trig(CLK:=BUTTON); IF trig.Q THEN fileLines[i2]:=oscat_basic.BUFFER_TO_STRING(PT:=ADR(buffer), Size:=TO_UINT(fileread.szBuffer), start:=TO_UINT(bufferStart), stop:=TO_UINT(filesize1)); i2:=i2+1; bufferstart:=bufferstart+80; END_IF If anyone has idea how to read multiple lines, it would be nice. Even if you have example codes that work, that would help a lot.
Last updated: 2025-07-18
Post by timvh on Execute Codesys Tests with python
CODESYS Forge
talk
(Post)
If you want to use the Test Manager, I prefer to start all the tests through the scripts of this manager. So open from there the projects, load it and run it. If you also want to use Python scripts to access CODESYS functionality, while executing a Test Manager script, then also start them from the Test Manager commands.
Last updated: 2025-07-23
Post by eschwellinger on Codesys Virtual control SL
CODESYS Forge
talk
(Post)
Hi, which CODESYS Version are you using exactly? Either update to 3.5.21.x if you are on 3.5.20.x if not - add a more secure pw. Seems that on adding the login credentials it is mandatory in 4.16.0.0 -to have complianct to password policy seems a bug that the message not occure.
Last updated: 2025-08-06
Post by williamjmak1 on Current Visu name without Current Visu Variable
CODESYS Forge
talk
(Post)
Hello everyone, I was just wondering if anybody knows if there's a way to pull the string name of the current visualization without using the current visu variable. I'm working on a project where we don't want web clients to change the current visualization on the HMI of the machine. Thanks!!
Last updated: 2025-08-07
Post by raamkumar on exple1
CODESYS Forge
talk
(Post)
```structured text VAR bStartButton : BOOL; // Start button input bStopButton : BOOL; // Stop button input bMotorRunning : BOOL := FALSE; // Motor running status END_VAR // Motor control logic IF bStartButton AND NOT bMotorRunning THEN bMotorRunning := TRUE; // Start motor END_IF; IF bStopButton THEN bMotorRunning := FALSE; // Stop motor END_IF; // Output to motor driver (replace with your actual output) // Assume 'qMotor' is a boolean output to the motor driver. qMotor := bMotorRunning;
Last updated: 2025-08-23
Post by arjunk on How to correctly create a device descriptor (.devdesc.xml) for a custom Linux ARM64 PLC in CODESYS 3.5.21.20?
CODESYS Forge
talk
(Post)
Hi, Iβm evaluating CODESYS for our devices. If I buy a standard runtime and the Toolkit, can I create a custom device descriptor so users can select my device (instead of just βCODESYS Control for Linux ARM64 SLβ) when starting a new project? Has anyone done this or know if itβs possible? Thanks!
Last updated: 2025-10-07
Post by scarter on Import/Export PLCOpen xml Task Configuration
CODESYS Forge
talk
(Post)
I'm Having the same issue. If I highlight PLC Logic and import it erases everything else and replaces the Task config. If I highlight the Application I get the same result. Simple manual fix is click and drag the task config onto the origional Application, and delete the second one. Easy fix but not the expected result of importing task config.
Last updated: 2024-01-17
Post by alexgooi on How to protect library project?
CODESYS Forge
talk
(Post)
Hi aniket-b, If you save the library as a compiled library you are not able to see the source code. When the end user tries to view inside the object, CODESYS will give a notification that the source code is missing, see attachment. In short if you don't send the source code, it will not show.
Last updated: 2024-01-25
Post by ferrim on IEC 61499
CODESYS Forge
talk
(Post)
Hello otdeveloper, I am very interested in this topic. I have been dedicated to IEC 61499 for some time and I would like to understand if the time has come to adopt it in the real world of automation or if it will continue to fill up research papers only.
Last updated: 2024-02-09
Post by manuknecht on High Cycle Times for SoftMotion_PlanningTask when using AxisGroup
CODESYS Forge
talk
(Post)
Hi, thanks a lot for the response. I did check all these parameters, but if the PlanningTask takes up to 60 ms, I can't increase the Buffer to such values. I contacted the Codesys support with a projectarchive. Let's see if they can help. Thanks again for your great support!
Last updated: 2024-03-22
Post by hanoues on Holding brake release
CODESYS Forge
talk
(Post)
I've tried using the SMC3_BrakeControl function block to control the brake, but unfortunately, it's not functioning as expected. Despite setting the appropriate parameters and inputs, the brake control does not operate correctly. Any insights or suggestions on resolving this issue would be greatly appreciated. STATE_MANUAL.UNLOCK_BRAKE: IF Button_release_brake THEN GVL.drum1_Control_Brake:=TRUE; FBA.T11_ContBrake.bExecute := TRUE; GVL.manual_state := STATE_MANUAL.WAIT_FOR_BRAKE_RELEASE; END_IF STATE_MANUAL.WAIT_FOR_BRAKE_RELEASE: IF FBA.T11_ContBrake.bDone THEN FBA.T11_ContBrake.bExecute := FALSE; GVL.manual_state := STATE_MANUAL.WAIT_START_BUTTON; END_IF
Last updated: 2024-04-08
Post by timvh on Change the Opening Position of the Dialog using VU.FbOpenDialog
CODESYS Forge
talk
(Post)
Probably best to call the FB continuously. So something like this could solve it: IF xOpenLatchSettingDialog THEN xOpenLatchSettingDialog := FALSE; fbOpenLatchSettingsDialog.xExecute := TRUE; END_IF IF fbOpenLatchSettingsDialog.xDone OR fbOpenLatchSettingsDialog.xError THEN fbOpenLatchSettingsDialog.xExecute := FALSE; END_IF TopLeftDialog.iX := 100; TopLeftDialog.iY := 23; fbOpenLatchSettingsDialog( itfClientFilter:= VU.Globals.OnlyTargetVisu, sDialogName:= 'visu_AlarmLatchSettings', xModal:= TRUE, pTopLeftPosition:= ADR(TopLeftDialog) );
Last updated: 2024-05-09
Post by rajesh008 on i can't declear the address in GVL - codesys SP19 Patch5
CODESYS Forge
talk
(Post)
The β_AB AT %IW0:word; β if i called the value then im getting this error. like below "the declartion of the variable with an address assignment cannot be used in a PRG or GVL with the attribute 'subsequent'" This is happening when the GVL is selected in Redundancy Configuration. if i un-select the address declaration is working fine
Last updated: 2024-05-13
Post by timvh on How to implement an interface (IElement)?
CODESYS Forge
talk
(Post)
See: https://forge.codesys.com/prj/codesys-example/element-collect/home/Home/ This contains an application "OnlineChangeSafeLinkedListExample". What you should do is create a new interface which has your "Priority" property. Then your FB should extend the base element function block and implement your own interface: E.g. FUNCTION_BLOCK MyElement EXTENDS COL.LinkedListElementBase IMPLEMENTS I_MyInterface Then the __QUERYINTERFACE does the magic to check if your "element" also implements your interface. Something like this: // Compares this element with itfElement. // Returns 0 if the elements are equal, < 0 if the element is less than itfElement, // > 0 if the element is greater than itfElement. // This method will be called from sorted collections (e.g. |COL.SortedList|) to sort the elements. // IMPORTANT: The underlying value to be compared with MUST NOT be changed during the lifecycle of the object. METHOD ElementCompareTo : INT VAR_INPUT (* The element to compare*) itfElement : COL.IElement; END_VAR VAR itfIntElement : I_MyInterface; xResult : BOOL; END_VAR // We use integer iInt1 for sorting. xResult := __QUERYINTERFACE(itfElement, itfIntElement); IF xResult THEN IF iInt1 < itfIntElement.Priority THEN ElementCompareTo := -1; ELSIF iInt1 > itfIntElement.Priority THEN ElementCompareTo := 1; ELSE ElementCompareTo := 0; END_IF ELSE ElementCompareTo := -1; END_IF
Last updated: 2024-07-22
Post by jari-koivuluoma on Problem trying Net Base Services 3.5.15.0 TCP connection
CODESYS Forge
talk
(Post)
I have a need to send messages between 2 PLCs and I cant use network variables (because of size limit) so I tried writing this simple test program. This seems to work fine. I can send messages back and forth when a first "Start server" and then "Connect client". See the attached image. However, if I disconnect the client by setting ClientConnect to false and try to re-connect then the TCP_Client just gives me TIMEOUT error. When I stop and start the server again, then Im able to reconnect. How is this supposed to work? Why reconnecting wont work. There is not other way of disconnecting the client than setting xEnable of the TCP_Client to false. This is just a testing program and I will try it on 2 seperate devices once this works. PROGRAM PLC_PRG VAR CONSTANT mySize : UDINT := 255; END_VAR VAR Server: NBS.TCP_Server; ServerIpStr: STRING := '127.0.0.1'; ServerIP: NBS.IP_ADDR; ServerPort: UINT := 50000; ServerConnection: NBS.TCP_Connection; Client: NBS.TCP_Client; ServerRead: NBS.TCP_Read; ServerWrite: NBS.TCP_Write; ServerSend: STRING(mySize); ServerReceive: STRING(mySize); ServerConnect: BOOL; bServerSend: BOOL; IP: NBS.INADDR; ConnectedClientIP: STRING; ClientPort: UINT := 50000; ClientIpStr: STRING := '192.168.1.49'; ClientIP: NBS.IP_ADDR; ClientRead: NBS.TCP_Read; ClientWrite: NBS.TCP_Write; ClientSend: STRING(mySize); ClientReceive: STRING(mySize); ClientConnect: BOOL; bClientSend: BOOL; Error: BOOL; Message: BOOL; END_VAR // Server ServerIP.sAddr := ServerIpStr; Server( ipAddr := ServerIP, uiPort := ServerPort ); ServerConnection( xEnable := Server.xEnable, hServer := Server.hServer, ); IP := ServerConnection.IPAddress; ConnectedClientIP := F_Concat7( BYTE_TO_STRING(IP.S_un_b.s_b1),'.', BYTE_TO_STRING(IP.S_un_b.s_b2),'.', BYTE_TO_STRING(IP.S_un_b.s_b3),'.', BYTE_TO_STRING(IP.S_un_b.s_b4)); ServerRead( xEnable := ServerConnection.xActive, hConnection := ServerConnection.hConnection, szSize := SIZEOF(ServerReceive), pData := ADR(ServerReceive) ); IF ServerRead.xReady AND ServerRead.szCount > 0 THEN Message := TRUE; END_IF IF ServerRead.eError > 0 THEN Error := TRUE; END_IF ServerWrite( xExecute := ServerConnection.xActive AND bServerSend, hConnection := ServerConnection.hConnection, szSize := LEN(ServerSend)+1, pData := ADR(ServerSend) ); IF ServerWrite.xDone THEN bServerSend := FALSE; END_IF IF ServerWrite.eError > 0 THEN Error := TRUE; END_IF // Client ClientIP.sAddr := ClientIpStr; Client( xEnable := ClientConnect, ipAddr := ClientIP, uiPort := ServerPort, udiTimeOut := 10000000 ); ClientRead( xEnable := Client.xActive, hConnection := Client.hConnection, szSize := SIZEOF(ClientReceive), pData := ADR(ClientReceive) ); IF ClientRead.xReady AND ClientRead.szCount > 0 THEN Message := TRUE; END_IF IF ClientRead.eError > 0 THEN Error := TRUE; END_IF ClientWrite( xExecute := Client.xActive AND bClientSend, hConnection := Client.hConnection, szSize := LEN(ClientSend)+1, pData := ADR(ClientSend) ); IF ClientWrite.xDone THEN bClientSend := FALSE; END_IF IF ClientWrite.eError > 0 THEN Error := TRUE; END_IF
Last updated: 2024-10-03
Post by ojz0r on Assignment Efficiency - Repetitive Assignment vs IF statement
CODESYS Forge
talk
(Post)
Its important that you know the difference between the two. Example 1: Coils[0] := Coils[0] OR (Buttons[0] AND Sensors[0] > 6); In this case the statements will be evaluated every scan and result in either true or false for Coils[0]. Example 2: IF NOT Coils[0] AND Buttons[0] AND (Sensors[0] > 6) THEN Coils[0] := TRUE; END_IF In this example Coils[0] will latch the result in a true evaluation, if you want it to behave the same way as example 1 then you need to do it like example 3 below: IF NOT Coils[0] AND Buttons[0] AND (Sensors[0] > 6) THEN Coils[0] := TRUE; ELSE Coils[0] := FALSE; END_IF However back to the real question. There is no problem using either example 1 or example 3, if im not requiring a latch i usually go with example 1 as it is more compact.
Last updated: 2025-03-07
Post by alexgooi on Modbus writing on value change
CODESYS Forge
talk
(Post)
Hi Duvan, You could make this in 1 single object (FB), Indeed don't use a function for this beacuse you need some memory to keep the old value. For i := 0 TO 200 BY 1 DO //Check if the value has been changed IF Old_Value[i] <> Value[i] THEN //Set the trigger to TRUE Trigger[i] := TRUE; Old_Value[i] := Value[i]; END_IF END_FOR If you define the Value array as an In_Out and the Trigger as an In_Out you arn't claiming any aditional memory to your system. You ofcourse then need to add some code arround it that does something with the trigger and writes it back to FALSE again. If you want more flexability you also could use pointers instead of using the IN_OUT FOR i := 0 TO 200 BY 1 DO address := address_Input + i * SIZEOF(*Put type here); IF Address^ <> Old_Value[i] THEN Trigger[i] := TRUE; Old_Value[i] := Address^; END_IF END_FOR
Last updated: 2024-04-02
Post by salvatorethomas on Port instantiation of serial interface in WAGO PLC using Modb_L05.lib in CoDeSys v2.3
CODESYS Forge
talk
(Post)
Hi β good description of the problem. A few suggestions / questions that might help narrow this down: Since your first serial port (COM2) works fine but the second (COM4 + MODBUS_EXT_MASTER) never opens, check whether the two ports are truly independent β some WAGO modules share internal resources, so COM4 might conflict with other functions or modules. Make sure that the physical wiring and module configuration for the second port (baud rate, flow control, RS-485 vs RS-422, etc.) exactly match what the library expects β a mismatch in flow control or wiring could prevent port opening even if the LED signals seem OK. Try using a plain SERIAL_INTERFACE on COM4 first (like you did for COM2) without Modbus logic β if that opens, you know the hardware + port config is fine, so the issue is more likely with modb_L05.lib. If the port opens but Modbus still fails, enable debug/logging (if available) to inspect whether the port opening fails or the subsequent Modbus negotiation fails. If you like β I can share a minimal example project I used with WAGO + COM4 + Modbus that worked; you could adapt that to test your setup. Wacky Flip
Last updated: 2025-12-01
Post by timvh on Specify Input Configuration "OnDialogClosed" Action to only react to certain Dialogs
CODESYS Forge
talk
(Post)
What maybe helps is the Visu Dialog ST demo project: https://store.codesys.com/en/visu-dialog-st.html This has an application IECOpenDialog where dialogs are opened using the VU.FbOpenDialogExtended function blocks. The fbOpenConfigurationDialog call has a reference (interface) to the "close listener" FB of which it's method is automatically called when the dialog is closed. This way you can create specific function blocks for each dialog when it is closed and do what you want with the data that might have been changed.
Last updated: 2023-09-28
Post by konradkmiller on Variable assignments
CODESYS Forge
talk
(Post)
I have a snippet of code that I was given as a reference in ST. ** ModbusMasterRTU( xConnect:= TRUE, IPort:= IoConfigGlobals.COM1, // IoConfigGlobals.RS232485Interface, // COM1=Front Port / Serial module = Name of module in Devices structure I/O list udiBaudrate:= 19200, usiDataBits:= 8 , eParity:= WagoTypesCom.eTTYParity.None , eStopBits:= WagoTypesCom.eTTYStopBits.One , eHandshake:= WagoTypesCom.eTTYHandshake.None , ePhysical:= WagoTypesCom.eTTYPhysicalLayer.RS485HalfDuplex, xIsConnected=> xIsConnected , xError=> , oStatus=> , eFrameType:= WagoAppPlcModbus.eMbFrameType.RTU , tTimeOut:= T#1S, utQuery:= utQuery , xTrigger:= SEND, utResponse:= utResponse)** What is the meaning of => in this context?
Last updated: 2024-07-20
Post by andrebrandt on FB string and naming
CODESYS Forge
talk
(Post)
Hi all. I have a FB written in ST. FUNCTION_BLOCK NTC10k VAR_INPUT Syst:STRING; In:REAL; END_VAR VAR_OUTPUT Out:REAL; OTag:STRING; Out_St:Struct_NTC10K; END_VAR VAR Tag:STRING; InstanceName: STRING; Structure:Struct_NTC10K; END_VAR What i'm trying to do, is to pass data to structure. In structure i want to add a tag with systemnumber and sensorname. '320.001-RT401' In pou i use this RT401: NTC10k;, and tried this RT401: NTC10k(Tag:='RT401'); Anyone done this?
Last updated: 2024-09-26
Post by warrumungi on Opening a Dialog on a specific Client from ST
CODESYS Forge
talk
(Post)
Hi Thanks, Manuel, for providing this solution and insight. I too had exactly the same problem as you did. While I did implement a custom filter, I'd also like to point out what jinlee mentioned above...I see no reference to VU.PublicVariables.Clients.Current anywhere?? In my case I only needed to show a dialog on a "master" client, not all the clients, so I filtered by IP address to do this.
Last updated: 2024-11-05
Post by sturmghost on Visualization using methods and cyclic ST-calls
CODESYS Forge
talk
(Post)
I found a way to do it: You can use, for example, the text variable property of any visualization element and call a function in it. Example: Write a test POU as a function (FUN), like MyTestFun which need a boolean Variable as an input value. Now write into the text variable property: MyTestFun(bBooleanValue) Thats it. The function is called at each visu_task cycle.
Last updated: 2024-01-22
Post by nano on Is there any support for I2C on Raspberry Pi?
CODESYS Forge
talk
(Post)
hello jdj this question can be answered well with a pretty good forge documentation: https://forge.codesys.com/drv/io-drivers/doc/Generic/ u r also able to create in codesys directly an iec-code by using the i2c-interface as driver using the codesys ide and st depending on the stepperdriver, used in yΓΆur hat, its possible that an driver is already available in the device-repository. which mcp-device is used on the hat?
Last updated: 2024-03-01
Post by andy-yemm on Assertion Failed
CODESYS Forge
talk
(Post)
I had similar assertion failed error messages today. I am fairly new to Codesys. I tried using SFC for the first time, I usually use ST. Anyway I had errors in some of my transitions. I copied and pasted transition code and forgot to change the target of the code. I started getting lots of the assertion errors but now I have sorted out the problems and it compiles OK the assertion error messages seem to have stopped. There do not seem to be any other responses to your post, did you resolve your problem?
Last updated: 2024-03-19