Post by manuknecht on High Cycle Times for SoftMotion_PlanningTask when using AxisGroup
CODESYS Forge
talk
(Post)
Hi, thanks a lot for the response. I did check all these parameters, but if the PlanningTask takes up to 60 ms, I can't increase the Buffer to such values. I contacted the Codesys support with a projectarchive. Let's see if they can help. Thanks again for your great support!
Last updated: 2024-03-22
Post by hwopereis on Codesys Control shutdown
CODESYS Forge
talk
(Post)
Hi, I'm experiencing this problem as well. Did the suggested combination resolve your issues in the end? If not, I can stop my efforts rolling back to these versions. I'm trying to get CC for RPi 4.8.0.0 installed on the device, but I can't find it after installing it through the packet manager.
Last updated: 2024-03-25
Post by adarsh on CAN Tags in Writing in PLC Error.
CODESYS Forge
talk
(Post)
Hi Folks, I have CAN Device Connected so I am able to read and write data at J1939 Manager. But unable to write the data from the PLC. Geeting the Following error while Writing from the Ladder Logic Diagram. Error:NO Valid Assignment Target How we can Rsolve this Problem
Last updated: 2024-04-02
Post by correo0269 on Problems with Raspberry Pi - IoDrvGPIO library
CODESYS Forge
talk
(Post)
I am trying to create a new proyect using the Raspberry Pi 4.11.0.0 package with Codesys 3.5 SP20, I am able to communicate with the Raspberry and start the runtime application but when I create a new proyect I have these errors. When opening the library manager of the proyect the library of the IoDrvGPIO is used so I dont really know whats happening.
Last updated: 2024-04-05
Post by dkugler on build (F11) / generate code using a python script file
CODESYS Forge
talk
(Post)
After a project is opened and I have done some changes, I want to start the build or code generating process by a python script file. After the build is done I a Windows sound/beep should appear. Anyone has an example or hint how the .py file has to look like? Thanks!
Last updated: 2024-04-10
Post by thomaspfrimmer on Can't import enums OnlineChangeOption / ResetOption
CODESYS Forge
talk
(Post)
Hello Jusito, Can you share your final code, please ? I tried to implement a similar feature (going online, doing the reset and the start). But I get a timeout on the reset/start when I'm testing the script. If you got something working, I would appreciate to see it.
Last updated: 2024-04-11
Post by phoward131 on Numpad decimal value requires leading zero
CODESYS Forge
talk
(Post)
I have noticed on the standard numpad dialog, if a user enters a purely decimal number (ie '.6'), the numpad will not accept the value but gives no indication. One must type a leading zero (ie '0.6') in order for it to work. Is there a way to correct this so that a user can just type the decimal value?
Last updated: 2024-04-30
Post by arslan on G Code Position Shifting
CODESYS Forge
talk
(Post)
Dear friends, I have a issue that. I would like to give a zero offset of any axis in G-Code by G54 from PLC code as below demonstration. N000 G00 X0 Y0 Z0 N010 G54 (offset from PLC) N020 G01 X0 Y0 Z0 . . How to fix it! BR
Last updated: 2024-05-02
Post by bryandimino on OPC Da Server Code Meter Issues after Enabling License
CODESYS Forge
talk
(Post)
I'm trying to get the OPC server setup on my machine and currently I'm not having luck. I went ahead and got my license setup. However when I go to run WinCoDeSysOPC.exe I get an error message that I don't have the code meter licenses installed. Does anyone have any ideas on how I can fix this issue?
Last updated: 2024-05-02
Post by andrej on Channel timeout CmpChannelMgr
CODESYS Forge
talk
(Post)
Hello, I use Codesys RTE 3.5.16.5. If I connect to the PLC I often get the following message: (see printscreen) 1. Channel timeout CMpChannelMgr. 2. Closing connection CmpChannelMgr. Can you tell me, what the meaning of this is? What does the number 1250030,1220020 resp. c400:0a0a:015a:0301 refer to? I could find any information in the online help. Thanks a lot.
Last updated: 2024-05-08
Post by stiller on OPC-UA ApplicationUri / ProductUri
CODESYS Forge
talk
(Post)
Thank you for your answer! I'm not sure, but it seems this is not what I am looking for. I attached three pictures. The first one is from the Codesys IDE. I use an Information Model to generate an OPC-UA server. I connected via UA-Expert, and there I see the URIs I would like to change.
Last updated: 2024-05-10
Post by walkercope on Ethercat bus on Beckhoff CX with Codesys for Linux
CODESYS Forge
talk
(Post)
Has anyone figured out a way to use the ethercat bus on a beckhoff CX using codesys running on linux? Using ethercat on the native NICs works fine but I get a "packet could not be sent" error when trying to scan the ethercat bus device. Errors and hardware in attached image.
Last updated: 2024-05-13
Post by micik on CAA File- FILE_OPERATION_DENIED error
CODESYS Forge
talk
(Post)
Hello, I'm trying to use FILE.Open to open file that exists in the given location. sFileName is formed from "Copy as path" in Windows. So I'm sure file exists and it is in the given location. And still, I get thiss denied error. What could be the problem here? Attached is a screenshot with current implementation.
Last updated: 2024-05-16
Post by xiaoyan on Generic EtherCAT slave
CODESYS Forge
talk
(Post)
Hello Well i need some basic advice. My protegoD drive is shown deactivated in the device tree. i can see its variables and other i/o in online mode but the device itself is deactivated. how can i address this issue. is there any configuration error.using ethercat link to connect to protegoD by Primo MC plc
Last updated: 2024-05-16
Post by mgengler on Recipe Manager - Not Creating Recipe Files
CODESYS Forge
talk
(Post)
Thanks for info... However, I changed the directory to: C:\ProgramData\CODESYS\CODESYSControlWinV3x64\58719825\PlcLogic\Recipes It still displays the content of this folder OK, however still will not write or read files. Is this the PLCLogic area you speak of? I also tried adding this path the the CodesysControl.cfg file. But still can't get it to work. Any additional direction would be appreciated!
Last updated: 2024-05-20
Post by eschwellinger on connect IDE to plc that uses modem ppp
CODESYS Forge
talk
(Post)
Which plc type is it? Easy connection is to install a Gateway on remote side - this is available for Windows and Linux devices Then just add a new Gateway in CODESYS (with the IP Adress of the remote device) -> then scan the plc via this new added Gateway
Last updated: 2024-05-21
Post by anonymous on Hi, I try to send and receive data using a UDP connection via SysSocket 3.5.17.0. While sending data works fine, I have problems with the receiving part. I am able to capture the received data of client side in wireshark But unable to capture it on the codesys
CODESYS Forge
talk
(Post)
Hi, I try to send and receive data using a UDP connection via SysSocket 3.5.17.0. While sending data works fine, I have problems with the receiving part.I am able to capture the data of client side in wireshark but i am unable to capture it in the codesys. Heres the below part of code of client side. PROGRAM POU_udpclient_program VAR istep : INT := 1;//step variable for state machine xStart: BOOL;// Flag to start the UDP protocol iecSocketId: syssocket_interfaces.RTS_IEC_HANDLE;//socket handle for receiving iecCreateResult: syssocket_interfaces.RTS_IEC_RESULT; ipAddr: syssocket.SOCKADDRESS;//Socket address structure for receiving sIpAddress : STRING := '192.168.0.2'; wPort: WORD:= 12346; iecConnectResult : syssocket_interfaces.RTS_IEC_RESULT;//connect paramters sDataRec : STRING[255];//Buffer for received data xiRecBytes : __XINT;//number of bytes received iecRecResult : syssocket_interfaces.RTS_IEC_RESULT;//receive data parameters iecCloseResult : syssocket_interfaces.RTS_IEC_RESULT; END_VAR syssocket.SysSockInetAddr(sIpAddress,ADR(ipAddr.sin_addr)); ipAddr.sin_family := syssocket.SOCKET_AF_INET; ipAddr.sin_port := syssocket.SysSockHtons(wPort); CASE istep OF 1: //create socket IF xStart THEN iecSocketId:= syssocket.SysSockCreate(syssocket.SOCKET_AF_INET,syssocket.SOCKET_DGRAM,syssocket.SOCKET_IPPROTO_IP,ADR(iecCreateResult)); IF iecSocketId = syssocket_interfaces.RTS_INVALID_HANDLE THEN xStart := FALSE; istep := 1; ELSE istep := 2; END_IF END_IF 2: //connect to socket server using setoption iecConnectResult := syssocket.SysSockSetOption(iecSocketId,syssocket.SOCKET_SOL,syssocket.SOCKET_SO_REUSEADDR,ADR(ipAddr),SIZEOF(ipAddr)); istep := 3; 3: //receive data xiRecBytes := syssocket.SysSockRecvFrom(iecSocketId,ADR(sDataRec),SIZEOF(sDataRec),0,ADR(ipAddr),SIZEOF(ipAddr),ADR(iecRecResult)); istep := 4; 4: //close socket iecCloseResult:= syssocket.SysSockClose(iecSocketId); xStart := FALSE; istep := 1; END_CASE
Last updated: 2024-06-03
Post by installwhat on Panasonic servo Softmotion project
CODESYS Forge
talk
(Post)
There are examples installed when you install codesys. they are located in C:\Program Files\CODESYS 3.5.19.50\CODESYS\CODESYS SoftMotion\Examples The examples won't be specific to your drive, though you haven't specified the exact drive. After you add the device to the ethercat master you can click on it and set pdo etc
Last updated: 2024-06-13
Post by rikher on Error: Too few outputs exixts for the box 'MemCopy' (minimum is 1).
CODESYS Forge
talk
(Post)
I am using MemCopy Function for this example: https://www.youtube.com/watch?v=DeTCT5Vyn28&t=482s It is from library WagoSysPlainMem. I want to use this for an MQTT example. However, Codesys is complaining the block does not have outputs. How to fix this?
Last updated: 2024-06-19
Post by kuegerls on SysProcessExecuteCommand2 and CANopen Device
CODESYS Forge
talk
(Post)
I have now conducted some tests. The problem occurs when the Python script establishes an OPCUA connection, even if I only establish the connection without reading or writing any data. Is there another way to exchange data between Python and CODESYS without having to put in a lot of effort?
Last updated: 2024-06-24
Post by xcqt on Oop best practice
CODESYS Forge
talk
(Post)
Hi all, I’m currently trying to improve my OOP structure in CODESYS and I’m looking for some input on how others approach this. I understand the basics like inheritance, interfaces, abstract FBs, methods, and properties, but I still struggle a bit with the overall architecture and what’s considered clean or scalable in bigger projects. As an example, I’m working on two different energy meter function blocks: FB_EnergyMeter_MQTT reads data from MQTT (strings) FB_EnergyMeter_Modbus reads data from Modbus (words) Both have their own Update() method and implement the same interface (something like IF_EnergyMeter). Later on, I’ll probably add more meter types, but they should all behave the same from the controller’s point of view. Now, there’s a FB_GridControl block that needs power data from these meters. I see two options here: Define the meter blocks inside FB_GridControl and call them directly (for example fbModbusMeter.UpdateModbus()). Keep the meter blocks outside and pass them into FB_GridControl as interface references, so the control block doesn’t know which specific type of meter it’s dealing with. Option 2 feels cleaner and more flexible to me, but I’m not entirely sure how to handle the data flow in that case. Should I pass the meter instance through an interface reference (REFERENCE TO IF_EnergyMeter)? Or is there a better way to link the external FBs to the control block? I’d like to hear how you structure this kind of setup or see an example from someone who has done something similar. EDIT: I think i need to do something like this fbModbusUpdateInput(wInput:= wWordValue); fbMqttUpdateInput(strInput:= strStringValue); IF bUseMqtt THEN Meter REF = fbMqttUpdateInput; ELSE Meter REF = fbModbusUpdateInput; END_IF fbControl.SetMeter(UsedMeter := Meter); Or am i thinking wrong? Thanks, Thomas
Last updated: 2025-10-16
Post by kaotic2499 on Upgraded Raspberry 2b to Raspberry 5, Trends Broken?
CODESYS Forge
talk
(Post)
Is there anyone who can assist me? ill just have to raise this as a bug with codesys otherwise. I see this as the only way foward. ill attempt a fresh install of RPI in the next day or two, but thats all i had previously so 🤷♂
Last updated: 2025-10-21
Post by salmawis on Advice on OOP hardware I/O code structure
CODESYS Forge
talk
(Post)
Call 10 FB instances. Connect Motor_1_Fault to the i_xHW_FaultDetected pin of FB 1, Motor_2_Fault to FB 2... By doing this, your FB will be flexible. The programming will be smooth like a perfect Drift Boss, instead of "hitting the wall" because it can't be reused!
Last updated: 2025-10-31
Post by seler on Custom button with output status
CODESYS Forge
talk
(Post)
Hi, Im struggle with making custom button. The idea is simple grey light bulb after touch (input var) it changes to yellow but shows output var status not switch status. So if light is physically on, switched by physical switch, bulb is also yellow. How to do it?
Last updated: 2025-11-18
Post by althafu on Codesys v 3.5 to factory IO
CODESYS Forge
talk
(Post)
I have been following the steps shown in the RealPars video to connect CODESYS with Factory I/O. The connection works correctly when I use Ladder Diagram, but when I try the same simple input–output logic in Structured Text, the simulation does not behave as expected. Has anyone experienced this issue or knows what might be causing it?
Last updated: 2025-11-20