Post by bossjosh21 on RevPi Connect RS485 CODESYS Forge talk (Post)
Hi Sir Kevin. May I know how you came up with this solution. Im a bit confused but I tried to put this. [SysCom] Linux.Devicefile=/dev/ttyRS48 (remember, no 5 at the end!) then set com port in codesys to 6. It also works for me but want to know where did you get this. Thank you.
Last updated: 2023-12-06

Post by eschwellinger on Raspberry Pi 5 CODESYS Forge talk (Post)
At the moment there are some changes on PI OS, which lead to problems with the PI5 an Pi runtime. I would use Arm SL or Arm 64 SL as runtime depending on which OS you have installed. just use the CODESYS Installer and deploy the the Arm runtime.
Last updated: 2024-07-12

Post by mmpl on Array to String CODESYS Forge talk (Post)
I would like to create one large JSON string from an array of objects, where each object contains a value. My current approach involves using a for loop and string concatenation, but with 20,000 elements in the array, this method takes almost 7 seconds and negatively affects the PLC scan time. Is there a more efficient way to accomplish this?
Last updated: 2024-07-18

Post by gepert on parker servo and position CODESYS Forge talk (Post)
Hello, I using codesys motion with Parker servo (without brake). In my application i use mc_moverelative. When i send new position motor moves. But when it arrives to the point it stops and does not hold the position. It means that i can easily move shaft by hand Should i somewere turn it on so motor keep position by torque (current)? Best regards Lukasz
Last updated: 2024-08-04

Post by maxsus on Visu Frame-configuration___text will not work CODESYS Forge talk (Post)
Hello I have a problem with the Frame-configuration. In the picture below you can see that I set the Editor Type to variable. If it would be text it would work, but it wasnt variable anymore. Thanks for your time. Sorry, my codesys is in German.
Last updated: 2024-08-20

Post by maxsus on Visu Frame-configuration___text will not work CODESYS Forge talk (Post)
Hello I have a problem with the Frame-configuration. In the picture below you can see that I set the Editor Type to variable. If it would be text it would work, but it wasnt variable anymore. Thanks for your time. Sorry, my codesys is in German.
Last updated: 2024-08-20

Post by damian177 on OPC UA Client CODESYS Forge talk (Post)
Hi, Today I ran OPC UA Client Example in 1.1.0.0 version. I opened example visualisation and I tried connected to my OPC UA Server. In first steps looks good but connection was terminate with error OpcUa_BadLicenseLimitsExceeded. I can't test OPC UA Client witohut CODESYS OPC UA Client SL license ? Regards
Last updated: 2024-08-30

Post by eschwellinger on RS485 CAN HAT to Cosesys CODESYS Forge talk (Post)
Hi if you add in (ttyAMA0 should fit to your HAT's device [SysCom] Linux.Devicefile.1=/dev/ttyAMA0 to /etc/CODESYSControl_Usr.cfg since 4.12.0.0 version /etc/codesyscontrol/CODESYSControl_Usr.cfg then access in CODESYS with Com1 should do it. Keep in mind that only adapters work (for RS485) which do determine the send/receive direction in hardware
Last updated: 2024-10-28

Post by jeroenaero on CodeSys Raspberry pi I2C driver not found CODESYS Forge talk (Post)
yes i took the library from another forum: https://forge.codesys.com/forge/talk/Runtime/thread/f1400b71b6/, it is made for the ads1115 but the ads1015 is almost the same device with same adresses i only changed the divide value of the analog value, because thats the only difference between the ads1115 and ads1015.
Last updated: 2024-11-07

Post by ellocco on Leitungsverzweigung mit einem existierenden Block (z.B. AND-Glied) zu verbinden CODESYS Forge talk (Post)
Is it possible under CODESYS V3.5 SP18, to connect a split (german Leitungsverzweigung) with an existing block (e.g. AND-module)? Or to connect the output of an existing block to the input of an existing block (e.g. OR-block)? Any ideas? P.S.: Sorry for the german title, I do not know how modify the title.
Last updated: 2024-11-07

Post by andrax on CodeSys Raspberry pi I2C driver not found CODESYS Forge talk (Post)
Ok, this is a test programme with ADS1115. It is currently configured for the TCA9548 muxboard. If you want to run the ADS1115 single, then change the settings to the default values: ‘Is Multiplex:’ False ‘Stage mux channel numbers:’ [0,0,0,0,0,0,0,0,0] It is also important that the libraries are installed correctly here. But should be in this project
Last updated: 2024-11-07

Post by andrax on CodeSys Raspberry pi I2C driver not found CODESYS Forge talk (Post)
I took a look at your project. First of all, a Raspbery Pi4 is installed. You must use the GPIOs_A_B(GPIOs B+/Pi2). The error ULINT can't be set to IDINT.... with your project as well. If I change your project to ‘CODESYS_Control_for_Raspberry_Pi_SL’ the error is gone.
Last updated: 2024-11-09

Post by andrax on CodeSys Raspberry pi I2C driver not found CODESYS Forge talk (Post)
Sorry, wrong expression. You have a 64bit system, so do I. You can also use the 64bit runtime, but most bib and commands are 32bit and are not properly supported. I had read somewhere that there are problems with I2C. That's why I recommend switching to PI_SL and using the correct gpio.
Last updated: 2024-11-09

Post by trusty-squire on Strange problem with the ‘MC_SetPosition’ function CODESYS Forge talk (Post)
Just a stab in the dark, but you might want to check the Dynamic Limits (accel, decel, velocity, jerk) in the Codesys SoftMotion device configuration, as well as checking similar limits on your servo drive? Are you seeing any errors, or does the MC_SetPosition FB get marked as complete?
Last updated: 2025-01-09

Post by teichhei on The selected container ... does not fit your ticket CODESYS Forge talk (Post)
After correspondence with Mr Schwellinger from Codesys the resolution for this was to uninstall the SL 4.14 and install SL 4.13 on the device. Once this was done the licensing worked as expected. I noted that the container then showed a Version 3.00 and not 0.00.
Last updated: 2025-01-11

Post by secundino on License CODESYS Forge talk (Post)
Good morning, I need to activate a CODESYS license on your website, as the computer where it was originally installed has been formatted. I have already sent two emails to store-support@codesys.com, but I have not received a response yet. Could you please assist me with this issue as soon as possible?
Last updated: 2025-02-20

Post by secundino on License CODESYS Forge talk (Post)
Good morning, I need to activate a CODESYS license on your website, as the computer where it was originally installed has been formatted. I have already sent two emails to store-support@codesys.com, but I have not received a response yet. Could you please assist me with this issue as soon as possible?
Last updated: 2025-02-20

Post by snguyen on Atomic and Shared memory? CODESYS Forge talk (Post)
Hi, I've read that you can perform Atomic instructions like AtomicReadLInt on variables. However, I'd like to know if this uses stdatomic internally. My main question is : Is it possible to share atomic types in shared memory with CodeSys. If so, what types should they be declared as? If not, are the atomic functions lock-free or does it use a mutex?
Last updated: 2025-04-15

Post by damian177 on Serialports in EdgeBox-RPI-200 CODESYS Forge talk (Post)
Hi, Two years ago i used EdgeBox-RPI-200 with Codesys and serial ports works fine. Now I try run the same application but only new runtime but serial ports doesnt works: I have two serial: /dev/ttyACM0 - RS485 /dev/ttyACM1 - RS232 and below configuration in my sudo nano /etc/CODESYSControl_User.cfg: [SysCom] Linux.Devicefile=/dev/ttyACM But it doesnt work. what can i do ?
Last updated: 2025-05-17

Post by eschwellinger on TargetVisu option missing in IDE CODESYS Forge talk (Post)
It is not needed to add Targetvisu connector - for using the TargetVisu for Linux. The reason is - TargetVisu for Linux is basically a remote TargetVisu which could connect to any CODESYS plc not only the loacal one - therefore only a Webvisu connector is needed to have it work. & it seems a bug with this anoying update proposal.
Last updated: 2025-08-23

Post by raamkumar on exple1 CODESYS Forge talk (Post)
```structured text VAR bStartButton : BOOL; // Start button input bStopButton : BOOL; // Stop button input bMotorRunning : BOOL := FALSE; // Motor running status END_VAR // Motor control logic IF bStartButton AND NOT bMotorRunning THEN bMotorRunning := TRUE; // Start motor END_IF; IF bStopButton THEN bMotorRunning := FALSE; // Stop motor END_IF; // Output to motor driver (replace with your actual output) // Assume 'qMotor' is a boolean output to the motor driver. qMotor := bMotorRunning;
Last updated: 2025-08-23

Post by gseidel on can not new a cam table in codesys V3.5 SP20 CODESYS Forge talk (Post)
Hi liai, is it possible, that SM3_Basic is missing in the library manager? (It should be inserted automatically when adding a Cam table, along with the other motion libs.) You can add it manually and see if that solves the compile errors. Best regards, Georg
Last updated: 2025-09-19

Post by as1984 on Codesys Control log "eventbuffer full" CODESYS Forge talk (Post)
Have you found a solution for this? Id be thankful for every hint. I have a controller with the same events in log and sometimes it crashes. Memory of the codesys3 task rises until the linux system kills the task because the controller runs out of memory.
Last updated: 2024-01-17

Post by rkohser on Python Script for Finding "Last saved with" Value CODESYS Forge talk (Post)
Hi jkilburn, I have the exact same issue and thought I would search a solution on this forum. I see you did not get any answer, did you find a solution on how to extract the last saved version of codesys from the project file ? Roland
Last updated: 2024-01-29

Post by dhumphries on WAGO PLC 200 750-8216 Ethernet connection to Codesys 3.5 CODESYS Forge talk (Post)
make sure the PLC and the programming PC have IP addresses that are on the same subnet, you'll have to know the default address of the PLC or you may need to connect to it with a special cable and use a software tool to set the IP address.