Post by leafy on Use third party actuator with IO-Link Master (IFM) CODESYS Forge talk (Post)
Hey there! I am currently doing a little automation project for uni. I am trying to integrate a control-valve-system (Buerkert AirLINE Field) in my IO-Link environment. With IFM sensors, I used their pre-built function blocks, but with this third-party device, i need to write my own function block. Thankfully, IFM provides a generic sensor-fb so I can write my own FB with "extends" and "super". So far, so good. I found the IODD and some other documentation and I thought I get how it works, but somehow can't really get it to work at all. From my understanding, i need to write data into the PDO-Array. But i get confused with the indices and subindices of IO-Link. I'll append the IODD and some screenshots of my project. There is an AOI for LogicXDesigner, but I can't use that in Codesys. I hope someone has integrated a IOL-device in Codesys before and can help me with this. Cheers leafy
Last updated: 2024-04-16

Post by leafy on Use third party actuator with IO-Link Master (IFM) CODESYS Forge talk (Post)
Hey there! I am currently doing a little automation project for uni. I am trying to integrate a control-valve-system (Buerkert AirLINE Field) in my IO-Link environment. With IFM sensors, I used their pre-built function blocks, but with this third-party device, i need to write my own function block. Thankfully, IFM provides a generic sensor-fb so I can write my own FB with "extends" and "super". So far, so good. I found the IODD and some other documentation and I thought I get how it works, but somehow can't really get it to work at all. From my understanding, i need to write data into the PDO-Array. But i get confused with the indices and subindices of IO-Link. I'll append the IODD and some screenshots of my project. There is an AOI for LogicXDesigner, but I can't use that in Codesys. I hope someone has integrated a IOL-device in Codesys before and can help me with this. Cheers leafy
Last updated: 2024-04-16

Post by plumper on License problem gateway CODESYS Forge talk (Post)
I have the same problem. Obtained new license without success. Codesys 3.5 SP 16, soft container. I would be grateful for quick help as we have to deliver equipment. Best regards
Last updated: 2024-04-16

Post by nano on Functional block CODESYS Forge talk (Post)
u can use internal variables by passing it thru setter/getter. thats the way to go. for that add it by rightclick on fb and create propertie
Last updated: 2024-04-17

Post by tomas111 on Text List Fallback Value CODESYS Forge talk (Post)
What version of codesys? Need to avoid in any specific element? Try writing %s in the text, it should work. Or better yet, attach a screenshot.
Last updated: 2024-04-17

Post by chir on SMC_REGULATOR_OR_START_NOT_SET issue CODESYS Forge talk (Post)
Hello everyone! I faced the error SMC_REGULATOR_OR_START_NOT_SET using InoProShop (Inovance IDE). This error occured then I enable MC_Power block. The output BUSY is TRUE constantly.. The description of this error in documentation - "Controller enable not done or brake applied". Maybe someone know how to solve this problem
Last updated: 2024-04-19

Post by fontrap on cmDongle Raspberry Pi issue CODESYS Forge talk (Post)
Hello mates, I'm working with CODESYS V3.5 SP20 on a Raspberry Pi and I use "Raspberry Pi MC SL" as device on the project. I've installed the Control Standard L (multicore) license on a Wibu System usb-Dongle (cmStick/4.50) that already had another license from another vendor. I follow the online activation procedure from CODESYS documentation. Raspberry Pi has already CodeMeter installed for the other license. When I plugin the dongle on Raspberry and start the Runtime from Raspberry Pi Update in CODESYS I receive the message that I'm on Demo mode because the license is missing. I double checked that the license is activated in the dongle, through the WebAdmin of CodeMeter and the second license runs properly without any issue. I have already try to change the dongle from HID to MSD device and backward but the the Runtime cannot recognize the Dongle. I have also try to stop and start the Runtime through CODESYS without success. Is there anything else I can do to fix this issue?
Last updated: 2024-04-22

Post by valenting on Problem with Licenced Software Metrics CODESYS Forge talk (Post)
Hi, I can't compile my code with SP20, but when I use the "read current metrics from device" with SP20 I get the following, with "not yet supported" for the visualization part Is it supposed to be like this ?
Last updated: 2024-04-24

Post by damian177 on Visualization - table element CODESYS Forge talk (Post)
Hi, In my application I use table elemnt with filled by STRING ARRAY. I would like to implement the following functionality : When I click on second row, that this row will be cleared. Anyone can help me?
Last updated: 2024-04-25

Post by reinier-geers on License problem gateway CODESYS Forge talk (Post)
By browser is not working. Tim suggestet to use Codesys and stick in the laptop. Thats working. But now with a stick with licence but no running motion.
Last updated: 2024-04-25

Post by alex2 on Codesys SVN CODESYS Forge talk (Post)
Thank you for your answer. So i assumed correctly... And yes thats pretty expensive... Having to pay that much only for SVN / Git. we will look for that.
Last updated: 2024-04-29

Post by yannick on Raspberry PI 5 not working CODESYS Forge talk (Post)
Thanks for your quick help. It's working until I do a reboot of the raspberry PI. After that it goes back to 2024-04-20. How's that possible?
Last updated: 2024-04-29

Post by k2saki on CNC Override speed. SMC_Interpolator.dOverride is working ? CODESYS Forge talk (Post)
Hello. I have a question about override of moving speed. I am testing G-Code in Simulation mode. I set SMC_Interpolator.dOverride <--- 0.5, 1.0, 2.0 when Interpolator is working But SMC_Interpolator.dVel(speed) did not changed at all. Am I missing something to take effect ?
Last updated: 2024-05-01

Post by hyet on IoDrvModbusTCP_Diag not defined when using MODBUS CODESYS Forge talk (Post)
Currently seeing the same issue here, with a project moved from 3.5.19. Diving into it too to see if i can find the cause
Last updated: 2024-05-01

Post by radekkoza on How to use GPIO (and IOT2000 IO-Module) with CODESYS Control for IOT2000 SL ? CODESYS Forge talk (Post)
Hi I have this question I can't find anywhere what pins Di3 and Di4 have all the rest work . I have a 10 input iot2000 card
Last updated: 2024-05-05

Post by radekkoza on How to use GPIO (and IOT2000 IO-Module) with CODESYS Control for IOT2000 SL ? CODESYS Forge talk (Post)
Hi I have this question I can't find anywhere what pins Di3 and Di4 have all the rest work . I have a 10 input iot2000 card
Last updated: 2024-05-05

Post by corriibme on Profinet IO-link master - IODD files CODESYS Forge talk (Post)
I am having the same problem right now. Could you please share more information if you were able to solve the problem?
Last updated: 2024-05-05

Post by radekkoza on How to use GPIO (and IOT2000 IO-Module) with CODESYS Control for IOT2000 SL ? CODESYS Forge talk (Post)
Hi I have this question I can't find anywhere what pins Di3 and Di4 have all the rest work . I have a 10 input iot2000 card
Last updated: 2024-05-05

Post by tama00 on GPIOs not running with Raspberry Pi 4 (and SPI connection) CODESYS Forge talk (Post)
Hello everyone, I have a working SPI connection (with transferExt) between a Raspberry master with Codesys and an ESP32 slave. I would also like to use a few GPIO pins. Is there a problem with using SPI AND GPIOs? Environment: Raspberry Pi 4+ with Raspian from Oct 23 Codesys V3.4 SP19 Patch 5 with Runtime Version 4.10.0.0 Device: GPIOs B+/Pi2 My problem: The status is displayed as “GPIOs : not running”. And also during mapping the message “The bus is not running. The values shown are perhaps not actual”. However, the variable changes that I make in my program are displayed under “Current Value”. In the Logic Analyzer, the pin toggles during transmission with small intervals of +-4us (seems to be a cyclical disorder, but I don't know where exactly it could be coming from). This applies to pins that I actually use (output) but also to the other GPIOs (not used). With GPIO 4, the line remains permanently high. Attached is a screenshot from the Logic Analyzer. Channel 1,3,5 were GPIO pin 26, 22, 17 Would be very grateful for help. Best regards
Last updated: 2024-05-06

Post by mxj262 on FB having single input but initialized with Array CODESYS Forge talk (Post)
Ok yes now the loop has stopped when I set sum to zero before the for loop. Why will it retain the sum value from the last call?
Last updated: 2024-05-06

Post by alex-wall on Network Variables not updating CODESYS Forge talk (Post)
This worked for me. I had four identical PLC's. Three of them worked just fine with 255.255.255.255 as the broadcasting address but the 4th would not update the variables. Changed it to 192.168.x.255 and everything worked.
Last updated: 2024-05-07

Post by stiller on OPC-UA ApplicationUri / ProductUri CODESYS Forge talk (Post)
Hello! Is there a way to change ApplicationUri and ProductUri of the OPC_UA server? I can not find any information about it. Does someone have a clue? Thank you in advance!
Last updated: 2024-05-10

Post by dalfaro21 on Softmotion not working with simulation mode CODESYS Forge talk (Post)
I have a KEB combivis studio software running codesys and I want to make some moves but softmotion is not working on my laptop I hope you can help me!
Last updated: 2024-05-12

Post by eschwellinger on Ethercat bus on Beckhoff CX with Codesys for Linux CODESYS Forge talk (Post)
yes I think you need to build the kernel drivers for the CCAT driver for the backplane ETC networkcard https://github.com/Beckhoff/CCAT/
Last updated: 2024-05-13

Post by kevinm on Data source and safety PLC CODESYS Forge talk (Post)
I am having the same trouble. However, if I change the Login Configuration settings to 'Type: Login using the credentials determined at runtime' then the Connection information continues as 'Connection state: Connecting' and 'Error information: OK'. There is no User Management on the source PLC.
Last updated: 2024-05-16